Agilent Technologies
InfiniiVision 7000B Series Oscilloscopes
Data Sheet
Engineered for the best signal visibility
Oscilloscopes are visual tools and larger, high-resolution displays have become
increasingly important as general purpose scopes need more space to display
digital and serial signals in addition to traditional scope channels.
Wonder why? Agilent engineers developed the InfiniiVision 7000B Series with advanced
technology that will allow you to see more subtle signal detail and more infrequent events
than any other scope on the market. See the InfiniiVision 7000B Series oscilloscope.
Choose from fourteen InfiniiVision 7000B Series models. Agilent provides an easy 5-minute DSO-to-MSO upgrade kit for previously
purchased 7000 Series DSOs.
If you haven’t purchased an Agilent scope lately,
why should you consider one now?
There is no better way to experience
the superiority of the InfiniiVision 7000B
Series scopes than to see it.
Contact Agilent today to request an
evaluation.
Or visit:
www.agilent.com/find/7000B
2
The InfiniiVision 7000B Series offers bandwidths up to 1 GHz. Each model, equipped with a large 12.1” XGA LCD display, comes
in a whisper-quiet package that is just 6.5” deep and weighs only 13 pounds.
Model
Bandwidthh
Sample rate
Memory
Scope
channels
Digital
channels
Update rate
DSO7012B
100 MHz 2 GSa/s 8 Mpts
2
Up to 100,000 deep-memory
waveforms per second, even with
deep memory, digital channels
and serial decode turned on.
DSO7014B 4
MSO7012B 2
16
MSO7014B 4
DSO7032B
350 MHz 2 GSa/s 8 Mpts
2
DSO7034B 4
MSO7032B 2
16
MSO7034B 4
DSO7052B
500 MHz 4 GSa/s 8 Mpts
2
DSO7054B 4
MSO7052B 2 16
MSO7054B 4
DSO7104B
1 GHz 4 GSa/s 8 Mpts 4
MSO7104B 16
1. Biggest display
Oscilloscopes are visual tools and larger, high-resolution screens make the
product better.
Bigger displays have become increasingly important as general
purpose scopes need more space to display digital waveforms and serial decode
traces in addition to traditional analog waveforms.
The 12.1-inch display size helps you easily view up to 20 channels simultaneously
with serial protocol.
2. Fastest architecture
See a display more representative of the actual signals under test. The InfiniiVision
7000B Series shows jitter, infrequent events, and subtle signal detail that other scopes
miss. Turn knobs and the instrument responds instantly and effortlessly. Need to also
view digital channels? The instrument stays responsive. Decoding serial packets? Of-
fering the industry’s only hardware-accelerated serial bus decode, Agilent’s InfiniiVision
series delivers serial debug without compromising analog measurements.
3. Insightful applications
Customize your general purpose scope. A wide range of application packages provide meaningful insight into your application-specific
problems. (See pages 8-9 and 13-14 for more detail.)
InfiniiVision scopes incorporate acquisition memory, waveform processing, and display memory in an advanced 0.13 µ
ASIC. This patented 3rd generation technology, known as MegaZoom III, delivers up to 100,000 waveforms (acquisitions)
per second with responsive deep memory always available.
What gives the InfiniiVision 7000B Series the best signal visibility?
3
Serial with hardware-accelerated decode
• I2C, SPI • Core-assisted FPGA debug • Secure environment
• CAN/LIN • Segmented memory • MIL-STD-1553
• RS-232/UART • Vector signal analysis • FlexRay
• I2S • DSO/MSO offline analysis
• Mask testing • Power measurement
Your design has analog, digital and serial signals ... shouldn’t your scope?
The InfiniiVision 7000B Series scope channels provide faster identification of your most
elusive problems –
Revolutionary high-resolution display.
Engineered with an XGA display and 256 levels of intensity grading, see a precise representation
of the analog characteristics of the signals you’re testing. Equipped with the industry’s fastest
uncompromised update rate at 100,000 waveforms/sec update rate, you’ll capture critical signal
detail and see infrequent events that traditional scopes miss.
MegaZoom III technology.
MegaZoom III responsive deep memory captures long, non-repeating signals and maintains high
sample rates, allowing you to quickly zoom in on areas of interest. Sample rate and memory
depth go hand-in-hand. Deep memory in oscilloscopes sustains a high sample rate over longer
time spans.
Capture a mix of analog or digital signals. Compare multiple cycles of digital signals with
slower analog signals –
16 high-speed timing channels with up to 2 GSa/s deep memory.
Use the timing channels to evaluate control signal relationship. Or capture and view data
buses up to 16 bits wide. Trigger on and display individual signals or bus waveforms in hex
or binary.
Mixed signal trigger.
Trigger across any combination of analog and digital signals simultaneously. See precise ana-
log measurements timed with exact digital content, all in one instrument.
Applications for digital channels. Designing with Altera or Xilinx FPGAs? Use the FPGA dy-
namic probe for rapid internal FPGA measurements. Using I2C, SPI, or RS-232? Use the analog
or digital signals from a 4-channel model to acquire and decode these serial buses.
Capture long streams of serial data and gain fast insight into your problems. Agilent
7000B Series oscilloscopes provide the best serial protocol capabilities in their class –
Serial bus triggering and decoding. Display responsive, on-screen decode of serial bus traffic.
Isolate specific events with pinpoint accuracy. Show decode to validate serial bus activity in
real time.
Quickly find infrequent errors.
Hardware-accelerated decoding increases the scope’s probability of capturing communication
errors. Agilent oscilloscopes can help you catch that intermittent problem before it becomes
an intermittent customer complaint or quality concern.
Easily capture enough serial data to see all of the details.
Use deep memory to capture serial data stream over a long period of time.
Listing Display Window
Shows two views of the serial decoded data, a serial decode trace that is time-correlated to
the waveform and “list” view of each field and packet.
Analog: Up to 1 GHz bandwidth and up to
4 GSa/s sample rate
Digital: 16 digital timing channels with
mixed signal triggering
4
Serial Search and Navigate
Search through deep memory acquisitions of serial data faster than was ever possible
before.
Save Debug with automatic Search and Navigate capability. Navigate through the serial data
holding direct time-alignment to captured waveforms by simply turning the selection knob to
easily correlate the decoded packet to the waveform.
Serial: Hardware-accelerated decode and
trigger for 12C, I2S, SPI, RS-232, CAN, LIN,
FlexRay, and Mil-STD 1553
Other useful features
High resolution mode. Offers up to 12 bits of
vertical resolution. This is accomplished by
serially filtering sequential data points and
mapping the filtered results to the display
when operating at time base settings greater
than 10-μs/div.
Help is at your fingertips. An embedded help
system – available in 11 languages – gives
you quick answers if you don’t understand
a feature. Simply press and hold the corre-
sponding front-panel key, and a screen pops
up to explain its function.
Waveform math with FFT. Analysis functions
include subtract, multiply, integrate, square
root, and differentiate, as well as fast Fourier
transforms (FFT).
Peak detect. 250 ps on 500-MHz and 1-GHz
models, 500 ps on 350-MHz models. Helps
you find narrow glitches.
AutoProbe interface. Automatically sets
probe attenuation factors and provides power
for selected active probes, including the
award-winning 1130A 1.5-GHz InfiniiMax
differential active probe and 1156A 1.5-GHz
single-ended active probe systems.
5-digit hardware counter. Measures fre-
quency up to the bandwidth of the scope and
provides accurate and repeatable results. Can
be increased to 8 digits with an external 10
MHz reference.
Trig Out and Reference Clock In/Out. Pro-
vides an easy way to synchronize your scope
to other instruments. Use the Trig Out port to
connect your scope to a frequency counter
for more accurate frequency measurements
or to cross trigger other instruments.
Autoscale. Displays all analog and digital
active signals, and automatically sets the
vertical, horizontal and trigger controls.
23 automatic measurements with statistics.
Get up to 4 simultaneous measurements with
5 additional statistics beyond the current
value. Fast update rate provides statisti-
cal data for enabled measurements such
as mean, min, max, standard deviation and
count. Pressing [QuickMeas] brings up the
last four automated measurements selected.
Cursors automatically track the most recently
selected measurement.
Analog HDTV/EDTV trigger. The 7000B
Series comes standard with analog HDTV/
EDTV triggering for standards like 1080i,
1080p, 720p and 480p as well as standard
video triggering on any line within a field,
all lines, all fields and odd or even fields for
NTSC, SECAM, PAL and PAL-M video signals.
Bus mode display (on MSO models). Quick
and easy read-out of hexadecimal or binary
representation of logic signals.
Easy software upgrades. System software
is stored in flash ROM that can be upgraded
from the scope’s built-in USB port or LAN.
You can find the latest system and IntuiLink
software at:
www.agilent.com/find/7000Bsw
Press and hold a key for instant help.
Measurement statistics allow you to
have confidence in your measurements.
Statistics can show that a measure-
ment is not only correct at one moment,
but that it has stabilized and has a low
variance over time, giving it a higher
statistical validity.
Digital signals can be displayed
individually or as overlayed bus values.
5
Dedicated Front Panel Key
Simply press the dedicated front panel Search
Key and enter a variety of specific search criteria
Navigate Through the Captured Waveform
Automatically marks each frame in the selected search criteria. Use the dedicated front
panel navigation keys to automatically jump to the next or previous marked frame or play
through the entire waveform with control to stop, rewind or adjust the speed of waveform
scrolling.
Why does a fast update rate matter?
While bandwidth, sample rate and memory depth are key criteria for
deciding which scope to purchase, an equally important characteristic
is update rate.
What is update rate?
Update rate is how many waveforms acquisitions per seconds your
scope can acquire, process, and display. Oscilloscope “dead-time” is
the time it takes for a scope to process and then display an acquired
waveform before re-arming it’s triggering for the next acquisition. For
traditional scopes, this time is often orders of magnitude greater than
acquisition time on fast time-per-division settings.
If a glitch occurs during the scope’s dead-time, it won’t be captured.
The key to improving the probability of capturing a signal anomaly
during the scope acquisition time is to minimize dead-time.
Oscilloscope vendors usually specify what their scope’s “best-case”
waveform update rates are. Some scope architectures suffer from
factors that can seriously degrade the “best-case” update rates spec.
Agilent’s 7000B Series architecture delivers the fastest update rate
when using:
Analog channels
Analog and digital
Deep memory
Serial decode
Why is update rate important?
1. Certainty. Fast waveform update rates improve the scope’s prob-
ability of capturing random and infrequent events.
2. Responsiveness. If you rotate the timebase control, you expect
the oscilloscope to respond immediately – not seconds later after
the scope finishes processing data.
3. Signal detail. Fast waveform update rates improve the display
quality of the waveform that you see on screen.
Update rates directly affect a scope probability of capturing and dis-
playing infrequent and random events. Slow update rates will cause a
scope to miss subtle or infrequent signal details.
Improves instrument responsiveness
Improves scope display quality
Improves probability of capturing
infrequent events
6
How update rate affects signal visibility
Capturing random and infrequent events on an oscilloscope is all about statistical probabilities. The key to improving the probability of
capturing a signal anomaly is to minimize dead-time and take more pictures of the signal in a given timeframe. Here is an example with Tek
and Agilent scopes both connected to a target with a glitch that occurs 25 times per second.
Seeing subtle signal detail and infrequent events requires a scope with fast waveform update rates. Don’t take a scope vendor’s banner waveform
update rate specification at face value. Test it yourself. It’s actually pretty easy to characterize a scope’s update rate. Run a moderately fast signal (e.g.
50 Mhz) into a scope channel. Measure the scope’s average trigger output signal frequency. This is your scope’s update rate for the specified time-
base setting. Test the update rate of the scope under various setup conditions. Setup conditions that Agilent suggests varying include timebase range,
memory depth, and number of channels, including analog, digital, as well as channels assigned for serial decoding.
Tek MSO4104
Product data sheet: 50,000 waveforms per second,
Update rate = 18 waveforms per second with 10 Mpts and
digital channels turned on. Resulting measurement shown.
Probability of capturing the infrequent glitch = 0.09% after
running for 10 seconds.
Average time to capture just one glitch = 128 minutes.
Agilent MSO7104B
Product data sheet: 100,000 waveforms per second.
Update rate = 95,000 waveforms per second with auto
memory and digital channels turned on. Resulting
measurement shown.
Probability of capturing the infrequent glitch = 99% after
running for 10 seconds.
Average time to capture just one glitch = 1.5 seconds.
7
Memory* Scope settings Measured update rates
Infrequent
signal activity
Critical
signal jitter
?
??
* Agilent and LeCroy memory depth selection was automatically selected. Memory depth = display window times sample rate with up to 8 Mpts for Agilent.
** Tek measurements taken with version 2.13 firmware.
Initial setup
Change timebase
Add digital channels
Increase memory setting
Turn on serial decode
Timebase setting
20 ns/div
10 ns/div
20 ns/div
20 ns/div
20 ns/div
TEK MSO4104A**
55,000
2,700
125
35
0.2
Digital Channels
-
-
On
On
On
LeCroy WR 104Xi
27
27
27
27
25
Serial Decode
-
-
-
-
On
Agilent MSO7104B
95,000
60,000
95,000
95,000
95,000
Tek
10 Kpts
10 Kpts
10 Kpts
10 Mpts
10 Mpts
Software applications
I2C/SPI serial trigger and decode (N5423A or Option LSS on new scope purchases)
This application displays real-time time-aligned decode of I2C and SPI serial buses. Hardware-
accelerated decode means the scope stays responsive and fast.
This application requires a 4-channel DSO or 4-channel MSO and can use any combination of
the scope or logic acquisition channels.
For more information: www.agilent.com/find/I
2
C-SPI
RS-232/UART serial decode and trigger (N5457A or Option 232 on new scope purchases)
Does your design include RS-232 or another type of UART? This application eliminates the need
to manually decode bus traffic. Using data captured on the scope or logic channels, the appli-
cation lets you easily view the information sent over a RS-232 or other UART serial bus.
Display real-time time-aligned decode of transmit and receive lines. The application also en-
ables triggering on RS-232/UART conditions.
This application requires a 4-channel DSO or 4-channel MSO and can use any combination of
the scope or logic acquisition channels.
For more information: www.agilent.com/find/RS-232
View on-screen serial decode of an I2C packet.
Trigger on and decode RS-232/UART
transmission.
8
Segmented memory (N5454A or Option SGM on new scope purchases)
Segmented memory optimizes available memory for data streams that have long dead times be-
tween activity. The application excels at analyzing signal activity associated with laser pulses,
serial buses, and bursty signals such as radar.
View an overlay of all signal segments, including MSO channels and serial decode, while high-
lighting the current segment. Quickly move between segments to view signal detail associated
with a specific segment.
For more information: www.agilent.com/find/segmented
Use segmented memory to optimize
available memory.
Mask testing (N5455A or Option LMT)
Agilent’s mask test option (Option LMT or N5455A) for InfiniiVision Series oscilloscopes pro-
vides a fast and easy way to test your signals to specified standards, and uncover unexpected
signal anomalies, such as glitches. Mask testing on other oscilloscopes is based on software-
intensive processing technology, which tends to be slow.
Agilent’s InfiniiVision scopes can perform up to 100,000 real-time waveform pass/fail tests per
second. This provides testing throughput significantly faster than other mask test solutions,
making valid pass/fail statistics available almost instantly.
For more information: www.agilent.com/find/masktest
Mask testing uncovers an infrequent
signal anomaly.
CAN/LIN triggering and decode (N5424A or Option AMS on new scope purchases)
Trigger on and decode serially transmitted data based on CAN and LIN protocols. This ap-
plication not only provides triggering on complex serial signals, but it also provides unique
hardware-accelerated capabilities. Hardware-accelerated triggering and decode means the
scope stays responsive and fast.
This application requires a 4-channel DSO or 4-channel MSO and can use any combination of
scope or logic acquisition channels.
For more information: www.agilent.com/find/CAN-LIN.
Trigger on and decode CAN serial packets.
Software applications
FPGA dynamic probe application (N5406A for Xilinx, N5434A for Altera)
Give your MSO internal FPGA visibility. Agilent’s MSO FPGA dynamic probe provides internal
FPGA visibility and quick instrument setup using an innovative core-assisted debug approach.
Measurement tasks that previously took hours can be done in a few mouse clicks. In a few
seconds, easily measure a different set of internal signals without changing your FPGA design.
For more information:
www.agilent.com/find/7000-altera
www.agilent.com/find/7000-xilinx
Debug and validate your FPGA designs
faster and more effectively
9
On-screen serial decode of an SPI packet
FlexRay Measurements (N5432C or Option FLX on new scope purchases)
Trigger on and time-correlate FlexRay communication with physical layer signals. With
Agilent’s unique hardware-accelerated decoding, it provides the fastest decode update
rates in the industry while the scope remains responsive and fast. Also included with this
option is FlexRay eye-diagram mask testing and physical layer conformance test solution.
This application requires a 4-channel DSO or 4-channel MSO and can use any combina-
tion of scope or logic acquisition channels.
For more information: www.agilent/find/flexray
Time-correlated display of the FlexRay
physical layer signal with protocol
decoding.
I2S triggering and decode (Option SND or N5468A)
Find and debug intermittent errors and signal integrity problems faster on I2S audio protocol
devices. This application offers powerful triggering and our unique hardware-accelerated
decode and lister window so you can more easily find errors you could miss using other
serial bus decode tools.
This application requires a 4-channel DSO or 4-channel MSO and can use any
combination of scope or logic acquisition channels.
For more information: www.agilent.com/find/I2S
Time-correlated display of the MIL-STD 1553
physical layer signal with protocol decoding.
MIL-STD 1553 Serial Trigger and Decode (N5469A or Option 553 on new scope purchase)
This application provides integrated MIL-STD 1553 serial bus triggering, hardware-based
decoding, and eye-diagram mask testing to help you debug and characterize the
electrical/physical layer of MIL-STD 1553 serial buses faster than with traditional
“bit-counting” methods.
This application requires a 4-channel DSO or 4-channel MSO and can use any combina-
tion of scope of logic acquisition channels
For more information: www.agilent.com/find/1553
Evaluation kit (N2918A)
The evaluation kit includes a variety of signals that demonstrate MegaZoom III technology
with its fast deep memory, superior waveform update rate, high definition display and mixed
analog, digital and serial abilities.
Using this scope evaluation kit along with the easy-to-follow user’s guide, you can quickly
become familiar with how to effectively operate an InfiniiVision 7000B Series scopes.
The evaluation kit helps you discover
the power of InfiniiVision 7000B Series
oscilloscopes.
Secure environment mode (Option SEC)
Option SEC – secure environment mode provides the highest level of security by ensuring
internal nonvolatile memory is clear of all setup and trace settings in compliance with National
Industrial Security Program Operation Manual (NISPOM) Chapter 8 requirements. When this
option is installed, it will store setup and trace settings to internal volatile memory only.
Volatile memory will be cleared during the power off cycle of the instrument. So you can move
the instrument out of a secure area with confidence.
For more information: Option SEC Secure
Environment Mode Option for Agilent 7000B Series Oscilloscopes Data Sheet
Secure environment mode ensures
nonvolatile memory is cleared on
power off.
Software applications and other accessories
10
Offline viewing and analysis (B4610A)
Need to view and analyze scope data away from your scope? Need to share measurement
data with geographically dispersed team members? Save your scope data to a USB or
network drive and import the data into a PC-based offline viewer. Pan and zoom.
Use searching and filtering to gain insight on analog and digital buses. Email the data to team
members who can use the same tool at their PCs.
For more information: www.agilent.com/find/InfiniiVisionOffline
View and analyze previously
acquired scope data on a PC-based
offline tool.
Vector signal analysis software (89601A)
Expand the measurement capability of your scope with the 89601A vector signal analysis
software. This advanced DSP-based software takes the digitized signal data provided by the
scope and provides FFT-based spectrum analysis and wide bandwidth digital modulation
analysis for wireless communication signals like WCDMA and cdma2000, and wireless
networking signals like 802.11 WiFi and 802.16 WiMaxTM.
Take advantage of the super wide bandwidth of your scope to capture and evaluate radar
signals.
For more information: www.agilent.com/find/7000-vsa
Expand the capability of your
scope with 89601A vector analysis
software.
Power application (U1881A)
Need to make power measurements with your scope? Agilent’s power application provides a
full suite of power measurements that run on a PC connected to an InfiniiVision 7000B Series
oscilloscope. Make more accurate power supply efficiency measurements by using an U1880A
deskew fixture to deskew your voltage and current probes.
For more information: www.agilent.com/find/power-app
Use your scope to quickly make and
analyze power measurements.
Probes and accessories
Agilent offers a complete family of innovative passive and active probes for the InfiniiVision 7000B
Series scopes helps you get your job done easily and accurately. Choosing the correct probe for your
application will help to ensure you accurately acquire signals. Below is a general guide on how to
choose the type of probe. For the most up-to-date information about Agilent’s accessories, please
visit our Web site at www.agilent.com/find/scope_probes.
Probe type Key characteristics
Passive probes: most common type of probe, rugged and economical with bandwidth generally lower than 500 MHz
10070C
10073D
10074D
N2871A
N2873A
1:1 20 MHz with probe ID
10:1 500 MHz with probe ID (standard with 350 MHz - 1 GHz models)
10:1 150 MHz with probe ID (standard with 100 MHz models)
10:1 150 MHz passive probe with probe ID (optional with 100 MHz models)
10:1 500 MHz with probe ID (optional with 350 MHz - 1 GHz models)
High voltage passive probe: view up to 30 kVDC + peak AC voltage referenced to earth ground
10076B
N2771A
100:1, 4 kV, 250 MHz probe with ID
1000:1, 30 kV, 50 MHz probe
Single-ended active probes: contains small, active amplifier and enables the probe input capacitance to be very low resulting in high input
impedance on high frequencies. Least intrusive of all probes.
N2795A
N2596A
1156A
1144A
1145A
1 GHz with AutoProbe interface, head light and 1MΩ input Z
2 GHz with AutoProbe interface, head light and 1MΩ input Z
1.5 GHz with AutoProbe interface
800 MHz (requires 1142A – power supply)
750 MHz 2-ch (requires 1142A – power supply)
Active differential probes: use to look at signals that are referenced to each others instead of earth ground and to look at small signals in the
presence of large DC offsets or other common mode signals such as power line noise.
1130A
N2790A
N2791A
N2792A
N2793A
N2891A
1.5 GHz InfiniiMax amplifier with AutoProbe interface (requires one or more
InfiniiMax probe head – E2675A, E2668A, E2669A)
100 MHz, 1.4 kV high-voltage differential probe with AutoProbe interface
25 MHz, 700 V high-voltage differential probe (battery or USB powered)
200 MHz, +/-20 V differential probe (battery or USB powered)
800 MHz, +/-15 V differential probe (battery or USB powered)
70 MHz, +/-7 kV differential probe (battery or USB powered)
Current probes: sense the AC or DC current flowing through a conductor and convert it to a voltage that can be viewed and measured on an
oscilloscope. Compatible with 1 MΩ scope input.
1146A
1147B
N2893A
N2780A
N2781A
N2782A
N2783A
100 kHz, 100 A, AC/DC
50 MHz, 15 A, AC/DC with AutoProbe interface
100 MHz, 15 A, AC/DC with AutoProbe interface
2 MHz, 500 A, AC/DC (use with N2779A power supply)
10 MHz, 150 A, AC/DC (use with N2779A power supply)
50 MHz, 30 A, AC/DC (use with N2779A power supply)
100 MHz, 30 A, AC/DC (use with N2779A power supply)
MSO probes: offer the best performance and access to the industry’s broad range of logic analyzer probing accessories
01650-61607
54620-68701
With this 40-pin logic cable, Agilent MSOs accept numerous logic
analyzer accessories such as Mictor, Samtec, flying leads or soft touch
connectorless probes.
Included with all MSO models is a logic probe with 2x8 flying
leads (includes 20 IC clips and five ground leads)
For more comprehensive information, refer to the Agilent 5000, 6000 and 7000 Series Oscilloscopes Probes and Accessories Data Sheet
(with Agilent lit number 5968-8153EN).
11
The 7000 B Series scopes come with the most comprehensive connectivity tools in
their class.
LXI class C
LAN eXtensions for Instrumentation (LXI) is a standards-based architecture for test systems.
By specifying the interaction of system components, LXI enables fast and efficient test system
creation and reconfiguration. The 7000 B Series oscilloscopes follow specified LAN protocols
and adhere to LXI requirements such as a built-in Web control server, IVI-COM driver, and easy-
to-use SCPI commands. The standard Agilent I/O Library Suite makes it easy to configure and
integrate instruments in your system.
IntuiLink toolbars and IntuiLink Data Capture
IntuiLink gives you a quick way to move oscilloscope screen shots and data into Microsoft®
Word and Excel. These toolbars can be installed from www.agilent.com/find/intuilink.
View Scope logic analyzer and oscilloscope correlation
View Scope enables simple and free time-correlated measurements between a 7000B Series
oscilloscope and an Agilent 16900, 16800, 1690, or 1680 Series logic analyzer. Scope and logic
waveforms are integrated into a single logic analyzer waveform display for easy viewing analysis
– all with a simple point-to-point LAN connection. You can also cross-trigger the instruments,
automatically de-skew the waveforms, and maintain marker tracking between the instruments.
National Instrument drivers
InfiniiVision 7000B Series oscilloscopes are supported by LabVIEW plug-and-play and
IVI-C drivers.
Connectivity
Agilent Remote Front Panel running in a
Web browser
Use IntuiLink to import scope screen shots
and data into Microsoft Word and Excel.
Use ViewScope to time-correlate
oscilloscope and logic analyzer
measurements.
12
Agilent’s InfiniiVision lineup includes 2000X, 3000X, 6000, and 7000B Series oscilloscopes. These share a number of advanced hard-
ware and software technology blocks. Use the following selection guide to determine which scope best matches your specific needs.
Agilent InfiniiVision Portfolio
13
Ideal for ATE rackmount
applications
Largest display,
shallow depth
4 instruments in 1 for
the same price
Only economy scope
with mixed signal
capability
Bandwidth 6000L Series 7000B Series 3000 X-Series 2000 X-Series
70 MHz Bandwidth
100 MHz Bandwidth
200 MHz Bandwidth
350 MHz Bandwidth
500 MHz Bandwidth
1 GHz Bandwidth
MSO Models
GPIB Connectivity
Rackmount height 1U 7U 5U 5U
Display size 12.1” 8.5” 8.5”
Footprint (WxHxD) 15.2”x 7.4”x 6.9” 17.9”x 10.9”x 6.8” 14.9”x 8.1”x 5.6” 14.9”x 8.1”x 5.6”
Agilent’s InfiniiVision oscilloscope portfolio offers:
A variety of form factors to fit your environment
Responsive controls and best signal visibility
Insightful application-specific measurement options
Responsive deep memory with MegaZoom technology
Agilent InfiniiVision 7000B Series oscilloscopes:
Engineered for the best signal visibility
12.1” large display makes it easier to view analog,
digital and serial signals.
High-resolution color display with XGA resolution
and 256 levels of intensity reveals subtle details
that most scopes won’t show you.
Built-in USB port makes it easy
to save your work and update your
system software quickly.
Free IntuiLink data capture PC software makes
transferring waveform data or a screen image to a
PC fast and easy. Built-in Web viewer via LAN allows
for remote measurements and viewing.
Built-in help in eleven
languages – Simply press
and hold the front-panel
key of interest for a few
seconds and a help screen
pops up to explain its
function.
An XGA video output port allows you
to connect to a large external monitor.
Standard USB and LAN ports provide
PC and printer connectivity. For GPIB
connectivity, order N4865A adapter.
Trig Out port provides an easy way
to synchronize your scope to other
instruments.
Built-in 10-MHz reference in/out port synchronizes
multiple measurement instruments in a system.
14
GUI and front panel
overlays available in
multiple languages-
GUI menus and remov-
able key/knob overlays
for the front panel are
available in several
languages.
Trig In port provides an
easy way to what ever
AutoProbe interface automatically configures the attenuation
ratio of the probe and provides probe power for Agilent’s active
probes.
InfiniiVision 7000B Series 2-channel model
Dedicated front panel controls make it easy to access the
most common scope controls, including vertical and horizontal
scaling.
15
Quickly pan and zoom for analysis with MegaZoom III’s
instant response and optimum resolution.
Standard serial triggering includes I2C, SPI, and USB (op-
tional CAN/LIN, RS-232/UART, FlexRay, I2S, and
MIL-STD1553 advanced triggering and decode).
Standard analog HDTV/EDTV triggering supports triggering
on 1080i, 1080p, 720p, and 480p HDTV/EDTV standards.
Digital channel keys provide quick set-up access.
Intensity knob allows you to see the right level of waveform
detail, just like an analog scope.
QuickMeas shows up to four automated measurements with
the push of a button.
Autoscale lets you quickly display any analog or digital active
signals, automatically setting the vertical, horizontal and
trigger controls for the best display, while optimizing memory.
Search and Navigate front panel controls make it easy to
find a view specific signal activity.
SAVE screen images and waveform data to a connected USB
storage device.
Performance characteristics
Acquisition: scope channels
Sample rate MSO/DSO701xB: 2 GSa/s each channel
MSO/DSO703xB: 2 GSa/sec each channel
MSO/DSO705xB, 710xB: 4 GSa/sec half channel*, 2 GSa/sec each channel
Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off)
Maximum memory depth 2 channels/4 channels
Standard 8 Mpts/4 Mpts
Vertical resolution 8 bits
Peak detection MSO/DSO701xB: 500-ps peak detect
MSO/DSO703xB: 500-ps peak detect
MSO/DSO705xB/710xB: 250-ps peak detect
Averaging Selectable from 2, 4, 8, 16, 32, 64 … to 65536
High resolution mode up to 12 bits of resolution when ≥10 µs/div at 4 GSa/s or ≥20-µs/div at 2 GSa/s
Filter Sin (x)/x interpolation (single shot BW = sample rate/4 or bandwidth of scope,
whichever is less) with vectors on and in real-time mode
Acquisition: digital channels (7000B Series MSO or MSO-upgraded 7000B Series DSO)
Sample rate 2 GSa/sec one pod**, 1 GSa/sec each pod
Maximum input frequency 250 MHz
Maximum memory depth One pod/both pods (with scope channels turned off)
Standard 8 Mpts/4 Mpts
One pod/both pods (with scope channels turned on)
Standard 2.5 Mpts/ 1.25 Mpts
Vertical resolution 1 bit
Glitch detection 2 ns (min pulse width)
* Half channel is when one of channel 1 or 2 is turned on, and/or one of channel 3 or 4 is turned on.
** A pod is a group of eight digital channels, either 0-7 or 8-15.
16
Performance characteristics (continued)
Vertical system: scope channels
Scope channels MSO/DSO7xx2B: Ch 1 and 2 simultaneous acquisition
MSO/DSO7xx4B: Ch 1, 2, 3 and 4 simultaneous acquisition
Bandwidth (–3 dB)* MSO/DSO701xB: DC to 100 MHz
MSO/DSO703xB: DC to 350 MHz
MSO/DSO705xB: DC to 500 MHz
MSO/DSO710xB: DC to 1 GHz
AC coupled MSO/DSO701xB: 3.5 Hz to 100 MHz
MSO/DSO703xB: 3.5 Hz to 350 MHz
MSO/DSO705xB: 3.5 Hz to 500 MHz
MSO/DSO710xB: 3.5 Hz to 1 GHz
Calculated rise time (=0.35/bandwidth) MSO/DSO701xB: 3.5 nsec
MSO/DSO703xB: 1 nsec
MSO/DSO705xB: 700 psec
MSO/DSO710xB: 350 psec
Single-shot bandwidth MSO/DSO701xB: 100 MHz
MSO/DSO703xB: 350 MHz
MSO/DSO705xB: 500 MHz
MSO/DSO710xB: 1 GHz (in half-channel mode)
Range1 MSO/DSO701xB, MSO/DSO703xB and MSO/DSO705xB: 2 mV/div to 5 V/div (1 MΩ or 50 Ω)
MSO/DSO710xB: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω)
Maximum input CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
With 10073C/D 10:1 probe: CAT I 500 Vpk
Offset range ±5 V on ranges <10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div;
±75 V on ranges >200 mV/div
Dynamic range ±8 div
Input impedance 1 MΩ ± 1% || 14 pF or 50 Ω ± 1.5%, selectable
Coupling AC, DC
BW limit 25 MHz selectable
Channel-to-channel isolation DC to max bandwidth >40 dB
Standard probes 10073D or 10074D shipped standard for each scope channel (N2873A or N2871A optional)
Probe ID Auto probe sense and AutoProbe interface
Agilent- and Tektronix-compatible passive probe sense
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
1 2 mV/div is a magnification of 4 mV/div setting for 350 MHz to 1 GHz models. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting
and 32 mV for 2 mV/div sensitivity setting.
17
Performance characteristics (continued)
Vertical system: scope channels (continued)
ESD tolerance ±2 kV
Noise, RMS, input shorted MSO/DSO701xB: 0.50% FS or 300 µV, whichever is greater
MSO/DSO703xB: 0.50% FS or 300 µV, whichever is greater
MSO/DSO705xB: 0.50% FS or 360 µV, whichever is greater
MSO/DSO710xB: 0.65% FS or 360 µV, whichever is greater
DC vertical gain accuracy*1 ±2.0% full scale
DC vertical offset accuracy ≤200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value;
>200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value
Single cursor accuracy1 ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)}
Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset,
accuracy = ±{2.0% (80 mV) + 0.1 (10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2% (80 mV)} =
± 4.785 mV
Dual cursor accuracy*1 ±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)}
Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset,
accuracy = ±{2.0% (80 mV) + 0.4% (80 mV)} = ±1.92 mV
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
1 2 mV/div is a magnification of 4 mV/div setting for 350 MHz to 1 GHz models. For vertical accuracy calculations, use full scale of 16 mV for 1 mV/div sensitivity setting and 32
mV for 2 mV/div sensitivity setting.
Vertical system: digital channels (MSO or MSO-upgraded DSO)
Number of channels 16 logic timing channels – labeled D15 - D0
Threshold groupings Pod 1: D7 - D0
Pod 2: D15 - D8
Threshold selections TTL, CMOS, ECL and user-definable (selectable by pod)
User-defined threshold range ±8.0 V in 10 mV increments
Maximum input voltage ±40 V peak CAT I; transient overvoltage 800 Vpk
Threshold accuracy* ±(100 mV + 3% of threshold setting)
Input dynamic range ±10 V about threshold
Minimum input voltage swing 500 mV peak-to-peak
Input capacitance ~8 pF with flying leads
Input resistance 100 kΩ ±2% at probe tip
Channel-to-channel skew 2 ns typical, 3 ns maximum
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
18
Performance characteristics (continued)
Horizontal
Range MSO/DSO701xB: 2 nsec/div to 50 sec/div
MSO/DSO703xB: 2 nsec/div to 50 sec/div
MSO/DSO705xB: 1 nsec/div to 50 sec/div
MSO/DSO710xB: 500 psec/div to 50 sec/div
Resolution 2.5 ps
Time scale accuracy* ≤ ± (15+2* (instrument age in years)) ppm
Vernier 1-2-5 increments when off, ~25 minor increments between major settings when on
Delay range Pre-trigger (negative delay): Greater of 1 screen width or 1 ms
Post-trigger (positive delay): 1 s to 500 seconds
Analog delta-t accuracy Same channel: ±0.0015% reading ±0.1% screen width ±20 ps
Channel-to-channel: ±0.0015% reading ±0.1% screen width ±40 ps
Same channel example (MSO/DSO705xB):
For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{0.0015% (10 µs) + 0.1% (50 µs) + 20 ps} = 50.17 ns
Logic delta-t accuracy Same channel: ±0.005% reading ±0.1% screen width ±(1 logic sample period, 1 ns)
Channel-to-channel:
±0.005% reading ±0.1% screen width ±(1 logic sample period) ±chan-to-chan skew
Same channel example:
For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{0.005% (10 µs) + 0.1% (50 µs) + 1 ns} = 51.5 ns
Modes Main, zoom, roll, XY, segmented (optional)
XY Bandwidth: Max bandwidth
Phase error at 1 MHz: < 0.5 degrees
Z Blanking: 1.4 V blanks trace (use external trigger on MSO/DSO7xx2B,
channel 4 on MSO/DSO7xx4B)
Reference positions Left, center, right
Segmented memory re-arm time 8 µs (minimum time between trigger events)
Trigger system
Sources MSO7xx2B: Ch 1, 2, line, ext, D15 - D0
DSO7xx2B: Ch 1, 2, line, ext
MSO7xx4B: Ch 1, 2, 3, 4, line, ext, D15 - D0
DSO7xx4B: Ch 1, 2, 3, 4, line, ext
Modes Auto, normal (triggered), single
Holdoff time ~60 ns to 10 seconds
Trigger jitter 15 ps rms
* Denotes warranted specification. Specifications are valid after a 30 minute warm-up period and ±10 °C from firmware calibration procedure.
19
Performance characteristics (continued)
Trigger system (continued)
Selections Edge, pulse width, pattern, TV, duration, sequence, CAN, LIN, USB, I2C, SPI,
Nth edge burst, RS-232 with Option 232
Edge Trigger on a rising, falling, alternating or either edge of any source
Pattern Trigger at the beginning of a pattern of high, low, and don’t care levels and/or a rising or
falling edge established across any of the analog and digital channels, but only after a
pattern has stabilized for a minimum of 2 nsec.
The scope channel’s high or low level is defined by that channel’s trigger level. The logic
channel’s trigger level is defined by the threshold for the pod, 0 - 7 or 8 - 15.
Pulse width Trigger when a positive- or negative-going pulse is less than, greater than, or within a
specified range on any of the source channels.
Minimum pulse width setting: 5 ns (MSO/DSO701xB/703xB scope channels)
2 ns (MSO/DSO705xB/710xB scope channels)
2 ns (logic channels on 7000B Series MSO or
MSO-upgraded 7000B Series DSO)
Maximum pulse width setting: 10 s
TV Trigger using any scope channel on most analog progressive and interlaced video standards
including HDTV/EDTV, NTSC, PAL, PAL-M or SECAM broadcast standards. Select either
positive or negative sync pulse polarity. Modes supported include Field 1, Field 2, all fields,
all lines, or any line within a field. TV trigger sensitivity: 0.5 division of sync signal. Trigger
holdoff time can be adjusted in half field increments.
Sequence
Arm on event A, trigger on event B (edge or pattern), with option to reset on event C or time delay.
CAN Trigger on CAN (controller area network) version 2.0A and 2.0B signals. Trigger on the start
of frame (SOF) bit (standard). N5424A option supports triggering on remote frame ID (RTR),
data frame ID (~RTR), remote or data frame ID, data frame ID and data, error frame, all errors,
acknowledge error and overload frame.
FlexRay Trigger on FlexRay Frames, errors, events and cycle-multiplexed triggering. N5432C or option
FLX supports also triggering on particular frame types symbolically, such as Startup frames,
Null frame, Sync frame, etc., as well as Boolean NOT frame types.
LIN Trigger on LIN (local interconnect network) sync break at beginning of message frame
(standard). N5424A option supports triggering on frame ID.
USB USB Trigger on USB (universal serial bus) start of packet, end of packet, reset complete,
enter suspend, or exit suspend on the differential USB data lines. USB low speed and full
speed are supported.
I2C Trigger on I2C (inter-IC bus) serial protocol at a start/stop condition or user defined frame
with address and/or data values. Also trigger on missing acknowledge, address with no acq,
restart, EEPROM read, and 10-bit write.
SPI Trigger on SPI (serial protocol interface) data pattern during a specific framing period.
Supports positive and negative Chip Select framing as well as clock idle framing and
user-specified number of bits per frame.
I2S This application provides triggering on audio bus protocol channels for audio left, right, either
as well as =, ≠, >,< entered data values and within and out of range values. It provides the
ability to easily view the audio packets on the waveform and in a listing window.
RS-232/UART This application eliminates the need to manually decode bus traffic. Using data captured on
the scope or digital channels, the application provides the ability to easily view the information
sent over a RS-232 serial bus. Display real-time time-aligned decode of transmit and receive
lines. The application also enables triggering on RS-232/UART conditions.
Duration Trigger on a multi-channel pattern whose time duration is less than a value, greater than a
value, greater than a time value with a timeout, or inside or outside of a set of time values.
Minimum duration setting: 2 ns
Maximum duration setting: 10 s
MIL-STD 1553 Trigger on specific Command/Status Words, Data Words, and error conditions.
20
Performance characteristics (continued)
Trigger system (continued)
Nth edge burst Trigger on the Nth edge of a burst that occurs after an idle time that you specify. Max edge
count: 65,536.
Autoscale Finds and displays all active scope and logic (for 7000B Series MSO) channels, sets edge
trigger mode on highest-numbered channel, sets vertical sensitivity on scope channels and
thresholds on logic channels, time base to display ~1.8 periods. Requires minimum voltage
>10 mVpp, 0.5% duty cycle and minimum frequency >50 Hz.
Scope channel triggering
Range (internal) ±6 div from center screen
Sensitivity* <10 mV/div: greater of 1 div or 5 mV; ≥10 mV/div: 0.6 div
Coupling AC, ~10 Hz on MSO/DSO701xB/703xB/705xB/710xB,
DC, noise reject, HF reject and LF reject (~50 kHz)
Digital (D15 - D0) channel triggering (7000B Series MSO or MSO-upgraded 7000B Series DSO)
Threshold range (user defined) ±8.0 V in 10 mV increments
Threshold accuracy ±(100 mV + 3% of threshold setting)
Predefined thresholds TTL = 1.4 V, CMOS = 2.5 V, ECL = –1.3 V
External (EXT) triggering MSO/DSO7xx2B (2-/2+16-ch models) MSO/DSO7xx4B (4-/4+16-ch models)
Input impedance 1 MΩ ± 3% || 14 pF or 50 Ω 2.14 kΩ ±5%
Maximum input CAT I 300 Vrms ±15 V
With 10073C/D 10:1 probe: CAT I 500 Vpk
Range DC coupling: trigger level ±1 V and ±8 V ±5 V
Sensitivity For ±1 V range setting: DC to 500 MHz: 500 mV
DC to 100 MHz, 100 mV;
For ±8 V range setting:
DC to 100 MHz, 250 mV;
>100 MHz to bandwidth of oscilloscope: 500 mV
Coupling AC (~3.5 Hz), DC, noise reject, HF reject and LF reject (~50 kHz)
Probe ID Auto probe sense and AutoProbe interface
Agilent- and Tektronix-compatible passive probe sense
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
21
Performance characteristics (continued)
Display system
Display 12.1-inch (255 mm x 184 mm) diagonal color TFT LCD
Throughput of scope channels Up to 100,000 waveforms/sec in real-time mode
Resolution XGA – 768 vertical by 1024 horizontal points (screen area);
640 vertical by 1000 horizontal points (waveform area)
256 levels of intensity scale
Controls Waveform intensity on front panel. Vectors on/off; infinite persistence on/off,
8 x 10 grid with intensity control
Built-in help system Key-specific help displayed by pressing and holding key or softkey of interest.
Language support for 11 languages including English, German, French, Russian, Japanese,
Traditional Chinese, Simplified Chinese, Korean, Spanish, Portuguese and Italian.
Real-time clock Time and date (user adjustable)
Measurement features
Automatic measurements Measurements are continuously updated. Cursors track last selected measurement.
Up to four measurements can be displayed on screen at any one time.
Voltage (scope channels only) Peak-to-peak, maximum, minimum, average, amplitude, top, base, overshoot, preshoot, RMS,
standard deviation (AC RMS), Ratio (dB)
Time Frequency, period, + width, – width and duty cycle on any channel.
Rise time, fall time, X at max Y (time at max volts), X at min Y (time at min volts), delay, and
phase on scope channels only.
Counter Built-in 5-digit frequency counter on any channel. Counts up to the scope’s bandwidth (1 GHz
max). The counter resolution can be increased to 8 digits with an external 10-MHz reference.
Threshold definition Variable by percent and absolute value; 10%, 50%, 90% default for time measurements
Cursors Manually or automatically placed readout of horizontal (X, ΔX, 1/ΔX) and vertical (Y, ΔY).
Tracking Cursors provides an additional mode for cursor positioning beyond the current manual
method. When cursor tracking is enabled, changing a cursor’s x-axis position results in the
yaxis cursor tracking the corresponding y-axis (voltage, current, etc.) value. Additionally logic
or scope channels can be displayed as binary or hex values.
Waveform math f (g(t))
g(t): { 1, 2, 3, 4, 1-2, 1+2, 1x2, 3-4, 3+4, 3x4}
f(t): { 1-2, 1+2, 1x2, 3-4, 3+4, 3x4, FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square
root √g(t) }
Where 1,2,3,4 represent analog input channels 1, 2, 3, and 4
Note: Channels 3 and 4 only available on MSO/DSO7xx4B models
Measurement statistics Statistical data for enabled measurements such as mean, min, max, standard deviation
and count
Precision Mode Automatic measurements, waveform math and FFT performed on up to 128Kpts data record
22
Performance characteristics (continued)
FFT
Points Up to 128 Kpts in precision mode
Source of FFT 1, 2, 1+2, 1-2, 1x2, MSO/DSO7xx4A: 3, 4, 3+4, 3-4, 3x4;
where 1, 2, 3, 4 represent the analog channel inputs 1, 2, 3, and 4
Window Rectangular, flattop, Hanning, Blackman Harris
Noise floor –50 to –90 dB depending on averaging
Amplitude Display in dBV, dBm at 50 Ω
Frequency resolution 0.05/time per div
Maximum frequency 50/time per div
Storage
Save/recall (non-volatile) 10 setups and traces can be saved and recalled internally.
Optional secure environment mode ensures setups and traces are stored to internal volatile
memory so data is erased when power is removed. Compliant to NISPOM Chapter 8
requirements.
Storage type and format USB 1.1 host ports on front and rear panels
Image formats: BMP (8-bit), BMP (24-bit), PNG (24-bit)
Data formats: X and Y (time/voltage) values in CSV format, ASCII XY and binary format and
.alb for offline viewing on a PC
Trace/setup formats: Recalled
I/O
Standard ports USB 2.0 high-speed device, two USB 1.1 host ports, 10/100BaseT LAN, XGA video output
Max transfer rate USB (USBTMC-USB488): 3.5 Mbytes/sec
100 Mbps LAN (TCP/IP): 1 Mbytes/sec
Supported printers via USB
For a list of currently supported printers visit www.agilent.com/find/InfiniiVision-printers
General characteristics
Physical size (WxHxD) 17.9” x 11.7” x 8.6” (45.4 cm x 29.8 cm x 22 cm) with legs extended, with screen cover on
17.9” x 10.9” x 6.8” (45.4 cm x 27.7 cm x 17.3 cm) with legs contracted, with screen cover on
Weight Net: 5.9 kg (13 lbs) Shipping: 9.3 kg (20.5 lbs)
Probe comp output Frequency ~1.2 kHz; Amplitude ~2.5 V
23
Performance characteristics (continued)
General characteristics (continued)
Trigger out When Triggers is selected (delay ~17 ns)
0 to 5 V into high impedance
0 to 2.5 V into 50 Ω
When Source Frequency or Source Frequency/8 is selected
0 to 580 mV into high impedance
0 to 290 mV into 50 Ω
Max frequency output: 350 MHz (in source frequency mode when terminated in 50 Ω)
125 MHz (in source frequency/8 mode when terminated in 50 Ω)
10 MHz ref in/out TTL out, 180 mV to 1 V amplitude with 0 to 2 V offset
Kensington lock Connection on rear panel for security
Power requirements
Line voltage range 100-120V, 50/60/400 Hz; 100-240V, 50/60 Hz auto ranging
Line frequency 50/60 Hz, 100-240 VAC; 400 Hz, 100-120 VAC
Power usage 120 W max
Environmental characteristics
Ambient temperature Operating -10 °C to +55 °C; non-operating –40 °C to +70 °C
Humidity Operating: Up to 95% relative humidity (non-condensing) at +40 °C
Non-operating: Up to 90% relative humidity at +65 °C
Altitude Operating to 4,570 m (15,000 ft); non-operating to 15,244 m (50,000 ft)
Vibration Agilent class B1 and MIL-PRF-28800F; class 3 random
Shock Agilent class B1 and MIL-PRF-28800F; class 3 random; (operating 30g, 1/2 sine,
11 ms duration, 3 shocks/axis along major axis, total of 18 shocks)
Pollution degree Normally only dry non-conductive pollution occurs.
Occasionally a temporary conductivity caused by condensation must be expected.
Typical operator noise 30 dBa at front of instrument, 35 dBa at rear of instrument.
Indoor use Rated for indoor use only
Other
Measurement categories CAT I
Regulatory information Safety IEC 61010-1:2001 / EN 61010-1:2001
Canada: CSA C22.2 No. 1010.1:1992
UL 61010B-1:2003
Supplementary information The product herewith complies with the requirements of the Low Voltage Directive
73/23/EEC and the EMC Directive 89/336/EEC, and carries the CE-marking accordingly.
The product was tested in a typical configuration with HP/Agilent test systems.
24
Ordering information
Accessories included:
Model number DSO70xxB MSO70xxB
Standard 3-year warranty
Standard probe
100 MHz : 10074D (default), N2871A (optional – as option 002)
350 MHz – 1GHz : 10073D (default), N2873A (optional – as option 002)
16 channel flying lead set logic probe (two pods with eight channels each)
54695-62301 Probe accessory pouch
Built-in help language support for English, French, German, Russian,
simplified Chinese, traditional Chinese, Korean, Spanish, Portuguese,
Japanese and Italian
Interface language support
GUI menus: English, simplified Chinese, traditional Chinese, Korean, Japanese
Key/knob overlay: English, simplified Chinese, traditional Chinese, Japanese
Printed user’s guide (option ABA for English, option AB2 for simplified Chinese,
option ABJ for Japanese)
Documentation CD (PDFs of Programmer’s Reference Guide,
User Guide, and Service Guide)
Agilent I/O libraries suite 15.0
Localized power cord
Front panel cover
Note: IntuiLink Data Capture software available free on Web at www.agilent.com/find/intuilink
25
Model Bandwidth Sample rate Memory depth Scope channels Digital channels
DSO7012B 100 MHz 2 GSa/s 8 Mpts 2
DSO7014B 100 MHz 2 GSa/s 8 Mpts 4
MSO7012B 100 MHz 2 GSa/s 8 Mpts 2 16
MSO7014B 100 MHz 2 GSa/s 8 Mpts 4 16
DSO7032B 350 MHz 2 GSa/s 8 Mpts 2
DSO7034B 350 MHz 2 GSa/s 8 Mpts 4
MSO7032B 350 MHz 2 GSa/s 8 Mpts 2 16
MSO7034B 350 MHz 2 GSa/s 8 Mpts 4 16
DSO7052B 500 MHz 4 GSa/s 8 Mpts 2
DSO7054B 500 MHz 4 GSa/s 8 Mpts 4
MSO7052B 500 MHz 4 GSa/s 8 Mpts 2 16
MSO7054B 500 MHz 4 GSa/s 8 Mpts 4 16
DSO7104B 1 GHz 4 GSa/s 8 Mpts 4
MSO7104B 1 GHz 4 GSa/s 8 Mpts 4 16
Ordering information (continued)
Options
Product Description
DSO to MSO upgrade* N2741A for DSO701xB
N2735A for DSO703xB
N2736A for DSO705xB
N2737A for DSO710xB
SEC Secure Environment Mode - Provides compliance with National Industrial Security
Program Operating Manual (NISPOM) Chapter 8 requirements
(factory-installed option only for new purchase)
A6J ANSI Z540 compliant calibration
*Includes a 54620-68701 logic cable kit, a label and an upgrade license to activate the MSO features. Installs in less than 5 minutes.
Serial data analysis applications
Option number – user installed Option number – factory installed Description
N5424A AMS CAN/LIN automotive triggering and decode
(4 and 4+16 channel models only)
N5423A LSS I2C/SPI serial decode option (for 4/4+16 channel
models only)
N5457A 232 RS-232/UART triggering and decode
(4 and 4+16 channel models only)
N5468A SND I2S Triggering and Decode (4 and 4+16 channel models only)
N5432C FLX FlexRay Measurements (4 and 4+16 channel models only)
N5469A 553 MIL-STD 1553 Triggering and Decode (4 and 4+16 channel models only)
PC-based applications Description
N5406A FPGA dynamic probe for Xilinx (MSO models only)
N5434A FPGA dynamic probe for Altera (MSO models only)
B4610A Offline viewing and analysis of MSO/DSO data on a PC
U1881A Power measurement and analysis application
E2690B ASAs Oscilloscope tools
Other measurement options
Option number – user installed Option number – factory installed Description
N5454A SGM Segmented memory
N5455A LMT Mask limit testing
Accessories
Product number Description
N2733A Soft carrying case for 7000B Series oscilloscope
N2732A Rackmount kit for 7000B Series oscilloscope
GemStar 5000
Transit case with foam molding customized for InfiniiVision 7000B Series available from GemStar Mfg. www.gemstarmfg.com
N2918A Evaluation kit
N4865A GPIB-to-LAN adapter
26
27
Agilent Technologies Oscilloscopes
Multiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications
For more information on Agilent
Technologies’ products, applications or
services, please contact your local Agilent
office. The complete list is available at:
www.agilent.com/find/contactus
Americas
Canada (877) 894 4414
Brazil (11) 4197 3600
Mexico 01800 5064 800
United States (800) 829 4444
Asia Pacific
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Other AP Countries (65) 375 8100
Europe & Middle East
Belgium 32 (0) 2 404 93 40
Denmark 45 45 80 12 15
Finland 358 (0) 10 855 2100
France 0825 010 700*
*0.125 €/minute
Germany 49 (0) 7031 464 6333
Ireland 1890 924 204
Israel 972-3-9288-504/544
Italy 39 02 92 60 8484
Netherlands 31 (0) 20 547 2111
Spain 34 (91) 631 3300
Sweden 0200-88 22 55
United Kingdom 44 (0) 118 927 6201
For other unlisted countries:
www.agilent.com/find/contactus
(BP2-19-13)
Product specifications and descriptions
in this document subject to change
without notice.
© Agilent Technologies, Inc. 2013
Published in USA, June 6, 2013
5990-4769EN
www.lxistandard.org
LAN eXtensions for Instruments puts
the power of Ethernet and the Web
inside your test systems. Agilent is a
founding member of the LXI consor-
tium.
Agilent Channel Partners
www.agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s
measurement expertise and product
breadth, combined with channel
partner convenience.
www.agilent.com
www.agilent.com/find/7000B
www.agilent.com/find/myagilent
A personalized view into the information
most relevant to you.
myAgilent
myAgilent
www.agilent.com/quality
www.agilent.com/find/AdvantageServices
Accurate measurements throughout the
life of your instruments.
Agilent Advantage Services