MACP-010562 Temperature Compensated Directional RMS Power Detector 6 - 18 GHz Features Integrated Directional Coupler Low Insertion Loss: 0.3 dB @ 12 GHz Min. detectable power: -17 dBm @ 12 GHz Dynamic range: 45 dB @ 12 GHz Built-In Temperature Compensation Lead-Free 1.5 x 1.2 mm 6-Lead TDFN Pkg Halogen-Free "Green" Mold Compound RoHS* Compliant and 260C Reflow Compatible Rev. V2 Functional Schematic Description The MACP-010562 belongs to a series of small, easy-to-use, broadband, directional detectors. With integrated low loss directional couplers and built-in temperature compensation circuits, these detectors provide an easy way to monitor the power of a signal travelling in a specific direction along a transmission line. Detectors are housed in a miniature, surface mount, lead less plastic package. They require a small amount of bias for proper performance. The total bias current is less than 0.5 mA. Pin Configuration 3 Typical applications include power monitoring and leveling in Point-to-Point radios, IMS, Radar, VSAT, EW, and Aerospace & Defense systems. The surface mount package is small yet can be handled and placed with standard pick and place assembly equipment. Detectors are fabricated on a well established GaAs process featuring full passivation for performance and reliability. Pin No. Pin Name Description 1 RFOUT RF Output 2 N/C No Connection 3 RFIN RF Input 4 V bias Bias Voltage 5 N/C No Connection 6 V detect Output Voltage 7 GND Ground 3. Pins 2 and 5 are not connected internally and should not be used for grounding. Package has exposed bottom metal paddle (Pin 7) which should be connected to the circuit ground. The parasitic inductance introduced by this connection should be as small as possible. Ordering Information 1,2 Part Number Package MACP-010562-TR1000 1000 piece reel MACP-010562-001SMB Sample Board 1. Reference Application Note M513 for reel size information. 2. All sample boards include 5 loose parts. * Restrictions on Hazardous Substances, European Union Directive 2002/95/EC. 1 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MACP-010562 Temperature Compensated Directional RMS Power Detector 6 - 18 GHz Rev. V2 Electrical Specifications: Freq. = 12 GHz, TA = 25C, VB = +3.2 V, Z0 = 50 (unless otherwise specified) Parameter Test Conditions Units Min. Typ. Max. Insertion Loss 6 GHz 12 GHz 18 GHz dB -- 0.15 0.3 0.55 -- Detect Voltage 10 dBm applied to Input 6 GHz 12 GHz 18 GHz mV -- Directivity Into 50 load 6 GHz 12 GHz 18 GHz dB -- Sensitivity Minimum recommended power level 6 GHz 12 GHz 18 GHz dBm -- Maximum Power Maximum recommended power level 6 - 18 GHz dBm -- 30 -- Input Return Loss 6 - 18 GHz dB -- 18 -- Output Return Loss 6 - 18 GHz dB -- 20 -- DC Offset Detect voltage with no RF input power mV 50 100 150 Bias Current V Bias = 3.2 V mA -- 0.3 0.35 Absolute Maximum Ratings 4,5 Parameter Absolute Maximum Input Power +40 dBm Operating Voltage 8V Operating Temperature -40C to +85C Storage Temperature -65C to +150C 4. Exceeding any one or combination of these limits may cause permanent damage to this device. 5. M/A-COM Technology Solutions does not recommend sustained operation near these survivability limits. 195 375 615 -- 17 19 12 -- -11 -17 -21 -- Handling Procedures Please observe the following precautions to avoid damage: Static Sensitivity Gallium Arsenide Integrated Circuits are sensitive to electrostatic discharge (ESD) and can be damaged by static electricity. Proper ESD control techniques should be used when handling these devices. 2 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MACP-010562 Temperature Compensated Directional RMS Power Detector 6 - 18 GHz Application Information Rev. V2 Recommended PCB Configuration The MACP-010562 is designed to deliver high performance and to be easy to use. No external components are needed. The RF connections required by the MACP-010562 are shown in a schematic below. Pin 3 should be connected to the RF line bringing the input signal. Pin 1 is the RF output. The third required connection is that to the RF ground. The exposed metal paddle on the back of the package must be connected to the RF ground of the board housing the detector. This can be accomplished by using conductive via holes. It is important to ensure that the parasitic inductance associated with the connection between the detector and the RF ground is as small as possible. The RF ground also provides the return path for the DC bias current. Evaluation Board DC Bias MA-COM Technology Solutions' will supply an evaluation board and loose samples upon qualified request. The kit consists of a PCB and SMA connectors. MA-COM Technology Solutions' suggests a Rogers 4350 dielectric of .008" (0.20 mm) with 1/2 ounce copper. Proper grounding is always important, we suggest 8 mil (0.20 mm) vias placed generously underneath the part. The MACP-010562 operates with a positive 3.2 V bias applied to Pin 4. The output voltage is available on Pin 6. 3 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MACP-010562 Temperature Compensated Directional RMS Power Detector 6 - 18 GHz Rev. V2 Typical Performance Curves: Insertion Loss Detect Voltage vs. Input Power @ 12 GHz 0.0 4 -0.2 3 -0.4 2 +25C -40C +85C -0.6 -0.8 0 5 6 GHz 12 GHz 18 GHz 1 10 15 20 0 -5 0 5 Frequency (GHz) 15 20 Output Return Loss Input Return Loss 0 0 +25C -40C +85C -10 -20 -30 -30 -40 -40 0 5 +25C -40C +85C -10 -20 -50 10 Input Power (dBm) 10 15 20 -50 0 5 Frequency (GHz) 10 15 20 Frequency (GHz) Temperature Compensation Accuracy Directivity 25 30 20 6 GHz 12 GHz 18 GHz 20 15 10 10 +25C -40C +85C 5 0 0 5 0 10 Frequency (GHz) 15 20 -10 -5 0 5 10 15 Input Power (dBm) 4 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support 20 MACP-010562 Temperature Compensated Directional RMS Power Detector 6 - 18 GHz Rev. V2 Lead-Free 1.5 x 1.2 mm 6-Lead TDFN All dimensions are in inches/mm. Reference Application Note M538 for lead-free solder reflow recommendations. Meets JEDEC moisture sensitivity level 1 requirements. Plating is 100% matte tin over copper. 5 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support MACP-010562 Temperature Compensated Directional RMS Power Detector 6 - 18 GHz Rev. V2 M/A-COM Technology Solutions Inc. All rights reserved. Information in this document is provided in connection with M/A-COM Technology Solutions Inc ("MACOM") products. These materials are provided by MACOM as a service to its customers and may be used for informational purposes only. Except as provided in MACOM's Terms and Conditions of Sale for such products or in any separate agreement related to this document, MACOM assumes no liability whatsoever. MACOM assumes no responsibility for errors or omissions in these materials. MACOM may make changes to specifications and product descriptions at any time, without notice. MACOM makes no commitment to update the information and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to its specifications and product descriptions. No license, express or implied, by estoppels or otherwise, to any intellectual property rights is granted by this document. THESE MATERIALS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, RELATING TO SALE AND/OR USE OF MACOM PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, CONSEQUENTIAL OR INCIDENTAL DAMAGES, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. MACOM FURTHER DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. MACOM SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS, WHICH MAY RESULT FROM THE USE OF THESE MATERIALS. MACOM products are not intended for use in medical, lifesaving or life sustaining applications. MACOM customers using or selling MACOM products for use in such applications do so at their own risk and agree to fully indemnify MACOM for any damages resulting from such improper use or sale. 6 M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice. Visit www.macom.com for additional data sheets and product information. For further information and support please visit: https://www.macom.com/support