Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Enhanced Differential Mode Performance K Series RFI Line Filters DK Series DK3 UL Recognized CSA Certified VDE Approved DK1 DK6 DK Series Specifications * Higher performance Line to Line attenuation than the K Series * E version meets the low leakage current requirements of VDE portable equipment and non-patient care equipment * V version features same high performance with more cost-effective design Ordering Information Maximum leakage current each Line to Ground: VDK Models EDK Models .4 mA .7 mA .22 mA .38 mA @ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 E DK 3 Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 1 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 DK Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 1, 3, 6, 10, or 20A Electrical Schematic LINE LOAD Available Part Numbers 1VDK1 1VDK3 3VDK1 3VDK3 6VDK1 6VDK3 10VDK1 10VDK3 20VDK1 20VDK6 1EDK1 1EDK3 3EDK1 3EDK3 6EDK1 6EDK3 10EDK1 10EDK3 20EDK1 18 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Enhanced Differential Mode K Series RFI Power Line Filters (continued) DK Series Case Styles VDK1 / EDK1 20VDK6 E 1 C D D RFI Power Line Filters E B B A A C VDK3 / EDK3 E D C Blue Case Dimensions Brown B Brown Green/ Yellow A 20VDK1 / 20EDK1 E D B B C 1VDK3, 1EDK3 3VDK1, 3EDK1, 6VDK1, 6EDK1 3VDK3, 3EDK3, 6VDK3, 6EDK3 10VDK1, 10EDK1 10VDK3, 10EDK3 20VDK1, 20EDK1 20VDK6 1VDK1, 1EDK1 D E C A A Part No. Blue 19 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Enhanced Differential Mode K Series RFI Power Line Filters (continued) DK Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1 & 3VDK 6, 10, 20VDK 1 & 3EDK 6, 10, 20EDK db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 20 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com