www.RFM.com E-mail: info@rfm.com Page1of5
©2008 by RF Monolithics, Inc. DM1810-916MR-V - 4/17/08
DM1810-
916MR-V
Rating Value Units
All Input/Output Pins Except VIN -0.3 to +3.3 V
Non-Operating Ambient Temperature Range -40 to 85 oC
Absolute Maximum Ratings
Electrical Characteristics
Characteristic Sym Notes Minimum Typical Maximum Units
Operating Frequency fO916.30 916.70 MHz
Modulation Type OOK on BPSK Spreading Code
RF Encoded Data Transmission Rate 4.8 kb/s
Average Receive Input Current, No External Power Supply Load IR5.5 mA
Receiver Input Signal for 10-3 BER, 25 °C-100 dBm
Average Transmit Input Current, No External Power Supply Load ITA 15.75 mA
Peak Transmit Input Current, No External Power Supply Load ITP 32 mA
Peak Transmitter Output Power PO10 mW
Bind Input Logic High 2.4 V
Bind Input Logic Low 0.45 V
Average Sleep Input Current, No External Power Supply Load ISA 60 µA
Power Supply Input Voltage Range, -40 to +85 oC VIN 3.1 10 V
Power Supply Input Voltage Range, 0 to +85 oC VIN 2.6 10 V
Regulated Power Supply Output Voltage, VIN 3.1 to 10 V VOUT 3.0 Vdc
Regulated Power Supply Voltage Ripple 10 mVP-P
Relative Humidity Range, Non-Condensing RH 10 90 %
The DM1810-916MR-V is the 916.5 MHz router module in the DM1810 family of RF transceivers.
The DM1810 family is designed for adding wireless mesh connectivity to a wide range of monitor-
ing and control systems. This module is compatible with RFM miniMESHTM network protocol, which
provides “plug-and-play” multicast mesh network routing. Radio communications range in an “open
field” environment is typically 600 meters/hop. The DM1810-916MR-V combines RFM’s very low
current ASH radio technology with low power microcontroller technology to achieve long battery life.
The DM1810-916MR-V is certified for operation under FCC 15.247 and Canadian RSS 210 regula-
tions.
Network Router
Compatible with RFM miniMESHTM Network Protocol
3 V, Very Low Current Operation
Ready-to-Use OEM Module 916.50 MHz
Transceiver
Module
DEVELOPMENT KIT
(Info Click here)
www.RFM.com E-mail: info@rfm.com Page2of5
©2008 by RF Monolithics, Inc. DM1810-916MR-V - 4/17/08
Theory of Operation
The major components of the DM1810-916MR-V in-
clude an RFM TR8100 ASH transceiver and a Micro-
chip PIC16F689 microcontroller. The TR8100
operates on a frequency of 916.50 MHz, at a nominal
output power of 10 mW. The DM1810-916MR-V in-
cludes two LEDs that indicate the module’s operating
mode.
The DM1810-916MR-V firmware is based on RFM’s
miniMESH network protocol, which utilizes time-
synchronized redundant routing to provide robust,
deterministic packet delivery though a network with up
to 15 routers. Network configuration and maintenance
features are built into the miniMESH protocol, simplify-
ing commissioning and operating logistics. The firm-
ware also includes several sleep cycling methods for
extended battery life operation.
Please refer to the DM1810 User’s Guide and the
AN1810 series Application Notes for installation and
application programming information. See the RFM
web site at www.RFM.com.
DM1810-916MR-V FCC Certification
The DM1810-916MR-V hardware has been certified
for operation under FCC Part 15 Rules, Section
15.247. This certification applies when a DM1810-
916MR-V is equipped with one of the following anten-
nas:
helical antenna, part number 500-1195-204
helical antenna, part number 500-1311-000
The antenna(s) used for this transmitter must be in-
stalled to provide a separation distance of at least
20 cm from all persons and must not be co-located or
operating in conjunction with any other antenna or
transmitter.
FCC Notices and Labels
This device complies with Part 15 of the FCC rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
and (2) this device must accept any interference re-
ceived, including interference that may cause unde-
sired operation.
A clearly visible label is required on the outside of the
user’s (OEM) enclosure stating that this product con-
tains a DM1810-916MR-V transceiver assembly, FCC
ID: HSW-DM1810A. WARNING: This device oper-
ates under Part 15 of the FCC rules. Any modification
to this device, not expressly authorized by RFM, may
void the user’s authority to operate this device.
TXM O D
RX DATA
CNTRL1
CNTRL0
PIC
16F689
µP
D M 1810-916M R -V B lock D iagram
LED 1
LED 2
TR 8100
ASH
Transceiver
GND
BIND
GND
VOUT
VIN
3 V
Reg
GND
GND
J1-1
J1-2
J1-3
J1-4
J1-5
J1-6
J1-7
J1-8
J1-9
J1-10
J3-2
J3-1
J3-3
RSSI
J4-1
J4-2
D1
D2
Figure 1
Canadian Department of Communications Industry
Notice - IC: 4492A-DM1810A
This apparatus complies with Health Canada’s Safety
Code6/ICRSS210. To prevent radio interference to
the licensed service, this device is intended to be
operated indoors and away from windows to provide
maximum shielding. Equipment (or its transmit an-
tenna) that is installed outdoors may be subject to
licensing.
ICES-003
This digital apparatus does not exceed the Class B
limits for radio noise emissions from digital apparatus
as set out in the radio interference regulations of In-
dustry Canada.
Le present appareil numerique n’emet pas de bruits
radioelectriques depassant les limites applicables aux
appareils numeriques de Classe B prescrites dans le
reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
www.RFM.com E-mail: info@rfm.com Page3of5
©2008 by RF Monolithics, Inc. DM1810-916MR-V - 4/17/08
Pin Name Description
J1-1 GND This pad is a signal and power supply ground.
J1-2 VIN This is the power supply input pad. The allowed input voltage range is 2.6 to 10 V.
J1-3 VOUT
VOUT tracks 50 to 100 mV below VIN when VIN is in the range of 2.6 to 3.1 V. When VIN is in the range of 3.1
to 10 V, VOUT is regulated at 3.0 Vdc. Up to 10 mA can be supplied from this pad for powering external circuits
such as thermistor-resistor networks. External circuitry must not impress more than 10 mVp-p ripple on the regu-
lated output voltage.
J1-4 BIND
This pad is connected to a logic input on the microcontroller, and is configured with a weak pull-up. When this
pin is momentarily grounded to J1-1 or J1-10, the module is placed into the bind mode, allowing this module to
be associated with other modules to form a network.
J1-5 - This pad is unused in router operation. Leave this pad electrically unconnected.
J1-6 - This pad is unused in router operation. Leave this pad electrically unconnected.
J1-7 - This pad is unused in router operation. Leave this pad electrically unconnected.
J1-8 - This pad is unused in router operation. Leave this pad electrically unconnected.
J1-9 - This pad is unused in router operation. Leave this pad electrically unconnected.
J1-10 GND This pad is a signal and power supply ground.
J3-1 GND This pad is a ground for the antenna port.
J3-2 ANT This pad is the antenna port.
J3-3 GND This pad is a ground for the antenna port.
J4-1 D1 This pad is the LED 1 signal.
J4-2 D2 This pad is the LED 2 signal.
DM1810-916MR-V I/O Pad Descriptions
CAUTION: Electrostatic Sensitive Device. Observe precautions when handling.
www.RFM.com E-mail: info@rfm.com Page4of5
©2008 by RF Monolithics, Inc. DM1810-916MR-V - 4/17/08
D M 1810-916M R -V I/O P ad Labels
GND
BIND
VOUT
VIN
GND
GND
RFIO
GND
D1
D2
Figure 2
1.485
DM 1810-916M R-V SM T M ounting Pattern
1.000
.1 3 0 .0 9 0.0 9 0
.2 0 0 .2 0 0
.070 TY P
D im ensions in inches. PC B plus com ponent height is .170 m ax
.100 TY P
.1 2 0 .1 8 0
.1 0 0
.1 2 0
.0 9 5
P la c e .1 0 0 u n p la te d
antenna clearance hole
under antenna pad (do
not solder antenna pad)
Figure 3
www.RFM.com E-mail: info@rfm.com Page5of5
©2008 by RF Monolithics, Inc. DM1810-916MR-V - 4/17/08
1.25 1.71
1.0
D M 1810
D M 1810-916M R -V A ntenna D etail
Edge of host PCB
0.25 inches clearance required
around antenna and beyond
antenna tip; do not place
antenna on host P C B
D im ensions in inches.
Figure 4
Note: Specifications subject to change without notice.