BCD20008-G Rev AC, 26-Nov-2012 Page 1 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Features
RoHS lead-free-solder and lead-solder-exempted
products are available.
Wide input voltage ranges up to 150 VDC
1 or 2 isolated outputs up to 48 V
1200 to 3000 VAC I/O electric strength test
Emissions EN 55022 level A
Immunity to IEC/EN 61000-4-2,-3,-4,-5, and -6
High efficiency (typ. 86%)
Input undervoltage lockout
Shutdown input, adjustable output voltages
Flex power: Flexible load distribution on outputs
Outputs no-load, overload, and short-circuit proof
Operating ambient temperature –40 to 85 °C
Thermal protection
2" x 1.6" case with 10.5 mm profile
Supplementary insulation: 20/40IMX15 models
Double or reinforced insulation: 110IMY15 models
Description
The IMX15, IMS15, and IMY15 Series of board mountable 15-
Watt DC-DC converters have been designed according to the
latest industry requirements and standards. The converters
are particularly suitable for use in mobile or stationary
applications in transport, railways, industry, or telecommu-
nications, where variable input voltages or high transient
voltages are prevalent.
Covering a total input voltage range from 8.4 up to 150 V with
different models, the converters are available with single and
electrically-isolated double outputs from 3.3 up to 48 V,
externally adjustable, with flexible load distribution on double-
output models. A shutdown input allows for remote on/off.
Features include efficient input and output filtering and
consistently high efficiency over the entire input voltage range,
high reliability, and excellent dynamic response to load and
line changes.
The converters have been approved by CSA. 20IMS/20IMX15
and 40IMS/40IMX15 models provide supplementary in-
sulation. Connected to a secondary circuit, these models
provide SELV outputs, even if the bus voltage at the converter
input exceeds the SELV-limit of 60 VDC. The 110IMY15
models provide double insulation and are CE marked. They
may be connected to a rectified 110 VAC source without any
further isolation barrier.
The circuitry is comprised of integrated planar magnetics. All
components are automatically assembled and solidly soldered
onto a single PCB without any wire connection. Magnetic
feedback ensures maximum reliability and repeatability in the
control loop over all operating conditions. Careful con-
sideration of possible thermal stress ensures the absence of
hot spots providing long life in environments, where
temperature cycles are frequent. The thermal design allows
operation at full load up to an ambient temperature of 71 °C in
free air without using any potting material. For extremely high
vibration environments the case has holes for screw mounting.
Table of Contents Page Page
51
2.0"
40.6
1.6"
10.5
0.42"
Description ........................................................................... 1
Model Selection ................................................................... 2
Functional Description ......................................................... 4
Electrical Input Data ............................................................. 5
Electrical Output Data .......................................................... 8
Auxiliary Functions ............................................................. 13
Electromagnetic Compatibility (EMC) ................................ 14
Immunity to Environmental Conditions .............................. 16
Mechanical Data ................................................................ 17
Safety and Installation Instructions .................................... 18
Description of Options ...................................................... 19
Safety-approved to IEC 60950-1 and UL/CSA 60950 -1
2nd Edition
1 110IMY15
models
1
®
BCD20008-G Rev AC, 26-Nov-2012 Page 2 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Model Selection
Table 1: Model Selection
Output 1 Output 2 Output Input voltage Efficiency Model Options 2
Vo nom Io nom 1 Vo nom Io nom 1 power Vi min to Vi max ηη
ηη
ηmin
6 ηη
ηη
ηtyp 6
[VDC] [A] [VDC] [A] Po nom [W] [VDC] [%] [%]
3.3 4.5 - - 14.9 8.4 to 36 580 82 20IMX15-03-8RG SR -9, i, Z, -G
3.3 4.0 - - 13.2 16.8 to 75 3 78 80 40IMX15-03-8R i, Z
3.3 4.5 - - 14.9 16.8 to 75 3 81 83 40IMX15-03-8RG SR -9, i, Z, -G
3.3 4.5 - - 14.9 50 to 150 4 80 82 110IMY15-03-8RG SR i, Z, -G
5.1 3.5 - - 17.5 8.4 to 36 583 86 20IMX15-05-8RG SR i, Z, -G
5.1 3.5 - - 17.5 16.8 to 75 3 85 87 40IMX15-05-8RG SR i, Z, -G
5.1 3.5 - - 17.5 50 to 150 4 79.5 82 110IMY15-05-8RG SR i, Z, -G
5.1 2.3 - - 11.7 8.4 to 36 582 84 20IMX15-05-8R -9, i, Z
5.1 2.7 - - 13.8 14 to 36 81.5 84 24IMS15-05-9R i, Z
5.1 2.5 - - 12.8 16.8 to 75 3 81.5 83 40IMX15-05-8R -9, i, Z
5.1 2.7 - - 13.8 36 to 75 82 83 48IMS15-05-9R i, Z
5.1 2.5 - - 12.8 50 to 150 4 78 81 110IMY15-05-8R i, Z
5.1 1.35 3.3 1.35 11.3 8.4 to 36 582 84 20IMX15-0503-8R -9, i, Z, G
5.1 1.6 3.3 1.6 13.5 14 to 36 81 83 24IMS15-0503-9R i, Z
5.1 1.5 3.3 1.5 12.6 16.8 to 75 3 82 84 40IMX15-0503-8R -9, i, Z, G
5.1 1.6 3.3 1.6 13.5 36 to 75 79 82 48IMS15-0503-9R i, Z
5.1 1.5 3.3 1.5 12.6 50 to 150 4 79 82 110IMY15-0503-8R i, Z, G
5 1.3 5 1.3 13.0 8.4 to 36 582 85 20IMX15-05-05-8 -9, i, R, Z, G
5 1.4 5 1.4 14.0 14 to 36 81 84 24IMS15-05-05-9 i, Z
5 1.4 5 1.4 14.0 16.8 to 75 3 81 84 40IMX15-05-05-8 -9, i, R, Z, G
5 1.4 5 1.4 14.0 36 to 75 81 83 48IMS15-05-05-9 i, Z
5 1.4 5 1.4 14.0 50 to 150 4 80 82 110IMY15-05-05-8 i, Z, G
12 0.65 12 0.65 15.6 8.4 to 36 583 86 20IMX15-12-12-8 -9, i, Z, G
12 0.7 12 0.7 16.8 14 to 36 83 86 24IMS15-12-12-9 i, Z
12 0.7 12 0.7 16.8 16.8 to 75 3 84 87 40IMX15-12-12-8 -9, i, R, Z, G
12 0.7 12 0.7 16.8 36 to 75 82 86 48IMS15-12-12-9 i, Z
12 0.7 12 0.7 16.8 50 to 150 4 82 85 110IMY15-12-12-8 i, Z, G
15 0.5 15 0.5 15.0 8.4 to 36 585 88 20IMX15-15-15-8 -9, i, R, Z, G
15 0.56 15 0.56 16.8 14 to 36 83 86 24IMS15-15-15-9 i, Z
15 0.56 15 0.56 16.8 16.8 to 75 3 83 86 40IMX15-15-15-8 -9, i, R, Z, G
15 0.56 15 0.56 16.8 36 to 75 84 86 48IMS15-15-15-9 i, Z
15 0.56 15 0.56 16.8 50 to 150 4 82 85 110IMY15-15-15-8 i, Z, G
24 0.32 24 0.32 15.4 8.4 to 36 583 86 20IMX15-24-24-8 -9, i, R, Z, G
24 0.35 24 0.35 16.8 14 to 36 84 87 24IMS15-24-24-9 i, Z
24 0.35 24 0.35 16.8 16.8 to 75 3 84 86 40IMX15-24-24-8 -9, i, R, Z, G
24 0.35 24 0.35 16.8 36 to 75 83 86 48IMS15-24-24-9 i, Z
24 0.35 24 0.35 16.8 50 to 150 4 82 85 110IMY15-24-24-8 i, Z, G
1Flexible load distribution on dual and double outputs possible; up to 75% of the total output power Po nom on one of the 2 outputs.
IMX/IMY15-0503 models have reduced load distribution flexibility; 1.8 A max. on one of the 2 outputs. The other output should not
exceed the difference to the total output power Po nom.
2See Description of Options.
3Short-time operation down to Vi = 14.4 V possible (Po reduced to approx. 85% of Po nom)
4Short-time operation down to Vi = 43.2 V possible (Po reduced to approx. 85% of Po nom) and up to 154 V
5Initial start-up at 9 V, main output voltage regulation down to 8.4 V
6Efficiency at TA = 25 °C, Vi nom, Io nom.
SR Models with synchronos rectifier. For the RoHS version of such models, add -G !
Preferred for new designs
NFND Not for new designs. Replace 24IMS15 models by 20IMX15 and 48IMS15 by 40IMX15;
Replace 20IMS15-05, 40IMS15-05, and 110IMY15 by models with with synchronos rectifier SR;
For new designs, chose the always the RoHS version.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 3 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
RoHS- Compliant Models
The type designation of RoHS-compliant models (compliant for the restriction of all six substances) for the IMX/IMY15 Series
ends with "G".
However, in single-output models with 3.3 V or 5.1 V output an extra hyphen (-) is added after the existing "G", which already
signifies a synchronous rectifier. This is an exception to Power-One's normal nomenclature to identify this type of product, since
G is already used to designate products for higher output current fitted with a synchronous rectifier. As an example
– 20IMX15-05-8R-G means a standard version with RoHS compliance for all six substances.
– 20IMX15-05-8RG means a synchronous rectifier version which is not RoHS-compliant.
– 20IMX15-05-8RG-G means a synchronous rectifier version and with RoHS compliance for all six substances.
– 20IMX15-05-05-8RG means a double-output model with RoHS compliance for all six substances
– 110IMY15-24-24-8RG means a double-output model with RoHS compliance for all six substances.
Part Number Description
40 IMX15 - 05 - 05 -8 R G i Z -G
xxix
Input voltage range Vi
8.4 to 36 V ................................................ 20
14 to 36 V ................................................. 24
16.8 to 75 V .............................................. 40
36 to 75 V ................................................. 48
50 to 150 V ............................................. 110
Series .............................................. IMX15, IMS15, IMY15
Output voltage of output 1 ...................... 03, 05, 12, 15, 24
Hyphen designating double-output models with two
electrically isolated outputs .......................................... - 1
Output voltage of output 2 ...................... 03, 05, 12, 15, 24
Operating ambient temperature range TA
–40
5 to 85 °C ............................................. -8
–40
5 to 71 °C ............................................. -9 2
Options and features:
R input and magnetic feedback ................. R 3
Synchronous rectification ........................... G
Inhibit ............................................................ i 4
Open frame .................................................. Z
RoHS compliant for all 6 substances ........ -G
1Not applicable to -0503 models.
2IMS15 models are not recommended for new designs.
3Standard for single-output and -0503- models, not for new designs of other models
4Option i excludes shutdown.
5Only –25 °C for -RG models
Note: The sequence of options must follow the order above.
Examples: 20 IM X15-05-05-8: DC-DC converter, input voltage 9 to 36 V, 2 galvanically isolated outputs each providing
5 V, 1.3 A.
110 IMY15-0503-8R: DC-DC converter, input voltage 50 to 150 V, 2 outputs with common return providing +5.1 V,
1.5 A and +3.3 V, 1.5 A. Converter fitted with magnetic feedback for tight output voltage regulation.
Product Marking
The converters without option Z are marked with basic type designation, input and output voltages and currents, applicable safety
approval and recognition marks, Power-One patent nos., company logo, date code, and serial number.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 4 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Functional Description
The IMX15/IMS15/IMY15 Series of DC-DC converters are
magnetic feedback-controlled flyback converters using current
mode PWM (Pulse Width Modulation). The -05- and -0503-
output voltage models, as well as all double-output models
fitted with option R, exhibit an active magnetic feedback loop
via a pulse transformer, resulting in very tight regulation of the
output voltage (see the block diagrams). The output voltages
of these models can be adjusted via the R input. The R input
is referenced to the secondary side and allows for
programming the output voltages in the range of
approximately 80 to 105% of Vo nom, using either an external
resistor or an external voltage source.
Several single-output models with 3.3 or 5.1 V output exhibit a
synchronos rectifier to improve the efficiency.
The voltage regulation on the double-output models without
option R is achieved with a passive transformer feedback
from the main transformer (see fig. 3). The output voltages
can be adjusted via the Trim input. The Trim input is
referenced to the primary side and allows for programming
the output voltage in the range 100 to 105% of Vo nom via an
external resistor or within 75 to 105% using an external
voltage source. The load regulation output characteristic
allows for paralleling of one or more double-output models
with equal output voltage.
Current limitation is provided by the primary circuit, thus
limiting the total output power of double-output models. The
shut-down input allows remote converter on/off.
Overtemperature protection will disable the converter under
excessive overload conditions with automatic restart.
Fig. 1
Block diagram of single-output models
Fig. 2
Block diagram of -0503-models
Fig. 3
Block diagram of double-output models
PWM
2 x 2200 pF
1500 V
1
2
13
15
Vi+
Vi
Vo+
Vo
03039
17 R
4
SD
PWM
2 x 2200 pF
1
2
3
4
13
15
12
11
Vi+
SD
Vi
Vo1+
Go
n.c. Vo2+
Go
03089
17
R
PWM
2 x 2200 pF
1
2
3
4
11
12
15
13
Vi+
SD
Vi
Vo1+
Vo1–
Trim Vo2+
Vo2–
03090
17 n.c.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 5 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Table 2a: Input data of IMX15 and IMY15 models
Input 20IMX 40IMX 110IMY Unit
Characteristics Conditions min typ max min typ max min typ max
ViInput voltage range
1TA minTA max 9 5 8 36 16.8 5 6 75 50 5 7 150 V
Vi nom Nominal input voltage Io = 0 – Io nom 20 40 110
Vi sur Repetitive surge voltage Abs. max input (3 s) 40 100 168
tstartup Converter Switch on Worst case condition at 0.25 0.5 0.25 0.5 0.5 0.7 s
start-up time 2 SD high Vi min, Io = Io nom 0.1 0.1 0.1
trise Rise time 2 Vi nom, resistive load 5 5 5 ms
Io nom, capac. load 10 20 10 20 10 20
Ii o No-load input current Io = 0, Vi min Vi max 65 45 15 mA
Iirr Reflected ripple current Io = 0 – Io nom 30 30 20 mApp
Iinr p Inrush peak current 3 Vi = Vi nom 8910A
CiInput capacitance for surge calculation 1.5 0.75 0.35 µF
VS
D
Shut-down voltage Converter disabled –10 to 0.7 –10 to 0.7 –10 to 0.7 V
Converter operating open or 2 – 20 open or 2 – 20 open or 2 – 20
RS
D
Shut-down input resistance approx. 10 approx. 10 approx. 10 k
IS
D
Input current, when Vi minVi max 10 3 1 mA
disabled SD connected to Vi–
fsSwitching frequency Vi minVi max, approx. 300 approx. 300 approx. 300 kHz
Io = 0 – Io nom
Vi RFI Input RFI level conducted EN 55022 4 AA A
1If Vo is set above Vo nom by use of the R or Trim input, Vi min will be proportionately increased.
2Measured with resistive and max. admissible capacitive load. Valid for models with rev. AI or greater.
3Source impedance according to ETS 300132-2, version 4.3.
4Measured with a ceramic capacitor Ci directly across input; output lead length 0.1 m, leads twisted. Double-output models with both
outputs in parallel. Ci is specified in table 11.
5Input undervoltage lockout at typ. 80% of Vi min.
6Short time operation down to Vi min >14.4 V possible. Po reduced to approx. 85% of Po nom.
7Short time operation down to Vi min >43.2 V possible. Po reduced to approx. 85% of Po nom.
8Initial start-up at Vi = 9 V, main output voltage regulation down to 8.4 V
Electrical Input Data
General conditions:
–T
A = 25 °C, unless TC is specified.
Shut-down pin left open-circuit.
Trim or R input left open-circuit.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 6 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Table 2b: Input Data of IMS15 models; general conditions as in table 2a
Input 24IMS 48IMS Unit
Characteristics Conditions min typ max min typ max
ViInput voltage range
1TA minTA max 14 36 36 75 V
Vi nom Nominal input voltage Io = 0 – Io nom 24 48
Vi sur Repetitive surge voltage Abs. max input (3 s) 50 100
tstartup Converter Switch on Worst case condition at 0.25 0.5 0.25 0.5 s
start-up time 2 SD high Vi min, Io = Io nom 0.1 0.1
trise Rise time 2 Vi nom, resistive load 5 5 ms
Io nom, capac. load 10 20 10 20
Ii o No-load input current Io = 0, Vi min Vi max 20 40 10 20 mA
Iirr Reflected ripple current Io = 0 – Io nom 30 30 mApp
Iinr p Inrush peak current 3 Vi = Vi nom 5 4.5 A
CiInput capacitance for surge calculation 4 2 µF
VS
D
Shut-down voltage Converter disabled –10 to 0.7 –10 to 0.7 V
Converter operating open or 2 – 20 open or 2 – 20
RS
D
Shut-down input resistance approx. 10 approx. 10 k
IS
D
Input current, when Vi min Vi max 1.2 3 1.2 3 mA
disabled SD connected to Vi–
fsSwitching frequency Vi minVi max, approx. 300 approx. 300 kHz
Io = 0 – Io nom
Vi RFI Input RFI level conducted EN 55022 4 AA
1If Vo is set above Vo nom by use of the R or Trim input, Vi min will be proportionately increased.
2Measured with resistive and max. admissible capacitive load.
3Source impedance according to ETS 300132-2, version 4.3.
4Measured with a ceramic capacitor Ci directly across input; output lead length 0.1 m, leads twisted. Double-output models with both
outputs in parallel. Ci is specified in table 11.
5Input undervoltage lockout at typ. 80% of Vi min.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 7 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Input Transient Voltage Protection
A built-in suppressor diode provides effective protection
against input transients, which typically occur in many
installations.
Table 5: Built-in transient voltage suppressor
Type Breakdown Peak power Peak pulse
voltage at 1 ms current
VBr nom [V] Pp [W] Ipp [A]
20IMX15 40 1500 22
24IMS15 53 600 7.7
40IMX15 100 1500 9.7
48IMS15 100 600 4.1
110IMY15 168 600 0.5
Fuse and Reverse Polarity Protection
The built-in suppressor diode also provides for reverse polarity
protection at the input by conducting current in the reverse
direction. An external fuse is required to limit this current.
Inrush Current
The inrush current has been made as low as possible by
choosing a very small input capacitance. A series resistor may
be installed in the input line to further reduce this current.
Fig. 4
Typical inrush current at Vi nom, P
o nom versus time
(40IMX15). Source impedance according to
ETS 300132-2 at Vi nom.
Fig. 5
Converter start-up and rise time
For very high energy transients as for example to achieve
compliance to IEC/EN 61000-4-5 or ETR 283 (see table
Electromagnetic Immunity), an external inductor and a
capacitor are required, see Fig. 6. The components should
have similar characteristics as listed in table 6.
Fig. 6
Example for external circuitry to achieve better transient
immunity. The diode D is only necessary for 20IMX15
models.
Table 6:
Components for external circuitry for IEC/EN 61000-4-5,
level 3, or ETR 283 (19Pfl1) compliance.
Model Inductor (L) Capacitor (C) Diode (D)
20IMX15 68 µH, 2.7 A 330 µF, 63 V 1.5 k E47A
24IMS15 150 µH, 1.3 A 150 µF, 63 V -
40IMX15 220 µH, 1.3 A 2 x 100 µF, 100 V -
48IMS15 150 µH, 1 A 100 µF, 100 V -
110IMY15 330 µH, 0.4 A 2 x 100 µF, 200 V -
Table 4: Recommended external fuses
Model Fuse type
20IMX15 F 4.0 A
24IMS15 F 3.15 A
40IMX15, 48IMS15 F 2.0 A
110IMY15 F 1.0 A
V
o nom
V
o
t
startup
t
rise
t
04008b
Input Undervoltage Lockout
A special feature of these converters is the accurate
undervoltage lockout protection, which protects against large
currents caused by operation at low voltages. This ensures
easier start-up in distributed power systems.
Tab. 3: Turn on and turn off voltage
Model Turn on Turn off Unit
min max min max
20IMX15 7.5 8 7 7.5 V
24IMS15 12.5 13.5 12 13
40IMX15 12.5 13.5 12 13
48IMS15 31.5 32.5 31 32
110IMY15 40 42.5 38 40.5
Vi+
Vi–
C
L
D
+
04036a
t
04022b
020 40 60 80 100 µs
4
3
2
1
A
®
BCD20008-G Rev AC, 26-Nov-2012 Page 8 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Electrical Output Data
We recommend connecting an external 1 µF ceramic capacitor across the output pins.
General conditions:
– TA = 25°C, unless TC is specified
– Shutdown pin and Trim or R pin left open-circuit (not connected)
Table 7a: Output data for single-output models -03-8RG
1 and 05-8RG
1
Output 3.3 V 5.1 V Unit
Characteristics Conditions min typ max min typ max
VoOutput voltage Vi nom 3.25 3.35 5.05 5.15 V
Io = 0.5 Io nom
Io nom Output current 20IMX Vi min to Vi max 4.5 3.5 A
40IMX /110IMY 4.5 3.5
Io L Current limit 2 Vi nom, TC = 25 °C 6.0 4.6
Vo 93% Vo nom
VoLine/load regulation Vi min to Vi max, ±0.5 ±0.5 %
(0.1 to 1) Io nom
VoOutput voltage noise Vi min to Vi max 4100 100 mVpp
Io = Io nom 560 60
Vo L Output overvoltage limit. 3 115 130 115 130 %
Co ext Admissible capacitive load 0 4000 0 4000 µF
Vo d Dynamic Voltage deviat. Vi nom ±250 ±250 mV
tdload Recovery time Io nom 1/2 Io nom 11ms
regulation IEC/EN 61204
αVo Temperature coefficient Vi min to Vi max ±0.02 ±0.02 %/K
Vo/TC(0.1 to 1) Io nom
1All models -RG (synchronous rectifier) have a minimum case and operating temperature of –25 °C.
2The current limit is primary side controlled. In the event of a sustained overload condition the thermal protection may cause the
converter to shut down (restart after cooling down).
3The overvoltage protection is via a primary side second regulation loop. It is not tracking with R control.
4BW = 20 MHz
5Measured with a probe according to EN 61204
®
BCD20008-G Rev AC, 26-Nov-2012 Page 9 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Table 7b: Output data for -05-8R and -0503-8R models; general conditions as in table 7a
Output 5.1 V 5.1/3.3 V Unit
Characteristics Conditions min typ max min typ max
Vo, Vo1 Output voltage Vi nom 5.05 5.15 5.0 5.12 V
Vo2 Io = 0.5 Io nom 3.13 3.46
Io nom Output current 1 20IMX Vi minVi max 2.3 2 × 1.35 1.6 4 A
24IMS/48IMS 2.7 2 × 1.6 2.0 4
40IMX/110IMY 2.5 2 × 1.5 1.8 4
IoL, Io1L Current limit 2 20IMX Vi nom 3.2 2.7
Io2L Vo1 93% Vo nom 3.8
IoL, Io1L 24IMS/48IMS 3.5 3.0
Io2L 3.8
IoL/Io1L 40IMX/110IMY 3.6 2.9
Io2L 4.0
VoLine/load regulation 5.1 V Vi minVi max, ±0.5 %
5.1 V (0.1 – 1) Io nom –+3,5
3.3 V ±4.5
Vo1/2 Output voltage noise Vi minVi max 570 80 mVpp
Io = Io nom 640 40
Vo L Output overvoltage limit 7 115 130 115 130 %
Co ext Admissible capacitive load 0 4000 0 4000 3 µF
Vo d Dynamic Voltage deviat. Vi nom ±250 ±150 mV
tdload Recovery time Io nom 1/2 Io nom 11ms
regulation IEC/EN 61204
αVo Temperature coefficient Vi minVi max ±0.02 ±0.02 %/K
Vo/TC(0.1 – 1) Io nom
1Flexible load distribution: Io max for one of the 2 outputs; however the total load should not exceed Po nom specified in the table Model
Selection.
2The current limit is primary-side controlled.
3For -0503-models: total capacitive load of both outputs.
4For -0503-models: Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom.
5BW = 20 MHz
6Measured with a probe according to EN 61204
7The overvoltage protection is via a primary side second regulation loop. It is not tracking with R control.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 10 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Table 7c: Output data for double-output models; general conditions as in table 7a
Output 2 ××
××
× 5 V 2 ××
××
× 12 V 2 ××
××
× 15 V 2 ××
××
× 24 V Unit
Characteristics Conditions min typ max min typ max min typ max min typ max
Vo1 Output 1 24IMS/48IMS Vi nom 4.95 5.05 11.88 12.12 14.85 15.15 23.70 24.30 V
other models Io = 0.5 Io nom 4.95 5.05 11.90 12.10 14.88 15.12 23.80 24.20
Vo2 Output 2 24IMS/48IMS 4.94 5.06 11.84 12.16 14.80 15.20 23.64 24.36
other models 4.94 5.06 11.88 12.12 14.85 15.15 23.75 24.25
Io nom Output current 1 20IMX Vi minVi max 2 ××
××
× 1.3 2 ××
××
× 0.65 2
××
××
× 0.50 2 ××
××
× 0.32 A
other models 2 ××
××
× 1.4 2 ××
××
× 0.70 2 ××
××
× 0.56 2 ××
××
× 0.35
IoL Current limit 2, 4 20IMX Vi nom 3.0 1.6 1.3 0.85
24IMS/48IMS Vo1 93% Vo nom 3.5 1.9 1.6 0.95
40IMX/110IMY 3.2 1.7 1.4 0.90
Vo1 Line/load regulation output 1 Vi minVi max, Io nom ±1 ±1 ±1 ±1 %
Vo2 output 2 Vi nom, (0.1 – 1) Io nom ±3 ±3 ±3 ±3
Vo1/2 Output voltage noise Vi minVi max 580 120 150 240 mVpp
Io = Io nom 640 60 70 120
Vo L Output overvoltage limit 7 Min. load 1% 115 130 115 130 115 130 115 130 %
Co ext Admissible capacitive load 3 0 4000 0 680 0 470 0 180 µF
Vo d Dynamic Voltage deviat. Vi nom ±250 ±300 ±300 ±600 mV
tdload Recovery time Io nom 1/2 Io nom 11 1 1ms
regulation
αUo Temperature coefficient Vi minVi max ±0.02 ±0.02 ±0.02 ±0.02 %/K
Vo/TC(0.1 – 1) Io nom
1Flexible load distribution: Each output of double-output models is capable of delivering 75% of the total output power; however the
total load should not exceed Po nom specified in the table Model Selection.
2The current limit is primary-side controlled.
3Measured with both outputs connected in parallel.
4Conditions for specified output. Other output loaded with constant current Io = 0.5 Io nom.
5BW = 20 MHz
6Measured with a probe according to EN 61204
7The overvoltage protection is via a primary side second regulation loop, not tracking with Trim or R control.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 11 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Thermal Considerations
If a converter, mounted on a PCB, is located in free, quasi-
stationary air (convection cooling) at the indicated maximum
ambient temperature TA max (see table Temperature
specifications) and is operated at its nominal input voltage and
output power, the case temperature measured at the
measuring point of case temperature TC (see Mechanical
Data) will approach the indicated value TC max after the warm-
up phase. However, the relationship between TA and TC
depends heavily on the conditions of operation and integration
into a system. The thermal conditions are influenced by input
voltage, output current, airflow, temperature of surrounding
components and surfaces, and the properties of the printed
circuit board. TA max is therefore only an indicative value.
Caution: The case temperature TC measured at the measuring
point of case temperature TC (see Mechanical Data) may under no
circumstances exceed the specified maximum value. The installer
must ensure that under all operating conditions TC remains within
the limits stated in the table Temperature specifications.
Overtemperature Protection
The converters are protected from possible overheating by
means of an internal temperature monitoring circuit. It shuts
down the converter above the internal temperature limit, and
attempts to automatically restart in short intervals. This feature
helps protect against excessive internal temperatures, which
could occur during heavy overload conditions.
Output Overvoltage Protection
The output of single-output models as well as -0503- and -05-
05-models are protected against overvoltage by a second
control loop. In the event of an overvoltage on one of the
outputs, the converter will shut down and attempt to restart in
short intervals.
Doublel-output models (except -0503- and -05-05-models) are
protected against overvoltage by a Zener diode across the
second output. Under worst case conditions the Zener diode
will become a short circuit. Since with double-output models
both outputs track each other, the protection diode is only
provided in one of the outputs. The main purpose of this
feature is to protect against possible overvoltage, which could
occur due to a failure in the control logic. This protection circuit
is not designed to withstand externally applied overvoltages.
Fig. 9
Vo versus Io (typ) of converters with Vo = 5.1 V
(110IMY15-05-8R)
5.5
5.0
4.5
4.0
3.5
3.0
0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4
A
V
05166a
Fig. 8
Overload switch-off (hiccup mode); typical values
70
100
V
o
[%]
t
05041b
0.3 s
overload short-circuit condition
switch-off
0
1.0
0.8
0.6
0.4
0
0.2
20
40 60 80
100 °C
Po/Po max
JM017
T
A
0.5 m/s
=
100 LFM
natural cooling
Short Circuit Behaviour
The current limit characteristic shuts down the converter,
whenever a short circuit is applied to its output. It acts self-
protecting, and automatically recovers after removal of the
overload condition (hiccup mode).
Parallel and Series Connection
The outputs of one or several single- or double-output
Fig. 7
Maximum output power versus ambient temperature
models can be connected in series without any precautions,
taking into consideration that the highest output voltage
should remain below 42 V to ensure that the output remains
SELV.
Both outputs of the same converter with equal voltage (e.g. 5 V
/ 5 V) can be connected in parallel and will share their output
currents equally. Parallel operation of single or double
outputs of two or more converters with the same output
voltage may cause start-up problems at initial start-up. This is
only advisable in applications, where one converter is able to
deliver the full load current as, for example, required in true
redundant systems.
Note: If the 2nd output of double-output models (except 0503) is not
used, connect it in parallel to the 1st output.
Typical Performance Curves
General conditions:
– TA = 25 ºC, unless TC is specified.
– Shutdown pin left open-circuit.
– Trim or R input not connected.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 12 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Fig. 10
Vo versus Io (typ.) of double-output models (2 x 12 V), with
both outputs in parallel (110IMY15-12-12-8)
7
8
9
10
11
12
13
V
0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 A
I
o
0
05020a
Fig. 12a
Efficiency versus input voltage and load. Typical values
(40IMX15-12-12-8).
Fig. 11
Cross load regulation Vo1 versus Io1 (typ.) for various Io2
(2 x 12 V).
Fig. 13
Flexible load distribution on double-outputs models with
option R (110IMY15-12-12-8R):
Load variation from 0 to 150% of Io1 nom on output 1;
output 2 loaded with 50% of Io2 nom.
Fig. 12b
Efficiency versus input voltage and load. Typical values
(110IMY15-12-12-8)
11
11.5
12
12.5
13
13.5
V
0.2 0.3 0.4 0.5 0.6 0.7 A
I
o1
0.1
05021a
I
o2
= 0.35 A
I
o2
= 0.035 A
60
70
80
90
%
0.5 0.75 1 P
o
/P
o nom
0.25
05167a
V
i min
V
i nom
V
i max
60
70
80
90
%
0.5 0.75
0.25
05168a
V
i min
V
i nom
V
i max
1 P
o
/P
o no
m
Fig. 12c
Efficiency versus input voltage and load. Typical values
(48IMS15-12-12-9)
50
60
70
80
90
%
05040a
0.25 0.5 0.75 1 I
o1
/I
o1 nom
V
i nom
V
i max
V
i min
V
I
o1
/I
o1 nom
05039-X15b
14
13
12
11
10 0 0.25 0.5 0.75 11.5
V
o2
V
o1
1.25
®
BCD20008-G Rev AC, 26-Nov-2012 Page 13 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Table 8: Vo versus Vext approximate values
Vo nom Typ. values of Rext1 Typ. values of Rext2
[V] Vo [% of Vo nom] R
ext1 [k
]Vo [% of Vo nom] R
ext2 [k
]
3.3 90 0.47 100
95 2.7 105 15
100 110 6.8
5.1 90 3.3 100
95 8.2 105 9.1
100 110 3.9
Auxiliary Functions
Shutdown Function
The outputs of the converters may be enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied to the shut-
down pin. If this function is not required, the shut-down pin
should be left open-circuit.
Converter operating: 2.0 to 20 V
Converter disabled: –10 to +0.7 V
Adjustable Output Voltage
R input for single-output models and -0503-models
Trim input for double-output models
R input as option R for most double-output models.
As a standard feature, the single- and double-output models
offer adjustable output voltage(s) by using the control input R
or Trim. If the control input is left open-circuit, the output
voltage is set to Vo nom. For output voltages Vo > Vo nom, the
minimum input voltage Vi min (see Electrical Input Data)
increases proportionally to Vo/Vo nom.
Single-output models with synchronous rectifier (G):
The R input is referenced to the secondary side of the
converter. Adjustment of the output voltage is possible by
means of an external resistor connected between the R pin
and either Vo+ or Vo–.
Note: For models with synchronous rectifier the logic for Vo
adjustment differs from other models with R input.
Double-output models with Trim input:
The Trim input is referenced to the primary side. The figure
below shows the topology. Adjustment is possible trough either
an external resistor or an external voltage source Vext.
Fig. 16
Output voltage control for double-output models (without
option R) by means of the Trim input.
Fig. 15
Output voltage control for single-output models, -0503-
models, and double-output models fitted with option R by
means of the R input.
All other models fitted with R-input:
The R input is referenced to the secondary side of the
converter. Adjustment of the output voltage is possible by
means of either an external resistor or a voltage source.
Fig. 14
Output voltage control for single-output models with
synchronous rectifier.
a) Adjustment by means of an external resistor Rext.
Depending upon the value of the required output voltage,
the resistor shall be connected:
either: Between the R pin and Vo– to achieve an output
voltage adjustment range of Vo 80 to 100 % of Vo nom.
Vo
Rext1 4 k • –––––––––
Vo nomVo
or: Between the R pin and Vo+ to achieve an output voltage
range of Vo 100 to 105% of Vo nom.
(Vo – 2.5V)
Rext2 4 k––––––––––––––––––
2.5 V • (Vo/Vo nom – 1)
b) Adjustment by means of an external voltage Vext
between Vo– and R pin.
The control voltage range is 1.96 to 2.62 V and allows for
adjustment in the range of Vo 80 to 105% of Vo nom.
Vo • 2.5 V
Vext ––––––––
Vo nom
Attempting to adjust the output below this range will cause
the converter to shut down (hiccup mode).
Note: Applying an external control voltage >2.75 V may damage
the converter.
R
Vo+
Vo–
Vi+
Vi–
Rext2
Rext1
06131
Trim
Vo1+
Vo2–
+
Vext
Vi+
Vi–
Rext
Vo1–
Vo2+
06089a
Control
circuit
Vref 2.5 V
R
Vo+
Vo–
+
V
ex
t
4 k
V
ref
= 2.5 V
Control
logic R
ext1
R
ext2
06029e
Vi–
Vi+
+
®
BCD20008-G Rev AC, 26-Nov-2012 Page 14 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Table 9b: Vo versus Vext for Vo = 75 to 105% Vo nom;
typical values (Vi nom, Io1/2 = 0.5 Io1/2 nom)
Vo [% Vo nom]Vext [V]
105 0
102 1.6
95 4.5
85 9
75 13
Table 9a: Rext for Vo > Vo nom;
approximate values (Vi nom, Io1, 2 = 0.5 Io1/2 nom )
Vo [% Vo nom]Rext [k
]
105 to 108 (107 typically) 0
105 1.5
104 5.6
103 12
102 27
101 68
100
a) Adjustment by means of an external resistor Rext:
Programming of the output voltage by means of an external
resistor Rext is possible within 100 to 105% of Vo nom. Rext
should be connected between the Trim pin and Vi–.
Connection of Rext to Vi+ may damage the converter. The
table below indicates suitable resistor values for typical
output voltages under nominal conditions (Vi nom, Io = 0.5
Io nom) with either parallel-connected outputs or equal-load
conditions on both outputs.
b) Adjustment by an external voltage source Vext:
For programming the output voltage in the range 75 to
105% of Vo nom, a source Vext (0 to 20 V) is required,
connected between the Trim pin and Vi–. The table below
indicates values Vo versus Vext (nominal conditions Vi nom, Io
= 0.5 Io nom), with either parallel-connected outputs or equal
load conditions on both outputs. Applying a control voltage
>20 V will set the converter into a hiccup mode. Direct
paralleling of the Trim pins of parallel connected converters
is possible.
typically occur in many installations, but especially in battery-
driven mobile applications.
Electromagnetic Compatibility (EMC)
A suppressor diode together with an input filter forms an
effective protection against high input transient voltages, which
Table 10: Immunity type tests
Phenomenon Standard Class Coupling Value Waveform Source Test In Perf.
Level mode 2 applied Imped. procedure oper. crit. 3
Electrostatic IEC/EN 2 contact discharge 4000 Vp1/50 ns 330 10 positive and yes B
discharge 61000-4-2 (R pin open) 10 negative
to case 3 air discharge 8000 Vpdischarges
(R pin open)
Electromagnetic IEC/EN x 5 antenna 20 V/m 5 AM 80% n.a. 80 to 1000 MHz yes A
field 61000-4-3 3 6 3 V/m 6 1 kHz
ENV 50204 3 antenna 10 V/m PM, 50% duty n.a. 900 MHz yes A
cycle, 200 Hz
repetition frequ.
Electrical fast IEC/EN 3 4 direct +i/–i 2000 Vp 4 bursts of 5/50 ns 50 60 s positive yes A
transients/burst 61000-4-4 5 kHz rep. rate 60 s negative
transients with transients per
15 ms burst coupling mode
duration and a
300 ms period
Surges IEC/EN 2 +i /i 1000 Vp1.2/50 µs 2 5 pos. and 5 neg. yes B
61000-4-5 3 1 2000 Vp 1 surges
RF conducted IEC/EN 3 +i /i 10 VAC AM modulated 150 0.15 to 80 MHz yes A
immunity 61000-4-6 2 6 3 VAC 6 80%, 1 kHz
1External components required; see Fig. 6 and table 6.
2i = input, o = output.
3A = normal operation, no deviation from specs., B = temporary deviation from specs. possible.
4Corresponds to the railway standard EN 50121-3-2:2006, table 9.3.
5Corresponds to the railway standard EN 50121-3-2:2006, table 9.1.
6Valid for 24IMS15 and 48IMS15
Electromagnetic Immunity
®
BCD20008-G Rev AC, 26-Nov-2012 Page 15 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
20IMX15-12-12-8 Peak
PMM 8000 PLUS
Name: 20d12_1
Date: 24.04.06 Time: 16:23
20IMX15D12-con-p
EN 55022 A
dbµV
80
60
20
40
0
0.2 0.5 1 2 5 10 20 MHz
Fig. 19
Example for external circuitry to comply with EN 55011/ EN
55022, Class B, conducted.
This filter was designed for a 40IMX15-12-12-8. All
capacitors are rated to 100 V, the chokes to 1.5 A.
Conducted Emissions
Fig. 17a
Typ. disturbance voltage (peak) at pos. input according to EN
55011/022, measured at Vi nom and Io nom. Output leads 0.1 m,
twisted, input capacitors see table 11 (20IMX15-12-12-8)
Fig. 17c
Typ. disturbance voltage (peak) at pos. input according to EN
55011/022, measured at Vi nom and Io nom.
Output leads 0.1 m, twisted, input capacitors see table 11
(110IMY15-12-12-8)
Fig. 17b
Typ. disturbance voltage (peak) at pos. input according to EN
55011/022, measured at Vi nom and Io nom. Output leads 0.1 m,
twisted, input capacitors see table 11 (40IMX15-12-12-8)
Table 11: External capacitors across the input to comply with
EN 55011/EN 55022, Class A, conducted; see fig. 17a, b, c
Model Ceramic ML Electrolytic capacitor
20IMX15, 24IMS15 0.47 µF/50 V 220 µF/50 V
40IMX15, 48IMS15 0.33 µF/100 V 220 µF/100 V
110IMY15 0.15 µF/ 200 V 4.7 µF/200 V
Fig. 18
Typ. disturbance voltage (peak) at input according to EN
55011/022, measured at Vi nom and Io nom. Output leads 0.1 m,
twisted, input filter as in fig. 19 (40IMX15-12-12-8)
40IMX15-12-12-8-Peak
PMM 8000 PLUS
Name: 40d12_4
Date: 02.05.06 Time: 09:58
EN 55022 B
dbµV
60
20
40
0
40IMX15D12-F
0.2 0.5 1 2 5 10 20 MHz
40IMX15-12-12-8 Peak
PMM 8000 PLUS
Name: 40d12_1
Date: 24.04.06 Time: 15:2
40IMX15D12-con-p
EN 55022 A
dbµV
80
60
20
40
0
0.2 0.5 1 2 5 10 20 MHz
dbµV
80
60
20
40
0
110IMY15-12-12-9 Peak
PMM 8000 PLUS
Name: 110d12_1
Date: 25.04.06 Time: 08:07
0.2 0.5 1 2 5 10 20 MH
z
110IMY15-D12-con-p
EN 55022 A
40IMX15
22 µH
22 nF 47 µF 330 nF
47 µF
Vi+
Vi–
JM126
®
BCD20008-G Rev AC, 26-Nov-2012 Page 16 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Temperatures
Table 14: Temperature specifications
Valid for air pressure of 800 to 1200 hPa (800 to 1200 mbar)
Temperature -9 -8 Unit
Characteristics Conditions min max min max
TAAmbient temperature Operational 1 –40 71 40 2 3 85 °C
TCCase temperature 40 95 40 2 3 105
TSStorage temperature Non operational 55 100 55 105
1See Thermal Considerations
2Start-up at –55 °C, except -RG models (synchronous rectifier)
3–25 °C for all -RG models (synchronous rectifier)
Immunity to Environmental Conditions
Table 12: Mechanical and climatic stress
Test Method Standard Test Conditions Status
Cab Damp heat IEC/EN 60068-2-78 Temperature: 40 ±2 C Converter
steady state MIL-STD-810D sect. 507.2 Relative humidity: 93 +2/-3 % not
Duration: 56 days operating
Ea 1Shock IEC/EN 60068-2-27 Acceleration amplitude: 50 gn = 490 m/s2Converter
(half-sinusoidal) MIL-STD-810D sect. 516.3 Bump duration: 11 ms operating
Number of bumps: 18 (3 each direction)
Eb Bump IEC/EN 60068-2-29 Acceleration amplitude: 25 gn = 245 m/s2Converter
(half-sinusoidal) MIL-STD-810D sect. 516.3 Bump duration: 1 ms operating
Number of bumps: 6000 (1000 each direction)
Fc Vibration IEC/EN 60068-2-6 Acceleration amplitude: 0.35 mm (10 to 60 Hz) Converter
(sinusoidal) 5 gn = 49 m/s2 (60 to 2000 Hz) operating
Frequency (1 Oct/min): 10 to 2000 Hz
Test duration: 7.5 h (2.5 h each axis)
Fda Random vibration IEC/EN 60068-2-35 Acceleration spectral density: 0.05 gn2/Hz Converter
wide band Frequency band: 20 to 500 Hz operating
reproducibility Acceleration magnitude: 4.9 gn rms
high Test duration: 3 h (1 h each axis)
Kb Salt mist, cyclic IEC/EN 60068-2-52 Concentration: 5% (30 °C) Converter
(sodium chloride Duration: 2 h per cycle not
NaCl solution) Storage: 40 °C, 93% rel. humidity operating
Storage duration: 22 h per cycle
Number of cycles: 3
1 Covers also EN 50155 /61373 category 1, class B, body mount (= chassis of a coach)
Reliability
Table 13: MTBF
Model Standard Ground Benign Ground Fixed Ground Mobile Unit
TC = 40 °C TC = 40 °C TC = 70 °C TC = 50 °C
20IMX15-12-12-8 MIL-HDBK-217F 697 000 366 000 229 000 312 000 h
20IMX15-15-15-8 Belcore 2 345 000 1 172 000 632 000 317 000
48IMS15-05-05-9 MIL-HDBK-217F 535 000 283 000 179 000 245 000
110IMY15-05-8R MIL-HDBK-217F 485 000 255 000 167 000 223 000
Belcore 1 547 000 774 000 394 000 206 000
®
BCD20008-G Rev AC, 26-Nov-2012 Page 17 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Mechanical Data
Dimensions in mm (inches)
Fig. 20
Case IMX15, IMS15, IMY15
Material: Fortron 1140L6
Weight: <35 g
Fig. 21
Open frame (option Z)
European
Projection
50.9 (2")
40.8 (1.6")
10.5 ±0.3 (0.41") 45.72 (1.8")
S09011c
1
4
47 (1.85")
36.83 (1.45")
Fixing hole for
M2 or KA 22
self-tapping screws
5.08 (0.2")
Measuring point of case temperature T
C
2
3
bottom view
3 x 5.08 (0.2")
2.54 (0.1")
5 (0.19")
12
11
17
12
13
15
0.8 (0.03")
for holes with
1.4 mm
12
48.3 (1.9")
8.9 ±0.3 (0.35") 45.72 (1.8")
S90011c
1
4
11
17
38.8 (1.52")
3 x 5.08 (0.2")
6 x 5.08 (0.2")
2
3
12
13
15
bottom view
2.54 (0.1")
5 (0.19")
0.8 (0.03")
for holes with
1.4 mm
®
BCD20008-G Rev AC, 26-Nov-2012 Page 18 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Safety and Installation Instructions
Pin allocation
CSA 60950-1 2nd Edition. 110IMY models are fitted with a CE
mark.
The converters have been evaluated for:
Building in
Supplementary insulation input to output, based on their
maximum input voltage (IMX15, IMS15)
Reinforced insulation input to output, based on their
maximum input voltage (IMY15 models)
Pollution degree 2 environment (not option Z)
Connecting the input to a secondary circuit subject to a
maximum transient rating of 1500 V (IMX15, IMS15)
Connecting the input to a secondary circuit subject to a
maximum transient rating of 2500 V (IMY15)
The converters are subject to manufacturing surveillance in
accordance with the above mentioned UL standards and with
ISO9001:2000.
Railway Applications
To comply with railway standards, all components are coated
with a protective lacquer (except option Z).
Protection Degree and Cleaning Liquids
The protection degree of the converters is IP 40, except open-
frame models (option Z).
In order to avoid possible damage, any penetration of
cleaning fluids should be prevented, since the power
supplies are not hermetical sealed.
However, open-frame models (option Z) leave the factory
unlacquered; they may be lacquered by the customer, for
instance together with the mother board. Cleaning agents are
not permitted – except washing at room temperature with
isopropyl alcohol. If necessary, the mother board must be
cleaned, before fitting the open-frame converter.
Note: Cleaning liquids may damage the adhesive joints of the
ferrite cores.
Isolation
The electric strength test is performed in the factory as routine
test in accordance with EN 50116 and IEC/EN 60950, and
should not be repeated in the field. Power-One will not honor
any warranty claims resulting from electric strength field tests.
Fig. 22
Footprint
1000
5
1
2
3
4
11
12
13
15
17
Bottom view
Installation Instructions
Installation must strictly follow the national safety regulations
in compliance with the enclosure, mounting, creepage,
clearance, casualty, markings and segregation requirements
of the end-use application.
Connection to the system shall be made via a printed circuit
board with hole diameters of 1.4 mm ±0.1 mm for the pins.
The converter must be connected to a secondary circuit.
Do not open the converter.
Ensure that a converter failure (e.g., by an internal short-
circuit) does not result in a hazardous condition.
Input Fuse
To prevent excessive current flowing through the input supply
lines in case of a malfunction an external fuse should be
installed in a non-earthed input supply line; see table 4 .
Standards and Approvals
The converters are approved according to IEC 60950-1 and UL/
Table 15: Pin allocation
Pin Standard and Option Z
single double -0503-
1 Vi+ Vi+ Vi+
2 Vi– Vi– Vi–
3 - Trim n.c.
4SD SD SD
5- - -
6- - -
11 - Vo1+ Vo2+
12 - Vo1– Go
13 Vo+ Vo2+ Vo1+
15 Vo Vo2– Go
17 R n.c. R
Table 16: Electric strength test voltages
Characteristic Input to output Output to Unit
IMS15 IMX15 IMY15 output
Factory test 1 s 1.2 1.513.0 0.1 kVAC
Equivalent DC voltage (1.7) (2.1) (4.2) 0.15 kVDC
Insulation resistance >100 >100 >100 - M
at 500 VDC
Partial discharge Consult Power-One - kV
extinction voltage
11.5 kVAC according to IEC 60950, sect. 6.2, Telecom equipment;
type test with 1.5 kVAC / 60 s (IEE 802.3). IMX15 units produced
before 2013 were tested only with 1.2 kVAC.
2The test voltage between outputs is not applied as routine test.
®
BCD20008-G Rev AC, 26-Nov-2012 Page 19 of 19 www.power-one.com
IMX15, IMS15, IMY15 Series Data Sheet
15 -Watt DC-DC Converters
Description of Options
Table 17: Survey of options
Option Function of option Characteristic
-9 Temperature range, NFND See table Temperatures specifications
R R-input and magnetic feedback; NFND as option Magnetic feedback for models without sychr. rectifier
i Inhibit
Z Open frame See Mechanical Data
Option -9 versus -8
IMX15 and IMY15 models with -9 (not for new designs) have a
limited temperature range. Standard models with suffix -8 are
rated up to TA = 85 °C; see table Temperature specifications.
Option R
Magnetic feedback from the output for closer regulation of the
output voltage Vo1 of double output units (standard for single
output units and -0503- models). It enables the adjustment of
the output voltages via the R-input (pin 17) on the secondary
side by an external resistor or an external voltage source. This
function is described in Auxiliary Functions.
Furthermore, the output 1 is accurately regulated like the
single output models. The Trim input (pin 3) is not connected.
Option i: Inhibit
Excludes the shut-down function.
The output(s) of the converter may be enabled or disabled by
means of a logic signal (TTL, CMOS, etc.) applied to the inhibit
pin. No output voltage overshoot will occur, when the converter
is turned on. If the inhibit function is not required, the inhibit pin
Fig. 23
If the inhibit function is not used, the inhibit pin should be
connected to Vi–.
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written
consent of the respective divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.
Vi+
Vi
i
06070
should be connected to Vi – to enable the output (active low
logic, fail safe).
Voltage on pin i:
Converter operating: –10 V to 0.8 V
Converter inhibited: 2.4 V to Vi max (<75 V) or
pin i left open-circuit:
Option G or -G
Products RoHS-compliant for all 6 substances. See sect.
RoHS-Compliant Models (page 3) for the correct denotation.