Filterfans ELECTRO-TECHNOLOGY FOR INDUSTRY PF 22.000 Filterfan PFA 20.000 Exhaust filter Cooling capacity performance curve Static pressure performance curves PF 22.000 IP 54 PF 22.000 IP 54 Cooling capacity [W] Static pressure [Pa] 600 70 PF + 2 PFA 60 500 50 400 40 PF + PFA * Installation size 2, air flow rate up to 70 m /h 300 * System of protection IP 54 and IP 55, NEMA type 12 200 * UL, cUL approval 100 3 20 2 PFA 10 * UV-resistance (IP 55 version) 0 11622101055 11622151055 11622851055 11622801055 11622701055 IP 55 11622103055 11622153055 11622853055 11622803055 11622703055 AC 50 Hz / 60 Hz IP 54 Unimpeded airflow Air flow rate in combination (PF + PFA 20.000) IP 55 56 / 64 IP 54 44 / 52 IP 55 40 / 46 Current consumption Noise level (according to EN ISO 3741) 24 48 V m/h 5 5 5 W 0.12 / 0.18 0.24 / 0.23 0.42 0.21 0.1 A IP 55 44 / 44 44 dB(A) 0.7 0.44 kg terminal strip cable, 2-core, length 310 mm IP 54 NEMA type 12 - standard filter IP 55 NEMA type 12 - fluted filter IP 54 88 IP 55 91 IP 54 G3 IP 55 G4 sleeve bearing Bearing type 37500 2 Service life L10 (+ 40 C) 10 20 30 40 Air flow rate 50 60 70 [m 3/h] PF 22.000 IP 55 600 70 60 57 PF + 2 PFA 50 PFA 300 30 PF + PFA 200 100 40000 made of injection-moulded thermoplastic, self-extinguishing, UL 94 VO IP 55 additional: UV-resistant 5 h 1 Piece Article number Information on page IP 54 1 11720001055 149 IP 55 1 11720003055 149 1 17121000000 149 10 15 20 Dimensions mm PF 22.000 C / F RAL 7035 3 PF 0 25 30 35 40 46 0 10 20 Temperature difference T [K] % 62500 2 PFA 10 0 ball bearing IP 54 Colour Exhaust filter PFA 20.000 0 400 % - 15 ... + 55 / + 5 ... + 131 Temperature range Accessories 40 Static pressure [Pa] A 100 Duty cycle Design (housing and protection against accidental contact) 35 Cooling capacity [W] 0 6 Filter mat quality class1 30 20 IP 54 Fuse Filtration efficiency 25 61 40 20 / 20 Type of connection System of protection according to EN 60529 / UL 50 20 500 19 / 18 Weight Thermostat 12 61 / 70 Power consumption 15 PF 22.000 IP 55 DC 115 10 Unit IP 54 230 5 44 Temperature difference T [K] PF 22.000 Rated voltage 10 % 0 Filterfans Data PF 0 * Cut-out compatible with installation size 2 from the 3rd Generation (see page 150) Article number PFA 30 30 40 Air flow rate 56 50 60 70 [m 3/h] PFA 20.000 AC DC X 145 145 145 Y 145 145 145 Z1 5 5 5 A Z2 70 64 26 A1 125 125 125 B1 125 125 125 for material thicknesses up to 2 mm +1 mm for thickness of material > 2 mm 3 mm Z1 B Y according to DIN EN 779 2 fan failure is defined as being when the current and speed deviate or the operating noises are out of the ordinary 3 different colours available on request Approvals see page 111 1 114 X Further technical information can be found on the Internet: www.pfannenberg.com Z2 115