Pushbutton Switch (Cylindrical 30-dia.) ZAP CSM_ZAP_DS_E_3_1 Long Service Life with Built-in Z-series Basic Switch * Using a Basic Switch enables direct switching of large-capacity loads * Shock-absorbing construction of Operation Unit protects the Switch * Drip-proof Pushbutton construction enables use in locations subject to splashing water and oil and scattering dust. * Pushbuttons are available in three shapes and six colors. Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions on page 3. Ordering Information Shape of Operation Unit Classification Output Blue (-A) Operation Unit color Green (-G) Red (-R) Black (-B) White (-W) Yellow (-Y) 1 ZAP-A ZAP-B ZAP-G ZAP-R ZAP-W ZAP-Y 2 2ZAP-A 2ZAP-B 2ZAP-G 2ZAP-R 2ZAP-W 2ZAP-Y 1 ZAP-1A ZAP-1B ZAP-1G ZAP-1R ZAP-1W ZAP-1Y 2 2ZAP-1A 2ZAP-1B 2ZAP-1G 2ZAP-1R 2ZAP-1W 2ZAP-1Y 1 ZAP-2A ZAP-2B ZAP-2G ZAP-2R ZAP-2W ZAP-2Y 2 2ZAP-2A 2ZAP-2B 2ZAP-2G 2ZAP-2R 2ZAP-2W 2ZAP-2Y 36 dia. 25 dia. Momentary operation 36 dia. 25 dia. 40 dia. Note: Models with special specifications are available for use in environments with high humidity or outdoors. Contact your OMRON representative for information. Specifications Ratings Item Non-inductive load (A) Rated voltage (V) NC Note: 1. 2. 3. 4. 5. NO Inductive load (A) Lamp load Inductive load NC NO 125 VAC 200 VAC 500 VAC 15 15 10 3 2.5 1.5 1.5 1.25 0.75 15 15 6 8 VDC 14 VDC 30 VDC 125 VDC 250 VDC 15 15 6 0.5 0.25 3 3 3 0.5 0.25 1.5 1.5 1.5 0.5 0.25 15 10 5 0.05 0.03 Built-in Switch Z-15G5-B Resistive load NC NO Motor load NC 15 3 1.5 5 5 5 0.05 0.03 NO 2.5 1.5 0.75 2.5 2.5 2.5 0.05 0.03 The above values are for steady-state currents. Inductive load: Power factor = 0.4 (AC); time constant = 7 ms (DC). The lamp load has an inrush current of 10 times the steady-state current. The motor load has an inrush current of 6 times the steady-state current. Standard testing condition. (1) Ambient temperature: 20 2C (2) Ambient humidity: 65% 5%RH (3) Operating frequency: 20 times/min 1 ZAP Specifications Characteristics Operating frequency Operating Characteristics Mechanical 60 operations/min Electrical 20 operations/min Model Operating characteristics Operating force OF Insulation resistance 100 M min. (at 500 VDC) Contact resistance 30 m max. (initial value) Dielectric strength Vibration resistance Between terminals of same polarity Approx. 14.7 N Contact form NC COM NO Approved Safety Standards * The built-in Z-15G5-B Switch is approved for UL and CSA. 500 m/s2 200 m/s2 max. (1 ms max.) Mechanical 1,000,000 operations min. Electrical 500,000 operations min. Weight Inrush current Approx. 9.81 N Name Double-throw contacts 10 to 55 Hz, 1.5-mm double amplitude (1 ms max.) Shock re- Destruction sistance Malfunction Durability 2ZAP-@@ Contact Form 1,000 VAC, 50/60 Hz for 1 min Between current-carrying metal part 2,000 VAC, 50/60 Hz for and ground, and between each termi1 minute nal and non-current-carrying metal part Malfunction ZAP-@@ Approx. 130 to 210 g NC 30 A max. NO 15 A max. Ambient operating temperature -25 to 80C (with no icing or condensation) Ambient operating humidity 35% to 85%RH Ambient storage temperature -25 to 80C (with no icing or condensation) Degree of protection IP65 (Operation Unit only) Electric shock protection class Class II PTI (proof tracking index) 175 Pollution degree 3 (IEC947-5-1) Dimensions Insert one of the following letters into the box (@) at the end of the model number. Refer to Ordering Information for color symbols. (Unit: mm) ZAP-@ 2ZAP-@ ZAP-@ 2ZAP-@ Washer 26 Mounting panel thickness: 1.6 to 6 mm Z-15G5-B Basic Switch Rubber packing 24.6 25 dia. 25 dia. 36 dia. 37 * 49.2 52 24.6 26 9.75 19 43.5 10.8 t 40 dia. Three, M4 5.5 Terminal screws (with toothed washer) 51.8 max. * Chromed plating ZAP-1@ 2ZAP-1@ ZAP-2@ 2ZAP-2@ 40 dia. 36 dia. 36 dia. 25 dia. * Mounting panel thickness: 1.6 to 6 mm t t 15.8 * Chromed plating Mounting panel thickness: 1.6 to 6 mm * 27.6 * Chromed plating 2 ZAP Dimensions (Unit: mm) Panel Cutouts Accessories Rubber Cap * Use the special rubber cap to use the Switch in locations subject to significant splashing water and oil or scattering dust. Cannot be used, however, with the (2) ZAP-2. 5.2 dia. 15 30.50.3 dia. hole Color Blue (-A) Black (-B) Green (-G) Red (-R) White (-W) Yellow (-Y) Model ZB-A ZB-B ZB-G ZB-R ZB-W ZB-Y Safety Precautions Refer to Safety Precautions for All Pushbutton Switches. Precautions for Correct Use Insulation * After wiring the Switch, ensure an appropriate insulating distance. Wiring * Tighten the terminal screws to a torque of 0.78 to 1.18 N*m. Mounting * Tighten the face nut to a torque of 0.98 to 1.76 N*m. * For panel mounting, always use a washer (or a nameplate) and rubber packing. Washer (or nameplate) Rubber packing Mounting panel t = 1.6 to 6 mm 3 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2011.8 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2011 All Right Reserved.