Data sheet...
Creation date April 29, 2013 11:09:38 PM CEST
Catalogue status 12.03.2013 / We reserve the right to make technical changes. 1
Industrial Ethernet
IE-C5DD4UG0010MSSMCS-E
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
General ordering data
Order No. 1059330010
Type IE-C5DD4UG0010MSSMCS-E
Version Dragline cable, PROFINET, M12 IP 67 straight
socket, M12 IP 67 straight male, Cat.5 (ISO/IEC
11801) / Cat.5e (TIA T568-B), PUR, 1 m
GTIN (EAN) 4050118000368
Qty. 1 pc(s).
Industrial Ethernet connection technology by Weidmüller
offers the optimal solution for the infrastructure of your
machine, system or factory. All connection technology is
available from one source.
The benefits for you:
IEC-standardised connectors, in the variants 1, 4, 5, 6
and 14
Cat. 6 throughoutA with STEADYTEC® technolgy
pre-assembled cables and cables sold by the metre
Copper and fibre-optic cables
in IP20 and IP67
all relevant industrial connections: RJ45, M12, SC, ...
comprehensive range of accessories
Data sheet...
Industrial Ethernet
IE-C5DD4UG0010MSSMCS-E
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date April 29, 2013 11:09:39 PM CEST
Catalogue status 12.03.2013 / We reserve the right to make technical changes. 2
Dimensions and weights
Length 1 m Net weight 98.23 g
Temperatures
Operating temperature -40 °C...+70 °C Storage temperature -50 °C...+70 °C
Installation temperature -20 °C...+60 °C
Electrical properties
Insulation resistance 500.000 Ω
Standards
Standard, insulating material DIN EN 50290-2-23 (VDE
0819) Table 2/A (HD
624.3)
Standard, wire material
DIN EN 13602 Cu-ETP-A
Standard, shielding material DIN EN 13602 Cu-ETP-
A..B
Cable structure
Wire material
Stranded tin-plated copper
wire
Standard designations 2YH(ST)C11Y
2x2x0,75/1,5-100 LI VZN
GN FRNC
Strands 7 Cross-section 4*AWG 22/7 - 0.36 mm²
Insulation PE Insulation cross-section 1.5 mm
Wire core insulation thickness 0.38 mm No. of wires 4
Arrangement of wire cores Star-quad Colour sequence or wires - wire pairs white, yellow, blue, orange
Diameter of inner sheathing 3.9 mm Filler As central element
Shielding
SF/UTP
Complete shielding Aluminium foil, Shielding
braid made from copper
wiring
Shielding braid thickness 0.13 mm Overlap of shielding braid 85 %
Material sheath PUR Sheath diameter, min. 6.3 mm
Sheath diameter, max. 6.7 mm Sheathing material thickness 0.9 mm
Sheathing colour green (RAL 6018)
Electrical properties of cable
Category Cat.5 (ISO/IEC 11801) /
Cat.5e (TIA T568-B)
Operating voltage, UL
600 V
Test voltage: wire-wire-shield, at RMS
50Hz, 1 min. 2,000 V
Characteristic impedance 100 ± 15 Ω at 1–100
MHz
Loop resistance 120 Ω/km Deviation 40 ns/100m
Resistance differential 3 % Transfer impedance 20 mΩ/m at 10 MHz
Insulation resistance 500.000 Ω Capacity at 1 kHz 52 nF/km
Signal propagation time 5.3 ns/m
Data sheet...
Industrial Ethernet
IE-C5DD4UG0010MSSMCS-E
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date April 29, 2013 11:09:39 PM CEST
Catalogue status 12.03.2013 / We reserve the right to make technical changes. 3
Mechanical and material properties of cable
Bending cycles 3 Mio Min. bending radius, once only 5 *diameter
Min. bending radius, repetitive 7.5 *diameter Pulling force ≤ 150 N
Speed 180 m/min Acceleration 4 m/
Abrasion resistance
very good
Resistance to spread of flame in accordance with IEC
60332-1
Resistance to oils in accordance with IEC
60811-2-1
UV-resistant
Yes
Silicone-free
Yes
Halogen in accordance with IEC
60754-2
Fire propagation No
plug
Version connector left M12 IP 67 straight socket Version connector right M12 IP 67 straight male
Classifications
eClass 6.2 27-06-03-90
Approvals
Approvals