Installation Information
UL Recognized and CSA Certified for use on stranded copper
(AWG) wire only.
Strip away the end 3/8 inch of wire insulation.
Make the crimp in the proper station of a recommended 3M
crimp tool: TH-450 (scissor style) hand tools.
ScotchlokTerminals
MU18-6R/FLAG thru MU14-10R/FLAG
Ring Tongue, Non Insulated, Butted Seam, Flag
Data Sheet
Specifications
Wire Size: See Table Above
Barrel Seam: Butted
Maximum Current: Same as Wire
Terminal Material: Brass
Plating: Tin
LISTED 314R
UNDERWRITERS
LABORATORIES
STANDARD NO. UL 486A
3M FILE NO. E23438
CANADIAN STANDARDS
ASSOCIATION
STANDARD NO. 22.2
NO. 0, 65
3M FILE NO. LR22190
Barrel Crimp (Required)
W
CL
eriW rebmuNtcudorP egnaR )GWA( dutS eziSWCL ssenkcihT lerraB htgneL lerraB .D.I
GALF/R6-81UM81-22683.043.066.0030.062.0070.0
GALF/R01-41UM41-610183.043.096.0030.052.0090.0
WARNING
Turn power off before installing or removing terminal. All electrical
work should be done according to appropriate electr ical codes.
Electrical Products Division
6801 River Place Blvd.
Austin, TX 78726-9000
800 245 3573
http://www.3M.com/elpd Litho in USA.
© 3M 2002 78-8125-9795-9-A
IMPORTANT NOTICE
Before using this product, you must evaluate it and determine if it is suitable for your intended application. You assume all risks and liability
associated with such use.
Warranty; Limited Remedy; Limited Liability. This product will be free from defects in material and manufacture as of the date of
purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. If this product is defective within the warranty period stated above,
your exclusive remedy shall be, at 3M’s option, to replace or repair the 3M product or refund the purchase price of the 3M product. Except
where prohibited by law, 3M will not be liable for any loss or damage arising from this 3M product, whether direct, indirect,
special, incidental or consequential regardless of the legal theory asser ted.
Engineering Specification
Crimp-type terminals shall, electrically and
mechanically, connect permanently to a prestripped
end of a stranded copper wire, and have a flat tongue
portion with a central opening for mounting around a
screw or stud.
The terminal line shall offer tongue variations in hole
(stud) size (6, 8, 10) and configuration (ring, fork,
block fork, flanged block fork, locking fork, etc..) and
barrel variations in wire (AWG) range (22-18, 16-14,
12-10) and construction (non insulated brazed seam,
vinyl insulated butted seam, nylon insulated with
insulation grip, etc). The terminal line shall be marked
with the wire range and a manufacturer’s symbol.()
The non-insulated butted seam ring tongue terminal
shall be tin plated, annealed copper, with the tongue
having a specified stud hole (6 and 10) and with a
butted seam barrel having a beveled I.D. for ease of
stranded wire entry and sized for a specified (AWG)
wire range.
Non-Insulated terminals shall be UL Listed and CSA
Certified.
3M and Scotchlok are trademarks of 3M.
is a trademark of Underwriters Laboratories.
is a trademark of Canadian Standards Association.