HUBER+SUHNER® DATA SHEET
EMP Protector: 3400.17.0380 Rev.: I
Document: DOC-0000176665 U Issued: 22.05.2013 13:38:36 Uncontrolled Copy Page 1/1
HUBER+SUHNER is certified according to ISO 9001 and ISO 14001
HUBER+SUHNER AG
RF Protection
9100 Herisau, Switzerland
Phone +41 (0)71 353 41 11
Fax +41 (0)71 353 47 51
www.hubersuhner.com
WAIVER!
It is exclusively in written agreements that we provide our customers with warrants and
representations as to the technical contained specifications and/or the fitness for any particular
purpose. The facts and figures herein are carefully compiled to the best of our knowledge, but they are
intended for general informational purposes only.
HUBER+SUHNER – Excellence in Connectivity Solutions
Description
Quarter-wave stub technology
Benefits
Broad-band design
The protector can also be installed reversely
Compliant to IEC 61643-21
Product Configuration
Main path connectors Port 1: unprotected, N jack (female) - Port 2: protected, N jack (female)
Mounting and grounding MH69 (MH=bulkhead mounting)
Side of bulkhead protected side
Technical Data
Electrical Data
Impedance 50
Frequency range 6000 to 18000 MHz
Return loss 20 dB
Insertion loss 0.3 dB
RF CW power 100 W
PIM 3rd order not specified
Surge current handling capability 50 multiple kA (test pulse 8/20 µs)
Residual pulse energy 5 µJ typically (test pulse 4 kV 1.2/50 µs / 2 kA 8/20 µs) main path - protected side
Mechanical Data
Weight 225 g
Environmental Data
Operating temperature -40 °C to +85 °C
Waterproof degree IP 65 (according to IEC 60529, data refer to the coupled state)
2002/95/EC (RoHS) compliant
Material Data
Piece Parts Material Surface Plating
Housing Brass SUCOPLATE (R) Plating
Port 1 center contact Copper Beryllium Alloy Gold Plating (without Nickel underplating)
Port 2 center contact Copper Beryllium Alloy Gold Plating (without Nickel underplating)