TRANSFORMERS & MYRRA ...Of course ! INDUCTORS TECHNICAL INFORMATION RATED PRIMARY VOLTAGE (V) This is the supply voltage assigned to the transformer by the manufacturer. RATED SECONDARY VOLTAGE (V) This is the secondary output voltage assigned to the transformer when supplied with the rated primary voltage, frequency range, rated secondary current, all assigned by the manufacturer for the specified operating conditions of the transformer. RATED POWER (VA) The specified power levels in this catalogue are the secondary power levels, in other words, those available when the transformer is loaded. It is the product of the RMS rated secondary voltage by the RMS rated current. If the transformer has more than one output winding, the rated power denotes the maximum sum of the products of RMS rated secondary voltage by the RMS rated secondary current, respectively. This rated power is defined for rated ambient temperature conditions. example : P = 3,2 VA ta 70/B The transformer can deliver 3.2VA at maximum ambient (70C), the load consisting of a resistor load defined by R(load) = U(sec)2/P (assigned U sec & P values), heating does not exceed the relevant limit for Class B components used in this construction. NOTE : When the transformer is intended to supply DC voltage and current in conjunction with rectifiers and smoothing capacitors, the VA power required from the transformer is far higher than the U(DC) and I(DC) product. To help you to determine the true transformer power, our Technical Department is at your disposal. AMBIENT TEMPERATURE (ta) The maximum temperature at which the transformer may be operated continuously under nominal conditions of use. It is the air temperature measured close to the transformer after thermal stabilization when operating at rated conditions. HEATING The increase of the winding temperature when operating at rated conditions and maximum ambient temperature. The heating must be determined by the resistance method. TEMPERATURE CLASS The international classification of temperature classes is as follows : A E B F 105C 120C 130C 155C H 200 220 250 180 C 200 C 220 C 250 C It defines the maximum temperature the transformer components must withstand in continuous operation, in compliance with the N 85 IEC publication classification. There insulating materials are therefore certificated for the thermal index corresponding to the declared class in accordance with N 216 IEC standard. PARTICULAR POINTS OF EN 61558-2-6 STANDARD FOR SAFETY TRANSFORMERS On-load secondary voltage tolerance. This should not differ from the rated value by more than : 10% for transformers with build-in resistance to short-circuits (a supplement of 5% is granted on the 2 nd secondary for tranformers with 2 secondaries). 5% for other transformers whatever the secondaries number. Off-load secondary voltage. The values given in this catalogue are maximum theoretical values. NOTE : For safety transformers, this should never exceed 50 V rms. In the case of a transformer with several secondaries, the sum of the secondary voltages should be less tan 50 V rms. ADAPTED TRANSFORMERS FROM THE STANDARDS SERIES Any transformer whose requires Power and Ambient corresponding to those of our 44000 & 45000 range, and whose secondary voltage can fit in our minimum to maximum secondary range will be covered by EN61558-2-6,EN60950, or UL506 approvals, depending on the effective choice . SPECIAL TRANFORMERS MYRRA can use the 44000, 45000 or 46000 standard ranges to examine any transformer for compliance with your specifications and with international standards. On request, we can add thermal protection, thermal fuse, thermal switch-CTP. In certain cases, the addition of thermal protection enables the ambient temperature to be increased, while still complying with EN 61558. 4 SERIE 44000 EN 61558-2-6 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 40 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Inherently short-circuits proof * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request 7 5 6 7 5 1 9 10 1 5 UL 1585 QUALITY IN SERIES PRIMARY VOLTAGE 117 V Protection 9 6 7 EN 60950 9 10 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44025 6 100 9,94 T 70 B 0,6 44026 9 66 14,95 T 70 B 0,6 44027 12 50 19,9 T 70 B 0,6 44028 15 40 24,9 T 70 B 0,6 44029 18 33 29,9 T 70 B 0,6 44030 24 25 39,8 T 70 B 0,6 44031 2x6 2 x 50 2 x 9,94 T 70 B 0,6 44032 2x9 2 x 33 2 x 14,95 T 70 B 0,6 44033 2 x 12 2 x 25 2 x 19,9 T 70 B 0,6 44034 2 x 15 2 x 20 2 x 24,9 T 70 B 0,6 44035 2 x 18 2 x 17 2 x 29,9 T 70 B 0,6 44036 2 x 24 2 x 12 2 x 39,8 T 70 B 0,6 PRIMARY VOLTAGE 230 V Protection Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44013 6 100 9,94 T 70 B 0,6 44014 9 66 14,95 T 70 B 0,6 44015 12 50 19,9 T 70 B 0,6 44016 15 40 24,9 T 70 B 0,6 44017 18 33 29,9 T 70 B 0,6 44018 24 25 39,8 T 70 B 0,6 44019 2x6 2 x 50 2 x 9,94 T 70 B 0,6 44020 2x9 2 x 33 2 x 14,95 T 70 B 0,6 44021 2 x 12 2 x 25 2 x 19,9 T 70 B 0,6 44022* 2 x 15 2 x 20 2 x 24,9 T 70 B 0,6 44023* 2 x 18 2 x 17 2 x 29,9 T 70 B 0,6 44024* 2 x 24 2 x 12 2 x 39,8 T 70 B 0,6 *To be noted : * marked transformers are non approved. Those transformers meet all requirement of EN 61558-2-4. 5 44000 SERIES EI 30-5 ENCAPSULATED TRANSFORMERS 0,6 VA 1-1,8 VA EI 30-10,5 SERIE 44000 PRIMARY VOLTAGE 117 V 6 44000 SERIES ENCAPSULATED TRANSFORMERS Protection Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44061 6 167 8,6 T 70 B 1 44062 9 111 12,9 T 70 B 1 44063 12 83 17,2 T 70 B 1 44064 15 67 21,6 T 70 B 1 44065 18 56 25,9 T 70 B 1 44066 24 42 37,9 T 70 B 1 44067 2X6 2 x 83 2 x 8,6 T 70 B 1 44068 2x9 2 x 56 2 x 12,9 T 70 B 1 44069 2 x 12 2 x 42 2 x 19 T 70 B 1 44070 2 x 15 2 x 33 2 x 23,6 T 70 B 1 44071 2 x 18 2 x 28 2 x 24,9 T 70 B 1 44072 2 x 24 2 x 21 2 x 37,9 T 70 B 1 44338 6 250 10,1 ta 70/B 1,5 44339 9 167 15,3 ta 70/B 1,5 44340 12 125 20,2 ta 70/B 1,5 44341 15 100 25,3 ta 70/B 1,5 44342 18 83 31,2 ta 70/B 1,5 44343 24 63 43,3 ta 70/B 1,5 44344 2x6 125 2 x 10,1 ta 70/B 1,5 44345 2x9 83 2 x 15,3 ta 70/B 1,5 44346 2 x 12 63 2 x 20,2 ta 70/B 1,5 44347 2 x 15 50 2 x 25,0 ta 70/B 1,5 44348* 2 x 18 42 2 x 31 ta 70/B 1,5 44349* 2 x 24 31 2 x 43 ta 70/B 1,5 44840 6 300 10,1 ta 70/B 1,8 44841 9 200 15,2 ta 70/B 1,8 44842 12 150 20,3 ta 70/B 1,8 44843 15 120 27,3 ta 70/B 1,8 44844 18 100 30,4 ta 70/B 1,8 44845 24 75 40,6 ta 70/B 1,8 44846 2x6 2 x 150 2 x 10,1 ta 70/B 1,8 44847 2x9 2 x 100 2 x 15,2 ta 70/B 1,8 44848 2 x 12 2 x 75 2 x 20,3 ta 70/B 1,8 44849 2 x 15 2 x 60 2 x 27,3 ta 70/B 1,8 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 70 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Inherently short-circuits proof * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) 1 Secondary winding 7 9 5 1 Primary winding 6 7 9 10 2 Secondary windings 5 1 Primary winding Recommended layout for transformers with 1 secondary winding 6 7 5 9 10 1 (Allows the use of a transformer with 2 secondary windings) 1-1,8 VA EI 30-10,5 SERIE 44000 EN 60950 UL 1585 Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44049* 6 167 8,6 T 70 B 1 44050* 9 111 12,9 T 70 B 1 44051* 12 83 17,2 T 70 B 1 44052* 15 67 21,6 T 70 B 1 44053* 18 56 25,9 T 70 B 1 44054* 24 42 37,9 T 70 B 1 44055* 2x6 2 x 83 2 x 8,6 T 70 B 1 44056* 2x9 2 x 56 2 x 12,9 T 70 B 1 44057* 2 x 12 2 x 42 2 x 19 T 70 B 1 44058* 2 x 15 2 x 33 2 x 23,6 T 70 B 1 44059* 2 x 18 2 x 28 2 x 24,9 T 70 B 1 2 x 24 * Items usually available on stock 2 x 21 2 x 37,9 T 70 B 1 Protection * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request *To be noted 2 x 15 V and 2 x 24 V models are non-approved. Those transformers meet all requirement of EN 61558-2-4 Reference 44060** 44326 6 250 10,1 ta 70/B 1,5 44327 9 167 15,3 ta 70/B 1,5 44328 12 125 20,2 ta 70/B 1,5 44329 15 100 25,3 ta 70/B 1,5 44330 18 83 31,2 ta 70/B 1,5 44331 24 63 43,3 ta 70/B 1,5 44332 2x6 125 2 x 10,1 ta 70/B 1,5 44333 2x9 83 2 x 15,3 ta 70/B 1,5 44334 2 x 12 63 2 x 20,2 ta 70/B 1,5 44335 2 x 15 50 2 x 25,0 ta 70/B 1,5 44336* 2 x 18 42 2 x 31 ta 70/B 1,5 44337* 2 x 24 31 2 x 43 ta 70/B 1,5 44830 6 300 10,1 ta 70/B 1,8 44831 9 200 15,2 ta 70/B 1,8 44832 12 150 20,3 ta 70/B 1,8 44833 15 120 27,3 ta 70/B 1,8 44834 18 100 30,4 ta 70/B 1,8 44835 24 75 40,6 ta 70/B 1,8 44836 2x6 2 x 150 2 x 10,1 ta 70/B 1,8 44837 2x9 2 x 100 2 x 15,2 ta 70/B 1,8 44838 2 x 12 2 x 75 2 x 20,3 ta 70/B 1,8 44839* 2 x 15 2 x 60 2 x 27,3 ta 70/B 1,8 7 44000 SERIES EN 61558-2-6 ENCAPSULATED TRANSFORMERS PRIMARY VOLTAGE 230 V 1,5-1,8 VA EI 30-12,5 SERIE 44000 PRIMARY VOLTAGE 117 V Protection Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44097 6 250 9,7 T 70 B 1,5 44098 9 167 14,5 T 70 B 1,5 44099 12 125 19,3 T 70 B 1,5 44100 15 100 24,2 T 70 B 1,5 44101 18 83 29,8 T 70 B 1,5 44102 24 63 38,6 T 70 B 1,5 44103 2X6 2 x 125 2 x 9,7 T 70 B 1,5 44104 2x9 2 x 83 2 x 15 T 70 B 1,5 44105 2 x 12 2 x 63 2 x 19,3 T 70 B 1,5 44106 2 x 15 2 x 50 2 x 24,2 T 70 B 1,5 44107 2 x 18 2 x 42 2 x 29 T 70 B 1,5 44108 2 x 24 2 x 31 2 x 38,6 T 70 B 1,5 44726 6 283 9,8 T 50 B 1,7 44727 9 189 14,8 T 50 B 1,7 44728 12 142 19,7 T 50 B 1,7 44729 15 113 24,6 T 50 B 1,7 5 1 Primary winding 44730 18 94 30,3 T 50 B 1,7 2 Secondary windings 44731 24 71 39,3 T 50 B 1,7 44732 2x6 2 x 142 2 x 9,8 T 50 B 1,7 44733 2x9 2 x 94 2 x 15,2 T 50 B 1,7 44734 2 x 12 2 x 71 2 x 19,7 T 50 B 1,7 44735 2 x 15 2 x 57 2 x 24,6 T 50 B 1,7 44736 2 x 18 2 x 47 2 x 29,5 T 50 B 1,7 44737 2 x 24 2 x 35 2 x 39,3 T 50 B 1,7 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 80 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Inherently short-circuits proof * 30 V model is VDE EN 61558-2-6 certified (production on request) 1 Secondary winding 7 6 7 5 9 9 10 1 Primary winding 8 44000 SERIES ENCAPSULATED TRANSFORMERS Recommended layout for transformers with 1 secondary winding 44738 6 300 9,8 T 40 B 1,8 44739 9 200 14,8 T 40 B 1,8 44740 12 150 19,7 T 40 B 1,8 44741 15 120 24,6 T 40 B 1,8 44742 18 100 30,3 T 40 B 1,8 44743 24 75 39,3 T 40 B 1,8 44744 2x6 2 x 150 2 x 9,8 T 40 B 1,8 44745 2x9 2 x 100 2 x 15,2 T 40 B 1,8 44746 2 x 12 2 x 75 2 x 19,7 T 40 B 1,8 44747 2 x 15 2 x 60 2 x 24,6 T 40 B 1,8 44748 2 x 18 2 x 50 2 x 29,5 T 40 B 1,8 44749 2 x 24 2 x 38 2 x 39,3 T 40 B 1,8 6 7 5 9 10 1 (Allows the use of a transformer with 2 secondary windings) QUALITY IN SERIES 1,5-1,8 VA EI 30-12,5 SERIE 44000 Secondary current mA No-load voltage V Ambient Temperature C Rating VA EN 61558-2-6 EN 60950 UL 1585 44085* 6 250 9,7 T 70 B 1,5 * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request 44086* 9 167 14,5 T 70 B 1,5 44087* 12 125 19,3 T 70 B 1,5 44088* 15 100 24,2 T 70 B 1,5 44089* 18 83 29,8 T 70 B 1,5 *To be noted : 2 x 18 V and 2 x 24 V models are nonapproved. Those transformers meet all requirement of EN 61558-2-4 44090* 24 63 38,6 T 70 B 1,5 44091* 2X6 2 x 125 2 x 9,7 T 70 B 1,5 44092* 2x9 2 x 83 2 x 15 T 70 B 1,5 44093* 2 x 12 2 x 63 2 x 19,3 T 70 B 1,5 44094* 2 x 15 2 x 50 2 x 24,2 T 70 B 1,5 44095** 2 x 18 2 x 42 2 x 29 T 70 B 1,5 2 x 24 * Items usually available on stock 2 x 31 2 x 38,6 T 70 B 1,5 Reference 44096** 44647 6 283 9,8 T 50 B 1,7 44648 9 189 14,8 T 50 B 1,7 44649 12 142 19,7 T 50 B 1,7 44650 15 113 24,6 T 50 B 1,7 44651 18 94 30,3 T 50 B 1,7 44652 24 71 39,3 T 50 B 1,7 44653 2x6 2 x 142 2 x 9,8 T 50 B 1,7 44654 2x9 2 x 94 2 x 15,2 T 50 B 1,7 44655 2 x 12 2 x 71 2 x 19,7 T 50 B 1,7 44656 2 x 15 2 x 57 2 x 24,6 T 50 B 1,7 44483* 2 x 18 2 x 47 2 x 29,5 T 50 B 1,7 44484* 2 x 24 2 x 35 2 x 39,3 T 50 B 1,7 44657 6 300 9,8 T 40 B 1,8 44658 9 200 14,8 T 40 B 1,8 44659 12 150 19,7 T 40 B 1,8 44660 15 120 24,6 T 40 B 1,8 44661 18 100 30,3 T 40 B 1,8 44662 24 75 39,3 T 40 B 1,8 44663 2x6 2 x 150 2 x 9,8 T 40 B 1,8 44664 2x9 2 x 100 2 x 15,2 T 40 B 1,8 44665 2 x 12 2 x 75 2 x 19,7 T 40 B 1,8 44666 2 x 15 2 x 60 2 x 24,6 T 40 B 1,8 44485* 2 x 18 2 x 50 2 x 29,5 T 40 B 1,8 44486* 2 x 24 2 x 38 2 x 39,3 T 40 B 1,8 9 44000 SERIES Secondary voltage V Protection ENCAPSULATED TRANSFORMERS PRIMARY VOLTAGE 230 V 2-2,4 VA EI 30-15,5 SERIE 44000 PRIMARY VOLTAGE 117 V 44000 SERIES ENCAPSULATED TRANSFORMERS Protection 10 Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44133 6 333 10,4 T 70 B 2 44134 9 222 15,5 T 70 B 2 44135 12 167 20,7 T 70 B 2 44136 15 133 25,8 T 70 B 2 44137 18 111 30,8 T 70 B 2 44138 24 83 41,4 T 70 B 2 44139 2X6 2 x 167 2 x 10,4 T 70 B 2 44140 2x9 2 x 111 2 x 15,4 T 70 B 2 44141 2 x 12 2 x 83 2 x 20,7 T 70 B 2 44142 2 x 15 2 x 67 2 x 25,8 T 70 B 2 44143 2 x 18 2 x 56 2 x 30,8 T 70 B 2 44144 2 x 24 2 x 42 2 x 41,4 T 70 B 2 44750 6 383 10,5 T 50 B 2,3 44751 9 256 15,5 T 50 B 2,3 44752 12 192 21 T 50 B 2,3 44753 15 153 25,3 T 50 B 2,3 44754 18 128 31 T 50 B 2,3 44755 24 96 42 T 50 B 2,3 44756 2x6 2 x 192 2 x 10,5 T 50 B 2,3 44757 2x9 2 x 128 2 x 15,5 T 50 B 2,3 44758 2 x 12 2 x 96 2 x 21 T 50 B 2,3 44759 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3 44760 2 x 18 2 x 64 2 x 31 T 50 B 2,3 44761 2 x 24 2 x 48 2 x 42 T 50 B 2,3 44762 6 400 10,5 T 40 B 2,4 44763 9 267 15,5 T 40 B 2,4 44764 12 200 21 T 40 B 2,4 44765 15 160 25,3 T 40 B 2,4 44766 18 133 31 T 40 B 2,4 44767 24 100 42 T 40 B 2,4 44768 2x6 2 x 200 2 x 10,5 T 40 B 2,4 44769 2x9 2 x 133 2 x 15,5 T 40 B 2,4 44770 2 x 12 2 x 100 2 x 21 T 40 B 2,4 44771 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4 44772 2 x 18 2 x 67 2 x 31 T 40 B 2,4 44773 2 x 24 2 x 50 2 x 42 T 40 B 2,4 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 100 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Inherently short-circuits proof * 30 V model is VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV 1 Secondary winding 7 5 9 1 Primary winding 6 7 9 10 2 Secondary windings 5 1 Primary winding Recommended layout for transformers with 1 secondary winding 6 7 5 9 10 1 (Allows the use of a transformer with 2 secondary windings) 2-2,4 VA EI 30-15,5 SERIE 44000 Secondary current mA No-load voltage V Ambient Temperature C Rating VA EN 61558-2-6 EN 60950 UL 1585 44121* 6 333 10,4 T 70 B 2 * 100 % tested production * Certification : CCA procedure on request 44122* 9 222 15,5 T 70 B 2 44123* 12 167 20,7 T 70 B 2 44124* 15 133 25,8 T 70 B 2 *To be noted : 2 x 18 V and 2 x 24 V models are nonapproved. Those transformers meet all requirement of EN 61558-2-4 44125* 18 111 30,8 T 70 B 2 44126* 24 83 41,4 T 70 B 2 44127* 2X6 2 x 167 2 x 10,4 T 70 B 2 44128* 2x9 2 x 111 2 x 15,4 T 70 B 2 44129* 2 x 12 2 x 83 2 x 20,7 T 70 B 2 44130* 2 x 15 2 x 67 2 x 25,8 T 70 B 2 44131** 2 x 18 2 x 56 2 x 30,8 T 70 B 2 2 x 24 * Items usually available on stock 2 x 42 2 x 41,4 T 70 B 2 Reference 44132** 44667 6 383 10,5 T 50 B 2,3 44668 9 256 15,5 T 50 B 2,3 44669 12 192 21 T 50 B 2,3 44670 15 153 25,3 T 50 B 2,3 44671 18 128 31 T 50 B 2,3 44672 24 96 42 T 50 B 2,3 44673 2x6 2 x 192 2 x 10,5 T 50 B 2,3 44674 2x9 2 x 128 2 x 15,5 T 50 B 2,3 44675 2 x 12 2 x 96 2 x 21 T 50 B 2,3 44676 2 x 15 2 x 77 2 x 24,5 T 50 B 2,3 44487* 2 x 18 2 x 64 2 x 31 T 50 B 2,3 44488* 2 x 24 2 x 48 2 x 42 T 50 B 2,3 44677 6 400 10,5 T 40 B 2,4 44678 9 267 15,5 T 40 B 2,4 44679 12 200 21 T 40 B 2,4 44680 15 160 25,3 T 40 B 2,4 44681 18 133 31 T 40 B 2,4 44682 24 100 42 T 40 B 2,4 44683 2x6 2 x 200 2 x 10,5 T 40 B 2,4 44684 2x9 2 x 133 2 x 15,5 T 40 B 2,4 44685 2 x 12 2 x 100 2 x 21 T 40 B 2,4 44686 2 x 15 2 x 80 2 x 24,5 T 40 B 2,4 44489* 2 x 18 2 x 67 2 x 31 T 40 B 2,4 44490* 2 x 24 2 x 50 2 x 42 T 40 B 2,4 44000 SERIES Secondary voltage V Protection ENCAPSULATED TRANSFORMERS PRIMARY VOLTAGE 230 V 11 2,3-2,8 VA EI 30-18 SERIE 44000 PRIMARY VOLTAGE 117 V Protection Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44169 6 383 10,5 T 70 B 2,3 44170 9 256 15,7 T 70 B 2,3 44171 12 192 21 T 70 B 2,3 44172 15 153 25,9 T 70 B 2,3 44173 18 128 31,4 T 70 B 2,3 44174 24 96 41,9 T 70 B 2,3 44175 2X6 2 x 192 2 x 10,5 T 70 B 2,3 44176 2x9 2 x 128 2 x 15,7 T 70 B 2,3 44177 2 x 12 2 x 96 2 x 21 T 70 B 2,3 44178 2 x 15 2 x 77 2 x 25,9 T 70 B 2,3 44179 2 x 18 2 x 64 2 x 31,4 T 70 B 2,3 44180 2 x 24 2 x 48 2 x 41,9 T 70 B 2,3 44774 6 450 10,5 T 50 B 2,7 44775 9 300 15,4 T 50 B 2,7 44776 12 225 21,1 T 50 B 2,7 44777 15 180 26,3 T 50 B 2,7 5 1 Primary winding 44778 18 150 30,9 T 50 B 2,7 2 Secondary windings 44779 24 113 42 T 50 B 2,7 44780 2x6 2 x 225 2 x 10,5 T 50 B 2,7 44781 2x9 2 x 150 2 x 15,4 T 50 B 2,7 44782 2 x 12 2 x 113 2 x 21,1 T 50 B 2,7 44783 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7 44784 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7 44785 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 70 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Inherently short-circuits proof * 30 V model is VDE EN 61558-2-6 certified (production on request) 1 Secondary winding 7 6 7 5 9 9 10 1 Primary winding 44000 SERIES ENCAPSULATED TRANSFORMERS Recommended layout for transformers with 1 secondary winding 12 44786 6 467 10,5 T 40 B 2,8 44787 9 311 15,4 T 40 B 2,8 44788 12 233 21,1 T 40 B 2,8 44789 15 187 26,3 T 40 B 2,8 44790 18 156 30,9 T 40 B 2,8 44791 24 117 42,1 T 40 B 2,8 44792 2x6 2 x 233 2 x 10,5 T 40 B 2,8 44793 2x9 2 x 156 2 x 15,4 T 40 B 2,8 44794 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8 44795 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8 44796 2 x 18 2 x 77 2 x 31,5 T 40 B 2,8 44797 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8 6 7 5 9 10 1 (Allows the use of a transformer with 2 secondary windings) EN 60950 SERIE 44000 PRIMARY VOLTAGE 230 V UL 1585 * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request *To be noted : 2 x 18 V and 2 x 24 V models are nonapproved. Those transformers meet all requirement of EN 61558-2-4 Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 44157* 6 383 10,5 T 70 B 2,3 44158* 9 256 15,7 T 70 B 2,3 44159* 12 192 21 T 70 B 2,3 44160* 15 153 25,9 T 70 B 2,3 44161* 18 128 31,4 T 70 B 2,3 44162* 24 96 41,9 T 70 B 2,3 44163* 2X6 2 x 192 2 x 10,5 T 70 B 2,3 44164* 2x9 2 x 128 2 x 15,7 T 70 B 2,3 44165* 2 x 12 2 x 96 2 x 21 T 70 B 2,3 44166* 2 x 15 2 x 77 2 x 25,9 T 70 B 2,3 44167** 2 x 18 2 x 64 2 x 31,4 T 70 B 2,3 2 x 24 * Items usually available on stock 2 x 48 2 x 41,9 T 70 B 2,3 Protection Reference 44168** 44687 6 450 10,5 T 50 B 2,7 44688 9 300 15,4 T 50 B 2,7 44689 12 225 21,1 T 50 B 2,7 44690 15 180 26,3 T 50 B 2,7 44691 18 150 30,9 T 50 B 2,7 44692 24 113 42 T 50 B 2,7 44693 2x6 2 x 225 2 x 10,5 T 50 B 2,7 44694 2x9 2 x 150 2 x 15,4 T 50 B 2,7 44695 2 x 12 2 x 113 2 x 21,1 T 50 B 2,7 44696 2 x 15 2 x 90 2 x 26,3 T 50 B 2,7 44491* 2 x 18 2 x 75 2 x 31,5 T 50 B 2,7 44492* 2 x 24 2 x 56 2 x 42,1 T 50 B 2,7 44697 6 467 10,5 T 40 B 2,8 44698 9 311 15,4 T 40 B 2,8 44699 12 233 21,1 T 40 B 2,8 44700 15 187 26,3 T 40 B 2,8 44701 18 156 30,9 T 40 B 2,8 44702 24 117 42,1 T 40 B 2,8 44703 2x6 2 x 233 2 x 10,5 T 40 B 2,8 44704 2x9 2 x 156 2 x 15,4 T 40 B 2,8 44705 2 x 12 2 x 117 2 x 21,1 T 40 B 2,8 44706 2 x 15 2 x 93 2 x 26,3 T 40 B 2,8 44493* 2 x 18 2 x 70 2 x 31,5 T 40 B 2,8 44494* 2 x 24 2 x 58 2 x 42,1 T 40 B 2,8 44000 SERIES EN 61558-2-6 EI 30-18 ENCAPSULATED TRANSFORMERS 2,3-2,8 VA 13 3,2 VA EI 38-13,6 SERIE 44000 PRIMARY VOLTAGE 117 V Secondary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 630 44205 6 533 8 T 70 B 3,2 400 44206 9 356 12 T 70 B 3,2 315 44207 12 267 16 T 70 B 3,2 250 44208 15 213 20 T 70 B 3,2 200 44209 18 178 24,1 T 70 B 3,2 160 44210 24 133 32,1 T 70 B 3,2 315 44211 2x6 2 x 267 2x8 T 70 B 3,2 200 44212 2x9 2 x 178 2 x 12 T 70 B 3,2 160 44213 2 x 12 2 x 133 2 x 16 T 70 B 3,2 125 44214 2 x 15 2 x 107 2 x 20 T 70 B 3,2 100 44215 2 x 18 2 x 89 2 x 24 T 70 B 3,2 80 44216 2 x 24 2 x 67 2 x 32,1 T 70 B 3,2 5 VA EI 42-14,8 44000 SERIES ENCAPSULATED TRANSFORMERS 2 Secondary windings 1 Secondary winding 6 7 6 7 9 10 9 10 6 7 9 10 5 5 Primary winding 1 5 Primary winding 1 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) SERIE 44000 PRIMARY VOLTAGE 117 V 14 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 150 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Fuse protection on secondary side (see diagram) to be assumed by customer Secondary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 800 44241 6 833 8,4 T 50 B 5 630 44242 9 556 12,6 T 50 B 5 400 44243 12 417 16,9 T 50 B 5 315 44244 15 333 21 T 50 B 5 315 44245 18 278 25,3 T 50 B 5 200 44246 24 208 33,7 T 50 B 5 400 44247 2x6 2 x 417 2 x 8,4 T 50 B 5 315 44248 2x9 2 x 278 2 x 12,6 T 50 B 5 200 44249 2 x 12 2 x 208 2 x 16,9 T 50 B 5 160 44250 2 x 15 2 x 167 2 x 21 T 50 B 5 160 44251 2 x 18 2 x 139 2 x 25,3 T 50 B 5 100 44252 2 x 24 2 x 104 2 x 33,7 T 50 B 5 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 200 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Fuse protection on secondary side (see diagram) to be assumed by customer 6 7 9 10 6 7 9 10 2 Secondary windings 1 Secondary winding 6 7 5 5 Primary winding 1 5 Primary winding 1 9 10 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) EI 38-13,6 PRIMARY VOLTAGE 230 V EN 60950 * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request Secondary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 630 44193 6 533 8 T 70 B 3,2 400 44194 9 356 12 T 70 B 3,2 315 44195 12 267 16 T 70 B 3,2 250 44196 15 213 20 T 70 B 3,2 200 44197 18 178 24,1 T 70 B 3,2 160 44198 24 133 32,1 T 70 B 3,2 315 44199 2x6 2 x 267 2x8 T 70 B 3,2 200 44200 2x9 2 x 178 2 x 12 T 70 B 3,2 160 44201 2 x 12 2 x 133 2 x 16 T 70 B 3,2 125 44202 2 x 15 2 x 107 2 x 20 T 70 B 3,2 100 44203 2 x 18 2 x 89 2 x 24 T 70 B 3,2 80 44204* 2 x 24 2 x 67 2 x 32,1 T 70 B 3,2 4.5+0.5 *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4 5 VA EI 42-14,8 EN 61558-2-6 SERIE 44000 * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4 5+0.5 PRIMARY VOLTAGE 230 V EN 60950 Secondary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 800 44229 6 833 8,4 T 50 B 5 630 44230 9 556 12,6 T 50 B 5 400 44231 12 417 16,9 T 50 B 5 315 44232 15 333 21 T 50 B 5 315 44233 18 278 25,3 T 50 B 5 200 44234 24 208 33,7 T 50 B 5 400 44235 2x6 2 x 417 2 x 8,4 T 50 B 5 315 44236 2x9 2 x 278 2 x 12,6 T 50 B 5 200 44237 2 x 12 2 x 208 2 x 16,9 T 50 B 5 160 44238 2 x 15 2 x 167 2 x 21 T 50 B 5 160 44239 2 x 18 2 x 139 2 x 25,3 T 50 B 5 100 44240* 2 x 24 2 x 104 2 x 33,7 T 50 B 5 44000 SERIES EN 61558-2-6 SERIE 44000 ENCAPSULATED TRANSFORMERS 3,2 VA 15 10 VA EI 48-16,8 SERIE 44000 PRIMARY VOLTAGE 117 V Primary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 125 44277 6 1667 7,2 T 50 B 10 125 44278 9 1111 10,8 T 50 B 10 125 44279 12 833 14,4 T 50 B 10 125 44280 15 667 18,1 T 50 B 10 125 44281 18 556 21,6 T 50 B 10 125 44282 24 417 28,9 T 50 B 10 125 44283 2x6 2 x 833 2 x 7,2 T 50 B 10 125 44284 2x9 2 x 556 2 x 10,8 T 50 B 10 125 44285 2 x 12 2 x 417 2 x 14,4 T 50 B 10 125 44286 2 x 15 2 x 333 2 x 18,1 T 50 B 10 125 44287 2 x 18 2 x 278 2 x 21,6 T 50 B 10 125 44288 2 x 24 2 x 208 2 x 28,9 T 50 B 10 16 VA EI 54-18,8 44000 SERIES ENCAPSULATED TRANSFORMERS 2 Secondary windings 7 8 11 12 1 Secondary winding 7 8 11 12 78 11 12 6 6 Primary winding 6 1 Primary winding 1 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) SERIE 44000 PRIMARY VOLTAGE 117 V 16 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 300 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Fuse protection on primary side (see diagram) to be assumed by customer Secondary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 2,5 44313 6 2667 7,4 T 50 B 16 2,0 44314 9 1778 11,1 T 50 B 16 1,25 44315 12 1333 14,7 T 50 B 16 1 44316 15 1067 18,4 T 50 B 16 1 44317 18 889 22,1 T 50 B 16 0,63 44318 24 667 29,3 T 50 B 16 1,25 44319 2x6 2 x 1333 2 x 7,4 T 50 B 16 1 44320 2x9 2 x 889 2 x 11,1 T 50 B 16 0,63 44321 2 x 12 2 x 667 2 x 14,7 T 50 B 16 0,5 44322 2 x 15 2 x 533 2 x 18,4 T 50 B 16 0,5 44323 2 x 18 2 x 444 2 x 22 T 50 B 16 0,315 44324 2 x 24 2 x 333 2 x 29,3 T 50 B 16 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 400 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Fuse protection on secondary side (see diagram) to be assumed by customer 2 Secondary windings 8 9 13 14 1 Secondary winding 8 9 13 14 89 7 7 Primary winding 1 7 Primary winding 1 13 14 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) EI 48-16,8 PRIMARY VOLTAGE 230 V EN 60950 * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request Primary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 63 44265 6 1667 7,2 T 50 B 10 63 44266 9 1111 10,8 T 50 B 10 63 44267 12 833 14,4 T 50 B 10 63 44268 15 667 18,1 T 50 B 10 63 44269 18 556 21,6 T 50 B 10 63 44270 24 417 28,9 T 50 B 10 63 44271 2x6 2 x 833 2 x 7,2 T 50 B 10 63 44272 2x9 2 x 556 2 x 10,8 T 50 B 10 63 44273 2 x 12 2 x 417 2 x 14,4 T 50 B 10 63 44274 2 x 15 2 x 333 2 x 18,1 T 50 B 10 63 44275 2 x 18 2 x 278 2 x 21,6 T 50 B 10 63 44276* 2 x 24 2 x 208 2 x 28,9 T 50 B 10 *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4 16 VA EI 54-18,8 EN 61558-2-6 SERIE 44000 * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4 3.5+0.5 PRIMARY VOLTAGE 230 V EN 60950 Secondary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 2,500 44301 6 2667 7,4 T 50 B 16 2,000 44302 9 1778 11,1 T 50 B 16 1,25 44303 12 1333 14,7 T 50 B 16 1 44304 15 1067 18,4 T 50 B 16 1 44305 18 889 22,1 T 50 B 16 0,63 44306 24 667 29,3 T 50 B 16 1,25 44307 2x6 2 x 1333 2 x 7,4 T 50 B 16 1 44308 2x9 2 x 889 2 x 11,1 T 50 B 16 0,63 44309 2 x 12 2 x 667 2 x 14,7 T 50 B 16 0,5 44310 2 x 15 2 x 533 2 x 18,4 T 50 B 16 0,5 44311 2 x 18 2 x 444 2 x 22 T 50 B 16 0,315 44312* 2 x 24 2 x 333 2 x 29,3 T 50 B 16 44000 SERIES EN 61558-2-6 SERIE 44000 ENCAPSULATED TRANSFORMERS 10 VA 17 22 VA EI 60-21 SERIE 44000 PRIMARY VOLTAGE 117 V Primary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 250 44444 6 3667 6,8 T 50 B 22 250 44445 9 2444 10,3 T 50 B 22 250 44446 12 1833 13,7 T 50 B 22 250 44447 15 1467 17,1 T 50 B 22 250 44448 18 1222 20,5 T 50 B 22 250 44449 24 917 27,3 T 50 B 22 250 44450 2x6 2 x 1833 2 x 6,8 T 50 B 22 250 44451 2x9 2 x 1222 2 x 10,3 T 50 B 22 250 44452 2 x 12 2 x 917 2 x 13,7 T 50 B 22 250 44453 2 x 15 2 x 733 2 x 17,1 T 50 B 22 250 44454 2 x 18 2 x 611 2 x 20,5 T 50 B 22 250 44455 2 x 24 2 x 458 2 x 27,3 T 50 B 22 30 VA EI 66-23 44000 SERIES ENCAPSULATED TRANSFORMERS 2 Secondary windings 8 9 13 14 1 Secondary winding 8 9 13 14 8 9 13 14 7 7 Primary winding 1 7 Primary winding 1 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) SERIE 44000 PRIMARY VOLTAGE 117 V 18 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 550 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Fuse protection on primary side (see diagram) to be assumed by customer Primary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 315 44385 6 5000 6,9 T 50 B 30 315 44386 9 3333 10,3 T 50 B 30 315 44387 12 2500 13,8 T 50 B 30 315 44388 15 2000 17,2 T 50 B 30 315 44389 18 1667 20,8 T 50 B 30 315 44390 24 1250 27,7 T 50 B 30 315 44391 2x6 2 x 2500 2 x 6,9 T 50 B 30 315 44392 2x9 2 x 1667 2 x 10,3 T 50 B 30 315 44393 2 x 12 2 x 1250 2 x 13,8 T 50 B 30 315 44394 2 x 15 2 x 1000 2 x 17,2 T 50 B 30 315 44395 2 x 18 2 x 833 2 x 20,8 T 50 B 30 315 44396 2 x 24 2 x 625 2 x 27,7 T 50 B 30 * Vacuum filling * Two compartments bobbins * Self-extinguishing plastics UL 94 VO * Degree of protection IP 00 * 700 grams weight * Resin class B CEI 85 (20 000 h testing to CEI 126) * Fuse protection on primary side (see diagram) to be assumed by customer 2 Secondary windings 9 10 15 16 1 Secondary winding 9 10 15 16 9 10 8 8 Primary winding 1 8 Primary winding 1 15 16 1 Recommended layout for transformers with 1 secondary winding (Allows the use of a transformer with 2 secondary windings) EI 60-21 PRIMARY VOLTAGE 230 V EN 60950 * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request Primary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 125 44432 6 3667 6,8 T 50 B 22 125 44433 9 2444 10,3 T 50 B 22 *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4 30 VA EI 66-23 EN 61558-2-6 125 44434 12 1833 13,7 T 50 B 22 125 44435 15 1467 17,1 T 50 B 22 125 44436 18 1222 20,5 T 50 B 22 125 44437 24 917 27,3 T 50 B 22 125 44438 2x6 2 x 1833 2 x 6,8 T 50 B 22 125 44439 2x9 2 x 1222 2 x 10,3 T 50 B 22 125 44440 2 x 12 2 x 917 2 x 13,7 T 50 B 22 125 44441 2 x 15 2 x 733 2 x 17,1 T 50 B 22 125 44442 2 x 18 2 x 611 2 x 20,5 T 50 B 22 125 44443* 2 x 24 2 x 458 2 x 27,3 T 50 B 22 SERIE 44000 PRIMARY VOLTAGE 230 V EN 60950 * 30 V and 36 V models are VDE EN 61558-2-6 certified (production on request) * Insulation voltage 4 KV * 100 % tested production * Certification : CCA procedure on request *To be noted : 2 x 24 V model is non-approved. Those transformers meet all requirement of EN 61558-2-4 Primary protection mA Reference Secondary voltage V Secondary current mA No-load voltage V Ambient Temperature C Rating VA 160 44373 6 5000 6,9 T 50 B 30 160 44374 9 3333 10,3 T 50 B 30 160 44375 12 2500 13,8 T 50 B 30 160 44376 15 2000 17,2 T 50 B 30 160 44377 18 1667 20,8 T 50 B 30 160 44378 24 1250 27,7 T 50 B 30 160 44379 2x6 2 x 2500 2 x 6,9 T 50 B 30 160 44380 2x9 2 x 1667 2 x 10,3 T 50 B 30 160 44381 2 x 12 2 x 1250 2 x 13,8 T 50 B 30 160 44382 2 x 15 2 x 1000 2 x 17,2 T 50 B 30 160 44383 2 x 18 2 x 833 2 x 20,8 T 50 B 30 160 44384* 2 x 24 2 x 625 2 x 27,7 T 50 B 30 44000 SERIES EN 61558-2-6 SERIE 44000 ENCAPSULATED TRANSFORMERS 22 VA 19 BOXES WITH FIXING SUPPORT SERIE 44000 H L P X H L O ***** 6 10 6X5.0 **** ** * 44000 SERIES ENCAPSULATED TRANSFORMERS EI 60 1 ******* 8 14 6X5.0 7 14 1 12 5.0 6X5.0 * ****** 5X5.0 ****** 6 ******7 EI 66 1 7 ** **** * 8 16 Y 0,50 7X5.0 ******** 8 ******** 9 CIRCUIT L 0,50 P 0,40 H 0,40 X 0,50 EI 38 X 13,6 55,6 34,9 28,1 47,5 3,2 EI 42 X 14,8 64 37 32,3 55,0 4,2 EI 48 X 16,8 69 42,3 34,6 60 4,2 EI 54 X 18,8 74 47,3 38,8 65 4,2 EI 60 X 21 81,5 53,3 44,7 72,5 43,5 4,2 EI 66 X 23 87,2 58,6 48,5 77,5 47,5 4,2 O 0,3 Series 44000 transformers can be equiped with boxes with lugs and also 2,8 faston terminal tags while still conforming to the specifications in the standard references. * For boxes with 2 lugs and pin type output, add suffix 1 to the reference of the standard transformer (example : 44198-1) * For boxes with 2 lugs and 2,8 faston output, add suffix 2 to the reference of the standard transformer (example : 44199-2) * For boxes with 4 lugs and pin type output, add suffix 3 to the reference of the standard transformer (example : 44200-3) * For boxes with 4 lugs and 2,8 faston output, add suffix 4 to the reference of the standard transformer (example : 44201-4) These models are not available on stock. 20 ** * ** 6 10 5.0 EI 54 1 ** * ** 5 11X2.5 1 7.5 7X5.0 ***** 5 EI 48 5X5.0 1 7.5 EI 42 13X2.5 EI 38 5X5.0 4X5.0 X Y P O 1 VA UI 21 SERIE 45000 * 230 V supply voltage by series/parallel connection * Vacuum filling * One compartiment housing 1 VA * Two compartments bobbins 0,8 VA * Degree of protection IP 00 * 50 grams weight 1 VA * Resin UL 94 VO * Design protection against short-circuits * Insulation voltage 4 KV * 100 % tested production Conform to EN 61558 - UL 506 PRIMARY VOLTAGE 230 V Secondary voltage V UI 21 Type 1 VA 2 5 Primary windings Secondary windings 12 7 QUALITY IN SERIES Secondary current mA No-load voltage V 230 V Ambient Temperature C 1 VA 45001 6 167 11,4 T 70 B 45002 9 111 17 T 70 B 45003 12 83 22,8 T 70 B 45004 15 67 28,5 T 70 B 45005 18 56 34,2 T 70 B 45006 24 42 45,6 T 70 B 45000 SERIES Reference ENCAPSULATED TRANSFORMERS Protection 21 3-10 VA UI 30 SERIE 45000 PRIMARY VOLTAGE 115 V - 230 V Protection Reference Secondary voltage V Secondary current mA No-load voltage V UI 30 x 5,5 2x6 2 x 167 2 x 10,2 T 70 B 45293 2x9 2 x 111 2 x 15,9 T 70 B 45294 2 x12 2 x 83 2 x 20,4 T 70 B 45295 2 x15 2 x 67 2 x 25,5 T 70 B 45296 2 x18 2 x 56 2 x 30,6 T 70 B 45297 2 x24 2 x 42 2 x 40,8 T 70 B 3 VA 45013 2x6 2 x 250 2 x 9,8 T 70 B 160 45014 2x9 2 x 167 2 x 14,7 T 70 B 125 45015 2 x 12 2 x 125 2 x 19,6 T 70 B 100 45016 2 x 15 2 x 100 2 x 24,5 T 70 B 80 45017 2 x 18 2 x 83 2 x 29,5 T 70 B 63 45018 2 x 24 2 x 63 2 x 39,3 T 70 B Secondary protection mA 4 VA 315 45019 2x6 2 x 333 2 x 9,4 T 70 B 250 45020 2x9 2 x 222 2 x 14,0 T 70 B 160 45021 2 x 12 2 x 167 2 x 18,6 T 70 B 125 45022 2 x 15 2 x 133 2 x 23,3 T 70 B 125 45023 2 x 18 2 x 111 2 x 28,0 T 70 B 80 45024 2 x 24 2 x 83 2 x 37,4 T 70 B UI 30 x 10,5 Secondary protection mA 45025 2x6 2 x 500 2 x 8,1 T 70 B 315 45026 2x9 2 x 333 2 x 12,1 T 70 B 250 45027 2 x 12 2 x 250 2 x 16,2 T 70 B 200 45028 2 x 15 2 x 200 2 x 20,2 T 70 B 160 45029 2 x 18 2 x 167 2 x 24,3 T 70 B 125 45030 2 x 24 2 x 125 2 x 32,3 T 70 B 10 VA Primary protection mA CIRCUIT RATING DIMENSION A WEIGHT UI 30 x 5,5 2 VA/3 VA A = 17 mm 125 g UI 30 x 7,5 4 VA A = 19 mm 150 g UI 30 x 10,5 6 VA A = 22 mm 185 g UI 30 x 16,5 10 VA A = 28 mm 260 g 6 VA 500 UI 30 x 16,5 45000 SERIES Secondary protection mA 250 UI 30 x 7,5 ENCAPSULATED TRANSFORMERS 2 VA 45292 UI 30 x 5,5 22 Ambient Temperature C *115 V- 230 V supply voltage by series/parallel connection * Vacuum filling * Two compartments bobbins * Degree of protection IP 00 * Resin class UL 94 VO 125/63 45031 2x6 2 x 833 2 x 7,9 T 50 B 125/63 45032 2x9 2 x 556 2 x 11,9 T 50 B 125/63 45033 2 x 12 2 x 417 2 x 15,9 T 50 B 125/63 45034 2 x 15 2 x 333 2 x 19,8 T 50 B 125/63 45035 2 x 18 2 x 278 2 x 23,7 T 50 B 125/63 45036 2 x 24 2 x 208 2 x 31,7 T 50 B * 1 Possible primary connections * 230 V 3 5 7 16 14 12 10 * 1 * Possible secondary connections 115 V 3 5 7 16 14 12 10 1 3 5 7 16 14 12 10 * * Secondary voltage doubled QUALITY IN SERIES 1 * * 3 5 * * 7 16 14 12 10 Double the secondary current SERIE 45000 PRIMARY VOLTAGE 115 V - 230 V * Fuse protection in secondary winding (see diagram) * Insulation voltage 4 KV * 100 % tested production * Conform to EN 61558 Approval under process * UL 506 approved Primary protection 115 V/230 V mA Reference Secondary voltage V Secondary current mA UI 39 x 8 125/63 45037 2x6 2 x 833 2 x 8,2 T 50 B 125/63 45038 2x9 2 x 555 2 x 12,3 T 50 B 125/63 45039 2 x 12 2 x 416 2 x 16,4 T 50 B 125/63 45040 2 x 15 2 x 333 2 x 20,5 T 50 B 125/63 45041 2 x 18 2 x 277 2 x 24,6 T 50 B 125/63 45042 2 x 24 2 x 208 2 x 32,8 T 50 B 14 VA 160/80 45043 2x6 2 x 1167 2 x 7,5 T 50 B 160/80 45044 2x9 2 x 778 2 x 10,9 T 50 B 160/80 45045 2 x 12 2 x 583 2 x 15,0 T 50 B 160/80 45046 2 x 15 2 x 467 2 x 18,7 T 50 B 160/80 45047 2 x 18 2 x 389 2 x 22,4 T 50 B 160/80 45048 2 x 24 2 x 292 2 x 30,2 T 50 B UI 39 x 13,5 RATING DIMENSION A WEIGHT UI 39 x 8 10 VA A = 22 mm 285 g UI 39 x 10,2 14 VA A = 24 mm 335 g UI 39 x 13,5 18 VA A = 27 mm 405 g UI 39 x 17 24 VA A = 31 mm 480 g UI 39 x 21 30 VA A = 35 mm 550 g 18 VA 200/100 45049 2x6 2 x 1500 2 x 7,4 T 50 B 200/100 45050 2x9 2 x 1000 2 x 11,0 T 50 B 200/100 45051 2 x 12 2 x 750 2 x 14,7 T 50 B 200/100 45052 2 x 15 2 x 600 2 x 18,3 T 50 B 200/100 45053 2 x 18 2 x 500 2 x 22,0 T 50 B 200/100 45054 2 x 24 2 x 375 2 x 29,4 T 50 B UI 39 x 17 * 1 Possible primary connections * 230 V 4 6 9 * 1 ** Possible secondary connections 115 V 4 6 9 19 17 14 12 19 17 14 12 sec 1 sec 2 sec 1 sec 2 ** ** ** ** 1 4 19 17 * 6 9 14 12 * Secondary voltage doubled 1 4 ** 19 17 6 9 * * 14 12 Double the secondary current Ambient Temperature C 10 VA UI 39 x 10,2 CIRCUIT No-load voltage V 24 VA 250/125 45055 2x6 2 x 2000 2 x 7,1 T 50 B 250/125 45056 2x9 2 x 1333 2 x 10,6 T 50 B 250/125 45057 2 x 12 2 x 1000 2 x 14,1 T 50 B 250/125 45058 2 x 15 2 x 800 2 x 17,6 T 50 B 250/125 45059 2 x 18 2 x 667 2 x 21,2 T 50 B 250/125 45060 2 x 24 2 x 500 2 x 28,3 T 50 B UI 39 x 21 30 VA 315/160 45061 2x6 2 x 2500 2 x 6,7 T 50 B 315/160 45062 2x9 2 x 1667 2 x 10,15 T 50 B 315/160 45063 2 x 12 2 x 1250 2 x 13,5 T 50 B 315/160 45064 2 x 15 2 x 1000 2 x 16,8 T 50 B 315/160 45065 2 x 18 2 x 833 2 x 20,2 T 50 B 315/160 45066 2 x 24 2 x 625 2 x 27,0 T 50 B 45000 SERIES UI 39 ENCAPSULATED TRANSFORMERS 10-30 VA 23 40-60 VA UI 48 SERIE 45000 * 115 V- 230 V supply voltage by series/parallel connection * Vacuum filling * Two compartments bobbins * Degree of protection IP 00 * Resin class UL 94 VO * Fuse protection in secondary winding (see diagram) * Insulation voltage 4 KV * 100 % tested production * Conform to EN 61558 Approval under process * UL 506 approved PRIMARY VOLTAGE 115 V - 230 V Primary protection 115/230 V mA Reference Secondary voltage V Secondary current mA U I 48 x 17 Ambient Temperature C 40 VA 400/200 45067 2x6 2 x 3333 2 x 6,7 T 50 B 400/200 45068 2x9 2 x 2222 2 x 10,0 T 50 B 400/200 45069 2 x 12 2 x 1667 2 x 13,4 T 50 B 400/200 45070 2 x 15 2 x 1333 2 x 16,7 T 50 B 400/200 45071 2 x 18 2 x 1111 2 x 20,1 T 50 B 400/200 45072 2 x 24 2 x 833 2 x 26,8 T 50 B U I 48 x 26 60 VA 630/315 45073 2x6 2 x 5000 2 x 6,6 T 50 B 630/315 45074 2x9 2 x 3333 2 x 9,9 T 50 B 630/315 45075 2 x 12 2 x 2500 2 x 13,1 T 50 B 630/315 45076 2 x 15 2 x 2000 2 x 16,4 T 50 B UI 48 x 17 40 VA 38,5 13,5 83 760 g 630/315 45077 2 x 18 2 x 1667 2 x 19,7 T 50 B UI 48 x 26 60 VA 48,5 14,5 86 1060 g 630/315 45078 2 x 24 2 x 1250 2 x 26,3 T 50 B CIRCUIT RATING Possible primary connections * 230 V 1 4 23 45000 SERIES ENCAPSULATED TRANSFORMERS No-load voltage V 24 9 20 17 * 12 14 * * 115 V 1 4 23 9 20 17 A * * 12 14 B C WEIGHT Possible secondary connections 1 4 23 * 9 20 17 12 14 * Secondary voltage doubled QUALITY IN SERIES 1 4 23 * * 9 20 17 12 * * 14 Double the secondary current