Manual Switches Series 2
Pushbutton Switches and Indicators
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada105
FEATURES
1Easy-to-assemble modules provide
thousands of display/control
combinations
1Up to 4 incandescent lamps
11, 2, 3, or 4-section display
1Transmitted or projected color
1Integral hold-in coil option provides
remote released contacts. Pull-in coils
(flange mount only) enable remote
actuation
1Switch guard accessory.
CHANGE LAMPS OR FILTERS
FROM PANEL FRONT
Without tool. Remove display screen/
lampholder assembly from 2C200 oper-
ator-indicator (or 2F200 indicator). Unit is
keyed to maintain proper orientation
when replacing. Use only flange base
T-134lamps with 2C200 and 2F200 de-
vices.
LAMPS AND FILTERS
Order lamps and filters for projected color
from page 111.
BARRIER MOUNT
Display screen
(page 115)
Housing
(next page)
Mounting barrier
(next page)
Switch unit
(page 114)
Mounting barriers attach to either the long
or short sides of the housing. They have
spring clips which grip the panel. Mount-
ing barriers also separate display screens
to protect against inadvertent operation.
Multiple units can be attached together in
a strip and snapped into a panel slot; or
they can be mounted individually.
FLANGE MOUNT
Display screen
(page 115)
Housing
(page 113)
Switch
unit
(page 114)
Flange mount units have mounting clips
ready-attached to the housing. They can
be individually installed or replaced; and
enable use of an overlay panel, if desired.
Groupings can be separated by optional
spacing barriers.
MODULES ASSEMBLE EASILY
All modules are ordered as separate
items which snap together for easy as-
sembly.
Pushbuttons
Manual Switches Series 2
Pushbuttons Switches and Indicators
106Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
Barriers on long sides
Barriers on short sides
BARRIER MOUNT MODULES
Barrier mount assemblies are identical in
panel appearance. Operator-indicator
housings have spring clips for attaching
switch modules. This feature is not pro-
vided with indicator housings.
Barriers are necessary for mounting.
They can be specified for attachment to
the long or short side of the housing, as
stated in the order guides.
BARRIER MOUNT HOUSING ORDER GUIDE
See ‘‘Application Data’’ for typical bailing circuits for coil-equipped modules.
Tool Not RequiredBarriers
Attach On:
No. of
Lamp Sockets Operator-Indicator Indicator Only
Long Sides
of Housing
2 (A & C) 2C207
4 (A-D) 2C209
Short Sides
of Housing
2 (A & C) 2C201
4 (A-D) 2C203 2F203
MOUNTING BARRIER ORDER GUIDE
For strip mounting, specify one more barrier than the number of units in the group.
Catalog ListingsMounting Barrier For Panel
Type Thickness Gray Black
Attach to
Long Sides .06-.19 in. (1,52-4,83 mm) 2B2 2B4
Attach to
Short Sides .06-.19 in. (1,52-4,83 mm) 2B1 2B3
Note: Panels .19 in. (1,52 mm) thick require the .06-.19 in. (1,52-4,83 mm) type barriers.
Manual Switches Series 2
Pushbutton Switches and Indicators
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada107
Flanges on long sides
FLANGE MOUNT MODULES
Flange mount assemblies are identical in
panel appearance. Operator-indicator
housings have spring clips for switch
modules attachment (not provided with
indicator housings).
Barriers are not required, since the panel
mounting clips are ready-attached to
flange sides of the housings. However,
spacing barriers can be used for color-
coding. They also aid in preventing inad-
vertent operation of two screens with one
push.
Mounting dimensions on page 114.
FLANGE MOUNT HOUSING ORDER GUIDE
See ‘‘Application Data’’ for typical bailing circuits for coil-equipped modules.
Tool Not Required
Flanges On:
No. of Lamp
Sockets
Operator-
Indicator Indicator Only
Long Sides of
Housing
2 (A & C) 2C204
4 (A-D) 2C206 2F206
SPACING BARRIER ORDER GUIDE
For .06-31 in. (1,5-7,9 mm) thick panels.
Catalog ListingsSpacing Barrier
Type Gray Black
For Long Flange Housing 2B9 2B18
Pushbuttons
Manual Switches Series 2
Pushbutton Switches and Indicators
108Honeywell1HSensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
SWITCH MODULES
Interchangeable type 2D switch modules
attach to spring clips on the bottom of
operator-indicator housings. There is a
wide selection of circuitry, electrical rat-
ings, operating actions and terminations.
For mounting dimensions, see page 115.
ELECTRICAL RATING
Silver contacts:
30 VDC: 5 amps res. sea level or 50,000 ft,
3 amps ind. sea level, 2.5 amps 50,000 ft.
Max. inrush, 24 amps.
UL and CSA rating for basic switch: 5
amps, 125 or 250 VAC.
Gold contacts:
30 VDC: 0.5 amp ind.,1amp res., sea level
and 50,000 ft. Max. inrush, 2 amps.
SM SUBMINIATURE MULTI-SPDT SWITCH MODULES
Momentary action Alternate action
SM switch modules offer a choice of two
momentary action styles, one with a pro-
nounced touch-feedback, the other with
low operating force for rapid repeat ac-
tuation. Also available with alternate-
action and combination momentary/
alternate action modules. Extra length
turret solder terminals.
SM SWITCH MODULE ORDER GUIDE
Momentary Action Alternate Action
Touch-Feedback Type Low Force TypeNo. of
SPDT Circuits Silver Contacts Silver Contacts
1 2D100 2D118
2 2D2 2D26
4 2D9 2D33
V3 COMPACT SPDT/DPDT SWITCH MODULES
V3 switch modules have screw terminals
with lockwashers. Quick-connect termi-
nals (not shown) are also available. When
used with short-flange operator indica-
tors, add spacing barriers to prevent
interference.
ELECTRICAL RATING
30 VDC: 10 amps ind.* sea level, 6 amps
ind.,* 50,000 ft. Motor load, 6 amps.** UL
and CSA rating for basic switch: 10 amps,
13Hp, 125 or 250 VAC; 12amp, 125 VDC;
14amp, 250 VDC.
* Inductive currents in accordance with AN3179.
** Motor load rating based on starting current.
V3 SWITCH MODULE ORDER GUIDE
No. of SPDT
Circuits Momentary Action
1 2D70
2 2D72
Manual Switches Series 2
Pushbutton Switches and Indicators
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada109
ONE-PIECE DISPLAY
SCREEN OPTIONS
Single-section
These translucent solid color display
screens are single-section/one piece
construction
SINGLE-SECTION/
ONE-PIECE SCREENS ORDER GUIDE
Colors Standard
Red 2A1
Yellow 2A2
Green 2A3
White 2A5
THREE-PIECE DISPLAY
SCREEN OPTIONS
Single-section
These screens have transparent colored
or colorless caps, transparent colorless
legend inserts and translucent colored
bases.
SINGLE-SECTION/THREE-PIECE
SCREENS ORDER GUIDE
Colorless
Color Caps
Red 2A81
Yellow 2A82
Green 2A85
White 2A70
Amber 2A114
NOTE:
Add –L to catalog listing if button is to be
legended.
Silicone rubber baffles prevent light spillage
from one section to another. Screen caps and
legend inserts are transparent colorless. Bases
are translucent colored.
For more information on 2, 3, and 4-section
display screens, contact the MICRO SWITCH
Application Center.
Pushbuttons
Manual Switches Series 2
Pushbutton Switches and Indicators
110Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
Manual Switches Series 2
Pushbutton Switches and Indicators
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada111
LEGEND INFORMATION
Honeywell MICRO SWITCH Division pro-
vides legend service on the inserts sup-
plied with three-piece screens only. To
specify your needs, add -Lto the catalog
listings (example: 2A81-L) and use Leg-
end Order Sheet (Form FO-62308),
shown on facing page. Reproduce it on
your office copier.
On any one insert, only one size of type is
provided in either black or white. After
legending, the insert is assembled to the
display screen. The type face used is
‘‘Modified Gothic’’.
LAMPS
T-134incandescent lamps are available
from MICRO SWITCH in 28 volt versions.
Use of neon lamps is not recommended.
Light output is approximately 30% of an
incandescent lamp. Also, a neon lamp
will not illuminate blue or green filters or
display screens due to the absence of
these colors from the neon light spec-
trum.
LAMP POLICY
The 28 volt lamps are offered as a conve-
nience to customers. Honeywell MICRO
SWITCH Division does not extend any
warranty as to such lamps, and cannot
guarantee to provide lamps from specific
manufacturers. Any technical or quality
questions regarding such lamps should
be directed to the lamp manufacturer.
COLOR FILTERS FOR PROJECTED
COLOR
Projected color is achieved by using
white buttons and color filters over clear
lamps. When lamps are lighted, white
button takes on color projected by the
filters.
Filters used with type 2C200 and 2F200
housings (no-tool relamping) slip over
lamp sockets in lampholder.
SCREEN/LEGEND COLORS
The chart below shows recommended
display screen and legend color combi-
nations for optimum legibility.
Legend Lettering
Screen
Color Black White
Red x
Green x
Yellow x
Amber x x
White x
LAMP ORDER GUIDE
Rating Life/Voltage†
Catalog Base Type Life in Expected
Listing Style No. Volts Amps Hours Volts Life (Hrs.)
2E1 Flange 327 28 .040 1000 24.0 7,500
26.0 2,800
30.0 400
These are experimental continuous life test results supplied by a lamp manufacturer for reference only.
Intermittent operation may reduce these figures as much as 50%. Ratings are based on median values of
current and life.
Wattage should not exceed 2.4 watts (2 lamps) per switch, for continuous illumination.
FILTER ORDER GUIDE
Filter Style Red Green Amber White*
For Type 2C200 and 2G12 2G14 2G16 2G17
2F200 Housings
* Has blue tint to compensate for high yellow content of incandescent lamps at low voltages.
Pushbuttons
Manual Switches Series 2
Pushbutton Switches and Indicators
112Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
SWITCH GUARD ACCESSORY
A hinged cover on the switch guard helps
avoid inadvertent operation of the display
screen. It is installed in place of the trans-
parent slide-on cap furnished with three-
piece screen. Note: When used with pull-
in coil devices, specify the 2C200 oper-
ator-indicator housings which have the
no-tool relamping feature.
Barrier mount assembly with guard in-
stalled. (Can also be used with all flange
mount units.)
Guard requires a ‘‘lift-to-push’’ response
to operate switch normally.
Order Catalog Listing 2H20
Key: 0,0 =mm
0.00 =inches
Manual Switches Series 2
Pushbutton Switches and Indicators
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada113
MOUNTING DIMENSIONS (For reference only)
Long barrier operator-indicators Short barrier operator-indicators
Short barrier indicators Long barrier indicators Mounting barriers
Short Long
0,0 =mm
Key: 0.00 =inches.
A Panel Thickness
1,5/.06 1,5-4,81/.06-.19
4,6/.18 4,8-7,9/.19-.31
Length Of Panel Cutout*
Number of Units
Type of Indicator or
Operator-Indicator 1 2 3 4 5 6 7
Short mm 36,09 68,00 99,87 131,72 163,60 195,48 227,36
Barrier in. 1.421 2.677 3.932 5.186 6.441 7.696 8.951
Long mm 30,00 55,78 81,58 106,34 133,12 159,90 184,68
Barrier in. 1.181 2.196 3.212 4.226 5.241 6.256 7.271
*Nominal dimensions, ±0,25 mm/0.10 in. (In 5% of
the cases, the cutout will be undersized for the build-
up of assembled units and will require enlargement.
Pushbuttons
Manual Switches Series 2
Pushbutton Switches and Indicators
114Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
MOUNTING DIMENSIONS (For reference only)
Long flange
operator-indicators
Long flange indicators Spacing barriers
Short Long
0,0 =mm
Key: 0.00 =inches.
Length Of Panel Cutout*
Add 4,19 mm/.165 in. to length for each optional spacing barrier used.
Number of Units
Type of Indicator or
Operator-Indicator 1 2 3 4 5 6 7
Long mm 27,94 55,75 83,57 111,36 139,17 166,98 194,77
Flange in. 1.1 2.195 3.290 4.384 5.479 6.574 7.668
*Nominal dimensions, ±0,25 mm/0.10 in. (In 5% of
the cases, the cutout will be undersized for the
build-up of assembled units and will require
enlargement.
Manual Switches Series 2
Pushbutton Switches and Indicators
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada115
MOUNTING DIMENSIONS (For reference only)
SM Switch Modules
V3 Switch Modules
Pushbuttons
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
2A1 2A5 2A85 2B18 2B2 2B4 2C204 2C206 2G12 2G16 2A114 2A85-L 2F206 2A81-L 2A82-L 2C209