Cylindrical Proximity Sensor E2A High quality for extra long life in daily use * sensing distance approximately 1.5 to 2 times longer than standard CENELEC proximity sensors * designed and tested for extra long life * IP67 and IP69k for highest protection in wet environments * consistent high quality level * DC 3-wire and DC 2-wire models * Normally open (NO), normally closed (NC) and antivalent (NO+NC) models * up to 30mm sensing distance * Stainless steel and brass housings * Pre-wired versions with different cable materials and diameters, M8 and M12 connector types, pre-wired types with cable end connectors Ordering Information DC 3-wire models (NO + NC: DC 4-wire) *2 Size Sensing distance Connection Body material Thread length (overall length) 27 (40) Pre-wired 49 (62) 27 (43) M12 connector 49 (65) Shiel2.0 mm ded 27 (39) M8 connector (3-pin) M8 connector (4-pin) M8 49 (61) 27 (39) Stainless steel*1 49 (61) 27 (40) Pre-wired 49 (62) 27 (43) M12 connector Nonshielded 49 (65) 4.0 mm M8 connector (3-pin) M8 connector (4 pin) 27 (39) 49 (61) 27 (39) 49 (61) Output configuration PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN PNP NPN Operation mode NO E2A-S08KS02-WP-B1 2M E2A-S08KS02-WP-C1 2M E2A-S08LS02-WP-B1 2M E2A-S08LS02-WP-C1 2M E2A-S08KS02-M1-B1 E2A-S08KS02-M1-C1 E2A-S08LS02-M1-B1 E2A-S08LS02-M1-C1 E2A-S08KS02-M5-B1 E2A-S08KS02-M5-C1 E2A-S08LS02-M5-B1 E2A-S08LS02-M5-C1 E2A-S08KS02-M3-B1 E2A-S08KS02-M3-C1 E2A-S08LS02-M3-B1 E2A-S08LS02-M3-C1 E2A-S08KN04-WP-B1 2M E2A-S08KN04-WP-C1 2M E2A-S08LN04-WP-B1 2M E2A-S08LN04-WP-C1 2M E2A-S08KN04-M1-B1 E2A-S08KN04-M1-C1 E2A-S08LN04-M1-B1 E2A-S08LN04-M1-C1 E2A-S08KN04-M5-B1 E2A-S08KN04-M5-C1 E2A-S08LN04-M5-B1 E2A-S08LN04-M5-C1 E2A-S08KN04-M3-B1 E2A-S08KN04-M3-C1 E2A-S08LN04-M3-B1 E2A-S08LN04-M3-C1 Operation mode NC E2A-S08KS02-WP-B2 2M E2A-S08KS02-WP-C2 2M E2A-S08LS02-WP-B2 2M E2A-S08LS02-WP-C2 2M E2A-S08KS02-M1-B2 E2A-S08KS02-M1-C2 E2A-S08LS02-M1-B2 E2A-S08LS02-M1-C2 E2A-S08KS02-M5-B2 E2A-S08KS02-M5-C2 E2A-S08LS02-M5-B2 E2A-S08LS02-M5-C2 E2A-S08KS02-M3-B2 E2A-S08KS02-M3-C2 E2A-S08LS02-M3-B2 E2A-S08LS02-M3-C2 E2A-S08KN04-WP-B2 2M E2A-S08KN04-WP-C2 2M E2A-S08LN04-WP-B2 2M E2A-S08LN04-WP-C2 2M E2A-S08KN04-M1-B2 E2A-S08KN04-M1-C2 E2A-S08LN04-M1-B2 E2A-S08LN04-M1-C2 E2A-S08KN04-M5-B2 E2A-S08KN04-M5-C2 E2A-S08LN04-M5-B2 E2A-S08LN04-M5-C2 E2A-S08KN04-M3-B2 E2A-S08KN04-M3-C2 E2A-S08LN04-M3-B2 E2A-S08LN04-M3-C2 *1. E2A 1 Size Sensing distance Connection Body material Thread length (overall length) 34 (50) Pre-wired Brass*3 56 (72) 34 (48) M12 connector Brass *3 56 (70) Shielded 4.0 mm M8 connector (3-pin) M8 connector (4-pin) 34 (48) Brass*3 56 (70) 34 (48) Brass *3 56 (70) M12 34 (50) Pre-wired Brass*3 56 (72) 34 (48) M12 connector Nonshielded Brass*3 56 (70) 8.0 mm M8 connector (3-pin) M8 connector (4-pin) 34 (48) Brass*3 56 (70) 34 (48) Brass *3 56 (70) 39 (59) Pre-wired Brass*3 61 (81) 39 (53) M12 connector Brass *3 61 (75) Shielded 8.0 mm M8 connector (3-pin) M8 connector (4-pin) 39 (53) Brass*3 61 (75) 39 (53) Brass *3 61 (75) M18 39 (59) Pre-wired Brass*3 61 (81) 39 (53) M12 connector Nonshielded 61 (75) 16.0 mm M8 connector (3-pin) M8 connector (4-pin) 2 Brass*3 39 (53) Brass*3 61 (75) 39 (53) Brass *3 61 (75) Output configuration Operation mode NO Operation mode NC Operation mode NO + NC PNP E2A-M12KS04-WP-B1 2M E2A-M12KS04-WP-B2 2M NPN E2A-M12KS04-WP-C1 2M E2A-M12KS04-WP-C2 2M E2A-M12KS04-WP-C3 2M PNP E2A-M12LS04-WP-B1 2M E2A-M12LS04-WP-B2 2M E2A-M12LS04-WP-B3 2M NPN E2A-M12LS04-WP-C1 2M E2A-M12LS04-WP-C2 2M E2A-M12LS04-WP-C3 2M PNP E2A-M12KS04-M1-B1 E2A-M12KS04-M1-B2 E2A-M12KS04-M1-B3 NPN E2A-M12KS04-M1-C1 E2A-M12KS04-M1-C2 E2A-M12KS04-M1-C3 E2A-M12KS04-WP-B3 2M PNP E2A-M12LS04-M1-B1 E2A-M12LS04-M1-B2 E2A-M12LS04-M1-B3 NPN E2A-M12LS04-M1-C1 E2A-M12LS04-M1-C2 E2A-M12LS04-M1-C3 PNP E2A-M12KS04-M5-B1 E2A-M12KS04-M5-B2 n.a. NPN E2A-M12KS04-M5-C1 E2A-M12KS04-M5-C2 n.a. PNP E2A-M12LS04-M5-B1 E2A-M12LS04-M5-B2 n.a. NPN E2A-M12LS04-M5-C1 E2A-M12LS04-M5-C2 n.a. PNP E2A-M12KS04-M3-B1 E2A-M12KS04-M3-B2 n.a. NPN E2A-M12KS04-M3-C1 E2A-M12KS04-M3-C2 n.a. PNP E2A-M12LS04-M3-B1 E2A-M12LS04-M3-B2 n.a. NPN E2A-M12LS04-M3-C1 E2A-M12LS04-M3-C2 n.a. E2A-M12KN08-WP-B3 2M PNP E2A-M12KN08-WP-B1 2M E2A-M12KN08-WP-B2 2M NPN E2A-M12KN08-WP-C1 2M E2A-M12KN08-WP-C2 2M E2A-M12KN08-WP-C3 2M PNP E2A-M12LN08-WP-B1 2M E2A-M12LN08-WP-B2 2M E2A-M12LN08-WP-B3 2M NPN E2A-M12LN08-WP-C1 2M E2A-M12LN08-WP-C2 2M E2A-M12LN08-WP-C3 2M PNP E2A-M12KN08-M1-B1 E2A-M12KN08-M1-B2 E2A-M12KN08-M1-B3 NPN E2A-M12KN08-M1-C1 E2A-M12KN08-M1-C2 E2A-M12KN08-M1-C3 PNP E2A-M12LN08-M1-B1 E2A-M12LN08-M1-B2 E2A-M12LN08-M1-B3 NPN E2A-M12LN08-M1-C1 E2A-M12LN08-M1-C2 E2A-M12LN08-M1-C3 PNP E2A-M12KN08-M5-B1 E2A-M12KN08-M5-B2 n.a. NPN E2A-M12KN08-M5-C1 E2A-M12KN08-M5-C2 n.a. PNP E2A-M12LN08-M5-B1 E2A-M12LN08-M5-B2 n.a. NPN E2A-M12LN08-M5-C1 E2A-M12LN08-M5-C2 n.a. PNP E2A-M12KN08-M3-B1 E2A-M12KN08-M3-B2 n.a. NPN E2A-M12KN08-M3-C1 E2A-M12KN08-M3-C2 n.a. PNP E2A-M12LN08-M3-B1 E2A-M12LN08-M3-B2 n.a. NPN E2A-M12LN08-M3-C1 E2A-M12LN08-M3-C2 n.a. PNP E2A-M18KS08-WP-B1 2M E2A-M18KS08-WP-B2 2M E2A-M18KS08-WP-B3 2M NPN E2A-M18KS08-WP-C1 2M E2A-M18KS08-WP-C2 2M E2A-M18KS08-WP-C3 2M PNP E2A-M18LS08-WP-B1 2M E2A-M18LS08-WP-B2 2M E2A-M18LS08-WP-B3 2M NPN E2A-M18LS08-WP-C1 2M E2A-M18LS08-WP-C2 2M E2A-M18LS08-WP-C3 2M PNP E2A-M18KS08-M1-B1 E2A-M18KS08-M1-B2 E2A-M18KS08-M1-B3 NPN E2A-M18KS08-M1-C1 E2A-M18KS08-M1-C2 E2A-M18KS08-M1-C3 PNP E2A-M18LS08-M1-B1 E2A-M18LS08-M1-B2 E2A-M18LS08-M1-B3 NPN E2A-M18LS08-M1-C1 E2A-M18LS08-M1-C2 E2A-M18LS08-M1-C3 PNP E2A-M18KS08-M5-B1 E2A-M18KS08-M5-B2 n.a. NPN E2A-M18KS08-M5-C1 E2A-M18KS08-M5-C2 n.a. PNP E2A-M18LS08-M5-B1 E2A-M18LS08-M5-B2 n.a. NPN E2A-M18LS08-M5-C1 E2A-M18LS08-M5-C2 n.a. PNP E2A-M18KS08-M3-B1 E2A-M18KS08-M3-B2 n.a. NPN E2A-M18KS08-M3-C1 E2A-M18KS08-M3-C2 n.a. PNP E2A-M18LS08-M3-B1 E2A-M18LS08-M3-B2 n.a. NPN E2A-M18LS08-M3-C1 E2A-M18LS08-M3-C2 n.a. E2A-M18KN16-WP-B3 2M PNP E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2M NPN E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M E2A-M18KN16-WP-C3 2M PNP E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M E2A-M18LN16-WP-B3 2M NPN E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M E2A-M18LN16-WP-C3 2M PNP E2A-M18KN16-M1-B1 E2A-M18KN16-M1-B2 E2A-M18KN16-M1-B3 NPN E2A-M18KN16-M1-C1 E2A-M18KN16-M1-C2 E2A-M18KS16-M1-C3 PNP E2A-M18LN16-M1-B1 E2A-M18LN16-M1-B2 E2A-M18LS16-M1-B3 NPN E2A-M18LN16-M1-C1 E2A-M18LN16-M1-C2 E2A-M18LS16-M1-C3 PNP E2A-M18KN16-M5-B1 E2A-M18KN16-M5-B2 n.a. NPN E2A-M18KN16-M5-C1 E2A-M18KN16-M5-C2 n.a. PNP E2A-M18LN16-M5-B1 E2A-M18LN16-M5-B2 n.a. NPN E2A-M18LN16-M5-C1 E2A-M18LN16-M5-C2 n.a. PNP E2A-M18KN16-M3-B1 E2A-M18KN16-M3-B2 n.a. NPN E2A-M18KN16-M3-C1 E2A-M18KN16-M3-C2 n.a. PNP E2A-M18LN16-M3-B1 E2A-M18LN16-M3-B2 n.a. NPN E2A-M18LN16-M3-C1 E2A-M18LN16-M3-C2 n.a. Inductive Sensors Size Sensing distance Connection Body material Thread length (overall length) 44 (64) Pre-wired Brass *3 66 (86) 44 (58) M12 connector Brass*3 66 (80) Shielded 15.0 mm M8 connector (3-pin) M8 connector (4-pin) M30 44 (58) Brass*3 66 (80) 44 (58) Brass*3 66 (80) 20.0 mm Pre-wired 30.0 mm 66 (86) 20.0 mm 44 (58) (See note.) M12 connector Nonshielded Brass*3 44 (64) (See note.) Brass*3 30.0 mm 66 (80) 20.0 mm 44 (58) (See note.) 30.0 mm 20.0 mm 30.0 mm M8 connector (3-pin) M8 connector (4-pin) Brass*3 66 (80) Brass*3 44 (58) (See note.) 66 (80) Output configuration Operation mode NO Operation mode NC Operation mode NO + NC PNP E2A-M30KS15-WP-B1 2M E2A-M30KS15-WP-B2 2M E2A-M30KS15-WP-B3 2M NPN E2A-M30KS15-WP-C1 2M E2A-M30KS15-WP-C2 2M E2A-M30KS15-WP-C3 2M PNP E2A-M30LS15-WP-B1 2M E2A-M30LS15-WP-B2 2M E2A-M30LS15-WP-B3 2M NPN E2A-M30LS15-WP-C1 2M E2A-M30LS15-WP-C2 2M E2A-M30LS15-WP-C3 2M PNP E2A-M30KS15-M1-B1 E2A-M30KS15-M1-B2 E2A-M30KS15-M1-B3 NPN E2A-M30KS15-M1-C1 E2A-M30KS15-M1-C2 E2A-M30KS15-M1-C3 PNP E2A-M30LS15-M1-B1 E2A-M30LS15-M1-B2 E2A-M30LS15-M1-B3 NPN E2A-M30LS15-M1-C1 E2A-M30LS15-M1-C2 E2A-M30LS15-M1-C3 PNP E2A-M30KS15-M5-B1 E2A-M30KS15-M5-B2 n.a. NPN E2A-M30KS15-M5-C1 E2A-M30KS15-M5-C2 n.a. PNP E2A-M30LS15-M5-B1 E2A-M30LS15-M5-B2 n.a. NPN E2A-M30LS15-M5-C1 E2A-M30LS15-M5-C2 n.a. PNP E2A-M30KS15-M3-B1 E2A-M30KS15-M3-B2 n.a. NPN E2A-M30KS15-M3-C1 E2A-M30KS15-M3-C2 n.a. PNP E2A-M30LS15-M3-B1 E2A-M30LS15-M3-B2 n.a. NPN E2A-M30LS15-M3-C1 E2A-M30LS15-M3-C2 n.a. PNP E2A-M30KN20-WP-B1 2M E2A-M30KN20-WP-B2 2M E2A-M30KN20-WP-B3 2M E2A-M30KN20-WP-C3 2M NPN E2A-M30KN20-WP-C1 2M E2A-M30KN20-WP-C2 2M PNP E2A-M30LN30-WP-B1 2M E2A-M30LN30-WP-B2 2M E2A-M30LN30-WP-B3 2M NPN E2A-M30LN30-WP-C1 2M E2A-M30LN30-WP-C2 2M E2A-M30LN30-WP-C3 2M PNP E2A-M30KN20-M1-B1 E2A-M30KN20-M1-B2 E2A-M30KN20-M1-B3 NPN E2A-M30KN20-M1-C1 E2A-M30KN20-M1-C2 E2A-M30KN20-M1-C3 PNP E2A-M30LN30-M1-B1 E2A-M30LN30-M1-B2 E2A-M30LN30-M1-B3 NPN E2A-M30LN30-M1-C1 E2A-M30LN30-M1-C2 E2A-M30LN30-M1-C3 PNP E2A-M30KN20-M5-B1 E2A-M30KN20-M5-B2 n.a. NPN E2A-M30KN20-M5-C1 E2A-M30KN20-M5-C2 n.a. PNP E2A-M30LN30-M5-B1 E2A-M30LN30-M5-B2 n.a. NPN E2A-M30LN30-M5-C1 E2A-M30LN30-M5-C2 n.a. PNP E2A-M30KN20-M3-B1 E2A-M30KN20-M3-B2 n.a. NPN E2A-M30KN20-M3-C1 E2A-M30KN20-M3-C2 n.a. PNP E2A-M30LN30-M3-B1 E2A-M30LN30-M3-B2 n.a. NPN E2A-M30LN30-M3-C1 E2A-M30LN30-M3-C2 n.a. *1. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS). Please contact your OMRON representative for other stainless steel materials. *2. Please contact your OMRON representative for DC 2-wire models. *3. Stainless steel models are also available. Please contact your OMRON representative. Note:M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from the surrounding metal. Standard sensing models are thus available. E2A 3 Connectivity The E2A sensors are available with the following connectors and cable materials: Pre-wired models Pre-wired models with cable end connectors Standard cable lengths are 2m and 5m. For other cable lengths please contact your OMRON representative. All pre-wired models can be fitted with cable and connectors. Standard cable material: PVC (dia 4mm) -WP Other available cable materials and sizes: Standard cable end connectors: - M12 - M8 (4 pin) - M8 (3 pin) M1J M3J M5J - PVC (dia 6mm) -WS Other cable end connectors are available on request. - PUR/PVC - PUR jacket (dia 4mm) -WA Connector models - PUR/PVC - PUR jacket (dia 6mm) -WB - PVC robotic cable (dia 4mm) -WR Standard connectors: M12, M8 (4 or 3 pin) 4 -M1, -M3, -M5 Inductive Sensors Model Number Legend E2A@-@@@@@-@-@@-@@ 1 2 3 4 5 6 7 8 9 10 11 12 Example: E2A-M12LS04-M1-B1 Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO E2A-S08KN04-WP-B1 5M Standard, M8 stainless steel, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m 1. Basic name E2A 2. Sensing technology Blank: Standard double distance 3. Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel 4. Housing size 8. Kind of connection WP: pre-wired, PVC, dia 4mm (standard) WS: pre-wired, PVC, dia 6mm WR: pre-wired, PVC, robotic cable, dia 4mm WA: pre-wired, PUR/PVC (PUR jacket), dia 4mm WB: pre-wired, PUR/PVC (PUR jacket), dia 6mm M1: M12 connector (4 pin) * 08: 8 mm M3: M8 connector (4 pin) 12: 12 mm M5: M8 connector (3 pin) 18: 18 mm 30: 30 mm 5. Barrel length K: Standard length L: Long body 6. Shield M1J pre-wired with M12 cable end connector (4 pin) M3J pre-wired with M8 cable end connector (4 pin) M5J pre-wired with M8 cable end connector (3 pin) 9. Power source and output B: DC, 3-wire, PNP open collector S: Shielded C: DC, 3-wire, NPN open collector N: Non-shielded D: DC, 2-wire E: DC, 3-wire, NPN voltage output F: DC, 3-wire, PNP voltage output 7. Sensing distance Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm 10.Operation mode 1: Normally open (NO) 2: Normally closed (NC) 3: Antivalent (NO+NC) 11.Specials (e.g., cable material, oscillating frequency) 12.Cable length Blank: Connector type Numeral: Cable length Note: *In case of DC 2-wire models the M12 connector identifier is '-M1G' E2A 5 Specifications DC 3-wire Models / DC 4-wire (NO+NC) Size Type Item Sensing distance Setting distance Differential travel Target Standard target (mild steel ST37) Response frequency (See note 1.) Power supply voltage (operating voltage range) Current consumption (DC 3-wire) Output type Control output Load current (See note 2.) Residual voltage Indicator Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence (See note 2.) Ambient humidity Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Standard and listings (See note 3.) Connection method Weight (packaged) Pre-wired model Connector model Case Sensing surface Material Cable Clamping nut M8 M12 Shielded Non-shielded Shielded Non-shielded E2A-S08@S02-@@-B1 E2A-S08@N04-@@-B1 E2A-M12@S04-@@-B@ E2A-M12@N08-@@-B@ E2A-S08@S02-@@-C1 E2A-S08@N04-@@-C1 E2A-M12@S04-@@-C@ E2A-M12@N08-@@-C@ E2A-S12@S04-@@-B@ E2A-S12@N08-@@-B@ E2A-S12@S04-@@-C@ E2A-S12@N08-@@-C@ 2 mm 10% 4 mm 10% 4 mm 10% 8 mm 10% 0 to 1.6 mm 0 to 3.2 mm 0 to 3.2 mm 0 to 6.4 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) 8x 8x 1 mm 12x 12x 1 mm 12x 12x 1 mm 24x 24x 1 mm 1,500 Hz 1,000 Hz 1,000 Hz 800 Hz 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) 10 mA max. -B models: PNP open collector -C models: NPN open collector 200 mA max. (32 VDC max.) 2 V max. (under load current of 200 mA with cable length of 2 m) Operation indicator (Yellow LED) -B1/-C1 models: NO -B2/-C2 models: NC -B3/ -C3 models: NO+NC For details, refer to the timing charts. (See note 4.) Output reverse polarity protection, Power source Power source circuit reverse polarity protection, circuit reverse polarity protection, Surge suppresSurge suppressor, Short-circuit protection sor, Short-circuit protection Operating: -40 C to 70 C, Storage: -40 C to 85 C (with no icing or condensation) 10% max. of sensing distance at 23 C within temperature range of -25 C to 70 C 15% max. of sensing distance at 23 C within temperature range of -40 C to 70 C Operating: 35% to 95%, Storage: 35% to 95% 1% max. of sensing distance in rated voltage range 15% 50 M min. (at 500 VDC) between current carry parts and case 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions 500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions IP67 after IEC 60529 IP69k after DIN 40050 EMC after EN60947-5-2 Pre-wired models (standard is dia 4mm PVC cable with length = 2m). Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12 connectors. Approx. 65 g Approx. 85 g M12 connector models: Approx. 20 g Approx. 35 g M8 connector models: Approx. 15 g Stainless steel Brass-nickel plated or stainless steel PBT Standard cable is PVC dia 4mm. For other cable materials or diameters please refer to chapter 'Connectivity' Brass-nickel plated for brass models stainless Brass-nickel plated steel for steel models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40C and -25C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max., 3. For USA and Canada: use class 2 circuit only. 4. -B3/ -C3 NO+NC models are available in M12, M18 and M30 housings with M12 connectors, pre-wired and with cable end connectors. 6 Inductive Sensors DC 3-wire Models / DC 4-wire (NO+NC) Size Type Item Sensing distance Setting distance Differential travel Target Standard target (mild steel ST37) Response frequency (See note 1.) Power supply voltage (operating voltage range) Current consumption (DC 3-wire) Output type Control output Load current (See note 2.) Residual voltage Indicator Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence (See note 2.) Ambient humidity Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Standard and listings (See note 3.) Connection method Weight (pakkaged) Material Pre-wired model M18 Shielded Non-shielded E2A-M18@S08-@@-B@ E2A-M18@S08-@@-C@ E2A-S18@S08-@@-B@ E2A-S18@S08-@@-C@ E2A-M18@N16-@@-B@ E2A-M18@N16-@@-C@ E2A-S18@N16-@@-B@ E2A-S18@N16-@@-C@ Shielded M30 Non-shielded E2A-M30@S15-@@-B@ E2A-M30KN20-@@-B@ E2A-M30@S15-@@-C@ E2A-M30KN20-@@-C@ E2A-S30@S15-@@-B@ E2A-S30KN20-@@-B@ E2A-S30@S15-@@-C@ E2A-S30KN20-@@-C@ Non-shielded E2A-M30LN30-@@-B@ E2A-M30LN30-@@-C@ E2A-S30LN30-@@-B@ E2A-S30LN30-@@-C@ 8 mm10% 16 mm10% 15 mm10% 20 mm10% 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm 0 to 16 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) 30 mm10% 0 to 24 mm 24x 24x 1 mm 48x 48x 1 mm 45x 45x 1 mm 60x 60x 1 mm 90x 90x 1 mm 500 Hz 400 Hz 250 Hz 100 Hz 100 Hz 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) 10 mA max. -B models: PNP open collector -C models: NPN open collector 200 mA max. (32 VDC max.) 2 V max. (under load current of 200 mA with cable length of 2 m) Operation indicator (Yellow LED) -B1/-C1 models: NO -B2/-C2 models: NC -B3/ -C3 models: NO+NC For details, refer to the timing charts. Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: -40 C to 70 C, Storage: -40 C to 85 C (with no icing or condensation) 10% max. of sensing distance at 23 C within temperature range of -25 C to 70 C 15% max. of sensing distance at 23 C within temperature range of -40 C to 70 C Operating: 35% to 95%, Storage: 35% to 95% 1% max. of sensing distance in rated voltage range 15% 50 M min. (at 500 VDC) between current carry parts and case 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions IP67 after IEC 60529 IP69k after DIN 40050 EMC after EN60947-5-2 Pre-wired models (standard is dia 4mm PVC cable with length = 2m). Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12 connectors. Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g Connector model Approx. 70 g Case Sensing surface Cable Clamping nut Brass-nickel plated or stainless steel PBT Standard cable is PVC dia 4mm. For other cable materials or diameters please refer to chapter 'Connectivity' brass-nickel plated for brass models stainless steel for steel models Approx. 200 g Approx. 200 g Approx. 260 g Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40C and -25C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max. 3. For USA and Canada: use class 2 circuit only. E2A 7 DC 2-wire Models Size Type Item Sensing distance Setting distance Differential travel Target Standard target Response frequency (See note 1.) Power supply voltage (operating voltage range) Leakage current Output type Load current Control (See note 2.) output Residual voltage Indicator (see timing chart) Operation mode Protection circuit Ambient temperature Temperature influence Ambient humidity Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Standard and listings (See note 3.) Connection method Weight (packaged) Pre-wired model Connector model Case Sensing surface Material Cable Clamping nut M8 Shielded E2A-S08@S02-D@ M12 Non-shielded E2A-S08@N04-D@ Shielded E2A-M12@S04-D@ E2A-S12@S04-D@ 4 mm 10% 0 to 3.2 mm 2 mm 10% 4 mm 10% 0 to 1.6 mm 0 to 3.2 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) 8x 8x 1 mm 12x 12x 1 mm 12x 12x 1 mm 1,500 Hz 1,000 Hz 1,000 Hz 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) 0.8 mA max. DC 2 wire type Non-shielded E2A-M12@N08-D@ E2A-S12@N08-D@ 8 mm 10% 0 to 6.4 mm 24x 24x 1 mm 800 Hz 3 to 100 mA 3 V max. (under load current of 100 mA with cable length of 2 m) NO type: Operation indicator (Yellow), Setting indicator (Red) NC type: Operation indicator (Yellow) -D1 models: NO -D2 models: NC Surget suppressor, Short circuit protection Operating: -40 C to 70 C, Storage: -40 C to 85 C (with no icing or condensation) 10% max. of sensing distance at 23 C within temperature range of -25 C to 70 C 15% max. of sensing distance at 23 C within temperature range of -40 C to 70 C Operating: 35% to 95%, Storage: 35% to 95% 1% max. of sensing distance in rated voltage range 15% 50 M min. (at 500 VDC) between current carry parts and case 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions 500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions IP67 after IEC 60529 IP69k after DIN 40050 EMC after EN60947-5-2 Pre-wired models (standard is dia 4mm PVC cable with length = 2m). Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12 connectors. Approx. 65 g Approx. 85 g M12 connector models: Approx. 20 g Approx. 35 g M8 connector models: Approx. 15 g Stainless steel Brass-nickel plated or stainless steel PBT Standard cable is PVC dia 4mm. For other cable materials or diameters please refer to chapter 'Connectivity' Brass-nickel plated for brass models stainless Brass-nickel plated steel for steel models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40C and -25C and a power voltage between 30 and 32 VDC, use a load current of 50 mA max. 3. For USA and Canada: use class 2 circuit only. 8 Inductive Sensors DC 2-wire Models Size Type M18 Shielded E2A-M18@S08-D@ E2A-S18@S08-D@ M30 Non-shielded E2A-M18@N16-D@ E2A-S18@N16-D@ Shielded E2A-M30@S15-D@ E2A-S30@S15-D@ Item Sensing distance 8 mm 10% 16 mm 10% 15 mm 10% Setting distance 0 to 6.4 mm 0 to 12.8 mm 0 to 12 mm Differential travel Target 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) Standard target 24x24x1 mm Response frequency (See note 1.) Power supply voltage (operating voltage range) Leakage current Output type Load current Control (See note 2.) output Residual voltage 500 Hz 400 Hz 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) 0.8 mA max. DC 2 wire type Indicator (see timing chart) Operation mode Protection circuit Ambient temperature Temperature influence Ambient humidity Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Standard and listings (See note 3.) Connection method Weight (packaged) Pre-wired model Connector model Case Sensing surface Material Cable Clamping nut 48x48x1 mm 45x45x1 mm 250 Hz Non-shielded E2A-M30@N30-D@ E2A-M30@N20-D@ E2A-S30@N30-D@ E2A-S30@N20-D@ Short body: 20 m 10% Long body: 30 m 10% Short body: 0 to 16 mm Long body: 0 to 24 mm Short body: 60x60x1 mm Long body: 90x90x1mm 100 Hz 3 to 100 mA 3 V max. (under load current of 100 mA with cable length of 2 m) NO type: Operation indicator (Yellow), Setting indicator (Red) NC type: Operation indicator (Yellow) -D1 models: NO -D2 models: NC Surget suppressor, Short circuit protection Operating: -40 C to 70 C, Storage: -40 C to 85 C (with no icing or condensation) 10% max. of sensing distance at 23 C within temperature range of -25 C to 70 C 15% max. of sensing distance at 23 C within temperature range of -40 C to 70 C Operating: 35% to 95%, Storage: 35% to 95% 1% max. of sensing distance in rated voltage range 15% 50 M min. (at 500 VDC) between current carry parts and case 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions 500 m/s2, 10 times each in X, Y and Z directions IP67 after IEC 60529 IP69k after DIN 40050 EMC after EN60947-5-2 Pre-wired models (standard is dia 4mm PVC cable with length = 2m). Please see chapter 'Connectivity' for details on different cable materials and lenghts and M8 or M12 connectors. short body: 280 g Approx. 160 g Approx. 280 g long body: 370 g short body: 200 g Approx. 70 g Approx. 200 g long body: 260 g Brass-nickel plated or stainless steel PBT Standard cable is PVC dia 4mm. For other cable materials or diameters please refer to chapter 'Connectivity' brass-nickel plated for brass models stainless steel for steel models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40C and -25C and a power voltage between 30 and 32 VDC, use a load current of 50 mA max. 3. For USA and Canada: use class 2 circuit only. E2A 9 Engineering Data Operating Range (Typical) Non-shielded Models 18 Sensing distance X (mm) Sensing distance X (mm) Shielded Models E2A-M30@S15 16 14 Y 12 X E2A-M18@S08 10 8 E2A-M12@S04 E2A-S08@S02/ E2A-M08@S02 6 4 35 E2A-M30LN30 30 Y 25 X E2A-M30KN20 20 E2A-M18@N16 15 E2A-M12@N08 10 E2A-S08@N04/ E2A-M08@N04 5 2 0 -30 -20 -10 0 10 20 0 -50 -40 -30 -20 -10 30 0 10 20 30 40 50 Distance Y (mm) Distance Y (mm) Influence of Sensing Object Size and Materials 2.5 @d X t = 1 mm Iron 2.0 Stainless steel (SUS303) 1.5 Brass 1.0 Aluminum E2A-M12@S04/ E2A-S12@S04 E2A-M18@S08/E2A-S18@S08 Sensing distance X (mm) Sensing distance X (mm) E2A-S08@S02 Sensing distance X (mm) Shielded Models 5.0 @d X t = 1 mm Iron 4.0 Stainless steel (SUS303) 3.0 Brass Aluminum 2.0 Copper Copper 8.0 Iron 7.0 6.0 5.0 Brass 4.0 Aluminum 3.0 2.0 0.5 Stainless steel (SUS303) Copper @d X 1.0 t = 1 mm 1.0 0 5 10 15 20 25 Side length of sensing object d (mm) 0 5 10 15 20 25 30 35 Side length of sensing object d (mm) 0 10 20 30 40 50 60 Side length of sensing object d (mm) Sensing distance X (mm) E2A-M30@S15/ E2A-S30@S15 20 @d X t = 1 mm 16 Iron 12 Stainless steel (SUS303) 8 Brass Aluminum Copper 4 0 10 20 30 40 50 60 70 80 Side length of sensing object d (mm) 10 Inductive Sensors Non-shielded Models @d X E2A-M12@N08/E2A-S12@N08 t = 1 mm Iron 4.0 Stainless steel (SUS303) 3.0 Brass 2.0 Aluminum @d X t = 1 mm Iron 8 6 Stainless steel (SUS303) 4 Brass 20 30 40 0 50 Sensing distance X (mm) Sensing distance X (mm) @d X t = 1 mm Iron 15 Stainless steel (SUS303) 10 t = 1 mm 10 20 30 Iron 12 Stainless steel (SUS303) Brass 8 40 50 0 20 40 60 80 Side length of sensing object d (mm) E2A-M30LN30/E2A-S30LN30 E2A-M30KN20/E2A-S30KN20 20 X 16 4 Side length of sensing object d (mm) Side length of sensing object d (mm) 25 @d Aluminum Copper Copper 2 10 20 Aluminum Copper 1.0 0 E2A-M18@N16/E2A-S18@N16 10 Sensing distance X (mm) 5.0 Sensing distance X (mm) Sensing distance X (mm) E2A-S08@N04 Brass 35 @d 30 X Iron t = 1 mm 25 Stainless steel (SUS303) 20 Brass 15 Aluminum Copper Aluminum 10 Copper 5 5 0 20 40 60 80 100 Side length of sensing object d (mm) E2A 0 20 40 60 80 100 Side length of sensing object d (mm) 11 Operation DC 3-wire models PNP Output Operation mode Model Timing chart Non-sensing zone Output circuit Sensing zone Brown Proximity Sensor +V Sensing object (%) 100 Proximity Sensor main circuits 0 Rated sensing distance Load ON OFF NO Black (See note 1.) E2A-@-@-B1 ON OFF Blue 0V Yellow indicator Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M12 Connector M8 connector M8 Connector Pin Arrangement (3 pin) (4 pin) (See note 2.) Pin Arrangement Pin Arrangement (See note 2.) 4 1 2 2 3 1 4 4 1 3 3 Note 2: Pin 2 of the M12 connector and M8 connector is not used. Non-sensing zone Sensing zone Brown Proximity Sensor +V Sensing object (%) 100 ) Rated sensing distance (See note 1.) Load ON OFF NC Black (M8 connector: Proximity Sensor main circuits 0 E2A-@-@-B2 Blue ON OFF 0V Yellow indicator Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M8 Connector M12 Connector M8 connector (4 pin) (3 pin) Pin Arrangement Pin Arrangement (See note 2.) Pin Arrangement (See note 2.) 4 1 2 4 1 2 3 1 4 3 3 Note 2: Pin 4 of the M12 connector and M8 connector is not used. Non-sensing zone Sensing zone Brown 1 Proximity Sensor +V Sensing object (%) 100 Proximity Sensor main circuits 0 Rated sensing distance Load ON OFF ON NO + NC E2A-@-@-B3 Black 4 NO output Yellow indicator White 2 NC output NO output OFF ON OFF Load NC output Blue 3 0V M12 Connector Pin Arrangement 1 2 4 3 12 Inductive Sensors DC 3-wire models NPN Output Operation mode Model Timing chart Non-sensing zone Output circuit Sensing zone Brown Proximity Sensor Sensing object (%) Load 100 Proximity Sensor main circuits 0 Rated sensing distance ON OFF NO +V E2A-@-@-C1 ON OFF (See note 1.) Black Blue 0V Yellow indicator Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M8 Connector M12 Connector M8 connector (4 pin) (3 pin) Pin Arrangement Pin Arrangement (See note 2.) Pin Arrangement (See note 2.) 4 1 2 4 2 3 1 4 1 3 3 Note 2: Pin 2 of the M12 connector and M8 connector is not used. Non-sensing zone Sensing zone Brown Proximity Sensor Sensing object (%) Load 100 Proximity Sensor main circuits 0 Rated sensing distance ON OFF NC +V E2A-@-@-C2 (M8 connector: ) Blue 0V Yellow indicator ON OFF (See note 1.) Black Control output Note 1: With M8 connector models, there is no output reverse polarity protection diode. M8 Connector M12 Connector M8 connector (4 pin) (3 pin) Pin Arrangement Pin Arrangement (See note 2.) Pin Arrangement (See note 2.) 4 1 2 4 1 2 3 4 1 3 3 Note 2: Pin 4 of the M12 connector and M8 connector is not used. Non-sensing zone Sensing zone Brown 1 Proximity Sensor Sensing object (%) 100 Rated sensing distance Load OFF ON E2A-@-@-C3 Black 4 NO output Proximity Sensor main circuits 0 ON NO + NC +V Load Yellow indicator White 2 NO output OFF ON OFF NC output NC output Blue 3 0V M12 Connector Pin Arrangement 1 2 4 3 E2A 13 DC 2-wire models Output Circuit Diagrams (Operation) Operation mode Model Timing chart Non-sensing zone Output circuit Sensing zone Proximity Sensor Load Brown +V Sensing object (%) 80 0 Rated sensing distance NO 100 E2A-@-D1 ON OFF ON OFF ON Blue Yellow indicator Load can be connected to +V or 0V side. Red indicator Control output OFF Non-sensing zone Sensing zone 0V M12 Connector Pin Arrangement 1 2 4 3 Proximity Sensor Load Brown +V Sensing object (%) E2A-@-D2 0 Rated sensing distance NC 100 ON OFF Blue Load can be connected to +V or 0V side. ON OFF Control output M12 Connector Pin Arrangement 14 0V Yellow indicator 1 2 4 3 Inductive Sensors Dimensions Note: All units are in millimeters unless otherwise indicated. Pre-wired Models (Shielded) Pre-wired Models (Non-shielded) E2A-S08KS02-WP-@@ E2A-S08KN04-WP-@@ 40 40 27 3 13 13 5 27 3 6 5 5.8 dia. (See note 1.) Indicator (See note 2.) Two, clamping nuts M8x1 Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M12KS04-WP-@@/E2A-S12KS04-WP-@ (See note 1.) Indicator (See note 2.) M8x1 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M12KN08-WP-@@/E2A-S12KN08-WP-@ 50.3 50.3 34 4 34 17 4 17 7 7 7 9.2 dia. (See note 1.) Indicator (See note 2.) M12x1 (See note 1.) Indicator (See note 2.) M12x1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) 3. for NO+NC (-B3 / -C3) models the total length is 4 mm longer E2A-M18KS08-WP-@@/E2A-S18KS08-WP-@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) 3. for NO+NC (-B3 / -C3) models the total length is 4 mm longer E2A-M18KN16-WP-@@/E2A-S18KN16-WP-@ 59.5 59.5 39 4 24 10 24 10 39 4 10 15.1 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M18x1 M18x1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M30KS15-WP-@@/E2A-S30KS15-WP-@ Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M30KN20-WP-@@/E2A-S30KN20-WP-@ 64.5 64.5 44 44 5 36 15 36 10 5 10 26.4 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M30x1.5 M30x1.5 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) 15 E2A-S08LS02-WP-@@ E2A-S08LN04-WP-@@ 62 62 49 49 3 13 13 5 6 5 3 5.8 dia. (See note 1.) Indicator (See note 2.) M8x1 (See note 1.) Indicator (See note 2.) M8x1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M12LN08-WP-@@/E2A-S12LN08-WP-@ E2A-M12LS04-WP-@@/E2A-S12LS04-WP-@ 72.3 72.3 17 56 17 56 4 7 7 4 7 9.2 dia. (See note 1.) Indicator (See note 2.) M12x1 (See note 1.) Indicator (See note 2.) M12x1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M18LN16-WP-@@/E2A-S18LN16-WP-@ E2A-M18LS08-WP-@@/E2A-S18LS08-WP-@ 81.5 61 81.5 61 24 4 24 4 10 10 10 15.1 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M18x1 M18x1 Two, clamping nuts Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) E2A-M30LN30-WP-@@/E2A-S30LN30-WP-@ E2A-M30LS15-WP-@@/E2A-S30LS15-WP-@ 86.5 86.5 66 66 5 36 36 5 10 10 26.4 dia. (See note 1.) Indicator (See note 2.) (See note 1.) Indicator (See note 2.) M30x1.5 Two, clamping nuts M30x1.5 Two, clamping nuts Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section: 0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m 2. Operation indicator (yellow) Mounting Hole Cutout Dimensions External diameter of Proximity Sensor Dimension F (mm) M8 M12 F 16 +0.5 8.5 dia. 0 +0.5 0 12.5 dia. +0.5 0 M18 18.5 dia. M30 30.5 dia. +0.5 0 Inductive Sensors M12 Connector Models (Shielded) M12 Connector Models (Non-shielded) E2A-S08KN04-M1-@@ E2A-S08KS02-M1-@@ 43 43 27 3 27 3 13 5 13 M12x1 6 M12x1 5 6 dia. Indicator (See note.) Two, clamping nuts M8x1 Indicator (See note.) Two, clamping nuts M8x1 Note: Operation indicator (yellow LED, 4x90) Note: Operation indicator (yellow LED, 4x90) E2A-M12KN08-M1-@@/E2A-S12KN08-M1-@ E2A-M12KS04-M1-@@/E2A-S12KS04-M1-@ 48 48 34 17 34 7 4 M12x1 17 4 7 7 M12x1 9.4 dia. Indicator (See note.) Indicator (See note.) M12x1 M12x1 Two, clamping nuts Note 1: Note 2: Operation indicator (yellow LED, 4x90) for NO+NC (-B3 / -C3) models the total length is 4 mm longer Two, clamping nuts Note 1: Note 2: Operation indicator (yellow LED, 4x90) for NO+NC (-B3 / -C3) models the total length is 4 mm longer E2A-M18KN16-M1-@@/E2A-S18KN16-M1-@ E2A-M18KS08-M1-@@/E2A-S18KS08-M1-@ 53 53 39 10 4 24 39 4 10 24 10 M12x1 M12x1 15.3 dia. Indicator (See note.) Indicator (See note.) M18x1 M18x1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) Note: Operation indicator (yellow LED, 4x90) E2A-M30KS15-M1-@@/E2A-S30KS15-M1-@ E2A-M30KN20-M1-@@/E2A-S30KN20-M1-@ 58 58 44 44 36 5 15 36 10 5 10 M12x1 M12x1 26.6 dia. Indicator (See note.) Indicator (See note.) M30x1.5 M30x1.5 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) E2A Note: Operation indicator (yellow LED, 4x90) 17 E2A-S08LS02-M1-@@ E2A-S08LN04-M1-@@ 65 65 49 49 3 13 5 13 M12x1 M12x1 5 3 6 6 dia. Indicator (See note.) M8x1 Indicator (See note.) M8x1 Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) Note: Operation indicator (yellow LED, 4x90) 70 E2A-M12LS04-M1-@@ E2A-S12LS04-M1-@ E2A-M12LN08-M1-@@ E2A-S12LN08-M1-@ 56 4 17 7 70 56 7 17 M12x1 4 7 M12x1 9.2 dia. Indicator (See note.) Two, clamping nuts M12x1 Indicator (See note.) M12x1 Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) E2A-M18LS08-M1-@@ E2A-S18LS08-M1-@ 75 75 E2A-M18LN16-M1-@@ E2A-S18LN16-M1-@ 61 24 Note: Operation indicator (yellow LED, 4x90) 4 61 10 24 10 10 4 M12x1 M12x1 15.1 dia. Indicator (See note.) Indicator (See note.) M18x1 M18x1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) E2A-M30LS15-M1-@@ E2A-S30LS15-M1-@ 80 E2A-M30LN30-M1-@@ E2A-S30LN30-M1-@ 80 66 66 10 5 15 36 10 5 36 Note: Operation indicator (yellow LED, 4x90) M12x1 26.6 dia. Indicator (See note.) Indicator (See note.) M30x1.5 Two, clamping nuts M30x1.5 Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) Note: Operation indicator (yellow LED, 4x90) M8 Connector Models (Shielded) M8 Connector Models (Non-shielded) E2A-S08KS02-M5-@@/E2A-S08KS02-M3-@ E2A-S08KN04-M5-@@/E2A-S08KN04-M3-@ 39 39 27 27 3 13 5 6 13 M8x1 3 M8x1 5 5.8 dia. M8x1 M8x1 Two, clamping nuts Two, clamping nuts Note: Operation indicator (yellow LED, 4x90) Note: Operation indicator (yellow LED, 4x90) E2A-S08LS02-M5-@@/E2A-S08LS02-M3-@ E2A-S08LN04-M5-@@/E2A-S08LN04-M3-@ 61 61 49 49 3 13 5 M8x1 6 13 3 5 M8x1 5.8 dia. M8x1 Note: Operation indicator (yellow LED, 4x90) M8x1 Note: Operation indicator (yellow LED, 4x90) Note: Please contact your OMRON sales representative for dimension drawings not listed here. 18 Inductive Sensors Precautions Safety Precautions Wiring Power Supply Be sure to wire the E2A and load correctly, otherwise it may be damaged. Do not impose an excessive voltage on the E2A, otherwise it may be damaged. Do not impose AC current (100 to 240 VAC) on any DC model, otherwise it may be damaged. Load Short-circuit Do not short-circuit the load, or the E2A may be damaged. The E2A's short-circuit protection function will be valid if the polarity of the supply voltage imposed is correct and within the rated voltage range. Connection with No Load Be sure to insert loads when wiring. Make sure to connect a proper load to the E2A in operation, otherwise it may damage internal elements. Do not expose the product to flammable or explosive gases. Do not disassemble, repair, or modify the product. Correct Use Power OFF Designing The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Reset Time The Proximity Sensor is ready to operate within 100 ms (160ms for NO+NC -B3 / -C3 types) after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power Supply Transformer Effects of Surrounding Metal Mutual Interference When mounting the E2A within a metal panel, ensure that the clearances given in the following table are maintained. When installing two or more Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. l n m d dia. D m Type Shielded Nonshielded Dimension M8 l 0 m d D n l m d D n 4.5 --0 12 12 8 24 12 24 When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. l (Unit: mm) M30 M12 M18 Short Long barrel barrel 0 0 0 (See note 1.) (See note 2.) 12 24 45 --27 45 0 1.5 4 18 27 45 15 22 30 40 20 48 70 90 40 70 90 120 15 22 30 40 40 70 90 120 (Unit: mm) Type Dimension A B Non-shiel- A ded B Shielded M8 20 15 80 60 M12 30 20 120 100 M18 60 35 200 120 M30 Short Long barrel barrel 110 70 300 300 200 300 Note 1. In the case of using the supplied nuts. If true flash mounting is necessary, apply a free zone of 1.5 mm. 2. In the case of using the supplied nuts. If true flush mounting is necessary, apply a free zone of 4 mm. E2A 19 Wiring Maintenance and Inspection High-tension Lines Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the Sensor. Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance, but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow. Operating Environment Ensure storage and operation of the Proximity Sensor within the given specifications. M8 M12 M18 M30 Type Torque Stainless steel type 9 Nm Brass type 4 Nm 30 Nm 70 Nm 180 Nm Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with your OMRON representative at any time to confirm actual specifications of purchased product. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. D03E-EN-02A 20 In the interest of product improvement, specifications are subject to change without notice. Inductive Sensors OMRON ELECTRONICS LLC * THE AMERICAS HEADQUARTERS Schaumburg, IL USA * 847.843.7900 * 800.556.6766 * www.omron247.com OMRON CANADA, INC. * HEAD OFFICE OMRON ARGENTINA * SALES OFFICE Toronto, ON, Canada * 416.286.6465 * 866.986.6766 * www.omron247.com Cono Sur * 54.11.4783.5300 OMRON ELETRONICA DO BRASIL LTDA * HEAD OFFICE OMRON CHILE * SALES OFFICE Sao Paulo, SP, Brasil * 55.11.2101.6300 * www.omron.com.br Santiago * 56.9.9917.3920 OMRON ELECTRONICS MEXICO SA DE CV * HEAD OFFICE OTHER OMRON LATIN AMERICA SALES Apodaca, N.L. * 52.811.156.99.10 * 001.800.556.6766 * mela@omron.com 54.11.4783.5300 Cat. No. D03E-EN-02A (c) 2009 Omron Electronics LLC 05/08 Specifications are subject to change without notice. Printed in U.S.A.