SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
5V
GS40A05
GS40A05-P1J GS40A07-P1J GS40A09-P1J GS40A12-P1J GS40A15-P1J GS40A18-P1J GS40A24-P1J GS40A48-P1J
7.5V
GS40A07
9V
GS40A09
12V
GS40A12
15V
GS40A15
18V
GS40A18
24V
GS40A24
48V
GS40A48
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5%
±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0% ±2.5% ±2.5%
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
80.5% 85.5%
7.88 ~ 10.13V
85%
9.45 ~ 12.15V
89%
12.6 ~ 16.2V
89.5%
15.75 ~ 20.25V
90%
18.9 ~ 24.3V
91%
25.2 ~ 32.4V
92%
50.4 ~ 64.8V
1A / 115VAC 0.5A / 230VAC
65A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
711K hrs min. MIL-HDBK-217F(25 )
-30 ~ +60 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
125*50*31.5mm (L*W*H)
0.28Kg; 40pcs/12.02Kg/1.05CUFT
CONNECTOR
PLUG
CABLE See page 2 ; Other type available by customer requested
See page 2 ; Other type available by customer requested
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
8. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
40WAC-DC Industrial Adaptor GS40 series
Features :
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
OVERLOAD
OVER VOLTAGE
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V
5A 5.34A 4.45A 3.34A 2.67A 2.22A 1.67A 0.84A
0 ~ 5A 0 ~ 5.34A 0 ~ 4.45A 0 ~ 2.67A 0 ~ 2.22A 0 ~ 1.67A
0 ~ 0.84A
25W 40W 40W 40W
0 ~ 3.34A
40W 40W 40W 40W
Protection type : Shut down o/p voltage, re-power on to recover
Universal AC input / Full range
No load power consumption<0.3W
Energy efficiency Level
Comply with EISA 2007, NRCan, AU/NZ MEPS and EU ErP
3 pole AC inlet IEC320-C14
Class power (with earth pin)I
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
LED indicator for power on
2 years warranty
1000ms, 30ms / 230VAC 1000ms, 30ms / 115VAC at full load
50ms / 230VAC 15ms / 115VAC at full load
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC IMMUNITY
EMC EMISSION
File Name:GS40-SPEC 2015-06-01
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, approvedPSE J60950-1(except for 48V)
(except for 48V)
Mechanical Specification
File Name:GS40-SPEC 2015-06-01
AMBIENT TEMPERATURE ( )
LOAD (%)
0-30 2010 30 40
20
40
80
60
100
6050 70
INPUT VOLTAGE (VAC) 60Hz
90 10095 120110 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
(HORIZONTAL)
Derating Curve Static Characteristics
POWER LED
-V not connected toAC FG
InsideOutside
Plug Assignment
Standard plug: P1J
P/N OUTPUT
P1J
CENTER +
GS40 series
40WAC-DC Industrial Adaptor
70 10mm±
11 0.5mm±
UL1185 16AWG 1000 50mm for 5 ~ 15V±
UL1185 18AWG 1800 50mm for 18 ~ 48V±
ID 2.1 x OD 5.5
C"+"
Case No. GS60A Unit:mm
125
31.5
50
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
GS40A18-P1J GS40A09-P1J GS40A07-P1J GS40A12-P1J GS40A15-P1J GS40A05-P1J GS40A24-P1J
GS40A48-P1J