9540 Non-Paired - Computer Cable for EIA RS-232 Applications
For more information please
call
1-800-Belden1
See Put-ups and Colors
Color Code Chart : No. 1.pdf
Description:
24 AWG stranded (7x32) tinned copper conductors, conductors cabled, semi-rigid PVC insulation, overall Beldfoil® shield (100%
coverage), 24 AWG stranded tinned copper drain wire, PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Conductors 10
Total Number of Conductors 10
AWG 24
Stranding 7x32
Conductor Material TC - Tinned Copper
INSULATION:
Insulation Material PVC - Polyvinyl Chloride
Nom. Insulation Wall Thickness .010 in.
OVERALL CABLING:
Overall Cabling Lay Length 2.125 in.
Overall Cabling Color Code Chart :
Number Color
1 Black
2 White
3 Red
4 Green
5 Brown
Number Color
6 Blue
7 Orange
8 Yellow
9 Purple
10 Gray
OUTER SHIELD:
Outer Shield Material Trade Name Beldfoil®
Outer Shield Material Aluminum Foil-Polyester Tape
Outer Shield %Coverage 100 %
Outer Shield Drain Wire AWG 24
Outer Shield Drain Wire Stranding 7x32
Outer Shield Drain Wire Conductor Material TC - Tinned Copper
Page 1 of
3
9540 Non-Paired - Computer Cable for EIA RS-232 Applications
OUTER JACKET:
Outer Jacket Material PVC - Polyvinyl Chloride
Outer Jacket Nominal Wall Thickness .032 in.
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter .244 in.
MECHANICAL CHARACTERISTICS:
Operating Temperature Range -30°C To +80°C
UL Temperature Rating 80°C (UL AWM Style 2464)
Bulk Cable Weight 36.5 lbs/1000 ft.
Max. Recommended Pulling Tension 55 lbs.
Min. Bend Radius (Install) 2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification CMG
CEC/C(UL) Specification CMG
AWM Specification UL Style 2464 (300 V 80°C)
EU CE Mark (Y/N) Yes
EU RoHS Compliant (Y/N) Yes
EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
FLAME TEST:
C(UL) Flame Test FT4
PLENUM/NON-PLENUM:
Plenum (Y/N) N
ELECTRICAL CHARACTERISTICS:
Nom. Capacitance Conductor to Conductor @ 1 KHz 30 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz 55 pF/ft
Nom. Conductor DC Resistance @ 20 Deg. C 25 Ohms/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg. C 18 Ohms/1000 ft
Max. Operating Voltage - UL 300 V RMS (UL AWM Style 2464)
Max. Recommended Current 1.75 Amps per conductor @ 25°C
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
9540 060100 10 #24 PVC FS PVC
100 4.3 CHROME
Page 2 of
3
9540 Non-Paired - Computer Cable for EIA RS-232 Applications
9540 0601000 10 #24 PVC FS PVC
1000 36 CHROME
C
9540 060500 10 #24 PVC FS PVC
500 18 CHROME
C
9540 060U1000 10 #24 PVC FS PVC
U1000 38 CHROME
9540 060U500 10 #24 PVC FS PVC
U500 19.5 CHROME
C = CRATE REEL PUT-UP.
Revision Number: 1 Revision Date: 05-25-2005
© 2005 Belden Wire & Cable Company
All Rights Reserved.
Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication,
information and specifications described herein are subject to error or omission and to change without notice, and the listing of such
information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California
Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS
(Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our
Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR
(Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as
reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its
publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any
other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality
specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of
legislation and regulations based on their individual usage of the product.
Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended
by directive 93/68/EEC.
Page 3 of
3