MODEL CES48033-30P CES48050-20P CES48120-7P
MAX OUTPUT WATTAGE[W] 99.0 100.0 84.0
DC OUTPUT 3.3V 30A 5.0V 20A 12V 7A
SPECIFICATIONS
MODEL CES48033-30P CES48050-20P CES48120-7P
INPUT
VOLTAGE[V] DC36 - 76
CURRENT[A] 2.29typ
EFFICIENCY[%]
HYSTERESIS VOLTAGE[V]
90typ
START-UP VOLTAGE[V] DC32 - 36
DC2 min
90typ 91typ
2.32typ 1.93typ
OUTPUT
VOLTAGE[V] 3.3 5 12
CURRENT[A] 30 20 7
LINE REGULATION[mV] t5max
LOAD REGULATION[mV] t5max
RIPPLE
[mVrms]
*2
20max 20max 40max
[mVp-p]
*2
*1
*1
60max 80max 120max
RIPPLE NOISE[mVp-p]
*2
100max 120max 150max
*3
66max 100max 240max
TEMPERATURE REGULATION[mV]
16max 20max 40max
DRIFT[mV]
*5
*5
*4
*5
-15% / +15%
START-UP TIME[ms] 200max (DCIN 48V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE
Fixed (TRM pin open), adjustable by external resistor
OUTPUT VOLTAGE SETTING
t1.6%
-20% / +20% -20% / +10%
125% - 145% 115% - 135%
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating,low voltage protection (shut down) function is built-in
OVERVOLTAGE PROTECTION
120% - 140%
REMOTE SENSING Provided
REMOTE ON/OFF Provided (Negative logic L:ON, H:OFF)
ISOLATION
INPUT-OUTPUT DC1,500V or AC1,000V 1minute,Cutoff current = 10mA,DC500V 50M Wmin (20t15C)
DC1,500V or AC1,000V 1minute,Cutoff current = 10mA,DC500V 50M Wmin (20t15C)
INPUT-BASEPLATE
OUTPUT-BASEPLATE AC500V 1minute,Cutoff current = 100mA,DC500V 50M Wmin (20t15C)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-40 to +85C,20 - 95%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-40 to +100C,20 - 95%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,49.0m/s2(5G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each along X,Y and Z axis
SAFETY AGENCY APPROVALS UL60950-1,C-UL (CSA60950-1), EN60950-1
OTHERS CASE SIZE/WEIGHT 57.9 X12.7X36.8mm [2.28X0.5X1.45 inches] (W
XHXD)/ 50g max
57.9 X8.5X22.76mm [2.28X0.33X0.9 inches] (W
XHXD)/ 26g max
COOLING METHOD Convection / Forced air / Conduction
*1At rated input(DC48V) and rated load. Ta=25C, 2m/s.
*2Ripple and ripple noise is measured by using measuring board with ceramic capacitor 22mF.
*3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
*4DC40V or more input voltage is required to trim the output voltage up more than rated output +10%.
*5BasePlate Option.
CES Type-P
DC-DC Converters Power Module type
Ordering information
1Series name
2Single output
3Input voltage
48:DC36 - 76V
4Output voltage
033:3.3V
050:5.0V
120:12V
5Output current
6Type
P :Conduction Cooling
7Optional
R :with Remote ON/OFF
Positive logic control
N:
Auto restart from thermal
protection
B :BasePlate option
(Mounting hole M3)
BT :BasePlate option
(Mounting holef3.4 thru)