POWER
LPX100 Enclosure
Installation Notes LPX100 • Cover Enclosure Kit
LPX100 will t the LPX5X, LPX10X-M, NPX4X-M, NPX2X-M
and NPX6X-M power supplies.
MATERIALS
1 Base
1 Cover
4 M3x6mm Pan head screws with
spring washer
4 M3x6mm countersunk screws
1 M4 nut
1 M4 star washer
1 M4 spring washer
1 Plastic insulator sheet
Installation Instructions and Notes
1 Place the insulator over the chassis as shown.
2 Place the power supply over the insulator as shown.
3 Align the 4x power supply to the chassis standoff.
4 Secure 4 pan head screws with washer provided with in kit as shown.
5 Place the cover over the power supply as shown.
6 Align the 4x cover to the U-bracket countersink holes.
7 Secure 4 countersink screws provided with in kit as shown.
8 Overall dimensions: 4.685 (119.0) x 2.945 (74.8) x 1.693 (43.0).
9
Base plate has three sets of customer mountings:
a. Bottom mounting (4X) M3 inserts. Max. screw penetration 0.0787 (2mm)
b. Side mounting (2X) 4mm clear holes plus 2 keyways. (See keyway detail)
c. Side mounting (4X) M3 inserts. Max. screw penetration 0.236 (6mm)
10 Ensure insulator is correctly fitted in base under PCB to maintain safety creepage and
clearances.
11 Ensure base is firmly connected to supply earth via the earth stud marked.
12
When using this enclosure, ensure that relevant safety standards (e.g. EN60950) are
complied with, in respect to creepage and clearance distances, and distances through
insulation.
13 All dimensions are in inches (mm).
OUTPUT CONNECTOR
INPUT CONNECTOR
(4X)STANDOFF
GROUND STUD
INSULATOR
LPX100 Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
While every precaution has been taken to ensure accuracy and completeness in this literature, Artesyn
Embedded Technologies assumes no responsibility, and disclaims all liability for damages resulting from use of
this information or for any errors or omissions. Artesyn Embedded Technologies, Artesyn and the Artesyn
Embedded Technologies logo are trademarks and service marks of Artesyn Embedded Technologies, Inc. All other
names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners.
© 2014 Artesyn Embedded Technologies, Inc.
www.artesyn.com
Mechanical Drawing
LPX100 Rev. 11.07.14
1.457
37 ,0[ ]
1.260
32, 0[ ]
0. 98024, 9[ ]0. 80 220,4[ ]
2. 94 5
74,8[ ]
4.68 5119 ,0[ ]
1.693
43,0[ ]
(2X) 0.591
15,0[ ]
(2X) 2.67 768, 0[ ]
(2X) 1.004
25, 5[ ]
1.724
43 ,8[]
2. 20 5
56 ,0[ ]
2. 165
55,0[ ]
(2X) 0.390
9, 9[ ]
(2X) 2.28358,0[ ]
(2X) 3 .72794,7[ ]
(2X) 0.57714,7[ ]
(2X) 1.201 30,5[ ]
(2X) 0.1975,0[]
1.654
42, 0[ ]
(2X)M3 INSERT
(2X)M3 INSERT
AA
AA
(4X)M3 INSERT
MARK ED "A "SEE KE YWAY DETAILS
(2X) KE YWAY DETAI L
ÿ0 .14(ÿ3 .6)
ÿ0 .35( ÿ8 .8)
0. 25 (6.4)