SPECIFICATION
200W Constant Power Mode DriverLED XLG-200 series
MODEL
RATED CURRENT
RATED POWER
FULL POWER CURRENT RANGE
OUTPUT
CURRENT ADJ RANGE.
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING HUMIDITY
STORAGE TEMP HUMIDITY.,
VIBRATION
MTBF
DIMENSION
OTHERS
OVER VOLTAGE
OVER TEMPERATURE
47 ~ 63Hz
2.2A / 115 1.1A / 230 0.9A / 277VAC VAC VAC
<0.75mA / 277VAC
Compliance to 55015, 61000-3-2 Class C ( ); 61000-3-3EN EN EN@ load 50%≧
Compliance to 61000-4-2,3,4,5,6,8,11, 61547,EN EN light industry level (surge immunity Line-Earth 6 , Line-Line 4 )(10K/6KV option)KV KV
20 ~ 95% non-condensingRH
-40 ~ +80 , 10 ~ 95% non-condensing
℃RH
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
749.06Khrs min. Telcordia -332(Bellcore) ; 200.67Khrs min. - -217F (25 )SR MIL HDBK ℃
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SHORT CIRCUIT
94% 93%
EMC IMMUNITY
EMC EMISSION
COLD START VAC65A(t =550 s measured at 50% I ) at 230 ;
width peakμPer 410NEMA
TOTAL HARMONIC DISTORTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4.2 I/P- :2.1 O/P- :1.5KVAC FG KVAC FG KVAC
I/P-O/P, I/P- , O/P- :100M Ohms / 500 / 25 / 70%FG FG VDC RH
℃
CONSTANT CURRENT REGION
Note.2
PACKING 0.85Kg;16pcs/14.2Kg/0.72CUFT
NOTE
MAX NO PSU. . of s on 16A
CIRCUIT BREAKER 3 unit(circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC
Hiccup mode or Constant current limiting,recovers automatically after fault condition is removed
(Please refer to " " ang “ "section)STATIC CHARACTERISTIC DRIVING METHODS OF LED MODULE
100 ~ 305 142 ~ 431VAC VDC VDC
OPEN CIRCUIT VOLTAGE (max.)
301 ~ 360V 61 ~ 78V
Shut down output voltage, re-power on to recovery
TEMP. COEFFICIENT ±℃ ℃0.03%/ (0 ~ 60 )
WORKING TEMP. Tcase=-40 ~ +90 (Please refer to " vs " section)℃OUTPUT LOAD TEMPERATURE
MAX CASE TEMP.. Tcase=+90℃
0.97 / 115 , 0.95 / 230 full loadPF VAC PF VAC≧≧≧, 0.92 / 277 atPF VAC
(Please refer to " " )Power Factor Characteristic section
THD VAC VAC VAC< 10% (@ load 50% at 115 /230 ,@load 75% at 277 )≧≧
Please refer to “ ( )” sectionTOTAL HARMONIC DISTORTION THD
CURRENT RIPPLE 3.0%(@ Load 50≥%rated voltage)
CURRENT TOLERANCE ±5%
SET UP TIME Note.4 500ms/230 , 1200ms/115VAC VAC
STANDBY
POWER CONSUMPTION
UL8750 ENEC EN61347-1, EN61347-2-13 independent, EN62384(type”HL”), CSA C22.2 No. 250.13-12; ;
GB19510.1 GB19510.14,; EAC TP TC 004;IP67 approved
199 63**35.5mm (L*W*H)
350~1050mA
700mA
200W
700~1050mA
142 ~285V
300V
XLG-200-L-
200W
3500mA
27 ~ 56V
60V
1750~5550mA
3500~5550mA
XLG-200-H-
Shut down output voltage, recovers automatically after fault condition is removed
Standby power consumption <0.5W for AB-Type(Dimming OFF)
INPUT OVER VOLTAGE
Note.5
320 ~ 390 (Shut down output voltage when the input voltage exceeds protection voltage)VAC
can survive input voltage stress of 440Vac for 48 hours
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. Please refer to "DRIVING METHODS OF LED MODULE".
3. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTIC sections for details
4. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
5.Only for XLG-200 I series
6. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
7. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70 or less.
℃
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
9.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED can only be used behind a switch without permanently connectedto
driver
the mains.
11.Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
12.For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
File Name:XLG-200-SPEC 2019-02-18
Adjustable for A/AB-Type only (via the built-in potentiometer)