https://www.phoenixcontact.com/us/products/1574551
11.11.2013Page1/4
Sensor/Actuator cable-SAC-8P-MS/10,0-285 SH SCO-1574551
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://download.phoenixcontact.com)
Sensor/Actuator cable, 8-position, PUR, Gray RAL 7001, shielded, Plug straight M12 SPEEDCON, A-coded, on
Free cable end, Cable length: 10 m, Twisted pair cables
as in the figure, but with a gray
conductor
Key commercial data
Packing unit 1 1
Minimum order quantity 50 1
Weight per Piece (excluding packing) 222.22 GRM
Custom tariff number 85444290
Country of origin Poland
Technical data
Dimensions
Length of cable 10 m
Stripping length of the free conductor end 50 mm
Ambient conditions
Ambient temperature (operation) -25 °C ... 90 °C (Plug / socket)
Degree of protection IP65
IP67
General
Rated current at 40°C 2 A
Rated voltage 30 V
Number of positions 8
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Coding A - standard
Status display No
Surge voltage category II
Pollution degree 3
Material
https://www.phoenixcontact.com/us/products/1574551
11.11.2013Page2/4
Sensor/Actuator cable-SAC-8P-MS/10,0-285 SH SCO-1574551
Technical data
Material
Inflammability class according to UL 94 HB
Contact material CuZn
Contact surface material Ni/Au
Contact carrier material TPU GF
Material of grip body TPU, hardly inflammable, self-extinguishing
Material, knurls Zinc die-cast, nickel-plated
Sealing material NBR
Cable
Cable type PUR, gray, shielded
Cable type (abbreviation) 285
Cable abbreviation Li12YC11Y-HF
Conductor cross section 4x 2x 0.25 mm² (signal line)
1x 0.25 mm² (Drain wire)
AWG signal line 24
Conductor structure signal line 32x 0.10 mm
Wire colors white-brown, green-yellow, gray-pink, blue-red
Twisted pairs 2 cores to the pair
Overall twist 4 pairs for core
Shielding Tinned copper braided shield
Optical shield covering 85 %
External sheath, color Gray RAL 7001
External cable diameter D 7.6 mm ± 0.2 mm
Minimum bending radius, flexible installation 7.5 x D
Number of bending cycles 3000000
Bending radius 100 mm
Traversing path 1.2 m
Traversing rate 1.4 m/s
Acceleration 2 m/s²
Outer sheath, material PUR
Material conductor insulation PES
Conductor material Bare Cu litz wires
Insulation resistance ≥ 100 MΩ*km
Nominal voltage, cable 350 V
Test voltage, cable 1200 V
Special properties Low adhesion surface
wear-resistant and notch tough
Resistance to oil very good oil and chemical resistance
https://www.phoenixcontact.com/us/products/1574551
11.11.2013Page3/4
Sensor/Actuator cable-SAC-8P-MS/10,0-285 SH SCO-1574551
Technical data
Cable
Other resistance ozone and UV resistant
Ambient temperature (operation) -50 °C ... 80 °C (cable, fixed installation)
-40 °C ... 80 °C (cable, flexible installation)
Classifications
eCl@ss
eCl@ss 4.0 27060306
eCl@ss 4.1 27060306
eCl@ss 5.0 27061801
eCl@ss 5.1 27061801
eCl@ss 6.0 27061801
eCl@ss 7.0 27061801
ETIM
ETIM 3.0 EC001855
ETIM 4.0 EC001855
ETIM 5.0 EC001855
UNSPSC
UNSPSC 6.01 31251501
UNSPSC 7.0901 31251501
UNSPSC 11 31251501
UNSPSC 12.01 31251501
UNSPSC 13.2 31251501
Drawings
Schematic diagram
6 4
7 3
1 2
5
8
Pin assignment M12 plug, 8-pos., view plug side
Cable cross section
PUR, gray, shielded[285]
https://www.phoenixcontact.com/us/products/1574551
11.11.2013Page4/4
Sensor/Actuator cable-SAC-8P-MS/10,0-285 SH SCO-1574551
Dimensioned drawing
47,3
Ø12
Ø14,8
M12
Plug, M12 x 1, straight, shielded
Circuit diagram
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
Contact assignment of M12 connector/socket
© Phoenix Contact 2013 - all rights reserved
http://www.phoenixcontact.com