G7SA
2
Slim Plug-In Safety Relay
Slim Safety Relay for Machine
Control
HSlim body only 13 x 24 x 50 mm
(six poles)
HFour-pole and six-pole models are
available
HTerminal arrangement simplifies PCB
pattern design
HPositive, force-guided contacts
HDIN rail-mounting and panel-mounting
sockets available
Ordering Information
JSAFETY RELAYS
Number of contacts NO contacts NC contacts Contact form Part number
4 poles 3 1 3PST-NO, SPST-NC G7SA-3A1B
p
2 2 DPST-NO, DPST-NC G7SA-2A2B
6 poles 5 1 5PST-NO, SPST-NC G7SA-5A1B
p
4 2 4PST-NO, DPST-NC G7SA-4A2B
3 3 3PST-NO, 3PST-NC G7SA-3A3B
JACCESSORIES
Description Part number
Mounting sockets DIN-rail mounting and screw mounting 4 poles P7SA-10F
g
g
g
6 poles P7SA-14F
DIN-rail mounting and screw mounting with
L
E
D
i
d
i
t
4 poles P7SA-10F-ND
g
g
LED indicator 6 poles P7SA-14F-ND
PCB terminal 4 poles P7SA-10P
6 poles P7SA-14P
G7SA
3
Specifications
JRATINGS
Operation Coil
Number of
contacts
Rated
voltage
Rated
current
Coil
resistance
Minimum operate
voltage
Release
voltage
Max. voltage Power
consumption
4 poles 24 VDC 15 mA 1,600 75% max. (V) 10% min. (V) 110% (V) Approx. 360 mW
6 poles 20.8 mA 1,152
(
)
(
)
(
)
Approx. 500 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of ±15%.
2. Performance characteristics are based on a coil temperature of 23°C.
3. The voltage is based on an ambient operating temperature of 23°C maximum.
Switching Section (Contact Ratings)
Load type Resistive load (cos θ=1)
Rated load 250 VAC: 6 A, 30 VDC: 6 A
Rated carry current 6A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 6A
JCHARACTERISTICS
Contact resistance 100 mmax. (Measurement conditions: 5 VDC, 1 A, voltage drops)
Operating time (Rated voltage operation, does
t
i
l
d
b
t
i
)
20 ms max.
Release time
(
g
p
,
not include bounce time) 20 ms max.
Response time
(SeeNote2.)
10 ms max.
Maximum operating frequency Mechanical 36,000 operations/hr
p
g
q
y
Rated load 1,800 operations/hr
Insulation resistance
(SeeNote3,4.)
100 M
Dielectric strength Between coil contacts/different poles: 4,000 VAC, 50/60 Hz for 1 min.
Between poles 3-4 (4 poles)
Between contacts of same polarity: 1,500 VAC, 50/60 Hz for 1 min.
Vibration 10 to 55 Hz, 1.5-mm double amplitude
Shock Destruction 1,000 m/s2(approx. 100G)
Malfunction 100 m/s2(approx. 10G)
Life expectancy Mechanical 10,000,000 operations min. (at approx. 36,000 operations/hr)
p
y
Electrical 100,000 operations min. (at the rated load and approx. 1,800 operations/hr)
Ambient temperature
(
S
N
t
5
)
Operating -- 4 0 °Cto85°C(-40°F to 185°F) no icing
p
(SeeNote5.) Storage -- 4 0 °Cto85°C(-40°F to 185°F) no icing
Ambient humidity Operating 35% to 85%
y
Storage 35% to 85%
Weight 4 poles: Approx. 22 g
6 poles: Approx. 25 g
Note: 1. The values listed above are initial values.
2. The response time is the time it takes for the NO contacts to open after the coil voltage is turned OFF.
3. Pole 3: poles 31-32 or 33-34, pole 4: poles 43-44, pole 5: poles 53-54, pole 6: poles 63-64.
4. When using a P7SA socket, the dielectric strength between coil contacts/different poles is 2,500 VAC, 50/60 Hz for 1 min.
5. When operating at a temperature between 70°C and 85°C, reduce the rated carry current (6 A at 70°C or less) by 0.1 A for
each degree above 70°C.
JCHARACTERISTICS OF SAFETY RELAY SOCKET
Model Continuous current Dielectric strength Insulation resistance
P7SA-14j6A 2,500 VAC for 1 min. between poles 100 Mmin. (See Note.)
Note: Measurement conditions: Measurement of the same points as for the dielectric strength at 500 VDC.
G7SA
4
JAPPROVED STANDARDS
EN61810-1 (IEC61810-1)
EN502105
UL508
CSA22.2 No. 14
Dimensions
Unit: mm (inch)
JSAFETY RELAYS
G7S
A
-3
A
1B
G7SA-2A2B
Terminal Installation/
Internal Connection Diagram
(Bottom View)
G7SA-3A1B
G7SA-2A2B
Mounting Holes
(Bottom View)
G7SA-5A1B
G7SA-4A2B
G7SA-3A3B
Terminal Installation/
Internal Connection Diagram
(Bottom View)
G7SA-5A1B
G7SA-4A2B
Mounting Holes
(Bottom View)
G7SA-3A3B
40 max. (1.57)
0.5
0.5
3.5
13 max.
(0.51)
24 max.
(0.94)
1
Ten,
1.4 dia.
50 max. (1.97)
0.5
0.5
3.5
13 max.
(0.51)
24 max.
(0.94)
1
Fourteen,
1.4 dia.
G7SA
5
JSAFETY RELAY SOCKETS
P7S
-10F, P7S
-10F-ND
DIN Rail-mounting Socket or Panel Mounting Terminal Installation/Internal Connection Diagram (Top View)
G7SA-3A1B
Mounted
G7SA-2A2B
Mounted
Mounting Holes (Top View)
Two, 4 dia.
or M3.5
(0.16)
4dia.
(0.16)
22.5 max.
(0.89) 60.5 max. (2.38)
9max.
72 max.
(2.83)
LED
indicator
9max.
P7SA-14F, P7SA-14F-ND
DIN Rail-Mounting Socket or Panel Mounting Terminal Installation/Internal Connection Diagram (Top View)
Mounting Holes (Top View)
G7SA-5A1B
Mounted
G7SA-4A2B
Mounted
G7SA-3A3B
Mounted
4dia.
(0.16)
30 max.
(1.18)
60.5 max. (2.38)
9max.
72 max.
(2.83)
LED
indicator
9max.
Two, 4 dia. or M3.5
(0.16)
Note: Without the finger cover.
Note: Without the finger cover.
Ten, M3
Fourteen,
M3
14.5±0.2
(0.57)
80±0.2
(3.15)
22±0.2
(0.87)
80±0.2
(3.15)
G7SA
6
P7SA-10P Panel-mounting Socket (PCB Terminals)
Terminal Installation/Internal
Connection Diagram
(Bottom View)
Mounting Holes
(Bottom View)
G7SA-3A1B
G7SA-2A2B
Three,
3.2 dia.
(0.13)
Three, 2.6 dia.
(0.10)
50 max.
(1.97)
41.5 max.
(1.63)
Ten, 1.1 dia.
15 max. (0.59)
10.16±0.1
P7SA-14P Panel-mounting Socket (PCB Terminals)
Terminal Installation/Internal
Connection Diagram
(Bottom View)
Mounting Holes
(Bottom View)
G7SA-5A1B
G7SA-4A2B
Three, 2.6 dia.
(0.10)
G7SA-3A3B
Three,
3.2 dia.
(0.13)
60 max.
(2.36)
41.5 max.
(1.63)
15 max. (0.59)
G7SA
7
Precautions
JWIRING
Use one of the following wires to connect to the
P7SA-10F/10F-ND/14F/14F-ND.
Stranded wire: 0.75 to 1.5 mm216 to 18 AWG
Solidwire: 1.0to1.5mm
216 to 18 AWG
Tighten each screw of the P7SA-10F/10F-ND/14F/14F-ND to
atorqueof0.98NSm(10kgfScm) securely.
Insure correct coil polarity, or the G7SA will not operate.
JCLEANING
The G7SA is not of enclosed construction. For this reason, do not
wash the G7SA with water or detergent.
JFORCIBLY GUIDED CONTACTS
(FROM EN50205)
If NO contacts become welded, all NC contacts will maintain a
minimum distance of 0.5 mm when the coil is not energized.
Similarly, if NC contacts become welded, all NO contacts will
maintain a minimum distance of 0.5 mm when the coil is
energized.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.ca
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4
Cat. No. GC SAFETY-2 Printed in USA
OMRON CANADA, INC.
885 Milner Avenue
Toronto, Ontario M1B 5V8
416-286-6465
OMRON ELECTRONICS LLC
One Commerce Drive
Schaumburg, IL 60173
847-843-7900
For US technical support or other inquiries:
800-556-6766
2/03 Specifications subject to change without notice