Electromagnetic Counter CSK Miniature, Electromagnetic Totalizing Counter * High-speed response (up to 35 cps) * Locking mechanism for errorless operation * Unique mechanism eliminates digit displacement during resets * UL listed model also available (File No. E67871) Ordering Information Numbering of digits Surface mounting Mounting method Resetting system Manual reset 4 digits 6 digits Wire-wrap terminals Terminal Locking mechanism Lead wires Flush mounting Wire-wrap terminals Lead wires No CSK4 CSK4-W CSK4-Y Yes CSK4-K CSK4-KW CSK4-YK CSK4-YKW Non-resetting No --- CSK4-LW CSK4-YL CSK4-YLW Manual reset No CSK6 CSK6-W CSK6-Y CSK6-YW Yes CSK6-K CSK6-KW CSK6-YK CSK6-YKW No --- CSK6-LW CSK6-YL CSK6-YLW Non-resetting CSK4-YW Note: 1. When placing your order, specify the desired supply voltage listed in Specifications and a UL listed model if required, in addition to the model number. 2. If a UL listed model is required, specify this in your order in addition to the desired model number. Specifications Ratings Supply voltage (see note) 100, 200 VAC, 50/60 Hz 6, 12, 24, 48, 100 VDC Operating voltage range 85% to 110% of rated voltage Power consumption AC: approx. 3 VA DC: approx. 3.5 W ON time rating Continuous rating Counting speed AC input: 15 cps (contact) (ON/OFF ratio: 1:1) DC input: 20 cps (contact) (ON/OFF ratio: 1:1) Character height 4 mm Note: The DC models have no polarity. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Rights Reserved. 1 CSK Characteristics Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute Vibration resistance Destruction: 16.7 Hz, 4 mm double amplitude Malfunction: 10 to 55 Hz, 0.5 mm double amplitude Shock resistance Destruction: 300 m/sec2 (approx. 30G) Malfunction: 50 m/sec2 (approx. 5G) Ambient temperature Operating: -10C to 45C Storage: -25C to 65C Ambient humidity 45% to 85% Life expectancy 50,000,000 counts Approved standards (see note) UL508 Weight 4-digit model: approx. 100 g 6-digit model: approx. 110 g Note: These standards apply to the -US models only. Dimensions CSK4-W/KW/LW CSK4/K Mounting Holes CSK4-W/KW/LW * @1 13.15 Reset button** 2 13.15 4 dia. 80 max. 32.6 4.5 11.3 22.6 6 dia. 12.60.2 6.8 6.8 3.5 dia. CSK4/K 20 (11.3) Locking mechanism** 7 M3.5 10 11.3 Two, 6.5 dia. 13.60.2 (11.3) 70.2 M3.5 10 * Lead wire length: approx. 250 ** CSK4-L and CSK4-LW are not provided with reset button nor locking mechanism. CSK4 and CSK4-W are not provided with locking mechanism. CSK6-W/KW/LW 4 dia. CSK6/K CSK6-W/KW/LW 18.40.2 * 3 dia. 3 dia. 21.8 6.8 @1 6.8 13.15 21.8 13.15 Reset button** 44.1 22.6 70.2 3.5 dia. 6 dia. 21.80.2 4 dia. 2 CSK6/K 80 max. 4.5 7 3.5 dia. 11.3 Two, 6.5 dia. 20 (11.3) Locking mechanism** 10 7 M3.5 * Lead wire length: approx. 250 ** CSK6-L and CSK6-LW are not provided with reset button nor locking mechanism. CSK6 and CSK6-W are not provided with locking mechanism. CSK4-YW/YKW/YLW 10 * 33 70.2 3.5 dia. M3.5 CSK4-Y/YK/YL 3.5 dia. 11.3 (11.3) 13.60.2 21.80.2 4 dia. CSK4-YW/YKW/YLW CSK4-Y/YK/YL 281 36.2 36.2 3.15 Reset button** Locking mechanism** 23 500.1 60 2 381 502 20 15 max. 31 Two, 3.5 dia. Two, M3 (or two, 3.5 dia.) 26 3 10 7 26 62.3 * Lead wire length: approx. 250 ** CSK4-YL and CSK4-YLW are not provided with reset button nor locking mechanism CSK4-Y and CSK4-YW are not provided with locking mechanism. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Rights Reserved. 2 CSK CSK6-YW/YKW/YLW CSK6-Y/YK/YL 3.5 dia. CSK6-YW/YKW/YLW CSK6-Y/YK/YL * Two, M3 (or two, 3.5 dia.) 12.9 47 8.9 44.5 281 47 491 630.2 Reset button** Locking mechanism** Two, 3.5 dia. 15 max. 31 20 7 23 630.1 72 2 3 10 26 26 62.3 * Lead wire length: approx. 250 ** CSK6-YL and CSK6-YLW are not provided with reset button nor locking mechanism. CSK6-Y and CSK6-YW are not provided with locking mechanism. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Rights Reserved. 3 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. 2008. 1 OMRON Corporation In the interest of product improvement, specifications are subject to change without notice. Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Rights Reserved. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: CSK4-YW-AC100 CSK6-Y AC100 CSK6-YKW AC100 CSKE-7RL AC100