C
D-FRAME SOLENOID
Electrical Specications
Coil Voltages 6, 12, 24, 110 VDC
Coil Power 13 Watts Continuous, 48 Watts Intermittent, 130 Watts Pulse
Coil Termination Wire leads (standard)
Duty Cycle Continuous, intermittent and pulse duty available (see standard part numbers on page 4)
Coil Treatment Tape wrapped
Insulation Class Class A Rating - 105ºC (221ºF) Max. (standard)
Class B Rating - 130ºC (266ºF) Max. (optional)
Dielectric Strength 30 Volts and Under: 500 VRMS
Over 30 Volts: 1000 VRMS plus 2X rated voltage for 1 minute
Mechanical Specications
Size 2.625” (L) x 1.562” (W) x 1.828” (H) (See page 2 for dimensional drawing)
Forces See force curves on page 3
Plunger Diameter 0.500”
Plunger Guide Material Plastic
Mounting 6X #8-32 UNC-2B Mounting Holes
Weight Plunger - 1.92 oz., Total - 19 oz.
Life Expectancy 250,000 Cycles (Dependent on load conditions)
Agency Approval
UL File No. E57982 For Continuous Duty
UL File No. E74443 For Insulation Systems
S105, S130
Two position linear solenoid with D-frame construction.
Features
• Balance of cost and performance
• AC solenoids and DC solenoids available
• UL approval on many models
All dimensions in Inches
D-70
2 of 4 Rev 07/08/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
Dimensional View
Units: Inches [mm]
UNLESS OTHERWISE SPECIFIED
INCHES ± .015
(MILLIMETERS 0.38)
D-70
3 of 4 Rev 07/08/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
Force Curves
DC Continuous Duty - 13 Watts
DC Intermittent Duty - 48 Watts
DC Pulse Duty - 130 Watts
Standard intermittent duty cycle at nominal voltage is 25%, with three (3) minutes maximum “ON” and nine (9) minutes
minimum “OFF” in a repetitive cycle. Standard Pulse duty cycle is 10% with 100 milliseconds “ON” and 900 milliseconds “OFF”.
NOTE: Approx 36 sq. in. Heat Sink Required
D-70
4 of 4 Rev 07/08/11
Specications subject to change without notice
©2011 Deltrol Controls - A Division of Deltrol Corp.
2740 South 20th Street Milwaukee, WI 53215 USA | P: 414.671.6800 | F: 414.671.6809 | www.deltrol-controls.com | sales@deltrol.com
Deltrol
CONTROLS
D
C
Parts No. Voltage Duty Cycle Power Resistance
(Ohms) Operation Typical Force (oz). 100% Voltage, 77° F, Stroke @
0.000” 0.125” 0.250” 0.500” 0.750”
50046-80 6 VDC
Continuous 13
Watts
2.75
Pull 150 79 62 30 15
50046-81* 12 VDC 11
50046-83* 24 VDC 44.3
50046-93* 110 VDC 940
50031-80 6 VDC
Intermittent 48
Watts
0.75
Pull 211 130 112 82 50
50031-81* 12 VDC 3.0
50031-83* 24 VDC 12.0
50031-93* 110 VDC 254
53714-81 12 VDC
Pulse 130
Watts
1.1
Pull 247 180 165 135 10053714-83 24 VDC 4.5
53714-93 110 VDC 92
Standard Part Numbers
(*) Normally Stocked
Non stocked items require a minimum order