5/15
ABB
5
Overall dimensions ...................... pag. 12/27
E 90
E 90 fuse-disconnectors
E 90 series fuse-disconnectors are designed for connecting and disconnecting circuits under load, providing
protection against short circuits and overloads. The case is made of self-extinguishing thermoplastic material
resistant to high temperatures (all materials are UL listed) while the contact clips are in silver plated copper.
E 90 fuse-disconnectors can be sealed or padlocked to ensure operator safety during maintenance.
Versions with blown fuse indicator allow to check whether the fuse is still working correctly or not. For
easy and quick installation E 90 range is fully compatible with connecting bars, terminals and caps of
S 200 MCBs
E 90 fuse-disconnectors for 10.3 x 38 mm fuses (AC-22B)
Poles Rated Modules Order Bbn Price Price Weight Pack
current details 8012542 1 piece group 1 piece unit
In Type code Order code EAN kg pc.
1 32 1 E 91/32 2CSM200923R1801 009238 0.061 6
1 32 1 E 91/32s 2CSM202483R1801 024835 0.062 6
1+N 32 2 E 91N/32 2CSM200893R1801 008934 0.130 3
2 32 2 E 92/32 2CSM200883R1801 008835 0.122 3
3 32 3 E 93/32 2CSM204753R1801 047537 0.183 2
3+N 32 4 E 93N/32 2CSM204733R1801 047339 0.252 1
4 32 4 E 94/32 2CSM204723R1801 047230 0.244 1
N 32 - E 9N 2CSM277953R1801 779537 0.069 6
s: version with blown fuse indicator light
E 90 fuse-disconnectors for 8.5 x 31.5 mm fuses (AC-22B)
1 20 1 E 91/20 2CSM200983R1801 009832 0.061 6
1 20 1 E 91/20s 2CSM202423R1801 024231 0.062 6
2 20 2 E 92/20 2CSM200953R1801 009535 0.122 3
3 20 3 E 93/20 2CSM200943R1801 009436 0.183 2
N 20 - E 9N 2CSM277953R1801 779537 0.069 6
s: version with blown fuse indicator light
Technical features
Type E 90/20 E 90/32
Fuse 8 x 32 10 x 38
Kind of current AC / DC
Rated frequency [Hz] = / 50-60
Rated current [A] 20 32
Tightening torque [Nm] PZ2 2-2.5
Protection degree IP20
Padlocked (open)
Sealed (closed)
IEC 60947-3
Rated operational voltage [V] 400 690
Utilization category AC-22B / DC-20B
Power consumption aM [W] 0.9 1.2
per polecnsuption per pole gG [W] 2.5 3.0
IEC 60269-1
Rated voltage AC [V] 400 690
Rated voltage DC [V] 400 690
IEC 60269-2
Fuse system F
Rated voltage AC [V] 400 690
Rated voltage DC [V] 250 440
Minimum rated breaking capacity 50 AC – 25 DC
IEC 60269-3
Fuse system B
Rated voltage AC [V] 400
System
pro M compact®
Selection tables
Protection devices
E 90 fuse-disconnectors
Product
available
starting from
2009
31.5 mm Ø 8.5 mm
38 mm Ø 10.3 mm
5/16 ABB
5
Electrical symbols
E 90
System
pro M compact®
Selection tables
Protection devices
E 90 fuse-disconnectors
Materials
Plastic parts Case: Material PA 6 +30% glass fibre
Self extinguishing class: V2 (UL94)
Temperature resistance: 130 °C
Opening handle Material PA 66 +25% glass fibre
Self-extinguishing class V0 (UL94)
Temperature resistance: 140 °C
Metal parts Clips Silver plated copper
Clip spring Stainless steel
Terminals Galvanized steel
Utilization category
Current type Utilization category Typical applications
Alternating current AC-20A - AC-20B Connecting and disconnecting under no load (in this case the
devices must be marked “Do not disconnect under load”)
AC-21A - AC-21B Switching of resistive loads, including moderate overloads
AC-22A - AC-22B Switching of mixed resistive/inductive loads,
including moderate overloads
AC-23A - AC-23B Switching of motors and other highly inductive loads
Direct current DC-20A - DC-20B Connecting and disconnecting under no load (in this case
the devices must be marked “Do not disconnect under load”)
DC-21A - DC-21B Switching of resistive loads, including moderate overloads
DC-22A - DC-22B Switching of mixed resistive / inductive loads,
including moderate overloads
DC-23A - DC-23B Switching of motors or other highly inductive loads
Suffix A Frequent use
Suffix B Infrequent use
1
2
3
4
2P
1
2
N
1P+N
1
2
1P
1
2
3
4
3P+N
5
6
N1
2
3
4
3P
5
6
N
N
1
2
3
4
4P
5
6
7
8
1234
Multi-pole coupling
Product
available
starting from
2009
5/17
ABB
5
E 90
E 90 range class CC fuseholders are appropriate to protect against overloads and short circuits.
They are designed for use with class CC cartridge fuses and they are available in 1P, 1P+N, 2P,
3P, 3P+N, 4P an N poles. Fuseholders can be safetly locked in open position and sealed in closed
position. E 90 range assure maximum protection against direct contancts thanks to IP20 finger-safe
protection degree. They are the ideal solution in industrial and process control systems, automated
systems, industrial systems and individual control circuits.
Versions with blown fuse indicator allow to
check whether the fuse is still working correctly or not.
E 90 for class CC cartridge fuses
Poles Rated Modules Order Bbn Price Price Weight Pack
current details 8012542 1 piece group 1 piece unit
In Type code Order code EAN kg pc.
1 30 1 E 91/30 2CSM205833R1801 058335 0,061 6
1 30 1 E 91/30s 2CSM251533R1801 515333 0,062 6
1+N 30 2 E 91N/30 2CSM200693R1801 006930 0,13 3
2 30 2 E 92/30 2CSM202443R1801 024439 0,122 3
3 30 3 E 93/30 2CSM200683R1801 006831 0,183 2
3+N 30 4 E 93N/30 2CSM202433R1801 024330 0,252 1
4 30 4 E 94/30 2CSM200673R1801 006732 0,244 1
N 30 1 E 9N 2CSM277953R1801 779537 0,069 6
s: version with blown fuse indicator light
Accessories for E 90 disconnector fuseholders
Order Bbn Price Price Weight Pack
details 8012542 1 piece group 1 piece unit
Type code Order code EAN kg pc.
E 90/ACP 2CSM205823R1801 058236 0,050 1
Technical features
30A
Rated voltage Un [V] 600 AC/DC
Rated current In [A] 30
Rated frequency [Hz] 50/60
Fuse dimensions [mm] 10,4 x 38,1
Tightening torque [lib-in] 18-22
Rated temperature [°C] 75
Sealability
Lockability
Marking UL CSA
Standards UL 512
System
pro M compact®
Selection tables
Protection devices
E 90 class CC fuseholders
Product
available
starting from
2009
38 mm Ø 10.4 mm
5/18 ABB
5
Overall dimensions ...................... pag. 12/27
E 90h
E 90h fuse holders
E 90h fuse holders are suitable for protection against overloads and short circuits. Available in a
single module 1P+N version and in a three-module 3P+N version, they are designed for use with
gG and aM cylindrical fuse links. The body is made from self-extinguishing material resistant to high
temperatures, while the contact clips are in silver-plated copper. E 90h fuse holders can be sealed
or padlocked to assure operator safety during maintenance.
Versions with blown fuse indicator allow to
check whether the fuse is still working correctly or not.
E 90h fuse holders for 10.3 x 38 mm fuses (AC-20B)
Poles Rated Modules Order Bbn Price Price Weight Pack
current details 8012542 1 piece group 1 piece unit
In Type code Order code EAN kg pc.
1+N 32 1 E 91hN/32 2CSM200913R1801 009139 0.070 6
1+N 32 1 E 91hN/32s 2CSM206573R1801 065739 0.071 6
3+N 32 3 E 93hN/32 2CSM204743R1801 047438 0.192 2
s: version with blown fuse indicator light
E 90h fuse holders for 8.5 x 31.5 mm fuses (AC-20B)
1+N 20 1 E 91hN/20 2CSM200963R1801 009634 0.070 6
1+N 20 1 E 91hN/20s 2CSM200703R1801 007036 0.071 6
3+N 20 3 E 93hN/20 2CSM200933R1801 009337 0.192 2
s: version with blown fuse indicator light
Accessories for E90 fuse disconnectors and for E 90h fuse holders series
- - - E 90/ACP 2CSM205823R1801 058236 0.118 1
System
pro M compact®
Selection tables
Protection devices
E 90h Fuse holders
Fuse indicator LED
Product
available
starting from
2009
Electrical symbols
1
2
N
1P+N
1
2
3
4
3P+N
5
6
N
31.5 mm Ø 8.5 mm
38 mm Ø 10.3 mm
Technical features
Type E 90h/20 E 90h/32
Fuse 8 x 32 10 x 38
Kind of current AC / DC
Rated frequency [Hz] = / 50-60
Rated current [A] 20 32
Power consumption aM [W] 0.9 1.2
per polensuption per pole gG [W] 2.5 3.0
Tightening torque [Nm] PZ2 2-2.5
Protection degree IP20
Padlocked (open)
Sealed (closed)
IEC 60269-1
Rated voltage AC [V] 400 690
Rated voltage DC [V] 400 690
IEC 60269-2
Fuse system F
Rated voltage AC [V] 400 690
Rated voltage DC [V] 250 440
Minimum rated breaking capacity 50 AC – 25 DC
IEC 60269-3
Fuse system B
Rated voltage AC [V] 400
5/19
ABB
5
Overall dimensions ...................... pag. 12/27
E 90 PV
E 90 PV fuse-disconnectors
E 90 PV series fuse-disconnectors, designed for operating voltages of 1000 V d.c. with utilization ca-
tegory DC-20B, are particularly suited for protection against overcurrents of photovoltaic systems.
The single-pole or two-pole E 90 PV disconnectors for 10.3 x 38 mm cylindrical fuse links offer a
reliable, compact and affordable solution for photovoltaic installations. Versions with blown fuse
indicator allow to check whether the fuse is still working correctly or not.
E 90 PV fuse-disconnectors for 10.3 x 38 mm fuses (DC-20B)
Poles Rated Modules Order Bbn Price Price Weight Pack
current details 8012542 1 piece group 1 piece unit
In Type code Order code EAN kg pc.
1 32 1 E 91/32 PV 2CSM204713R1801 047131 0,061 6
1 32 1 E 91/32 PVs 2CSM204693R1801 046936 0,062 6
2 32 2 E 92/32 PV 2CSM204703R1801 047032 0,122 3
s: version with blown fuse indicator light
Technical features
Type E 90/32 PV
Fuse 10 x 38
Kind of current DC
Rated frequency [Hz] = / 50-60
Rated Current [A] 32
Tightening Torque [Nm] PZ2 2-2.5
Protection degree IP20
Padlocked (open)
Sealed (closed)
IEC 60947-3
Rated operational voltage [V] 1000
Utilization category DC-20B
Power consumption aM [W] 1.2
per poleuption per pole gG [W] 3.0
System
pro M compact®
Selection tables
Protection devices
E 90 PV fuse-disconnectors
Application example of fuse disconnectors in photovoltaic system
Electrical symbols
Product
available
starting from
2009
1
2
3
4
2P
1
2
1P
38 mm Ø 10.3 mm
Lines protection
E 90 PV fuse-disconnectors allow overlo-
ad protection of each line, thus preventing
damage of critical plant components.
OVR Surge Protective Device protection
E 90 PV fuse-disconnectors can be
installed in field enclosure as back-up
protection of Surge Protective Device.
Inverter protection
In small photovoltaic plants, inverter pro-
tection against overload and short-circuit
is possible by means of E 90 PV.
+-
+-
+-
+-