Series KD/LD 10A, 60Vdc Optically Isolated, Short-Circuit Protected DC Solid-State Relay Part Number* Relay Description KD00CK 5A Solid-State Relay (SSR) KD02CK 5A SSR with Switch Status KD20CK 5A SSR with Short-Circuit Protection KD22CK 5A SSR with Short-Circuit Protection and Switch Status FEATURES LD00CM 10A Solid-State Relay LD02CM 10A SSR with Switch Status LD20CM 10A SSR with Short-Circuit Protection LD22CM 10A SSR with Short-Circuit Protection and Switch * Available with short-circuit/current overload protection * Available with switch status output * TTL and CMOS compatible control * Low ON resistance power FET output * Fast switching speed * Meets 28 Vdc system requirements of MIL-STD-704 * Optical isolation * Low profile hermetic package * Built and tested to the requirements of MIL-PRF-28750 Status * The Y suffix denotes parameters tested to MIL-PRF-28750 specifications. The W suffix denotes parameters tested to Teledyne specifications. ELECTRICAL SPECIFICATIONS (-55C TO +105C UNLESS OTHERWISE NOTED) INPUT (CONTROL) SPECIFICATION DESCRIPTION When used in 2 terminal configuration (TTL or direct control) (See Fig. 1) Min Typ Max Units Input Current @ VBIAS = 5 Vdc (See Fig. 2) 15 mAdc Turn-Off Voltage (Guaranteed Off) 1.5 Vdc Turn-On Voltage (Guaranteed On) 3.8 Vdc Reverse Voltage Protection Input Supply Range (See Note 1) 3.8 -32 Vdc 32 Vdc INPUT (CONTROL) SPECIFICATION When used in 3 terminal configuration (CMOS or open collector TTL) (See Fig. 1) Min Typ Max Units Control Current VCONTROL = 5 Vdc 250 Adc VCONTROL = 18 Vdc 1 mAdc 0 18 Vdc 3.8 32 Vdc 16 mAdc Control Voltage Range Bias Supply Voltage (See Note 1) Bias Supply Current Turn-Off Voltage (Guaranteed Off) Turn-On Voltage (Guaranteed On) (c) 2002 TELEDYNE RELAYS 3.2 Vdc 0.3 Vdc The Series KD and LD solid-state relays are screened utilizing MIL-PRF-28750 test methods and are packaged in low profile hermetically sealed cases. These relays are constructed with state-of-theart solid state techniques and feature fully floating power FET output technology. This allows the load to be connected to either output terminal and provides a low ON resistance. The input (control) and output are optically isolated to protect input logic circuits from output transients. Available options include short circuit and current overload protection, which provides complete protection for both the relay and system wiring. This feature not only provides protection should a short or overload occur while the relay is on, but will also provide protection should the relay be switched into a short. The second option is a status output line. Switch status returns the true status of the output switch and is optically isolated from the load. It provides status indication independent of the control circuit of the relay. The status line provides a logic 0 (low) when the relay output is off with load voltage and continuity present, and a logic 1 (high) when the output is on. (800) 284-7007 * www.teledynerelays.com KD/LD 51 KD/LD\072002\Q1 Series KD/LD OUTPUT (LOAD) SPECIFICATIONS (See Note 2) Min BLOCK DIAGRAM Typ Max Units Continuous Load Current (See Fig. 3) KD and LD series without heat sink 5 Adc LD series with heat sink 10 Adc KD00CK, KD20CK 100 A LD00CM, LD20CM 100 A KD02CK, KD22CK 2 mA LD02CM, LD22CM 2 mA KD00CK, KD02CK .60 Vdc KD20CK, KD22CK .70 Vdc LD00CM, LD02CM @10A 1.2 Vdc LD20CM, LD22CM @10A 1.4 Vdc Continuous Operating Load Voltage 60 Vdc Transient Blocking Voltage @25C 80 Vdc Leakage Current @ VLOAD=60Vdc Output Voltage Drop ON Resistance, ILOAD = 100 mA, TJ = 25C, (See Note 3) NO STATUS KD00CK, KD02CK .075 Ohm LD00CM, LD20CM .075 Ohm KD20CK, KD22CK .100 Ohm LD20CM, LD22CM .100 Ohm Turn-On Time (See Fig. 5) 5 ms Turn-Off Time (See Fig. 5) 2 ms Electrical System Spike @25C Vpk 600 Output Capacitance at 25 Vdc, 100 KHz MECHANICAL SPECIFICATION 1600 pF Isolation (Input to Output) KD00CK, KD20CK 10 pF LD00CM, LD20CM 10 pF KD02CK, KD22CK 15 pF LD02CM, LD22CM 15 pF Dielectric Strength Insulation Resistance @ 500 Vdc 1000 Vac 109 Ohms Output Junction Temperature 130 C Maximum Junction Temperature 150 C Thermal Resistance Junction to Ambient (JA) 30 C/W Thermal Resistance Junction to Case (JC) 7 C/W @ ILOAD = Imax rated KD/LD 52 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE (c) 2002 TELEDYNE RELAYS KD/LD\072002\Q1 Series KD/LD ENVIRONMENTAL SPECIFICATIONS Min Typ Max Units Temperature Range Operating -55 +105 C Storage -55 +125 C 10 3000 Hz Constant Acceleration 5000 g Shock 1500 g Vibration 100 g 0.5 ms pulse STATUS OUTPUT TRUTH TABLE (KD02CK, LD02CM, KD22CK, LD22CM) Control Voltage Relay Output State Status Output Level High Off Low (VSO 0.4 Vdc) Low On High (VSO = VSTATUS) STATUS OUTPUT SPECIFICATIONS (KD02CK, LD02CM, KD22CK, LD22CM) Min Typ Status Supply Voltage Max Units 30 Vdc @16Vdc 10 Adc @30Vdc 100 Adc Status (sink) Current (VSO < 0.4 Vdc) 600 Adc Status Turn-On Time (See Fig. 6) 3.5 ms Status Turn-Off Time (See Fig. 6) 8.0 ms Status Leakage Current BIAS (INPUT) CURRENT VS BIAS (INPUT) VOLTAGE FIGURE 2 (See Note 1) (c) 2002 TELEDYNE RELAYS (800) 284-7007 * www.teledynerelays.com WIRING CONFIGURATIONS FIGURE 1 (See Note 1) KD/LD 53 KD/LD\072002\Q1 Series KD/LD LOAD CURRENT DERATING CURVE FOR KD/LD SERIES WITHOUT A HEAT SINK (A) NORMALIZED ON RESISTANCE VS JUNCTION TEMPERATURE OVERLOAD CURRENT VS TIME TO TRIP (TYPICAL) KD20CK, KD22CK, LD20CM, LD22CM FIGURE 4 (See Note 3) FIGURE 7 OUTPUT TURN-ON AND TURN-OFF TIMING FIGURE 5 LOAD CURRENT DERATING CURVE FOR LD SERIES (B) SERIES LIMIT BIAS RESISTOR VS BIAS VOLTAGE THERMAL DERATING CURVES FIGURE 8 (See Note 1) FIGURE 3 STATUS TURN-ON AND TURN-OFF TIMING FIGURE 6 NOTES: 1. Control input is compatible with CMOS or open collector TTL (with pull up resistor). For bias voltages above 6V, a series resistor is required. Use the standard resistor value equal to or less than the value found in Figure 8. 2. The rated input voltage is 5V for all tests unless otherwise specified. 3. To calculate the maximum ON resistance for a given junction temperature, find the normalized ON resistance factor (NR) from Figure 4. Calculate the new ON resistance as follows: R(ON) = NR * RON @ 25C (KD00CK, LD00CM, KD02CK, LD02CM) R(ON) = NR(RON @ +25C ) + .025 ohm (KD20CK, LD20CM, KD22CK, LD22CM) 4. Overload testing to the requirements of MIL-PRF-28750 is constrained to the limits imposed by the short circuit protection characteristics as defined in this specification. System series inductance for "shorted-load" mode of operation should be 50 H. Maximum repetition rate into a shorted load should not exceed 10 Hz. 5. A status pull up resistor is required for proper operation of the status output. Determine the current (Iso) required by the status interface. Calculate the current (Is) through the status resistor such that the sink current through the status output is 0.6 mA. Select the status resistor such that it does not allow more than 0.6 mA to flow through the status output. RSTATUS = VSTATUS - 0.4V Iso 6. Inductive loads should be diode suppressed. Input transitions should be 1 ms duration and the input drive should be a bounceless contact type. KD/LD 54 TYPICAL TRIP CURRENT CHARACTERISTICS FOR SHORT CIRCUIT CONDITIONS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE FIGURE 9 (c) 2002 TELEDYNE RELAYS KD/LD\072002\Q1 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Teledyne Relays: KD20CKW LD00CMW LD02CMY KD20CKY KD44CFW LD20CMW KD00CKY LD22CMY LD20CMY KD00CKW KD02CKW LD02CMW KD02CKY KD22CKW KD44CFY LD22CMW LD00CMY KD22CKY