A
B
C
1234
D
A
B
C
D
1 2 3 4
Copyright FCI.
REV F - 2006-04-17
(dim A)
C
( dim B)
( )18.8
TYP
0.1
( )1.5
PN / dim A B C
10056101-X01ABC1(LF) 11.9 16.5 12
10056101-X04ABC1(LF) 13.9 16.5 14
10056101-X05ABC1(LF) 11.9 18.4 12
10056101-X08ABC1(LF) 13.9 18.4 14
sheet 5 of 5
CUSTOMER-
catalog no
E
10056101
dwg no
3 Pair, 54 pos, 2mm, 6 IMLA
title
Rev.
AirMax VS VERTICAL HEADER
RECOMMENDED PCB LAYOUT
FOR DIFFERENTIAL APPLICATIONS COMPONENT SIDE
(TWO ADJACENT FOOTPRINTS SHOWN)
SEE NOTE 12.
NOMINAL OUTLINE
OF CONNECTOR
NOTES:
1. CONNECTOR MATERIALS:
HOUSING : HIGH TEMP THERMOPLASTIC, NATURAL, UL94V-0
PROTECTION COVER : HIGH TEMP THERMOPLASTIC, BLACK, UL94V-0
IMLA PLASTIC: HIGH TEMP THERMOPLASTIC, BLACK UL94V-0
CONTACT: COPPER ALLOY
2. CONTACT PLATING:
SEPARABLE INTERFACE: PERFORMANCE-BASED PLATING, QUALIFIED TO MEET THE
REQUIREMENTS OF FCI PRODUCT SPECIFICATION GS-12-239, INCLUDING
TELCORDIA GR-1217-CORE (NOV 1995) TEST SEQUENCE.
PRESS-FIT TAILS: TIN-LEAD (NON LEAD FREE) OR
TIN OVER NICKEL (LEAD FREE)
3. PRODUCT SPECIFICATION: GS-12-239.
4. APPLICATION SPECIFICATION: GS-20-035. FLATROCK INSERTION
INTO PCB BY PUSHING ON TOP OF SURFACE PROTECTION COVER
5. PRODUCT MARKING, (PARTNUMBER & LOTCODE).
6. PROTECTION COVER MUST BE REMOVED BEFORE
MATING WITH RECEPTACLE CONNECTOR
7. SEE CUSTOMER DRAWING 10045979 FOR INFORMATION ON PCB HOLE
DIAMETER AND PLATING OPTIONS.
8. LEAD FREE PRODUCT MEETS THE EUROPEAN UNION DIRECTIVE
& OTHER COUNTRY REGULATIONS AS DESCRIBED IN GS-22-008.
9. THE HOUSING SHOULD WITHSTAND EXPOSURE TO 260 $C PEAK TEMPERATURE
FOR 40 SECONDS IN A CONVECTION, INFRA-RED OR VAPOR PHASE REFLOW OVEN.
10.PACKAGE PER GS-14-1086 AND GS-14-920 LEAD FREE LABELING SPEC.
11.THERE IS NO GROUND BUSSING WITHIN THE CONNECTOR SYSTEM.
12.IT IS RECOMMENDED TO PUT THIS VISIBLE LINE AND THE A1 INDICATION
(TRIANGLE) ON THE PCB TO INDICATE PROPER ORIENTATION.
OTHER VISIBLE POLARIZATION MARKS ARE A1 INDICATOR AND PRINTING SIDE.
(SEE SHEET 3)
13.GRIPPING FEATURE TO REMOVE PROTECTION COVER BY FINGERS.
14.GRIPPING FEATURE TO REMOVE PROTECTION COVER BY STANDARD PLIERS.
15.A SYMBOL WILL BE NEXT TO ANY DIMENSION, VIEW OR NOTE WHICH HAS BEEN
MODIFIED WITH THE CURRENT DRAWING REVISION.
Triangle
indicates
position A1
SEE NOTE 12
0.1
1 2 3 4 5 6
1 2 3 4 5 6
I
H
G
F
E
D
C
B
A
OUTLINE OF CONNECTOR
WITH PROTECTION COVER
SEE DETAIL A
DETAIL A
SCALE 5:1
ALL HOLES
(TYP)
GND POSITION
SEE NOTE 7
(8x)
1.4
(TYP)3.2
2
ANTIPAD WIDTH
2.0 -(TRACE+SPACE+TRACE)
-
2010/09/22
-
2006/08/14
-
Matthew Cheong
-
Matthew Cheong
ELX-S-001612-1
E
Released
A
PDS: Rev :E STATUS:Released Printed: Feb 17, 2011