80 SERIES 80 Series - Modular timers 16 A Features 80.01 80.11 Multi-function and mono-function timer range 80.01 - Multi-function & multi-voltage 80.11 - On-delay, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h * High input/output isolation * 35 mm rail (EN 60715) mount * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * New multi-voltage versions with "PWM clever" technology * * 80.01 / 80.11 Screw terminal * * Multi-voltage Multi-function * * AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on Multi-voltage Mono-function AI: On-delay FOR UL RATINGS SEE: "General technical information" page V Wiring diagram (with control signal) Wiring diagram (without control signal) For outline drawing see page 6 Wiring diagram (without control signal) Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA 1 CO (SPDT) 1 CO (SPDT) 16/30 16/30 250/400 250/400 4,000 4,000 Rated load AC15 (230 V AC) VA 750 750 Single phase motor rating (230 V AC) kW 0.55 0.55 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) AgCdO AgCdO 12...240 24...240 Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material H Supply specification Nominal voltage (UN) V AC (50/60 Hz) 12...240 24...240 Rated power AC/DC VA (50 Hz)/W < 1.8 / < 1 < 1.8 / < 1 V AC 10.8...265 16.8...265 V DC 10.8...265 16.8...265 V DC Operating range Technical data (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h I-2015, www.findernet.com Specified time range Repeatability % 1 1 Recovery time ms 100 100 Minimum control impulse ms 50 -- % 5 5 100*103 100*103 -10...+50 -10...+50 IP 20 IP 20 Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category cycles C Approvals (according to type) 1 80 SERIES 80 Series - Modular timers 16 A Features 80.21 80.41 80.91 Mono-function timer range 80.21 - Interval, multi-voltage 80.41 - Off-delay with control signal, multi-voltage 80.91 - Asymmetrical flasher, multi-voltage 17.5 mm wide Six time scales from 0.1s to 24h * High input/output isolation * 35 mm rail (EN 60715) mount * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * New multi-voltage versions with "PWM clever" technology * * * * Multi-voltage Mono-function * * Multi-voltage Mono-function BE: Off-delay with control signal DI: Interval 80.21 / 80.41 / 80.91 Screw terminal FOR UL RATINGS SEE: "General technical information" page V For outline drawing see page 6 * * Multi-voltage Mono-function LI: Asymmetrical flasher (starting pulse on) LE: Asymmetrical flasher (starting pulse on) with control signal Wiring diagram (without control signal) Wiring diagram (with control signal) Wiring diagram Wiring diagram (without control (with control signal) signal) 1 CO (SPDT) 1 CO (SPDT) 1 CO (SPDT) 16/30 16/30 16/30 250/400 250/400 250/400 4,000 4,000 4,000 Contact specification Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load AC1 VA Rated load AC15 (230 V AC) VA 750 750 750 Single phase motor rating (230 V AC) kW 0.55 0.55 0.55 16/0.3/0.12 16/0.3/0.12 16/0.3/0.12 500 (10/5) 500 (10/5) 500 (10/5) AgCdO AgCdO AgCdO 24...240 24...240 12...240 Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC (50/60 Hz) 24...240 24...240 12...240 Rated power AC/DC VA (50 Hz)/W < 1.8 / < 1 < 1.8 / < 1 < 1.8 / < 1 V AC 16.8...265 16.8...265 10.8...265 V DC 16.8...265 16.8...265 10.8...265 V DC Operating range Technical data (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h Specified time range Repeatability % 1 1 1 Recovery time ms 100 100 100 Minimum control impulse ms -- 50 50 Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category Approvals (according to type) 2 % cycles C 5 5 5 100*103 100*103 100*103 -10...+50 -10...+50 -10...+50 IP 20 IP 20 IP 20 I-2015, www.findernet.com H 80 Series - Modular Solid State timer (SST) 1 A Features 80 SERIES 80.71 Multi-function and multi-voltage solid-state output timer 17.5 mm wide Six time scales from 0.1s to 24h * High input/output isolation * 35 mm rail (EN 60715) mount * Multi-voltage output (24...240 V AC/DC), independent from the input voltage * "Blade + cross" - both flat blade and cross head screw drivers can be used to adjust the range and function selectors, the timing trimmer, and to disengage the rail mounting clip * Multi-voltage input with "PWM clever" technology * * * * Multi-voltage Multi-function AI: On-delay DI: Interval SW: Symmetrical flasher (starting pulse on) BE: Off-delay with control signal CE: On- and off-delay with control signal DE: Interval with control signal on 80.71 Screw terminal Wiring diagram (with control signal) Wiring diagram (without control signal) For outline drawing see page 6 Output circuit 1 NO (SPST-NO) Contact configuration A Rated voltage V AC/DC 24...240 Switching voltage range V AC/DC 19...265 Rated load AC15 A 1 Rated load DC1 A 1 Minimum switching current mA 0.5 Max. "OFF-state" leakage current mA 0.05 Max. "ON-state" voltage drop V H 1 Rated current 2.8 Input circuit Nominal voltage (UN) V AC (50/60 Hz) 24...240 Rated power Operating range V DC 24...240 VA (50 Hz)/W 1.3/1.3 V AC 19...265 V DC 19...265 Technical data I-2015, www.findernet.com Specified time range (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min, (0.1...2)h, (1...24)h Repeatability % 1 Recovery time ms 100 Minimum control impulse ms 50 % 5 Setting accuracy-full range Electrical life Ambient temperature range Protection category cycles C 100*106 -20...+50 IP 20 Approvals (according to type) 3 80 SERIES 80 Series - Modular timers 6 - 8 A Features 80.61 80.82 Mono-function timer range 80.61 - Power off-delay (True off-delay), multi-voltage 80.82 - Star-delta, multi-voltage 17.5 mm wide Rotary range selector, and timing trimmer * Four time scales from 0.05s to 3 min (type 80.61) * Six time scales from 0.1s to 20min (type 80.82) * High input/output isolation * 35 mm rail (EN 60715) mount * * 80.61 / 80.82 Screw terminal * * Multi-voltage Mono-function Multi-voltage Mono-function * Transfer time can be regulated (0.05...1)s * * BI: Power off-delay (True off-delay) SD: Star-delta FOR UL RATINGS SEE: "General technical information" page V For outline drawing see page 6 Wiring diagram (without control signal) Wiring diagram (without control signal) 1 CO (SPDT) 2 NO (DPST-NO) 8/15 6/10 Contact specification Contact configuration Rated current/Maximum peak current A 250/400 250/400 VA 2,000 1,500 Rated load AC15 (230 V AC) VA 400 300 Single phase motor rating (230 V AC) kW 0.3 -- 8/0.3/0.12 6/0.2/0.12 300 (5/5) 500 (12/10) AgNi AgNi 24...240 24...240 Rated voltage/Maximum switching voltage V AC Rated load AC1 Breaking capacity DC1: 30/110/220 V Minimum switching load A mW (V/mA) Standard contact material Supply specification Nominal voltage (UN) V AC (50/60 Hz) Rated power AC/DC VA (50 Hz)/W 24...220 24...240 < 0.6/ < 0.6 < 1.3/ < 0.8 V AC 16.8...265 16.8...265 V DC 16.8...242 16.8...265 (0.05...2)s, (1...16)s, (8...70)s, (50...180)s (0.1...2)s, (1...20)s, (0.1...2)min, (1...20)min V DC Operating range Technical data Specified time range Repeatability % 1 1 Recovery time ms -- 100 Minimum control impulse ms 500 (A1-A2) -- Setting accuracy-full range Electrical life at rated load in AC1 Ambient temperature range Protection category Approvals (according to type) 4 % cycles C 5 5 100*103 60*103 -10...+50 -10...+50 IP 20 IP 20 I-2015, www.findernet.com H 80 SERIES 80 Series - Modular timers 1 - 6 - 8 - 16 A Ordering information Example: 80 series, modular timers, 1 CO (SPDT) - 16 A, supply rated at (12...240)V AC/DC. 8 0 . 0 1 . 0 . 2 4 0 . 0 0 0 0 Versions 0 = Standard Series Type 0 = Multi-function (AI, DI, SW, BE, CE, DE) 1 = On-delay (AI) 2 = Interval (DI) 4 = Off-delay with control signal (BE) 6 = Power off-delay (True off-delay) (BI) 7 = Multi-function with solid state output (AI, DI, SW, BE, CE, DE) 8 = Star-delta (SD) 9 = Asymmetrical flasher (LI, LE) Supply voltage 240 = (12 ... 240)V AC/DC (80.01, 80.91) 240 = (24 ... 240)V AC/DC (80.11, 80.21, 80.41, 80.71, 80.82) 240 = (24...240)V AC, (24...220)V DC (80.61) Supply version 0 = AC (50/60 Hz)/DC No. of poles 1 = 1 CO (SPDT) 1 = 1 NO (SPST-NO), type 80.71 only 2 = 2 NO (DPST-NO), type 80.82 only Technical data Insulation 80.61 80.71 between input and output circuit V AC 4,000 80.01/11/21/41/82/91 2,500 2,500 between open contacts V AC 1,000 1,000 -- 4 4 Dielectric strength Insulation (1.2/50 s) between input and output kV 6 EMC specifications Type of test Reference standard Electrostatic discharge contact discharge EN 61000-4-2 4 kV air discharge EN 61000-4-2 8 kV Radio-frequency electromagnetic field (80 / 1,000 MHz) EN 61000-4-3 Fast transients (burst) (5-50 ns, 5 kHz) on Supply terminals EN 61000-4-4 4 kV Surges (1.2/50 s) on Supply terminals common mode EN 61000-4-5 4 kV differential mode EN 61000-4-5 4 kV common mode EN 61000-4-5 4 kV differential mode on start terminal (B1) 10 V/m EN 61000-4-5 4 kV Radio-frequency common mode (0.15 / 80 MHz) on Supply terminals EN 61000-4-6 10 V Radiated and conducted emission EN 55022 class A H Other data Current absorption on signal control (B1) Power lost to the environment Screw torque Max. wire size < 1 mA without contact current W 1.4 with rated current W 3.2 Nm 0.8 solid cable stranded cable mm2 1x6 / 2x4 1x4 / 2x2.5 AWG 1x10 / 2x12 1x12 / 2x14 Accessories I-2015, www.findernet.com Sheet of marker tags, for types 80.82, plastic, 24 tags, 9x17 mm 020.24 020.24 Sheet of marker tags, for types 80.01/11/21/41/61/71, plastic, 72 tags, 6x12 mm 060.72 060.72 5 80 SERIES 80 Series - Modular timers 1 - 6 - 8 - 16 A Outline drawings 80.01 Screw terminal 80.11 Screw terminal 80.21 Screw terminal 80.41 Screw terminal 80.91 Screw terminal 80.71 Screw terminal 80.61 Screw terminal 80.82 Screw terminal I-2015, www.findernet.com H 6 80 SERIES 80 Series - Modular timers 1 - 6 - 8 - 16 A Functions U = Supply voltage LED* Supply voltage NO output contact OFF Closed Open 15 - 18 15 - 16 ON Open 15 - 18 15 - 16 ON Open (Timing in Progress) 15 - 18 15 - 16 ON Closed 15 - 16 15 - 18 S = Signal switch = Output contact Contacts Open * The LED on type 80.61 is illuminated only when the supply voltage is applied to the timer; during the timing period the LED is not illuminated. Without control signal = Start via contact in supply line (A1). With control signal = Start via contact into control terminal (B1). Wiring diagram Without control signal Type 80.01 80.71 (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 80.01 (SW) Symmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ratio is 1:1 (time on = time off). 80.71 With control signal 80.01 80.71 80.01 80.71 (BE) Off-delay with control signal. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. H (CE) On- and off-delay with control signal. Power is permenently applied to the timer. Closing the Signal Switch (S) initiates the preset delay, after which time the output contacts transfer. Opening the Signal switch initiates the same preset delay, after which time the output contacts reset. (DE) Interval with control signal on. Power is permenently applied to the timer. On momentary or maintained closure of Signal Switch (S), the output contacts transfer, and remain so for the duration of the preset delay, after which they reset. NOTE: The function must be set before energising the timer. * Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. I-2015, www.findernet.com * With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1). ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12 V DC 7 80 SERIES 80 Series - Modular timers 6 - 8 - 16 A Functions Wiring diagram Without control signal 80.11/21/61 Type 80.11 (AI) On-delay. Apply power to timer. Output contacts transfer after preset time has elapsed. Reset occurs when power is removed. 80.21 (DI) Interval. Apply power to timer. Output contacts transfer immediately. After the preset time has elapsed, contacts reset. 80.61 (BI) Power off-delay (True off-delay). Apply power to timer (minimum 500ms). Output contacts transfer immediately. Removal of power initiates the preset delay, after which time the output contacts reset. 80.82 (SD) Star-delta. Apply power to timer. The star contact ( ) closes immediately. After preset delay has elapsed the star contact ( ) resets. After a further transfer time variable from (0.05...1)s the delta contact ( ) closes and remains in that position, until reset on power off. 80.41 (BE) Off-delay with control signal. Power is permenently applied to the timer. The output contacts transfer immediately on closure of the Signal Switch (S). Opening the Signal Switch initiates the preset delay, after which time the output contacts reset. 80.91 (LI) Asymmetrical flasher (starting pulse on). Apply power to timer. Output contacts transfer immediately and cycle between ON and OFF for as long as power is applied. The ON (T1) and OFF (T2) times are independently adjustable. 80.82 With control signal 80.41 Without control signal H 80.91 With control signal (LE) Asymmetrical flasher (starting pulse on) with control signal Power is permenently applied to the timer. Closing Signal Switch (S) causes the output contacts to transfer immediately and cycle between ON (T1) and OFF (T2), until opened. 80.91 * Possible to control an external load, such as another relay coil or timer, connected to the control signal terminal B1. ** A voltage other than the supply voltage can be applied to the command Start (B1), example: A1 - A2 = 230 V AC B1 - A2 = 12 V DC 8 I-2015, www.findernet.com * With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).