667 FIBER SENSORS Dual Display Digital Pressure Sensor DP-100 SERIES Related Information LASER SENSORS General terms and conditions............ F-17 SC-SU1........................................... P.917 General precautions...................... P.1405 For Gas Sensor selection guide.................. P.661~ Glossary of terms.......................... P.1373 Korea's S-mark.............................. P.1410 PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Conforming to EMC Directive Recognition AREA SENSORS Certified [DP-101(A)/102(A) only] LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS * Passed the UL 991 Environment Test SENSOR OPTIONS * UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200. [Category applicable for semiconductor manufacturing: TWW2, Process Equipment] [Applicable standards: UL 61010C-1] [Additional test / evaluation standards as per intended use: UL 991, SEMI S2-0200] SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic-electric-works.net/sunx STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Digital Auto reference With analog output Dual 3-color display makes operation easier! The dual display means that the "current value" and the "threshold value", it makes direct setting of threshold value Equipped with a 30 mm 1.181 in square compact-sized dual display. Because the current value and the threshold value can be checked at the same time, the threshold value can be set and checked smoothly without having to switch screen modes. ON / OFF operations are still carried out while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. And naturally a key lock function is also equipped. FA COMPONENTS Current value Previous model with single display Threshold value setting method MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated -91.8 Note current value Operate MODE key Adjust threshold value Return to RUN operation DP-100 with dual display Simply press a button during RUN operation Man-hours reduced by 3/4 Threshold value Flow Other Products DP-100 DP-M 3-color display (Red, Green, Orange) Readable digital display The main display changes color in line with changes in the status of output ON / OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced. 12 segments are used and an alphanumeric display has been adopted. This improves visual checking of letters and numbers. Main Display OFF: Green (or Red) ON: Red (or Green) During normal operation SET: Orange During setting Dual Display Digital Pressure Sensor DP-100 SERIES APPLICATIONS 668 FIBER SENSORS Confirming suction of electronic component Confirming reference pressure Air-leak test for PET bottles LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS BASIC PERFORMANCE All models in the line-up are compound pressure types High performance accomplished Low pressure type No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), 0.5 % F.S. temperature characteristics and 0.1 % F.S. repeatability, giving it high performance. Ideal for applications such as suction. No mis-operations due to vacuum breakdown occur. -100 kPa For low pressure 100 kPa 0 kPa DP-101 Ideal for applications such as checking reference pressure. Can also be used for simple suction. 1 MPa For high pressure DP-102 Resolution: 1/2,000 Response time: 2.5 ms Temperature characteristics: 0.5 % F.S. Repeatability: 0.1 % F.S. Displays measurements in 0.1 kPa SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS FUNCTIONS HUMAN MACHINE INTERFACES Copy function reduces man-hours and human error ENERGY CONSUMPTION VISUALIZATION COMPONENTS Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to the other sensors. If making the same settings for multiple sensors, this prevents setting errors from occurring with the other sensors and also reduces the number of changes required to instruction manuals when equipment designs are changed. Details transmitted Copying via wiring Master sensor Power supply +V +V 0V 0V Comparative output 1 Comparative output 1 Comparative output 2 Comparative output 2 Details received Slave sensor Detail s cop ied FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow The sensor's setting operation mode has a 3-level configuration to suit the frequency of use The setting levels are clearly separated into "RUN mode" for operation settings that are carried out daily, "MENU SETTING mode" for basic settings, and "PRO mode" for special and detailed setting. These make setting operations easy to understand and easy to carry out. Simple setting RUN mode MENU SETTING mode Special and detailed setting PRO mode Other Products DP-100 RUN mode Settings such as threshold value adjustment and key lock operation can be carried out while the sensor is operating. MENU SETTING mode Basic settings such as output mode setting and NO / NC switching can be carried out. PRO mode High-level function settings such as hysteresis adjustment and the copy function can be carried out. DP-M PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS FUNCTIONS Equipped with independent dual output and three output modes Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, if an output is not being used, it can be disabled. Vacuum breakdown can also be checked during suction applications! PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS ON Comparative output 1 EASY mode OFF ON Comparative output 2 EASY mode OFF SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS -100 kPa P-1 0 kPa Alarm output ON LASER MARKERS Comparative output 2 EASY mode OFF PLC / TERMINALS 0 kPa Lo-1 Hi-1 P-2 HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Hysteresis mode Hi H (Hysteresis) Lo 0 ON Comparative output OFF Note: " " or " output 1, and " 3 H: 1 digit or more " appears in the sub display for comparative " or " " appears for comparative output 2. Window comparator mode This mode is used for setting comparative output ON and OFF at pressures within the setting range. H (Hysteresis) Hi H (Hysteresis) Lo 0 ON Comparative output OFF H: Fixed Equipped with auto-reference / remote zero-adjustment functions, more precise pressure management is possible with a minimum of effort Multi-function type If the reference pressure of the device changes, the auto-reference function partially shift the comparative output judgment level by the amount that the reference pressure shifts, and the remote zero-adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are desired. With auto-reference function applied Flow Other Products H: Fixed Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) " " or " " appears in the sub display for comparative output 1, and " " or " " appears for comparative output 2. FA COMPONENTS UV CURING SYSTEMS 0 ON OFF Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) " "appears in the sub display for comparative output 1, and " " appears for comparative output 2. P-2 Reference pressure checking ENDOSCOPE MACHINE VISION SYSTEMS Comparative output H (Hysteresis) P Vacuum breakdown checking ON Comparative output 1 hysteresis mode OFF STATIC CONTROL DEVICES EASY mode This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON / OFF control. Reference pressure alarm output is possible during reference pressure checking! MEASUREMENT SENSORS Standard type This mode is used for comparative output ON / OFF control. 2 PARTICULAR USE SENSORS WIRE-SAVING SYSTEMS Suction checking 1 Pressure LASER SENSORS DP-100 SERIES Pressure FIBER SENSORS Dual Display Digital Pressure Sensor Pressure 669 With remote zero-adjustment function applied Comparative output: Window comparator mode Hi-1...0, Lo-1...-5 Sets the absolute threshold level Auto-reference input The display remains at "30" and only the threshold level is changed. DP-100 DP-M 30 Comparative output: Window comparator mode Hi-1...0, Lo-1...-5 Sets the absolute threshold level Remote zero-adjustment input The display is forced to "0", and only the filling pressure drop range is displayed. 30 OK 25 20 Threshold level after applying auto-reference input 15 0 -5 25 20 Threshold level after applying remote zero-adjustment input 15 Threshold level before applying auto-reference input Threshold level before applying remote zero-adjustment input Trial 1 Pressure 0 -5 Trial 1 Pressure 0 Auto-reference input value... Time When auto-reference input is applied, the reference pressure "30" is added to the threshold level. If the reference pressure changes to "20" or "40", the auto-reference input compensates for this every time by changing the threshold level, so any variation in the filling pressure can be ignored. OK -5 Time Displayed when remote zero-adjustment input is applied... When remote zero-adjustment input is applied, the reference pressure is forced to "0". If the reference pressure changes to "20" or "40", the remote zero-adjustment input adjusts the reference pressure to "0" every time the reference pressure changes, so any variation in the filling pressure can be ignored. Dual Display Digital Pressure Sensor DP-100 SERIES FUNCTIONS Sub display can be customized Setting details can be understood at a glance The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. The DP-100 setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful for times such as when receiving technical support by telephone. 2nd digit: Setting status for comparative output 2 1st digit: Setting status for comparative output 1 3rd digit: Threshold value setting 4th digit: Display color setting 670 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 5th digit: Response time setting 6th digit: Display unit setting 8th digit: ECO mode setting 7th digit: Display refresh rate setting MOUNTING MEASUREMENT SENSORS An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. Takes up much less space SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Tight installation to panels is possible Tight installation is possible SENSOR OPTIONS STATIC CONTROL DEVICES Front protection cover available MS-DP1-3 ENDOSCOPE LASER MARKERS A single mounting hole! PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available Space savings can also be obtained if an L-shaped mounting bracket is used. * MS-DP1-1 * MS-DP1-5 FA COMPONENTS Tight installation is possible MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Ceiling mounting Floor mounting Rear mounting Positioning bosses for easier mounting bracket installation Cable can be connected with one-touch connection Types without connector attached cable are also available The accessory connector attached cable (2 m 6.562 ft) can be connected easily with one-touch connection. Commercially-available connectors can be used for cable connections. Only the required length of cable needs to be used, which contributes to a reduced amount of wastage for unneeded cable. DP-10-J Environmentally friendly * Connection cable * Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available. Commercially-available parts can be used! Flow Other Products DP-100 DP-M 671 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Dual Display Digital Pressure Sensor DP-100 SERIES VARIETIES DP-10-M Short pressure port type is lightweight and takes up little space Compact size with a depth of only 30 mm 1.181 in, so that it can easily fit into narrow spaces. Further, 10 g lighter than standard types. This reduces the loads on movable parts such as robot arms. Standard type M5 female thread + R 1/8 male thread Elbow joint Short pressure port type DP-10-M LIGHT CURTAINS PRESSURE / FLOW SENSORS Short pressure port type INDUCTIVE PROXIMITY SENSORS Shortened to 12.5 mm 0.492 in ! Light weight 30g approx. PARTICULAR USE SENSORS SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS M5 female thread [Material: Stainless steel (SUS)] 30 mm 1.181 in SIMPLE WIRE-SAVING UNITS *T he illustration shows connection using an elbow joint. The elbow joint is sold separately. M8 piug-in connector types are also available (for Europe) STATIC CONTROL DEVICES Mating cable CN-24A-C2 (cable length 2 m 6.562 ft) CN-24A-C5 (cable length 5 m 16.404 ft) ENDOSCOPE DP-11-E-P-J M8 connector LASER MARKERS PLC / TERMINALS G 1/8 male thread M5 female thread HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Switch-over of the pressure port or flat mounting For short pressure port type on the wall is possible Rc1/8 conversion bushing improves compatibility with the previous model For short pressure port type By mounting the flat attachment to DP-10-M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible. By equipping the push-in converter with DP-10-M(-P), pressure port can be converted from M5 female thread to Rc1/8 female thread. Bore diameter conversion to the DP2 / DP3 series is possible. Previous model DP2 / DP3 series can be switched over to DP-100 series. Previous model Pressure/ Digital Display Pressure/ Head-separated Flow M5 female thread Rc1/8 female thread Flat attachment MS-DP1-F Other Products 20 mm 0.787 in pitch DP-100 Model No. DP-M 3 possible directions to mount 20 mm 0.787 in pitch Pressure port MS-DP1-FM M5 female thread MS-DP1-FR Rc1/8 female thread MS-DP1-FN NPT1/8 female thread MS-DP1-FE G1/8 female thread Conversion bushing MS-DP1-7 Dual Display Digital Pressure Sensor DP-100 SERIES ORDER GUIDE FIBER SENSORS Asia Type Standard Multi-function Europe M8 plug-in connector type Multi-function North America Standard pressure port type Standard Standard Multi-function For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa For low pressure -100.0 to +100.0 kPa For high pressure -0.100 to +1.000 MPa Standard Multi-function For high pressure Standard Asia Short pressure port type Rated pressure range Appearance For low pressure Multi-function 672 *CN-14A-C2 Connector attached cable 2 m 6.562 ft is attached. Excluding M8 plug-in connector type ( ( ) -100.0 to +100.0 kPa ) -0.100 to +1.000 MPa Model No. DP-101 DP-102 DP-101A DP-102A DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J DP-101-N DP-101-N-P DP-102-N DP-102-N-P DP-101A-N DP-101A-N-P DP-102A-N DP-102A-N-P For low pressure -100.0 to +100.0 kPa DP-101-M For high pressure -0.100 to +1.000 MPa DP-102-M For low pressure -100.0 to +100.0 kPa DP-101A-M For high pressure -0.100 to +1.000 MPa DP-102A-M Type without connector attached cable Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix "-J" to the Model No. (e.g.) Type without connector atlached cable of DP-101-N is "DP-101-N-J" Accessory * CN-14A-C2 (Connector attached cable 2 m 6.562 ft) LASER SENSORS Pressure port Comparative output M5 female thread + R 1/8 male thread NPN open-collector transistor M5 female thread + G 1/8 male thread PNP open-collector transistor M5 female thread + G 1/8 male thread PNP open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor NPN open-collector transistor PNP open-collector transistor M5 female thread MICRO PHOTOELECTRIC SENSORS AREA SENSORS NPN open-collector transistor M5 female thread + NPT 1/8 male thread PHOTOELECTRIC SENSORS NPN open-collector transistor LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Other Products DP-100 DP-M 673 FIBER SENSORS Dual Display Digital Pressure Sensor DP-100 SERIES OPTIONS LASER SENSORS PHOTOELECTRIC SENSORS Designation Model No. Connector attached cable Description * CN-14A-C * CN-14A-R-C CN-14A-C1 CN-14A-C2 (Note) CN-14A-C3 CN-14A-C5 CN-14A-R-C1 CN-14A-R-C2 CN-14A-R-C3 CN-14A-R-C5 CN-24A-C2 CN-24A-C5 CN-14A Length: 1 m 3.281 ft MS-DP1-1 Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. MS-DP1-5 Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. MS-DP1-2 Allows installation to panels with thickness of 1 to 6 mm 0.039 to 0.236 in. Multiple sensors can also be mounted closely. MS-DP1-4 Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed set-up, please use panel mounting bracket MS-DP1-2 for panel mounting. STATIC CONTROL DEVICES Front protection cover MS-DP1-3 Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket) ENDOSCOPE Conversion bushing MS-DP1-7 By equipping with DP-10-M(-P), pressure port can be converted to Rc1/8 female thread. Replacement from DP2 / DP3 series is possible. MS-DP1-FM MS-DP1-FR MS-DP1-FN MS-DP1-FE SC-SU1 M5 female thread MICRO PHOTOELECTRIC SENSORS Connector attached cable AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS Connector attached cable (Flexible cable) INDUCTIVE PROXIMITY SENSORS M8 connector attached cable PARTICULAR USE SENSORS Connector SENSOR OPTIONS Sensor mounting bracket SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Panel mounting bracket Flat attachment Copy unit 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: o3.7 mm o0.146 in Length: 2 m 6.562 ft Length: 3 m 9.843 ft Length: 5 m 16.404 ft Length: 1 m 3.281 ft 0.2 mm2 4-core flexible cabtyre cable with connector on one end Cable outer diameter: o3.7 mm o0.146 in Length: 2 m 6.562 ft Length: 3 m 9.843 ft Length: 5 m 16.404 ft For M8 plug-in connector type The connector on one end Length: 5 m 16.404 ft Cable outer diameter: o4 mm o0.157 in Set of 10 housings and 40 contacts Length: 2 m 6.562 ft Pressure port and cable can now be pulled out in downward, left or right directions. Flat NPT1/8 female thread mounting on surfaces such as the wall is made possible. G1/8 female thread Rc1/8 female thread M8 connector attached cable * CN-24A-C 31.4 1.236 o9 o0.354 * MS-DP1-1 M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-1 ( Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series. (Excluding M8 plug-in connector type). * MS-DP1-4 Front protection cover MS-DP1-3 DP2 / DP3 DP 2-2 0 n101 .3kPa Remove OUT 1 OUT 2 0-AD J MOD E Remove * MS-DP1-5 M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-5 Insert DP-100 Selection Guide Panel mounting bracket MS-DP1-2 Pressure/ Digital Display Pressure/ Head-separated Flow Other Products Flat attachment * MS-DP1-FM ) Sensor mounting bracket MS-DP1-1 Panel mounting bracket, Front protection cover Front protection cover DPX-04 (optional) can be installed on MS-DP1-4. (Unit: mm in) Sensor mounting bracket Copy the controller settings to other controllers. * MS-DP1-2 * MS-DP1-3 o4 o0.157 Mounting holes for DP2 / DP3 series can be used as is. ( ) Panel mounting bracket MS-DP1-4 Sensor mounting bracket MS-DP1-5 * MS-DP1-FR * MS-DP1-FN * MS-DP1-FE DP-100 DP-M Net weight: MS-DP1-FM 15 g approx. MS-DP1-FR/FN/FE 25 g approx. Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. Recommended connector Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg.Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Copy unit Conversion bushing * MS-DP1-7 M5 female thread Rc1/8 female thread * SC-SU1 Conversion bushing MS-DP1-7 Dual Display Digital Pressure Sensor DP-100 SERIES SPECIFICATIONS Item Model No. Type FIBER SENSORS Standard LASER SENSORS Multi-function For low pressure For high pressure For low pressure For high pressure DP-101(-M)(-P) DP-102(-M)(-P) DP-101A(-M)(-P) DP-102A(-M)(-P) DP-101-E-P DP-102-E-P DP-101A-E-P DP-102A-E-P M8 plug-in connector type DP-111-E-P-J DP-112-E-P-J DP-111A-E-P-J DP-112A-E-P-J North America (Note 2) DP-101-N(-P) DP-102-N(-P) DP-101A-N(-P) DP-102A-N(-P) -100.0 to +100.0 kPa -0.100 to +1.000 MPa -100.0 to +100.0 kPa -0.100 to +1.000 MPa -100.0 to +100.0 kPa -1.020 to +1.020 kgf/cm2 -1.000 to +1.000 bar -14.50 to +14.50 psi -750 to +750 mmHg -29.5 to +29.5 inHg -0.100 to +1.000 MPa -100 to +1,000 kPa -1.02 to +10.20 kgf/cm2 -1.00 to +10.00 bar -14.6 to +145.0 psi -100.0 to +100.0 kPa -1.020 to +1.020 kgf/cm2 -1.000 to +1.000 bar -14.50 to +14.50 psi -750 to +750 mmHg -29.5 to +29.5 inHg -0.100 to +1.000 MPa -100 to +1,000 kPa -1.02 to +10.20 kgf/cm2 -1.00 to +10.00 bar -14.6 to +145.0 psi 500 kPa 1.5 MPa 500 kPa 1.5 MPa Asia (Note 2) Europe Type of pressure Rated pressure range Set pressure range Pressure withstandability Gauge pressure Applicable fluid Non-corrosive gas Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi Supply voltage Power consumption 12 to 24 V DC 10 % Ripple P-P 10 % or less Normal operation: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage) ECO mode: 600 mW or less at STD (Current consumption 25 mA or less at 24 V supply voltage) 480 mW or less at FULL (Current consumption 20 mA or less at 24 V supply voltage) PNP open-collector transistor NPN open-collector transistor Comparative output * Maximum source current: 100 mA * Maximum sink current: 100 mA * Applied voltage: 30 V DC or less (between comparative output and +V) * Applied voltage: 30 V DC or less (between comparative output and 0 V) * Residual voltage: 2 V or less (at 100 mA source current) * Residual voltage: 2 V or less (at 100 mA sink current) Output operation / Output modes NO / NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode Hysteresis Repeatability Response time Minimum 1 digit (variable) (however, 2 digits when using psi unit) 0.1 % F.S. (within 2 digits) 0.2 % F.S. (within 2 digits) External input (Note 3) Auto-reference function / Remote zero-adjustment function - Analog voltage output (Note 3) - Displayable pressure range Incorporated ON voltage: 0.4 V DC or less OFF voltage: 5 to 30 V DC, or open Input impedance: 10 k approx. Input time: 1 ms or more Output voltage: 1 to 5 V DC Zero point: within 3 V 5 % F.S. Span: within 4 V 5 % F.S. Linearity: within 1 % F.S. Output impedance: 1 k approx. Environmental resistance Protection Ambient temperature Ambient humidity Voltage withstandability Insulation resistance Vibration resistance 0.2 % F.S. (within 2 digits) ON voltage: 5 V to +V DC OFF voltage: 0.6 V DC or less, or open Input impedance: 10 k approx. Input time: 1 ms or more Output voltage: 0.6 to 5 V Zero point: within 1 V 5 % F.S. Span: within 4.4 V 5 % F.S. Linearity: within 1 % F.S. Output impedance: 1 k approx. 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) -100.0 to +100.0 kPa -1.020 to +1.020 kgf/cm2 -1.000 to +1.000 bar -14.50 to +14.50 psi -750 to +750 mmHg -29.5 to +29.5 inHg -0.100 to +1.000 MPa -100 to +1,000 kPa -1.02 to +10.20 kgf/cm2 -1.00 to +10.00 bar -14.6 to +145.0 psi Orange LED Indicator 0.1 % F.S. (within 2 digits) 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation Short-circuit protection Display Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON -100.0 to +100.0 kPa -1.020 to +1.020 kgf/cm2 -1.000 to +1.000 bar -14.50 to +14.50 psi -750 to +750 mmHg -29.5 to +29.5 inHg -0.100 to +1.000 MPa -100 to +1,000 kPa -1.02 to +10.20 kgf/cm2 -1.00 to +10.00 bar -14.6 to +145.0 psi Orange LED Comparative output 1 operation indicator: Lights up when comparative output is ON, Analog voltage output operation indicator: Lights up when setting IP40 (IEC) -10 to +50 C +14 to +122 F, Storage: -10 to +60 C +14 to +140 F (No dew condensation or icing allowed) 50 M, or more, with 500 V DC megger between all supply terminals connected together and enclosure 10 to 500 Hz frequency, 3 mm 0.118 in amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each Within 0.5 % F.S. (at +20 C +68 F) Within 1 % F.S. (at +20 C +68 F) Within 0.5 % F.S. (at +20 C +68 F) Within 1 % F.S. (at +20 C +68 F) Pressure port Asia: M5 female thread + R (PT) 1/8 male thread (excluding DP--M(-P)), Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303)] , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber Connecting method / Cable length Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. Weight Accessories PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS LIGHT CURTAINS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Other Products 35 to 85 % RH, Storage: 35 to 85 % RH 1,000 V AC for one min. between all supply terminals connected together and enclosure Temperature characteristics Material 674 Net weight: 40 g approx. [DP-10-M(-P): 30 g approx.], Gross weight: 135 g approx. [DP-10-M(-P): 125 g approx.] CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 C +68 F. 2) Model Nos. of Asia type having "-M" are short pressure port type. Model Nos. of North America type having the suffix "-P" are PNP output type. 3) Cannot be used at the same time. DP-100 DP-M 675 Dual Display Digital Pressure Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS DP-10 NPN output type I/O circuit diagram SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Color code of connector attached cable 1 2 Tr1 ZD1 Tr2 ENDOSCOPE HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS 5V + - 3 4 Terminal No. (Blue) 0 V Designation 1 +V 2 Comparative output 1 3 Standard type: Comparative output 2 Multi-function type: Analog voltage output or External input 4 0V Color code of connector attached cable 3 1k 2 (White) Analog voltage output or External input Load (Black) Comparative output 1 + - 12 to 24 V DC 10 % 100mA max. ZD1 4 Internal circuit (Blue) 0 V Users' circuit Symbols ... D1, D2: Reverse supply polarity protection diode ZD1: Surge absorption zener diode Tr1 : PNP input transistor Tr2 : NPN output transistor DP-10-P PNP output type I/O circuit diagram Terminal arrangement diagram Terminal No. Standard type Color code of connector attached cable ZD1 Tr1 D (Brown) +V 1 100mA max. ZD2 Tr2 2 (Black) Comparative output 1 100mA max. Load 3 (White) Comparative output 2 Load (Blue) 0 V + - Internal circuit Users' circuit Symbols ... D: Reverse supply polarity protection diode ZD1, ZD1: Surge absorption zener diode Tr1, Tr2: PNP output transistor DP-100 Terminal No. Sensor circuit Multi-function type D1 ZD1 Tr1 D2 3 4 Internal circuit (Brown) +V 100mA max. 2 1k Tr2 Color code of connector attached cable 1 (Black) Comparative output 1 (White) Analog voltage output Load or External input + - (Blue) 0 V Users' circuit Symbols ... D1, D2: Reverse supply polarity protection diode ZD1: Surge absorption zener diode Tr1 : PNP output transistor Tr2 : NPN input transistor 1 12 to 24 V DC 10 % 4 Flow DP-M 2 (Brown) +V 1 D2 Tr2 1 12 to 24 V DC 10 % Terminal No. D1 Tr1 Pressure/ Head-separated Other Products (White) Comparative output 2 Users' circuit Multi-function type Sensor circuit Pressure/ Digital Display Load Symbols ... D: Reverse supply polarity protection diode ZD1, ZD1: Surge absorption zener diode Tr1, Tr2: NPN output transistor UV CURING SYSTEMS Selection Guide 3 Internal circuit LASER MARKERS PLC / TERMINALS 100mA max. 4 Sensor circuit STATIC CONTROL DEVICES (Black) Load Comparative output 1 100mA max. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS (Brown) +V ZD2 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Terminal No. D Sensor circuit PRESSURE / FLOW SENSORS Terminal arrangement diagram Standard type AREA SENSORS LIGHT CURTAINS DP-100 SERIES 12 to 24 V DC 10 % 2 3 4 Terminal No. Designation 1 +V 2 Comparative output 1 3 Standard type: Comparative output 2 Multi-function type: Analog voltage output or External input 4 0V Dual Display Digital Pressure Sensor DP-100 SERIES 676 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS DP-11-E-P-J PNP output type I/O circuit diagram Terminal No. Sensor circuit Color code of connection cable ZD1 Tr1 D 1 Tr2 4 (Black) Comparative output 1 100 mA max. Load 2 (White) Comparative output 2 Load (Blue) 0 V Internal circuit + - 12 to 24 V DC 10 % Users' circuit Symbols ... D: Reverse supply polarity protection diode ZD1, ZD1: Surge absorption zener diode Tr1, Tr2: PNP output transistor Sensor circuit D1 ZD1 1 AREA SENSORS Terminal No. Designation 1 +V 2 Standard type: Comparative output 2 Multi-function type: Analog voltage output or External input 3 0V 4 Comparative output 1 (Black) Comparative output 1 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS + - 12 to 24 V DC 10 % STATIC CONTROL DEVICES ENDOSCOPE (Blue) 0 V LASER MARKERS Users' circuit Symbols ... D1, D2: Reverse supply polarity protection diode ZD1: Surge absorption zener diode Tr1: PNP output transistor Tr2: NPN input transistor PLC / TERMINALS HUMAN MACHINE INTERFACES PRECAUTIONS FOR PROPER USE * Never use this product as a sensing device for personnel protection. * In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. * The DP-100 series is designed for use with non-corrosive gas. It cannot be used with liquid or corrosive gas. Connection * Do not apply stress directly to the connection cable leader or to the connector. LIGHT CURTAINS SIMPLE WIRE-SAVING UNITS (Brown) +V (White) Analog voltage output Load 2 or External input 3 Internal circuit 4 100 mA max. 4 D2 3 MICRO PHOTOELECTRIC SENSORS Terminal No. Color code of connection cable Multi-function type Tr2 2 (Brown) +V 3 1k 1 100 mA max. ZD2 Tr1 PHOTOELECTRIC SENSORS Terminal arrangement diagram Standard type LASER SENSORS Refer to General precautions. Mounting * The MS-DP1-1 sensor mounting bracket is available separately, and it should be used for mounting. When tightening the sensor to the sensor mounting bracket, use a tightening torque of 0.5 N*m or less. M3 (length 6 mm 0.236 in) screws with washers (Accessory for MS-DP1-1) MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Flow Other Products Connector attached cable [CN-14A(-R)-C] * The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3 front protection cover (optional) are also available. Front protection cover MS-DP1-3(optional) Conditions * The line to connect with this sensor should be less than 30 m 98.425 ft. FA COMPONENTS Pressure/ Head-separated Sensor mounting bracket MS-DP1-1 (Optional) Conditions in use for CE conformity * The DP-100 series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 and the following condition must be met to conform to that standard. ENERGY CONSUMPTION VISUALIZATION COMPONENTS Panel mounting bracket MS-DP1-2(optional) DP-100 DP-M 677 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Dual Display Digital Pressure Sensor PRECAUTIONS FOR PROPER USE Mounting * The MS-DP1-4 panel mounting bracket is available when switching from the DP2 / DP3 series. DP2 / DP3 DP 2-2 0 n10 1 OUT 0-AD J 2 MO DE Remove Insert DP-100 INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS WIRE-SAVING SYSTEMS Pa OUT Remove PRESSURE / FLOW SENSORS SIMPLE WIRE-SAVING UNITS 1.3k Front protective cover DPX-04 (Optional) can be installed on MS-DP1-4. LIGHT CURTAINS SENSOR OPTIONS DP-100 SERIES Mounting holes for DP2 / DP3 series can be used as is. Panel mounting bracket MS-DP1-4 * An conversion bushing is available for when using the DP-10-M short pressure port type. It can be used to switch between this model and the DP2 / DP3 series. When connecting to the pressure port, use a tightening torque of M5 female thread Rc1/8 female thread 1.0 N*m or less. Refer to General precautions. Piping 12 mm 0.472 in * If connecting a commercially-available spanner coupling to the pressure port, attach a 12 mm 0.472 in spanner (14 mm 0.551 in spanner for DP-100-E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N*m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port. In addition, wrap sealing tape around the coupling when connecting it to prevent leaks. * If connecting a commercially-available joint to the pressure port of the DP-10-M, hold the main unit in your hand to steady it, and tighten to a torque of 1.0 N*m or less. If it is tightened to an excessive torque, the joint or the main unit may become damaged. * If connecting a commercially-available joint to the pressure port of the MS-DP1-7, tighten to a torque of 9.8 N*m or less. 14 mm 0.551 in spanner MEASUREMENT SENSORS STATIC CONTROL DEVICES Conversion bushing MS-DP1-7 ENDOSCOPE LASER MARKERS PLC / TERMINALS * The MS-DP1-F flat attachment is available. If using the MS-DP1-F flat attachment (optional), install by following the procedures given below. 1 Decide the direction of this product to mount with the sensor. * The tightening torque should be 1 N*m or less when connecting a coupling to the pressure port of MS-DP1-FM. HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS Pressure port FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Coupling (Purchase separately.) Pressure port faces downward Pressure port faces leftward Note: It is not possible to mount this product such that the pressure port faces upward. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Pressure port faces rightward Pressure port faces upward * When connecting the coupling to the pressure port of MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm 0.551 in spanner and make sure that the tightening torque is 9.8 N*m or less. In addition, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. 2 Mount this product with the M3 female threads of the sensor by using the attached M3 (length 8 mm 0.315 in) screws. The tightening torque should be 0.5 N*m or less. M3 female thread Other Products M3 (length 8 mm 0.315 in) screw (Accessory) DP-100 DP-M 14 mm 0.551 in spanner M3 female thread 3 Mount this product with the mounting surface by using the attached M4 (length 20 mm 0.787 in) screws. The tightening torque should be 1.2 N*m or less. Groove Groove Connector Connector attachedattached cable cable M420 (length 20 mm M4 (length mm 0.787 in)0.787 in) screw (Accessory) screw (Accessory) Note: Take Note: care Take that care if the thatcable if thewith cable connector with connector is sticking is sticking out of the outside of the side groove groove of this product of this product when mounting, when mounting, the cable themay cable disconnected. may disconnected. Note: Do not tighten the pressure port by holding the product with the spanner. It may cause the product breakage. Flat attachment * Make sure to mount MS-DP1-F with the sensor properly. If it is not mounted properly, air leakage may occur. * Take care that the excessive mounting and dismounting of this product may cause deterioration of the O-ring. * If you touch the O-ring of MS-DP1-F, or any scratch or dust, etc. is attached to it, air leakage may occur and the sensing performance may deteriorate. Take sufficient care when using and storing MS-DP1-F. Dual Display Digital Pressure Sensor PRECAUTIONS FOR PROPER USE DP-100 SERIES 678 Refer to General precautions. LASER SENSORS PRO mode Others * Use within the rated pressure range. * Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. * Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. * Avoid dust, dirt, and steam. * Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. * Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. * Do not operate the keys with pointed or sharp objects. RUN mode * This is the normal operating mode. Setting item Description Threshold value setting The threshold values for ON / OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). Zero-adjustment function This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Key lock function Stops key operations from being accepted. Peak hold / bottom hold function Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. * If the mode selection key is pressed and held for 5 sec. in RUN mode, the mode will switch to PRO mode. * If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Setting item Sub display switching Changes the information in the sub display during RUN mode operation to the desired alphanumeric display. Display refresh rate switching Changes the display refresh rate for the pressure value displayed in the main display. Hysteresis fix value switching Sets the response time for EASY mode and window comparator mode. (8 steps) Linked display color switching (standard type only) Allows the display color for the main display to be switched in line with the output operation for comparative output 1 or comparative output 2. ECO mode setting Allows power consumption to be reduced by dimming the display or turning it off. Setting check code Allows the setting details to be checked via codes. Setting copy mode Allows the setting details for the master sensor to be copied to slave sensors. Reset setting Resets the settings to the factory settings. Code Table of codes Description Sets the output mode for comparative output 1. Comparative output 2 output mode Sets the output mode for comparative output 2. setting (standard type only) Allows switching between analog voltage output and auto-reference input / remote zero-adjustment input. NO / NC switching Sets normally open (NO) or normally closed (NC). Response time setting Sets the response time. The response time can be selected from 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms and 5,000 ms. Display color switching for main display Unit switching AREA SENSORS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES ENDOSCOPE Allows the color for the main display to be changed. The colors can be set to "red / green" or "green / red" to correspond to ON / OFF output, or it can be fixed at "red" or "green" all the time. Pressure unit can be changed. 1st digit Comparative NO / NC output 1 output mode switching NO EASY NC NO Hysteresis NC NO Window comparator NC - - - - 4th digit Standard type only 2nd digit 3rd digit Standard type Multi-function type Comparative NO / NC Analog voltage Threshold Display Display output 2 value output / color for output mode switching External input display main display color linking Comparative voltage OFF Analog OFF P-1, Lo-1 Red output output 1 Autowhen ON Comparative NO Hi-1 output 2 reference EASY Comparative Remote NC output 1 zero-adjustment P-2, Lo-2 Green Comparative when ON - NO Hi-2 output 2 Hysteresis Comparative - NC ADJ. Always output 1 Comparative red - - NO output 2 Window Comparative comparator - - NC Always output 1 Comparative green - - - - output 2 PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Code Analog voltage output / external input switching (multi-function type only) MICRO PHOTOELECTRIC SENSORS LASER MARKERS * If the mode selection key is pressed and held for 2 sec. in RUN mode, the mode will switch to MENU SETTING mode. * If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Comparative output 1 output mode setting PHOTOELECTRIC SENSORS LIGHT CURTAINS Description MENU SETTING mode Setting item FIBER SENSORS 5th digit Response time 2.5 ms 5 ms 10 ms 25 ms 50 ms 100 ms 250 ms 500 ms 1,000 ms 5,000 ms 6th digit Unit switching MPa kPa kgf/cm2 bar psi mmHg inchHg - - - 7th digit Display refresh rate 250 ms 500 ms 1,000 ms - - - - - - - 8th digit ECO mode OFF STD FULL - - - - - - - Other Products DP-100 DP-M 679 FIBER SENSORS LASER SENSORS Dual Display Digital Pressure Sensor DP-100 SERIES DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from our website. DP-10 Sensor PHOTOELECTRIC SENSORS 30 1.181 MICRO PHOTOELECTRIC SENSORS 25.5 1.004 42.5 1.673 20 0.787 7.5 9.5 0.295 0.374 Connector AREA SENSORS 12 0.472 20 0.787 30 1.181 LIGHT CURTAINS PRESSURE / FLOW SENSORS R (PT) 1/8 male thread (North America: NPT 1/8) 1.5 0.059 INDUCTIVE PROXIMITY SENSORS Europe PARTICULAR USE SENSORS M5 female thread M3 female thread, 4 0.157 deep Europe 10 7 0.394 0.276 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS 14 0.551 G 1/8 male thread WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES DP-10-M(-P) Sensor 30 1.181 ENDOSCOPE LASER MARKERS PLC / TERMINALS o8.3 o0.327 ENERGY CONSUMPTION VISUALIZATION COMPONENTS MACHINE VISION SYSTEMS 4.5 0.177 30 1.181 HUMAN MACHINE INTERFACES FA COMPONENTS 20 0.787 30 1.181 25.5 1.004 connector M3 female thread, 4 0.157 deep 1.5 0.059 M5 female thread, 4 0.157 deep DP-11-E-P-J UV CURING SYSTEMS Sensor 30 1.181 25.5 1.004 47.5 1.870 20 0.787 7 0.276 9.5 0.374 30 1.181 Selection Guide Pressure/ Digital Display 20 0.787 4.5 0.177 Pressure/ Head-separated 1.5 0.059 Other Products 15 0.591 CN-14A-C CN-14A-R-C DP-M 14 0.551 M3 female thread, 4 0.157 deep 7 0.276 Connector attached cable (Optional, CN-14A-C2 is attached to the sensor) * Length L L 35 1.378 M8 connector M5 female thread G 1/8 male thread Flow DP-100 20 0.787 50 0.969 Model No. 8 0.315 8 0.315 o3.7 o0.146 cable Length L CN-14A(-R)-C1 1,000 39.370 CN-14A(-R)-C2 2,000 78.740 CN-14A(-R)-C3 3,000 118.110 CN-14A(-R)-C5 5,000 196.850 Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) Sensor mounting bracket (Optional) o2.3 o0.091 9.5 14.5 0.571 0.374 22 0.866 22 0.866 30 1.181 20 0.787 13 0.512 5.3 (0.209 ) R13 20 0.787 R0.512 5.5 0.217 20 0.787 AREA SENSORS 14.5 0.571 4.2 0.165 2-o3.5 o0.138 LIGHT CURTAINS 25.5 1.004 42.5 1.673 45 1.772 30 1.181 45 1.772 INDUCTIVE PROXIMITY SENSORS 12 0.472 30 1.181 15 0.591 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M3 (length 6 mm 0.236 in) screws with washers are attached. PRESSURE / FLOW SENSORS 9.5 0.374 7.5 0.295 44 1.732 SIMPLE WIRE-SAVING UNITS t2 t 0.079 MS-DP1-5 Sensor mounting bracket (Optional) STATIC CONTROL DEVICES R6.75 R0.266 ENDOSCOPE 29.5 1.161 20 0.787 4.5 0.177 16 0.630 o4.5 o0.177 8.5 0.335 13.5 0.531 20 0.787 LASER MARKERS 28 1.102 PLC / TERMINALS 30 1.181 4.5 0.177 44.5 30 1.752 1.181 20 0.787 HUMAN MACHINE INTERFACES 49.5 (1.949 ) o4.5 o0.177 20 0.787 29.5 1.161 30 1.181 MS-DP1-2MS-DP1-3 ENERGY CONSUMPTION VISUALIZATION COMPONENTS o8.3 o0.327 20 49.5 0.787 28.5 1.949 1.122 t 1.5 t 0.059 2-o3.5 o0.138 Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) Two M3 (length 6 mm 0.236 in) screws with washers are attached. 1.5 0.059 4.5 0.177 FA COMPONENTS 28 1.102 MACHINE VISION SYSTEMS t 1.5 t0.059 53.5 2.106 UV CURING SYSTEMS Panel mounting bracket (Optional), Front protection cover (Optional) Assembly dimensions Mounting drawing with DP-10 Panel cut-out dimensions Selection Guide When 1 unit is installed Pressure/ Digital Display Pressure/ Head-separated 0 31 -0.4 0 1.220 -0.016 39.3 ( 1.547 ) 34.5 1.358 ( WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Assembly dimensions Mounting drawing with DP-10-M 34.5 20 1.358 0.787 PARTICULAR USE SENSORS SENSOR OPTIONS 1.5 0.059 30 1.181 22.75 0.896 LASER SENSORS MICRO PHOTOELECTRIC SENSORS 2-R2.1 R0.083 9.5 0.374 2-R2.1 R0.083 FIBER SENSORS PHOTOELECTRIC SENSORS Assembly dimensions Mounting drawing with DP-10 1 0.039 4.2 0.165 680 The CAD data in the dimensions can be downloaded from our website. MS-DP1-1 t2 t 0.079 DP-100 SERIES 7.2 0.283 11 0.433 18.3 7.5 0.720 0.295 Front protection cover ) 50 1.969 33.4 1.315 8.7 0.343 Flow Other Products 0 31 -0.4 0 1.220 -0.016 9.5 0.374 When "n" units are installed horizontally in series When "n" units are installed vertically in series 0 12 0.472 R(PT) 1/ 8 male thread Panel thickness dimension 1 to 6 mm 0.039 to 0.236 in 31 -0.4 0 1.220 -0.016 31 1.220 x n + 3.5 0.138 x (n-1) 0 31 -0.4 0 1.220 -0.016 55 2.165 or more 31 1.220 x n + 3.5 0.138 x (n-1) Connector 33.4 1.315 M5 female thread, 4 0.157 deep (52 2.047 max) View A M3 female thread, 4 0.157 deep Material: POM (Panel mounting bracket) Polycarbonate (Front protection cover) 55 2.165 or more Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. DP-100 DP-M 681 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) ( 42.7 1.681 40 1.575 30 1.181 ) ( Panel cut-out dimensions 9.7 0.382 36 1.417 26.5 1.043 6.5 0.256 3 0.118 ) 56 2.205 36 +0.5 0 1.417 +0.020 0 Panel mounting bracket body Front protection cover (DPX-04) 8 0.315 Panel thickness dimension 1 to 3.2 mm 0.039 to 0.126 in Panel mounting bracket MS-DP1-7 MEASUREMENT SENSORS M5 female thread 80 3.150 36 +0.5 0 1.417 +0.020 0 Spacer Note: The panel tickness should be 1 to 32 mm 0.039 to 1.260 in. Material: Panel mounting bracket body *** Nylon 6 Panel mounting bracket *** Stainless steel (SUS304) Spacer *** Cold rolled carbon steel (SPCC)(Uni-chrome plated) SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Connector R 1/ 8 male thread 12 0.472 42.7 1.681 40 30 1.575 1.181 PARTICULAR USE SENSORS SENSOR OPTIONS Panel mounting bracket (Optional) Assembly dimensions Mounting drawing with DP-10 LIGHT CURTAINS INDUCTIVE PROXIMITY SENSORS The CAD data in the dimensions can be downloaded from our website. MS-DP1-4 AREA SENSORS PRESSURE / FLOW SENSORS DP-100 SERIES Conversion bushing (Optional) 15.8 0.622 STATIC CONTROL DEVICES ENDOSCOPE LASER MARKERS PLC / TERMINALS HUMAN MACHINE INTERFACES ENERGY CONSUMPTION VISUALIZATION COMPONENTS 14 0.551 3.5 0.138 0.5 ( 0.020 ) 11 0.433 7.8 0.307 M5 male thread Gasket 8 0.315 10 0.394 Rc1/8 female thread FA COMPONENTS Material: Brass (Nickel plated) Weight: 10 g approx. MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide MS-DP1-FM Assembly dimensions Mounting drawing with DP-10-M Pressure/ Digital Display 44.5 (1.752 ) 24 (0.945 ) Pressure/ Head-separated Flow Other Products DP-100 Flat attachment (Optional) 30 1.181 44.5 1.752 DP-M 2-o4.3 o0.169 20 0.787 24 0.945 30 1.181 52.5 ( 2.067 ) 24 (0.945 ) 37 1.457 11.5 0.453 24 0.945 8.5 0.335 37 1.457 11.5 0.453 11 0.433 30 1.181 52.5 2.067 24 0.945 6.5 0.256 5.5 0.217 13.5 0.531 17.5 0.689 M5 female thread Flat attachment (Optional) Assembly dimensions Mounting drawing with DP-10-M 11 0.433 6.5 0.256 5.5 0.217 MS-DP1-FR/FN/FE Material: Enclosure***Polybutylene terephthalate (PBT) (Glass fiber reinforced) Pressure port***Stainless steel (SUS303) O-ring***Hydrogenated Nitrile Butadiene Rubber (H-NBR) Weight: 15 g approx. (flat attachment only) Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. 2-o4.3 o0.169 14 0.551 20 0.787 24 0.945 30 1.181 Product distinguishing mark MS-DP1-FR: 0 line MS-DP1-FN: 1 line MS-DP1-FE: 2 line 17.5 0.689 8.5 0.335 Pressure port G1/8 female thread (Note) Material: Enclosure***Polybutylene terephthalate (PBT) (Glass fiber reinforced) Pressure port***Stainless steel (SUS303) O-ring***Hydrogenated Nitrile Butadiene Rubber (H-NBR) Weight: 25 g approx. (flat attachment only) Note: MS-DP1-FR has a Rc1/8 female thread. MS-DP1-FN has a NPT1/8 female thread. Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. 682 MEMO