Rev. 04.06.12_#98
LPS200-M Series
1 of 3
Embedded Power for
Business-Critical Continuity
LPS200-M Series
250 Watts
Special Features
• MedicalandITEsafeties
• Activepowerfactorcorrection
• 3”x5”footprint
• Lessthan1Uhigh
• EN61000-3-2compliant
• Remotesense
• Powerfail
• Adjustablemainoutput
• Built-inClassBEMIfilter
• Overvoltageprotection
• Overloadprotection
• Thermaloverloadprotection
• Isolated12VFanoutput
• LPX200enclosurekitavailable
Total Power: 125-250Watts
Input Voltage: 90-264Vac
# of Outputs: Single
Electrical Specifications
Safety
Input
Inputrange: 90-264Vac;120-300Vdc
Frequency: 47-63Hz
Inrushcurrent: 50Amax.,coldstart@25°C
Efficiency: 86%typicalatfullload
EMI/RFI: FCCClassBconducted;CISPR22ClassBconducted;
EN55022ClassBconducted;VDE0878PT3ClassBconducted
Powerfactor: 0.99typical
Safetyground
leakagecurrent:
275uA@50/60Hz,264Vacinput
Output
Maximumpower: 125Wforconvection(100WforLPS202-M);250W(200WforLPS202-M)
with30CFMforcedair
Adjustmentrange: ±10%minimumonthemainoutputs
Fanoutput: 12V@0.5Aconvection,@1Aforcedairisolated,±10%
Hold-uptime: 16ms@250Wload,120Vacinput
Overloadprotection: Shortcircuitprotectiononalloutputs.Caseoverloadprotected@110-160%
aboverating
Overvoltageprotection: 15-50%abovenominaloutput
LogicalControl
Powerfailure: Opencollectorlogicsignalgoeshigh100-500msecaftermainoutput;it
goeslowatleast6msecbeforelossofregulation
Remotesense: Compensatesfor0.5Vleaddropmin.Willoperatewithoutremotesense
connected.Reverseconnectionprotected.
• TUV 60950,60601-1
• UL 60950,60601-1
• cULus 60950,60601-1
• CB Certificate & report
• CE Mark(LVD)
Embedded Power for
Business-Critical Continuity
OrderingInformation
Model
Number
Output
Voltage
Minimum
Load
MaximumLoadwith
ConvectionCooling
MaximumLoadwith
30CFMForcedAir PeakLoad Regulation2Ripple
P/P(PARD)3
LPS202-M 5V 0A 20A 40A 44A ±2% 50mV
LPS203-M 12V 0A 10.3A 20.8A 22A ±2% 120mV
LPS204-M 15V 0A 8.3A 16.6A 18A ±2% 150mV
LPS205-M 24V 0A 5.2A 10.4A 11.5A ±2% 240mV
LPS208-M 48V 0A 2.6A 5.2A 5.8A ±2% 480mV
1. Peakcurrentlasting<30secondswithamaximum10%dutycycle.
2. At25°Cincludinginitialtolerance,linevoltage,loadcurrentsandoutputvoltagesadjustedtofactorysettings.
3. Peak-to-peakwith20mHzbandwidthand10µF(tantalumcapacitor)inparallelwitha0.1µFcapacitoratratedlinevoltageandloadranges.
Rev. 04.06.12_#98
LPS200-M Series
2 of 3
Operatingtemperature: 0°to50°Cambientderateeachoutputas2.5%perdegreefrom50°to70°C.-20°C
start up
Storagetemperature: -40°Cto+85°C
Electromagnetic
susceptibility:
DesignedtomeetEN61000-4;
-2,-3,-4,-5,-6,-8,-11Level3
Humidity: Operating;non-condensing10%to95%RH
Vibration: IEC68-2-6tothelevelsofIEC721-3-2
MTBFcalculated: 1millionhoursatfullloadand25°Cambientconditions.230Vacinput,Bellcore
EnvironmentalSpecifications
PinAssignments
Connector LPS200-M
SK1 Pin1 Neutral
Pin3 Line
SK2 TB-1 Common
TB-2 Mainoutput
SK3 Pin1 +V1Remotesense
Pin 2 -V1Remotesense
Pin3 N/C
Pin4 N/C
Pin 5 +Powerfail
Pin6 Common
Pin7 N/C
Pin 8 Common
Pin 9 +12VFan
Pin10 +12FanReturn(isolated)
MatingConnectors
ACInput(SK1): Molex09-50-3031(connector)
PINS:08-52-0072
ACGround: Molex01-90020001
DCOutput
(SK2):
Molex19141-0058/0063or19099-0044/0048
SpadelugbasedonCableAmpacity/AWG
ControlSignals
(SK3):
Molex90142-0010(USA)
PINS:90119-2110or
Amp:87977-3
PINS:87309-8
EmersonNetworkPowerConnectorKit#70-841-020,includesallofthe
above.
1. Specificationssubjecttochangewithoutnotice.
2. Alldimensionsininches(mm),toleranceis±0.02”(±0.5mm)
3. MountingholesMH1andMH2shouldbegroundedforEMIpurposes.
4. MountingholeMH1issafetygroundconnection.
5. Specificationsareforconvectionratingatfactorysettingsat115VAC
input,25°Cunlessotherwisestated.
6. Thispowersupplyrequiresmountingonmetal
standoffs0.20”(5m)inheight.
7. Warranty:2years
8. Weight:0.75lb/0.34kg
Rev. 04.06.12_#98
LPS200-M Series
3 of 3
Embedded Power for
Business-Critical Continuity
MechanicalDrawing
1.32
(33.6)
5.00
(127.0)
3.00
(76.2)
2.55
(64.8)
0.15 Dia.
(4)
4 Places
4.55
(115.6)
21
SK2
SK3
SK3
VR1
Output Voltage
Adjust Pot
0.197” (5.0)
Minimum
Standoff Height
5
110
MH1
MH2
31
SK1
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2010EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower