https://www.phoenixcontact.com/us/products/2806016 Differential current monitoring - RCM-A/50/85-264V - 2806016 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid (http://phoenixcontact.com/download) Differential current monitor in type A version for detecting pulsing AC and DC leakage currents at 50/60 Hz. Product Features Residual current detection characteristics type A (50/60 Hz) Detects pulsating DC and AC residual currents Adjustable residual response current of 30 mA to 3 A Adjustable pre-alarm threshold and delay time Actual residual current can be read via LED display Remote signaling for main and pre-alarm Residual current monitoring devices act as a form of fire prevention Key commercial data Packing unit 1 pc Weight per Piece (excluding packing) 200.0 GRM Custom tariff number 90303310 Country of origin Germany Technical data Dimensions Height 89.7 mm Width 71.6 mm Depth 62.2 mm Horizontal pitch 4 Div. Ambient conditions Degree of protection IP20 09/10/2014 Page 1 / 5 https://www.phoenixcontact.com/us/products/2806016 Differential current monitoring - RCM-A/50/85-264V - 2806016 Technical data Ambient conditions IP40 (distributor installation with cover) Ambient temperature (operation) -25 C ... 65 C Ambient temperature (storage/transport) -40 C ... 85 C General Housing material Polycarbonate Mounting type DIN rail: 35 mm Common characteristics Nominal voltage UN 85 V AC ... 264 V AC Nominal frequency fN 50 Hz (60 Hz) Current consumption < 4 VA Max. required back-up fuse 16 A (B) Rated response differential current Idyn 3A Differential current acquisition characteristic Type A (50 / 60 Hz) Response differential current In 30, 100, 300, 1000, 3000 mA (adjustable) Discrimination threshold main alarm 80 % ... 100 % (of the set response differential current In) Discrimination threshold pre-alarm 10 % ... 90 % (of the main alarm threshold, adjustable) Response time for 2 x In 0.1 s ... 1 s (adjustable) Rated surge voltage resistance Uimp 4 kV Surge voltage category III Rated voltage Un 230 V AC Pollution degree 2 Connections Connection method Screw terminal blocks Tightening torque 0.6 Nm Stripping length 8 mm Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 2.5 mm Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Conductor cross section AWG/kcmil min. 24 Conductor cross section AWG/kcmil max 12 Min. conductor cross section, stranded, with ferrule 0.25 mm Max. conductor cross section, stranded, with ferrule 2.5 mm Remote indication contact Connection name Pre-alarm 09/10/2014 Page 2 / 5 https://www.phoenixcontact.com/us/products/2806016 Differential current monitoring - RCM-A/50/85-264V - 2806016 Technical data Remote indication contact Switching function PDT contact Connection name Main alarm Switching function PDT contact Conductor cross section stranded min. 0.2 mm Conductor cross section stranded max. 2.5 mm Conductor cross section solid min. 0.2 mm Conductor cross section solid max. 4 mm Maximum operating voltage Umax. AC 230 V AC Max. operating current Imax 5 A (cos phi > 0.9) Max. required back-up fuse 4 A (gL) Standards and Regulations Standards/specifications DIN EN 62020 DIN EN 60664 Classifications eCl@ss eCl@ss 4.0 27371105 eCl@ss 4.1 27371105 eCl@ss 5.0 27371802 eCl@ss 5.1 27371802 eCl@ss 6.0 27371802 eCl@ss 7.0 27371802 eCl@ss 8.0 27371802 ETIM ETIM 2.0 EC001440 ETIM 3.0 EC001440 ETIM 4.0 EC001440 ETIM 5.0 EC001440 UNSPSC UNSPSC 6.01 30211916 UNSPSC 7.0901 39121535 UNSPSC 11 39121535 UNSPSC 12.01 39121535 UNSPSC 13.2 39121535 09/10/2014 Page 3 / 5 https://www.phoenixcontact.com/us/products/2806016 Differential current monitoring - RCM-A/50/85-264V - 2806016 Approvals Approvals Approvals VDE Zeichengenehmigung Ex Approvals Approvals submitted Approval details VDE Zeichengenehmigung Drawings Dimensioned drawing Circuit diagram 89,7 11,1 11,1 k l A1 A2 12 14 = 11 Alarm 12 14 11 4,7 71,6 62,2 Pre-alarm 09/10/2014 Page 4 / 5 https://www.phoenixcontact.com/us/products/2806016 Phoenix Contact 2014 (c) - all rights reserved http://www.phoenixcontact.com 09/10/2014 Page 5 / 5