108-1050
Test Description Requir ement Procedur e
Rev G 3 of 9
Vi br ati on, sinusoidal. No discont inuities of 1
m icr osecond or longer dur ati on.
See Note.
AMP Spec 109-21-1.
Subj ec t mated sampl es to 10- 55- 10
Hz tr aversed in 1 minut e at .06 inch
tot al excur si on. 2 hours in eac h of 3
m utual ly per pendicular planes.
Physic al shock. No discont inuities of 1 mi c r osecond
or l onger dur ati on.
See Note.
AMP Spec 109-26-1.
Subj ec t mated sampl es to 50 G's
half-sine shock pul ses of 11
milliseconds dur ati on. 3 shocks in
each di r ec ti on applied al ong 3
m utual ly per pendicular planes, 18
total shocks.
Durability. See Note. AMP Spec 109-27.
Manual ly mate and unmate
samples wit h fric tion lock header
f or 25 cycles.
Mating for c e. 2 pounds maximum average per
contact. AMP Spec 109-42, Condition A.
Measure force nec essary to mate
samples wit h fric tion lock header
from point of ini ti al contact to depth
of .200 inch at maxi mum r ate of . 5
inc h per minut e.
Unm ati ng force. 0.8 pound mini mum average per
contact. AMP Spec 109-42, Condition A.
Measure force nec essary to unmate
samples f r om fric tion lock header at
maximum rate of .5 inch per
minute.
ENVIRONMENTAL
Thermal shock. See Note. AMP Spec 109-22.
Subj ec t mated sampl es to 25
cycles between -55 and 105°C.
Hum idi t y-temperature cycling. See Note. AMP Spec 109-23-3, Condition B.
Subj ec t mated sampl es to 10
cycles between 25 and 65°C at
95% RH.
Temperature life. See Note. AMP Spec 109-43.
Subj ec t mated sampl es to
temperature li fe at 85°C for 1000
hours.
Mixed flowing gas. See Note. AMP Spec 109-85-3.
Subj ec t mated sampl es to
environmental class III for 20 days.
Shall meet v is ual r equir em ents, s how no phys ic al dam age and s hall m eet requirem ents of
NOTE
additional t es ts as s pec ified in Tes t Sequence in Figure 2.
Figure 1 (end)