October 2012
© 2012 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
VT02
Visual IR Thermometer
Users Manual
LIMITED WARRANTY AND LIMITATION OF LIABILITY
This Fluke product will be free from defects in material and workmanship for
two years from the date of purchase. This warranty does not cover fuses,
disposable batteries, or damage from accident, neglect, misuse, alteration,
contamination, or abnormal conditions of operation or handling. Resellers are
not authorized to extend any other warranty on Fluke’s behalf. To obtain
service during the warranty period, contact your nearest Fluke authorized
service center to obtain return authorization information, then send the product
to that Service Center with a description of the problem.
THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES,
SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR
IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING
FROM ANY CAUSE OR THEORY. Since some states or countries do not allow
the exclusion or limitation of an implied warranty or of incidental or
consequential damages, this limitation of liability may not apply to you.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99
i
Table of Contents
Title Page
Introduction ............................................................................... 1
How to Contact Fluke ................................................................ 2
Safety Information ..................................................................... 2
Before You Start ........................................................................ 4
Power On and Off ...................................................................... 5
Features and Controls ................................................................ 6
Focus ...................................................................................... 7
Button Operations .................................................................. 7
Image Blending .................................................................. 7
Capture and Save ................................................................ 7
Menu Functions ......................................................................... 9
Basic Navigation .................................................................... 9
Review Memory ..................................................................... 11
Emissivity ............................................................................... 11
Temperature Measurement ..................................................... 11
Color Palette ........................................................................... 12
Reflected Background Temperature ....................................... 13
Spot Temperature Markers ..................................................... 13
Temperature Units .................................................................. 13
Date and Time ........................................................................ 13
Measurements ............................................................................ 15
Smartview® Software ................................................................. 15
Maintenance ............................................................................... 16
How to Clean the Case ........................................................... 16
Battery Care ........................................................................... 16
Specifications ............................................................................. 18
VT02
Users Manual
ii
iii
List of Tables
Table Title Page
1. Symbols ..................................................................................... 3
2. Packing List ............................................................................... 4
3. Features ...................................................................................... 6
4. Menu Icons ................................................................................ 10
VT02
Users Manual
iv
v
List of Figures
Figure Title Page
1. Start-Up Screen and Power Indicator ........................................ 5
2. Blend Options ............................................................................ 7
3. SD Card Warning Icons ............................................................. 8
4. Menu Navigation and Battery Icon ............................................ 9
5. Parameter Adjustment ............................................................... 10
6. Battery Replacement .................................................................. 17
VT02
Users Manual
vi
1
Introduction
The VT02 (the Product) is a Visual IR Thermometer that combines surface
temperature measurement together with a real-time thermal image.
The thermal image removes the time necessary for component-by-component
measurement associated with traditional spot radiometers. Potential issues are
clearly shown on the color LCD display to help the user quickly and accurately
position the center-point measurement cursor and measure the temperature.
To aid identification, the Product includes a visual camera. Images can be
blended from full thermal to full visual as necessary. Both thermal and visual
images can be saved to the removable memory card. Images can be recalled or
saved to a PC for report generation and to print.
The VT02 is easy to use. Turn on and within seconds it is ready to test. The
Product is ideal for electricians and maintenance technicians and can be used
to find areas of concern quickly.
Several features increase the accuracy and usability of the Product:
Adjustable emissivity and reflected background compensation
improves measurement accuracy on semi-reflective surfaces
Hot and cold spot temperature markers that guide the user to the
hottest and coldest regions in the thermal image
Selectable color palettes
Visual IR Thermometer
How to Contact Fluke
2
How to Contact Fluke
To contact Fluke, use one of these telephone numbers:
USA: 1-800-760-4523
Canada: 1-800-36-FLUKE (1-800-363-5853)
Europe: +31 402-675-200
Japan: +81-3-6714-3114
Singapore: +65-6799-5566
Anywhere in the world: +1-425-446-5500
Or, visit Fluke's website at www.fluke.com.
To register your Product, visit http://register.fluke.com.
To view, print, or download the latest manual supplement, visit
http://us.fluke.com/usen/support/manuals.
Safety Information
A Warning identifies hazardous conditions and procedures that are dangerous
to the user. A Caution identifies conditions and procedures that can cause
damage to the Product or the equipment under test.
XW Warning
To prevent possible electrical shock, fire, or personal injury:
Read all safety information before you use the Product.
Carefully read all instructions.
Use the Product only as specified, or the protection
supplied by the Product can be compromised.
Replace the batteries when the low battery indicator
shows to prevent incorrect measurements.
Do not use the Product around explosive gas, vapor, or
in damp or wet environments.
Do not use the Product if it operates incorrectly.
Do not use and disable the Product if it is damaged.
See emissivity information for actual temperatures.
Reflective objects result in lower than actual temperature
measurements. These objects pose a burn hazard.
VT02
Users Manual
3
Remove the batteries if the Product is not used for an
extended period of time, or if stored in temperatures
above 50 °C. If the batteries are not removed, battery
leakage can damage the Product.
Table 1 is a list of symbols used on the Product or in this manual.
Table 1. Symbols
Symbol Description
W Important information. See manual.
X Hazardous voltage. Risk of electrical shock.
; Conforms to relevant Australian standards.
P Conforms to requirements of European Union and European
Free Trade Association.
à Conforms to relevant South Korean EMC standards.
~
This product complies with the WEEE Directive (2002/96/EC)
marking requirements. The affixed label indicates that you must
not discard this electrical/electronic product in domestic
household waste. Product Category: With reference to the
equipment types in the WEEE Directive Annex I, this product is
classed as category 9 “Monitoring and Control Instrumentation”
product. Do not dispose of this product as unsorted municipal
waste. Go to Fluke's website for recycling information.
Visual IR Thermometer
Before You Start
4
Before You Start
Table 2 is a list of all items included with the Product.
Table 2. Packing List
Item Description Part Number
1 Visual IR Thermometer 4253599
2 AA Alkaline Batteries (QTY. 4) 1560231
3 Micro SD Memory Card and conversion adapter to
standard SD Memory Card[1]
4269849
4 Transport/Storage Case 4272528
5 Quick Reference Card
(printed in English, Spanish, French, German, and
Simplified Chinese[2])
4257700
6 CD-ROM with Users Manual 4253607
7 SmartView® Software on CD-ROM 2814474
[1] Fluke recommends the SD memory card that is supplied with the Product. Fluke
does not warrant the use or reliability of aftermarket SD memory cards of different
brands or capacities.
[2] See the CD-ROM for additional languages. To request a printed Quick Reference
Card in a language not supplied with your product, email Fluke at
TPubs@fluke.com. Specify the product name and language preference in the
subject line.
VT02
Users Manual
5
Power On and Off
To turn on the Product, push and hold E for 2 seconds. A start-up screen
shows on the display and an indicator bar shows the status, see Figure 1. The
indication bar increases on power up and decreases on power down. After the
start-up screen, the Product is ready to use. To turn off the Product, push and
hold E for 2 seconds.
The Auto Off feature turns off the Product after 10 minutes of inactivity.
hak03.eps
Figure 1. Start-Up Screen and Power Indicator
Note
All visual IR thermometers need sufficient warm-up time for the most
accurate temperature measurements and best image quality. This time
can often vary by model and by environmental conditions. Although
most visual IR thermometers are fully warmed up in 3 to 5 minutes, it
is always best to wait a minimum of 10 minutes if the most accurate
temperature measurement is very important to your application.
When you move a visual IR thermometer between environments with
large differences in ambient temperature, more adjustment time can
be required.
For the first time use, or when the batteries are removed for more than a few
hours, the Date and Time menu opens. See page 13 for more information about
how to set the date and time.
Visual IR Thermometer
Features and Controls
6
Features and Controls
Table 3 is a list of the Product features with the location of each control.
Table 3. Features
3
6
2
4
5
1
7
9
10
11
8
hak04.e
p
s
Item Description
A LCD Display
B Power On/Off and Menu
C SD Memory Card Slot
D Lanyard
E Tripod Mount
F Menu Selection/Parameter Adjustment
G Infrared Lens
H Rotating Lens Cover
I Visual Camera
J Trigger for Image Capture
K Battery Cover
VT02
Users Manual
7
Focus
The Product is a fixed focus visual IR thermometer that operates from 50 cm
(20 in).
Button Operations
Two functions are accessed directly from the buttons: Blending/Capture and
Save. The arrow buttons are used for menu navigation.
Image Blending
Image blending makes it easier to understand infrared images through the use
of an aligned visible image and infrared image. The Product captures a visible
image with each infrared image to exactly show the target area and more
effectively share it with others.
To use the blending function:
1. Push E until shows in the bottom left-hand corner of the screen.
2. Use D/C to adjust the blending from 0 % to 100 %.
The blend options are shown in Figure 2.
0 % 25 % 50 % 100 %75 %
hak01.eps
Figure 2. Blend Options
Capture and Save
The Product saves up to 10,000 images on the Micro SD card.
To capture the image and save it to memory:
1. Push E until shows in the bottom right-hand corner of the
screen.
2. Point the Product at the object or area of interest.
3. Pull the trigger to capture the image.
Visual IR Thermometer
Features and Controls
8
The image remains frozen for about 4 seconds. It then shows the
dialog box to let you either save or discard the image.
4. Push F to save or E to discard the image.
The display has an icon that shows the current status of the SD card, see
Figure 3.
1 2 34
hak02.eps
Figure 3. SD Card Warning Icons
A No SD card in slot
B SD card error
C SD card empty
D SD card full
Note
A routine file back-up procedure is recommended for the SD card to
store these files in a safe location.
VT02
Users Manual
9
Menu Functions
To open the display menu, push E. The menu has options for memory,
emissivity, background temperature, spot temperature markers, date, and time.
Basic Navigation
The basic functions of the Product are accessible with the six buttons and color
display. Only five options show on the display at one time. The D/C buttons
scroll through the display menu. The middle option is always highlighted in
yellow. See Figure 4.
5:12
˚C
20˚C
0
Yellow Highlight
Open Display Menu Select/Enter
Up/Down to
Change Values
Battery Charge Level
hak07.eps
Figure 4. Menu Navigation and Battery Icon
Push F to select the menu option and edit the value. The D/C buttons
change the value of the menu selection. After adjustments are made, push F
to accept a new value and exit the edit mode. See Figure 5.
Visual IR Thermometer
Menu Functions
10
D/C to highlight
to select (color inverts)
F
D/C change values
F
accept new value
hak08.eps
Figure 5. Parameter Adjustment
Table 4 is a list of the menu icons and their descriptions.
Table 4. Menu Icons
Icon Description
Play Stored images,
see Review Memory
on page 11
Emissivity, see page 11
Color Palette, see page 12
Background Temperature, see
Reflected Background Temperature
on page 13
Temperature Markers, see Spot
Temperature Markers on page 13
Temperature Units,
see page 13
Clock, see Time and Date
on page 13
VT02
Users Manual
11
Review Memory
The Memory mode lets you view the stored images. You can also delete
images in this menu.
1. Push F to open the Memory mode.
2. Push D/C to scroll through and review the stored images.
3. Push F to delete image.
Emissivity
The emissivity is adjustable in 0.01 steps from 0.10 to 01.00. The default value
is set at 0.95.
The correct emissivity values are important for you to make the most accurate
temperature measurements. Emissivity of a surface can have a large effect on
the apparent temperatures that the Product observes. Understanding the
emissivity of the inspection surface can, but not always, allow you to obtain
more accurate temperature measurements.
Temperature Measurement
All objects radiate infrared energy. The quantity of energy radiated is based on
the actual surface temperature and the surface emissivity of the object. The
Product senses the infrared energy from the surface of the object and uses this
data to calculate an estimated temperature value. Many common objects and
materials such as painted metal, wood, water, skin, and cloth are very good at
radiating energy and it is easy to get relatively accurate measurements. For
surfaces that are good at radiating energy (high emissivity), the emissivity
factor is 90 % (0.90). This simplification does not work on shiny surfaces or
unpainted metals as they have an emissivity of <60 % (0.60). These materials
are not good at radiating energy and are classified as low emissivity. To more
accurately measure materials with a low emissivity, an emissivity correction is
necessary. Adjustment to the emissivity value will usually allow the Product to
calculate a more accurate estimate of the actual temperature.
Visual IR Thermometer
Menu Functions
12
Note
Surfaces with an emissivity <0.60 make reliable and consistent
determination of actual temperatures problematic. The lower the
emissivity, the more potential error is associated with the temperature
measurement calculations of the Product, even when emissivity and
reflected background adjustments are attempted and performed
properly.
W Warning
To prevent personal injury, see emissivity information for actual
temperatures. Reflective objects result in lower than actual
temperature measurements. These objects pose a burn hazard.
Go to http://www.fluke.com/Fluke-Thermal-Imaging-and-Thermal-Imagers for
more information on emissivity and how to get the most accurate temperature
measurements.
Color Palette
The Palette menu changes the false-color presentation of the infrared images
that are on the display or captured. A variety of palettes are available. Some
palettes are more suitable for specific applications and are set as required.
Grayscale Palettes offer an equal, linear presentation of colors that allow for
best presentation of detail.
The High Contrast palette offers a weighted presentation of colors. This palette
is best in situations with high thermal contrast for increased color contrast
between the high temperatures and low temperatures.
The Ironbow and Rainbow palettes offer a mixture of the High Contrast and
Grayscale palettes.
Grayscale (White hot)
Grayscale (Black hot)
High Contrast
Ironbow
Rainbow
VT02
Users Manual
13
Reflected Background Temperature
The background temperature can be set between 0 °C and +36 °C.
Compensation for reflected background temperature is set in the Background
tab. Very hot objects or very cold objects can affect the apparent temperature
and measurement accuracy of the target or object of interest, especially when
surface emissivity is low. Adjustment of the reflected background temperature
can make the temperature measurement better in many situations. For more
information, see Emissivity on page 11.
Spot Temperature Markers
The spot temperature markers turn on and off. When turned on, the marker is
an indication of a hot or cold spot in the scene that may require additional
evaluation. When turned off, the user is able to concentrate on the single
measurement pixel.
Temperature Units
The Product displays temperatures in °C or °F.
Date and Time
In the Clock menu the user can set the time and the date.
Push F to select the Clock.
hak12.jpg
Visual IR Thermometer
Menu Functions
14
1. Push F again to select the date type. Move through the menu
selections with the D/C buttons.
Selections are:
DD/MM/YYYY
MM/DD/YYYY
2. Move down to the date.
3. Use A/B buttons to select each date item. Use D/C to change the
value.
4. Push F to set the value.
5. Move down to 12/24 hour clock. Push F to edit the option.
6. Use the D/C to move through the selections.
7. Push F to set the selection as:
12 hr
24 hr
8. Move down to time.
9. Push F to edit the option.
10. Use A/B to move through individual time items.
11. Use D/C to change the value.
12. Push F to set the value.
13. Push E to exit the Clock menu and go to the live image.
VT02
Users Manual
15
Measurements
The temperature measurement of the center pixel is shown at the top of the
display. The emissivity setting also shows at the top of the display. When the
hot/cold temperature markers are turned on, move the Product until the hot or
cold spot coincides with the middle measurement pixel. Point the Product at an
object that is likely to be hotter or colder than its surroundings for best results.
The value of the hot/cold point shows at the top of the screen.
hak13.jpg
Smartview® Software
Smartview® software is supplied with the Product. This software contains
features to analyze images, organize data and information, and make
professional reports.
Smartview includes a function to export IR and visible images as .is2 files.
Visual IR Thermometer
Maintenance
16
Maintenance
Maintenance is not necessary for this Product.
XW Warning
To prevent possible electrical shock, fire, or personal injury, use
only specified replacement parts.
How to Clean the Case
Clean the case with a damp cloth and a weak soap solution. Do not use
abrasives, isopropyl alcohol, or solvents to clean the case or lens/window.
Battery Care
W Warning
To prevent personal injury and for safe operation and
maintenance of the Product:
Batteries contain hazardous chemicals that can cause burns
or explode. If exposure to chemicals occurs, clean with water
and get medical aid.
Be sure that the battery polarity is correct to prevent battery
leakage.
Do not short the battery terminals together.
Keep cells and battery packs clean and dry. Clean dirty
connectors with a dry, clean cloth.
Do not disassemble or crush battery cells and battery packs.
Do not put battery cells and battery packs near heat or fire.
Do not put in sunlight.
~ W Caution
Do not incinerate the Product and/or battery. Go to Fluke’s
website for recycling information.
To replace the batteries:
1. Remove the battery cover from the handle.
2. Remove the discharged batteries.
Note
Do not charge the batteries included with the Product.
3. Install new batteries with the correct polarity, see Figure 6.
VT02
Users Manual
17
1
2
hak06.eps
Figure 6. Battery Replacement
4. Slide battery cover into place on the handle.
Visual IR Thermometer
Specifications
18
Specifications
Temperature
Temperature Measurement Range ..................... -10 °C to +250 °C
Temperature Measurement Accuracy ................. ±2 °C or ±2 % of reading in °C,
whichever is the greater (at 23°
nominal)
On-Screen Emissivity Correction ........................ Yes
On-Screen Reflected Background
Temperature Compensation ................................ Yes
Image Performance
Image Capture Frequency ................................... 8 Hz
Detector Type ...................................................... Uncooled pyroelectric ceramic
Thermal Sensitivity (NETD) ................................. 250 mK
Infrared Spectral Band ........................................ 8 µm to 14 µm
Visual Camera ..................................................... 11025 pixels
Minimum Focus Distance .................................... 50 cm
Field of View ........................................................ 20° X 20°
Focus Mechanism ............................................... Fixed Focus
Image Presentation
Palettes ............................................................... Ironbow, Rainbow, Rainbow High
Contrast, Grayscale (white hot) and
Grayscale (black hot)
Level and Span ................................................... Auto
Blending Information
Parallax Correction of Visual and IR Blending .... Fixed
View Options ....................................................... Blending of the visual and the infrared
from full infrared to full visual in
25 % steps
Hot Spot and Cold Spot Tracking ........................ Yes
Image capture and data storage
Image Capture ..................................................... Image available for review before a
save
Storage Medium .................................................. Micro SD card, stores up to 10,000
images
File Format .......................................................... .is2
Memory Review ................................................... Scroll through all saved images and
view on-screen
Operating Temperature ......................................... -5 °C to +45 °C
Storage Temperature ............................................ -20 °C to +60 °C
Relative Humidity .................................................. 10 % to 90 % non-condensing
VT02
Users Manual
19
Display ................................................................... 2.2 in diagonal
Controls and Adjustments
Select Color Palette
User-Selectable Temperature Scale (°F/°C)
Time/Date Set
Emissivity Selection
Reflected Background Temperature Compensation
Software ................................................................. Smartview®
Note
Smartview® software is available for reports.
Batteries ................................................................ 4 AA
Battery Life .......................................................... 8 hrs
Power Save ........................................................ Power down after 10 minutes of
inactivity
Safety Standards
EMC .................................................................... EN 61326-1:2006
US FCC (optional) .................................. CFR47: 2009 Class A. Part 15
subpart B.
Applies to use in Korea only ................... Class A Equipment (Industrial
Broadcasting & Communication
Equipment)[1]
[1] This product meets requirements for
industrial (Class A) electromagnetic wave
equipment and the seller or user should
take notice of it. This equipment is intended
for use in business environments and is not
to be used in homes.
Safety Compliance ............................................. IEC/EN 61010-1:2010
Drop ....................................................................... MIL-PRF-28800F;
Class 2 section 4.5.5.4.2; 30 cm
Size (H x W x L) ..................................................... 21 cm x 7.5 cm x 5.5 cm
(8.3 in x 3 in x 2.2 in)
Weight (Battery Included) .................................... <300 gm (10.5 oz)
Warranty ................................................................ 2 years
Recommended Calibration Cycle ........................ 2 years
Visual IR Thermometer
Specifications
20