Features
Balanced TRIGARD®
Approximately 8 mm diameter, 11 mm long
UL recognized
Custom confi gurations available
High surge current rating
Stable breakdown throughout life
RoHS compliant* version available
Applications
Telecommunications
Industrial electronics
Commercial electronics
Consumer electronics
Automotive, aircraft, military electronics
Characteristics
2026 Series - 3-Pole Gas Discharge Tube
*RoHS Directive 2002/95/EC Jan 27, 2003 including Annex.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Test Methods per ITU-T (CCITT) K.12, IEEE C62.31, RUS PE-80, Telcordia GR 1361
Characteristic Model No.
2026-07 2026-09 2026-15 2026-20 2026-23 2026-25 2026-26
DC Sparkover ±20 % @ 100 V/s 75 V 90 V 150 V 200 V 230 V 250 V 260V1
Impulse Sparkover
100 V/µs
1000 V/µs
275 V
700 V
275 V
600 V
350 V
575 V
425 V
625 V
450 V
650 V
475 V
700 V
475 V
700 V
Impulse Transverse Delay .............................................1000 V/µs ................................................................. < 75 ns
Insulation Resistance ...................................................100 V (50 V for Model 2026–07 & 2026-09) ............. > 1010 Ω
Glow Voltage ................................................................10 mA ....................................................................... ~ 70 V
Arc Voltage ...................................................................1A ............................................................................. ~ 10 V
Glow-Arc Transition Current ...........................................................................................................................< 0.5 A
Capacitance .................................................................1 MHz ....................................................................... < 2 pF
DC Holdover Voltage2 .................................................>135 V, (52 V for Model 2026-07 & 2026-09, ...........< 150 ms
80 V for Model 2026-15)
Impulse Discharge Current ...........................................40000 A, 8/20 µs3 .................................................... 1 operation minimum
20000 A, 8/20 µs ...................................................... > 10 operations
5000 A, 10/350 µs ................................................... 1 operation
1000 A, 10/1000 µs ................................................. > 400 operations
Alternating Discharge Current ......................................130 Arms, 11 cycles3 ............................................... 1 operation minimum
20 Arms, 1 s ............................................................. > 10 operations
Operation and Storage Temperature .............................................................................................................. -40 to +90 °C
Climatic Category (IEC 60068-1) .................................................................................................................... 40/ 90/ 21
Optional Switch-Grade Fail-short device available.
Notes:
• UL recognized component, UL File E153537.
• Model number marking on tube: 26-xxx V.
• The rated discharge current for TRIGARD® Gas Discharge Tubes is the total current equally divided between each line to ground.
• Sparkover limits after life ±25 %, IR >108Ω (-25 %,+30 % for Model 2026-07, 2026-09 and 2026-60).
• Line to Line voltage is approximately 1.8 to 2 times the stated Line to Ground breakdown voltage.
• At delivery AQL 0.65 Level II, DIN ISO 2859
1 Tube meets BT requirement Type 14 A/1 (210-310 V).
2 Network applied.
3 DC Sparkover may exceed ±25 % after discharge, but will continue to protect without venting.
*RoHS COMPLIANT
VERSIONS
AVAILABLE
Characteristic Model No.
2026-30 2026-35 2026-40 2026-42 2026-47 2026-60
DC Sparkover ±20 % @ 100 V/s 300 V 350 V 400 V 420 V 470 V 600 V
Impulse Sparkover
100 V/µs
1000 V/µs
500 V
775 V
625 V
875 V
675 V
925 V
725 V
1000 V
800 V
1100 V
925 V
1250 V
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
2026 Series - 3-Pole Gas Discharge Tube
Product Dimensions (additional lead form confi gurations available upon request)
How to Order
2026 - nn - x n F LF
Model Number
Designator
Voltage (Divided by 10)
07 = 75 V 30 = 300 V
09 = 90 V 35 = 350 V
15 = 150 V 40 = 400 V
20 = 200 V 42 = 420 V
23 = 230 V 47 = 470 V
25 = 250 V 60 = 600 V
26 = 260 V
Leads
A = None
C = 1 mm
Lead Shape
(See Product Dimension Drawings)
Fail-Short Option
Blank = Standard Product
F = With Fail-Short Mechanism
RoHS Compliant Option
Blank = Standard Product
LF = RoHS Compliant Product
2026-XX-A
DIMENSIONS: MILLIMETERS
UNITS WITH LEADS ARE BASED ON THE
2026-XX-A1 BODY.
0.6
1.6
9.0
11.7
7.8
2026-XX-A1
0.7 - 1.0 1.0 DIA.
7.9 11.2 REF.
2026-XX-C2
13.0
MAX.
15.4
4.5
4.4
4.4
1.0 DIA.
2026-XX-C3
7.5
4.4
4.75
4.75
1.0 DIA.
2026-XX-C4
7.5
6.1
6.1
1.0 DIA.
2026-XX-C8
1.0 DIA.
7.5
2026-XX-C
1.0 mm dia. lead wire
1.0 DIA.
30
LONG
2 PLCS.
7.5
FAIL-SHORT CONFIGURATION
2026-XX-C2F SHOWN
8.1
9.6
REV. 04/11
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
2026 Series - 3-Pole Gas Discharge Tube
Switch-Grade Fail-short Device Shorting Curve 2026-XX-XF
10.0
20.0
30.0
5.0
Current (A) (ELTGS)
1.0
0.5
0.1
110 100
ELTGS = Each Line to Ground Simultaneously
NOTE: When using a GDT fail-short device, it is imperative that all components associated and
connected to the GDT with failsafe be tested in their respective completely integrated environment
(finished product) to assure desired operation.
Seconds
1000