https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) MCR analog frequency converter for converting standard analog signals into frequency signals or PWM signals, with spring-cage connection. Replacement part: 2902032 MINI MCR-2-UI-FRO-PT. Your advantages Power supply possible via the foot element (TBUS) Error indication via diagnostic LED and analog signal Highly-compact analog-to-frequency transducer for electrical isolation, amplification, conversion, and filtering of standard signals to create frequencies or PWM signals Configurable interference filter 3-way isolation PWM output of 5 ... 95% Input and output signals can be configured via DIP switches Key Commercial Data Packing unit 1 pc GTIN GTIN 4017918996062 Weight per Piece (excluding packing) 65.400 g Custom tariff number 85437090 Country of origin Germany Technical data Dimensions Width 6.2 mm Height 93.1 mm 01/16/2021Page1/7 https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Technical data Dimensions Depth 102.5 mm Ambient conditions Ambient temperature (operation) -20 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C Maximum altitude 2000 m Permissible humidity (operation) 5 % ... 95 % (non-condensing) Degree of protection IP20 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Input data Configurable/programmable Yes Current input signal 0 mA ... 20 mA 4 mA ... 20 mA 0 mA ... 10 mA 2 mA ... 10 mA Input resistance current input approx. 50 Voltage input signal 0 V ... 5 V 1 V ... 5 V 0 V ... 10 V 2 V ... 10 V Input resistance of voltage input approx. 110 k Output data Number of outputs 1 Frequency output Frequency output: signal 0 Hz ... 10 kHz 0 Hz ... 5 kHz 0 Hz ... 2.5 kHz 0 Hz ... 1 kHz 0 Hz ... 500 Hz 0 Hz ... 250 Hz 0 Hz ... 100 Hz 0 Hz ... 50 Hz Frequency output: min. load 4 mA (UL / RL) 20 mA PWM output: signal 7.8 kHz (10 bit) 3.9 kHz (10 bit) 1.9 kHz (12 bit) 01/16/2021Page2/7 https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Technical data Frequency output 977 Hz (12 bit) 488 Hz (14 bit) 244 Hz (14 bit) 122 Hz (16bit) 61 Hz (16bit) PWM output: min. load 12 mA (UL / RL) 20 mA Maximum switching voltage 30 V Load current maximum 20 mA Overrange/underrange Can be set (via DIP switch) Type of protection Short-circuit protection, polarity reversal protection Step response (0-99%) < 15 ms (+ (1/f) smallest filter) < 1 s (+ (1/f) largest filter) Power supply Nominal supply voltage 24 VDC Supply voltage range 19.2 VDC ... 30 VDC (The DIN rail bus connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, Order No. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN60715)) Max. current consumption < 10 mA (at 24 V DC) Power consumption < 200 mW Connection data Connection method Spring-cage connection Stripping length 8 mm Conductor cross section solid 0.2 mm ... 2.5 mm Conductor cross section flexible 0.2 mm ... 2.5 mm Conductor cross section AWG 24 ... 12 General No. of channels 1 Maximum transmission error 0.1 % (> 7 kHz 0.2%) Maximum temperature coefficient < 0.02 %/K Temperature coefficient, typical < 0.02 %/K Electrical isolation Basic insulation according to EN 61010 Overvoltage category II Degree of pollution 2 Rated insulation voltage 30 VAC Test voltage, input/output/supply 1.5 kV (50 Hz, 1 min.) Electromagnetic compatibility Conformance with EMC directive 01/16/2021Page3/7 https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Technical data General Noise emission EN 61000-6-4 Noise immunity EN 61000-6-2 When being exposed to interference, there may be minimal deviations. Color green Housing material PBT Mounting position any Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 2 Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 2 EMC data Designation Electromagnetic RF field Standards/regulations EN61000-4-3 Typical deviation from the measuring range final value 2% Designation Fast transients (burst) Standards/regulations EN61000-4-4 Typical deviation from the measuring range final value 2% Designation Conducted interferences Standards/regulations EN61000-4-6 Typical deviation from the measuring range final value 2% Standards and Regulations Electromagnetic compatibility Conformance with EMC directive Noise emission EN 61000-6-4 Connection in acc. with standard CUL Standards/regulations EN 61000-4-2 Designation Electromagnetic RF field Standards/regulations EN61000-4-3 EN61000-4-4 EN61000-4-5 Designation Conducted interferences Standards/regulations EN61000-4-6 Electrical isolation Basic insulation according to EN 61010 Conformance CE-compliant ATEX II 3 G Ex nA IIC T4 Gc X UL, USA/Canada UL 508 Recognized Class I, Div. 2, Groups A, B, C, D T4 Environmental Product Compliance 01/16/2021Page4/7 https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Technical data Environmental Product Compliance China RoHS Environmentally Friendly Use Period = 50 years For details about hazardous substances go to tab "Downloads", Category "Manufacturer's declaration" Drawings Block diagram Diagram Frequency output T T T T T T Variable frequency / Period duration T PWM output (pulse width modulation) T T T T T T Variable pulse-pause ratio / Fixed period duration T Classifications eCl@ss eCl@ss 10.0.1 27210120 eCl@ss 4.0 27210100 eCl@ss 4.1 27210100 eCl@ss 5.0 27210100 eCl@ss 5.1 27210100 eCl@ss 6.0 27210100 eCl@ss 7.0 27210120 eCl@ss 8.0 27210120 eCl@ss 9.0 27210120 ETIM ETIM 4.0 EC002653 ETIM 5.0 EC002653 ETIM 6.0 EC002653 ETIM 7.0 EC002653 UNSPSC UNSPSC 6.01 30211506 01/16/2021Page5/7 https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Classifications UNSPSC UNSPSC 7.0901 39121008 UNSPSC 11 39121008 UNSPSC 12.01 39121008 UNSPSC 13.2 39121008 UNSPSC 19.0 39121008 Accessories Accessories DIN rail connector DIN rail bus connectors-ME 6,2 TBUS-2 1,5/5-ST-3,81 GN-2869728 DIN rail connector for DIN rail mounting. Universal for TBUS housing. Gold-plated contacts, 5-pos. Power module Power terminal block-MINI MCR-SL-PTB-2864134 MCR power terminal block for supplying several MINI Analog modules via the DIN rail connector, with screw connection, maximum current consumption of up to 2A Power terminal block-MINI MCR-SL-PTB-SP-2864147 MCR feed-in terminal for supplying several MINI Analog modules via a DIN rail connector, with spring-cage connection, maximum current consumption of up to 2A. Replacement part: 2902067 MINI MCR-2-PTB-PT. Power supply 01/16/2021Page6/7 https://www.phoenixcontact.com/us/products/2810243 Frequency transducer-MINI MCR-SL-UI-F-SP-2810243 Accessories Power supply unit-MINI-SYS-PS-100-240AC/24DC/1.5-2866983 Primary-switched MINI POWER supply for DIN rail mounting, input: 1-phase, output: 24 V DC/1.5 A Power supply unit-MINI-PS-100-240AC/24DC/1.5/EX-2866653 Primary-switched power supply MINI POWER for DIN rail mounting, input: 1-phase, output: 24 V DC/1,5 A, for the potentially explosive area Phoenix Contact 2021 (c) - all rights reserved http://www.phoenixcontact.com 01/16/2021Page7/7