FEATURES High efficiency: 89% @ 5V/ 15A Size: 58.4mm x 22.8mm x 9.2mm (2.30"x0.90"x0.36") ( W/O heat-spreader ) 58.4mm x 22.8mm x 12.7mm (2.30"x0.90"x0.5") ( With heat-spreader ) Industry standard pin out 18~75V extremely wide 4:1 input range Fixed frequency operation Input UVLO, Output OCP, OVP and OTP 2250V isolation Basic insulation No minimum load required SMD and through-hole versions ISO 9001, TL 9000, ISO 14001, QS 9000, OHSAS 18001 certified manufacturing facility UL/cUL 60950-1 (US & Canada) Recognized Delphi Series E36SR, 75W Eighth Brick Family 18~75V in, 5V/15A out The Delphi Series E36SR Eighth Brick, 18~75V input, single output, isolated DC/DC converter is the latest offering from a world leader in OPTIONS Positive On/Off logic Short pin lengths available This product family operates from an extremely wide 18~75V input range SMD pin and provides up to 75 watts of power in an industry standard eighth brick Heat spreader power systems technology and manufacturing -- Delta Electronics, Inc. footprint and pinout. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performances, as well as extremely high reliability under highly stressful operating conditions. All models are fully protected from abnormal input/output voltage, current, and temperature conditions. The APPLICATIONS Delphi Series converters meet all safety requirements with basic Telecom / Datacom Wireless Networks Optical Network Equipment Server and Data Storage Industrial / Testing Equipment insulation. DATASHEET DS_E36SR05015_10292013 TECHNICAL SPECIFICATIONS (TA=25C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted.) PARAMETER ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Transient (100ms) Operating Ambient Temperature Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off Converter Input Current 2 Inrush Current(I t) Input Reflected-Ripple Current Input Voltage Ripple Rejection OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Load Over Line Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output DC Current-Limit Inception DYNAMIC CHARACTERISTICS Output Voltage Current Transient Positive Step Change in Output Current Negative Step Change in Output Current Settling Time (within 1% Vout nominal) Turn-On Transient Start-Up Time, From On/Off Control Start-Up Time, From Input Maximum Output Capacitance EFFICIENCY 100% Load 60% Load ISOLATION CHARACTERISTICS Input to Output Isolation Resistance Isolation Capacitance FEATURE CHARACTERISTICS Switching Frequency ON/OFF Control, Negative Remote On/Off logic Logic Low (Module On) Logic High (Module Off) ON/OFF Control, Positive Remote On/Off logic Logic Low (Module Off) Logic High (Module On) ON/OFF Current (for both remote on/off logic) Leakage Current (for both remote on/off logic) Output Voltage Trim Range Output Voltage Remote Sense Range Output Over-Voltage Protection GENERAL SPECIFICATIONS MTBF Weight Weight Over-Temperature Shutdown DS_E36SR05015_10292013 NOTES and CONDITIONS E36SR05015 (Standard) Min. Typ. Max. Units 18 24/48 75 100 85 125 2250 Vdc Vdc C C Vdc 18 24/48 75 Vdc 18 16.5 18.5 17 1.5 19 17.5 3 5 Vdc Vdc Vdc A mA mA 2 As mA dB 100ms -40 -55 100% Load, 18Vin No load, 48Vin 70 10 P-P thru 12H inductor, 5Hz to 20MHz 120 Hz Vin=48V, Io=Io.max, Tc=25C Io=Io,min to Io,max Vin=18V to 75V Tc=-40C to 85C over sample load, line and temperature 5Hz to 20MHz bandwidth Full Load, 1F ceramic, 10F tantalum Full Load, 1F ceramic, 10F tantalum Output Voltage 10% Low 15 1 20 60 4.95 5.0 5.05 Vdc 5 5 25 10 10 50 5.1 mV mV mV V 40 15 140 mV mV A % 4.9 60 10 0 110 48V, 10F Tan & 1F Ceramic load cap, 0.1A/s 25% Io.max to 50% Io.max 50% Io.max to 25% Io.max 150 150 200 2 10 Full load; 5% overshoot of Vout at startup mV mV us 20 20 5000 89 90 % % 2250 1500 Vdc M pF 300 kHz 10 Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 A Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 A Ion/off at Von/off=0.0V Logic High, Von/off=15V Across Pins 9 & 5, Pout max rated power Pout max rated power Over full temp range; % of nominal Vout Io=80% of Io, max; 300LFM @25 Without heat spreader With heat spreader Refer to Figure 21 for measuring point ms ms F 0 2.4 1.8 18 V V 0 2.4 1.8 18 1 50 10% 10 6 V V mA uA % % V 2.2 25 36.5 127 M hours grams grams C -10% 2 ELECTRICAL CHARACTERISTICS CURVES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at 25C. Figure 2: Power dissipation vs. load current for minimum, nominal, and maximum input voltage at 25C. Figure 3: Typical full load input characteristics at room temperature. DS_E36SR05015_10292013 3 ELECTRICAL CHARACTERISTICS CURVES Figure 4: Turn-on transient at full rated load current (CC mode) (5ms/div). Vin=48V.Top Trace: Vout, 2V/div; Bottom Trace: ON/OFF input, 5V/div. Figure 5: Turn-on transient at zero load current (5ms/div). Vin=48V.Top Trace: Vout, 2V/div; Bottom Trace: ON/OFF input, 5V/div. Figure 6: Turn-on transient at full rated load current (CC mode) (5ms/div). Vin=48V.Top Trace: Vout, 2V/div; Bottom Trace: input voltage, 20V/div. Figure 7: Turn-on transient at zero load current (5ms/div). Vin=48V.Top Trace: Vout, 2V/div; Bottom Trace: input voltage, 20V/div. DS_E36SR05015_10292013 4 ELECTRICAL CHARACTERISTICS CURVES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/s). Load cap: 10F, tantalum capacitor and 1F ceramic capacitor. Top Trace: Vout (100mV/div, 200us/div), Bottom Trace: I out (5A/div). Figure 9: Output voltage response to step-change in load current (25%-50% of Io, max; di/dt = 0.1A/s). Load cap: 10F, tantalum capacitor and 1F ceramic capacitor. Top Trace: Vout (100mV/div, 200us/div), Bottom Trace: I out (5A/div). Figure 10: Test set-up diagram showing measurement points for Input Terminal Ripple Current and Input Reflected Ripple Current. Figure 11: Input Terminal Ripple Current, ic, at 48Vin and 15A output current with 12H source impedance and 33F electrolytic capacitor (500 mA/div, 2us/div). DS_E36SR05015_10292013 5 ELECTRICAL CHARACTERISTICS CURVES Copper Strip Vo(+) 10u 1u SCOPE RESISTIVE LOAD Vo(-) Figure 12: Input reflected ripple current, is, through a 12H source inductor at 48Vin and 15A output current (20 mA/div, 2us/div). Figure 13: Output voltage noise and ripple measurement test setup. Figure 14: Output voltage ripple at 48Vin and rated load current (Io=15A)(20 mV/div, 2us/div) Load capacitance: 1F ceramic capacitor and 10F tantalum capacitor. Bandwidth: 20 MHz. Figure 15: Output voltage vs. load current showing typical current limit curves and converter shutdown points. DS_E36SR05015_10292013 6 DESIGN CONSIDERATIONS Input Source Impedance The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few H, we advise adding a 10 to 100 F electrolytic capacitor (ESR < 0.7 at 100 kHz) mounted close to the input of the module to improve the stability. Layout and EMC Considerations Delta's DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta's technical support team. An external input filter module is available for easier EMC compliance design. Application notes to assist designers in addressing these issues are pending release. Safety Considerations The power module must be installed in compliance with the spacing and separation requirements of the end-user's safety agency standard, i.e., UL60950, CAN/CSA-C22.2 No. 60950-00 and EN60950: 2000 and IEC60950-1999, if the system in which the power module is to be used must meet safety agency requirements. Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV. When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc, for the module's output to meet SELV requirements, all of the following must be met: DS_E36SR05015_10292013 The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded, one Vi pin and one Vo pin shall also be grounded. A SELV reliability test is conducted on the system where the module is used, in combination with the module, to ensure that under a single fault, hazardous voltage does not appear at the module's output. When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a normal-blow fuse with 10A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current. Soldering and Cleaning Considerations Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta's technical support team. 7 FEATURES DESCRIPTIONS Vi(+) Vo(+) Over-Current Protection Sense(+) The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will automatically shut down (hiccup mode). The modules will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected. Over-Voltage Protection The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. If this voltage exceeds the over-voltage set point, the module will shut down and latch off. The over-voltage latch is reset by either cycling the input power or by toggling the on/off signal for one second. Over-Temperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the over-temperature threshold the module will shut down. ON/OFF Sense(-) Vi(-) Figure 16: Remote on/off implementation Remote Sense Remote sense compensates for voltage drops on the output by sensing the actual output voltage at the point of load. The voltage between the remote sense pins and the output terminals must not exceed the output voltage sense range given here: [Vo(+) - Vo(-)] - [SENSE(+) - SENSE(-)] 10% x Vout This limit includes any increase in voltage due to remote sense compensation and output voltage set point adjustment (trim). Vi(+) Sense(-) Vi(-) The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low. Remote on/off can be controlled by an external switch between the on/off terminal and the Vi(-) terminal. The switch can be an open collector or open drain. For negative logic if the remote on/off feature is not used, please short the on/off pin to Vi(-). For positive logic if the remote on/off feature is not used, please leave the on/off pin to floating. Vo(+) Sense(+) The module will try to restart after shutdown. If the over-temperature condition still exists during restart, the module will shut down again. This restart trial will continue until the temperature is within specification. Remote On/Off Vo(-) Contact Resistance Vo(-) Contact and Distribution Losses Figure 17: Effective circuit configuration for remote sense operation If the remote sense feature is not used to regulate the output at the point of load, please connect SENSE(+) to Vo(+) and SENSE(-) to Vo(-) at the module. The output voltage can be increased by both the remote sense and the trim; however, the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power does not exceed the maximum rated power. DS_E36SR05015_10292013 8 FEATURES DESCRIPTIONS (CON.) Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, the modules may be connected with an external resistor between the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used. Figure 19: Circuit configuration for trim-up (increase output voltage) Figure 18: Circuit configuration for trim-down (decrease output voltage) If the external resistor is connected between the TRIM and SENSE (-) pins, the output voltage set point decreases (Fig. 18). The external resistor value required to obtain a percentage of output voltage change % is defined as: Rtrim down 511 10.2K Ex. When Trim-down -10%(5Vx0.9=4.5V) Rtrim down 511 10.2 40.9K 10 If the external resistor is connected between the TRIM and SENSE (+) the output voltage set point increases (Fig. 19). The external resistor value required to obtain a percentage output voltage change % is defined as: Rtrim up 5.11Vo (100 ) 511 10.2K 1.225 Ex. When Trim-up +10%(5Vx1.1=5.5V) Rtrim up 5.11 5 (100 10 ) 511 10.2 168K 1.225 10 10 The output voltage can be increased by both the remote sense and the trim, however the maximum increase is the larger of either the remote sense or the trim, not the sum of both. When using remote sense and trim, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. DS_E36SR05015_10292013 9 THERMAL CONSIDERATIONS Thermal Derating Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Heat can be removed by increasing airflow over the module. The hottest point temperature of the module is +122C. To enhance system reliability; the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. THERMAL CURVES Thermal Testing Setup Delta's DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25''). Figure 21: Hot spot temperature measured point. The allowed maximum hot spot temperature is defined at 122 Output Current(A) 16 E36SR05015(Standard) Output Current vs. Ambient Temperature and Air Velocity @Vin = 24V (Transverse Orientation) 14 12 Natural Convection PWB FANCING PWB 100LFM 10 200LFM 300LFM MODULE 8 400LFM 6 500LFM 600LFM 4 2 50.8(2.00") AIR VELOCITY AND AMBIENT TEMPERATURE SURED BELOW THE MODULE AIR FLOW 0 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature () Figure 22: Output current vs. ambient temperature and air velocity @ Vin=24V(Transverse Orientation) Output Current(A) 16 E36SR05015(Standard) Output Current vs. Ambient Temperature and Air Velocity @Vin = 48V (Transverse Orientation) 14 Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Natural Convection 12 100LFM Figure 20: Wind tunnel test setup 200LFM 10 300LFM 400LFM 8 500LFM 6 600LFM 4 2 0 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature () Figure 23: Output current vs. ambient temperature and air velocity @ Vin=48V(Transverse Orientation) DS_E36SR05015_10292013 10 PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD) DS_E36SR05015_10292013 11 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE(for SMD models) Note: The temperature refers to the pin of E36SR, measured on the pin +Vout joint. LEAD FREE (SAC) PROCESS RECOMMEND TEMP. PROFILE(for SMD models) Temp. Peak Temp. 240 ~ 245 217 Ramp down max. 4/sec. 200 150 Preheat time 100~140 sec. Time Limited 90 sec. above 217 Ramp up max. 3/sec. 25 Time Note: The temperature refers to the pin of E36SR, measured on the pin +Vout joint. DS_E36SR05015_10292013 12 MECHANICAL DRAWING(WITH HEAT-SPREADER) * For modules with through-hole pins and the optional heatspreader, they are intended for wave soldering assembly onto system boards; please do not subject such modules through reflow temperature profile. DS_E36SR05015_10292013 13 MECHANICAL DRAWING(WITHOUT HEAT-SPREADER) Surface-mount module Pin No. 1 2 3 4 5 6 7 8 Name +Vin ON/OFF -Vin -Vout -SENSE TRIM +SENSE +Vout Through-hole module Function Positive input voltage Remote ON/OFF Negative input voltage Negative output voltage Negative remote sense Output voltage trim Positive remote sense Positive output voltage Pin Specification: Pins 1-3,5-7 Pins 4 & 8 1.00mm (0.040") diameter 2. 1.50mm (0.059") diameter NoteAll pins are copper alloy with matte-tin(Pb free) plated over Nickel underplating. DS_E36SR05015_10292013 14 PART NUMBERING SYSTEM E Type of Product 36 S Input Number of Voltage Outputs E- Eighth 36-18~75V Brick S- Single R 050 15 N R F Product Series Output Voltage Output Current ON/OFF Logic Pin Length/Type R- Regular 050- 5.0V 15-15A N- Negative R- 0.170" A Option Code F- RoHS 6/6 A(Lead Free) H- Standard Functions With Heatspreader MODEL LIST MODEL NAME INPUT OUTPUT EFF @ 100% LOAD E36SR3R320NRFA 18V~75V 4.5A 3.3V 20A 88% E36SR05015NRFA 18V~75V 5A 5.0V 15A 89% Default remote on/off logic is negative and pin length is 0.170" For different remote on/off logic and pin length, please refer to part numbering system above or contact your local sales office. CONTACT: www.deltaww.com/dcdc USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Email: DCDC@delta-corp.com Europe: Telephone: +31-20-655-0967 Fax: +31-20-655-0999 Email: DCDC@delta-es.com Asia & the rest of world: Telephone: +886 3 4526107 x 6220~6224 Fax: +886 3 4513485 Email: DCDC@delta.com.tw WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_E36SR05015_10292013 15 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Delta Electronics: E36SR05015NRFH E36SR05015NRFA