D-70 DC Deltrol CONTROLS D-FRAME SOLENOID Two position linear solenoid with D-frame construction. Features * Balance of cost and performance * AC solenoids and DC solenoids available * UL approval on many models Electrical Specifications Coil Voltages 6, 12, 24, 110 VDC Coil Power 13 Watts Continuous, 48 Watts Intermittent, 130 Watts Pulse Coil Termination Wire leads (standard) Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4) Coil Treatment Tape wrapped Insulation Class Class A Rating - 105C (221F) Max. (standard) Class B Rating - 130C (266F) Max. (optional) Dielectric Strength 30 Volts and Under: 500 VRMS Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute Mechanical Specifications Size 2.625" (L) x 1.562" (W) x 1.828" (H) (See page 2 for dimensional drawing) Forces See force curves on page 3 Plunger Diameter 0.500" Plunger Guide Material Plastic Mounting 6X #8-32 UNC-2B Mounting Holes Weight Plunger - 1.92 oz., Total - 19 oz. Life Expectancy 250,000 Cycles (Dependent on load conditions) Agency Approval UL File No. E57982 For Continuous Duty UL File No. E74443 For Insulation Systems S105, S130 All dimensions in Inches Specifications subject to change without notice 1 of 4 Rev 07/08/11 (c)2011 Deltrol Controls - A Division of Deltrol Corp. 2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com| sales@deltrol.com D-70 DC Deltrol CONTROLS Dimensional View Units: Inches [mm] UNLESS OTHERWISE SPECIFIED INCHES .015 (MILLIMETERS 0.38) Specifications subject to change without notice 2 of 4 Rev 07/08/11 (c)2011 Deltrol Controls - A Division of Deltrol Corp. 2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com| sales@deltrol.com D-70 DC Deltrol CONTROLS Force Curves DC Continuous Duty - 13 Watts DC Intermittent Duty - 48 Watts DC Pulse Duty - 130 Watts Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum "ON" and nine (9) minutes minimum "OFF" in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds "ON" and 900 milliseconds "OFF". NOTE: Approx 36 sq. in. Heat Sink Required Specifications subject to change without notice 3 of 4 Rev 07/08/11 (c)2011 Deltrol Controls - A Division of Deltrol Corp. 2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com| sales@deltrol.com D-70 DC Deltrol CONTROLS Standard Part Numbers Duty Cycle Power Resistance (Ohms) Parts No. Voltage 50046-80 6 VDC 50046-81* 12 VDC 50046-83* 24 VDC 50046-93* 110 VDC 940 50031-80 6 VDC 0.75 50031-81* 12 VDC 50031-83* 24 VDC 50031-93* 110 VDC 53714-81 12 VDC 53714-83 24 VDC 53714-93 110 VDC Operation Typical Force (oz). 100% Voltage, 77 F, Stroke @ 0.000" 0.125" 0.250" 0.500" 0.750" Pull 150 79 62 30 15 Pull 211 130 112 82 50 Pull 247 180 165 135 100 2.75 Continuous Intermittent 13 Watts 48 Watts 11 44.3 3.0 12.0 254 Pulse 130 Watts 1.1 4.5 92 (*) Normally Stocked Non stocked items require a minimum order Specifications subject to change without notice 4 of 4 Rev 07/08/11 (c)2011 Deltrol Controls - A Division of Deltrol Corp. 2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com| sales@deltrol.com