Description
Quarter-wave stub technology
Benefits
Broad-band design
The protector can also be installed reversely
Compliant to IEC 61643-21
Product Configuration
Main path connectors Port 1: unprotected, N jack (female) - Port 2: protected, N jack (female)
Mounting and grounding MH69 (MH=bulkhead mounting)
Side of bulkhead protected side
Technical Data
Electrical Data
Impedance 50 Ω
Frequency range 6000 to 18000 MHz
Return loss ≥ 20 dB
Insertion loss ≤ 0.3 dB
RF CW power ≤ 100 W
PIM 3rd order not specified
Surge current handling capability 50 multiple kA (test pulse 8/20 µs)
Residual pulse energy 5 µJ typically (test pulse 4 kV 1.2/50 µs / 2 kA 8/20 µs) main path - protected side
Mechanical Data
Weight 225 g
Environmental Data
Operating temperature -40 °C to +85 °C
Waterproof degree IP 65 (according to IEC 60529, data refer to the coupled state)
2002/95/EC (RoHS) compliant
Material Data
Piece Parts Material Surface Plating
Housing Brass SUCOPLATE (R) Plating
Port 1 center contact Copper Beryllium Alloy Gold Plating (without Nickel underplating)
Port 2 center contact Copper Beryllium Alloy Gold Plating (without Nickel underplating)
Related Documents
Outline drawing DOU-00003513
Mounting instruction DOC-0000176104