Typical Applications Features
Base Stations AT-Cut Crystal
Test Equipment Dual-inline oszillator
Synthesizers Hermetically Sealed Package
Surface Mount Option
Frequency range 1 MHz – 8 MHz
Standard frequencies
Frequency stabilities
Parameter Code II Frequency stability Operating temp range
vs. operating temperature range 34 ± 15 ppm -40 ... +90°C
32 ± 10 ppm -30 ... +80°C
10 ± 50 ppm
12 ± 20 ppm -20 ... +70°C
14 ± 10 ppm
16 ± 7.5 ppm
18 ± 5 ppm
Parameter Code I Frequency stability Condition
Initial tolerance 01 ± 100 ppm @ 25C
02 ± 50 ppm
03 ± 20 ppm
05 ± 10 ppm
07 ± 5 ppm
RF output
Parameter Value Condition
Signal HCMOS
Load 15pF ± 10%
Rise and Fall time < 5ns @ 15pF & 10 to 90%
Duty cycle 40/60 % @Vs/2
Supply voltage
Parameter Value Condition
Supply voltage (VS)5.0 V ± 5 %
Current consumption < 20 mA
Additional parameters
Parameter Value Condition
Phase Noise < - 80 dBc/Hz 10 Hz Note 1
< - 110 dBc/Hz 100 Hz
< - 135 dBc/Hz 1kHz
< -145 dBc/Hz 10 kHz
< - 150 dBc/Hz 100 kHz
Weight < 6 g
Operable temperature range -40 ... +90°C
Storage temperature range -55 ... +125°C
Processing & Packing handling&processing note
TQDILC
PXO
Corning Frequency Control • Worldwide Data Book 2001 v1.0.2000-10-31
Corning Frequency Control Inc. • 100 Watts Street • Mt. Holly Springs, PA 17065 • Tel 1-717-486-3411 • Fax 1-717-486-5920 • www.corningfrequency.com
Tele Quarz GmbH & Co. KG • Landstrasse • D-74924 Neckarbischofsheim, Germany • Tel +49-7268-801-0 • Fax +49-07268-801-281 • www.telequarz.de
2 / 2
Additional Parameters
Parameter Option I Condition
Screening SScreening MIL STD 883 C method 5008.2 class B
BScreening MIL-O-55310, Class B
CScreening MIL-O-55310, Class C
Enclosure Option II Case Condition
Type Blank G125
AG175
Drawing
0,8max.
±0,5
±0,5
12,2
4,58
±0,3
±0,3
15,24
20,7max.
ø0,45
5,85min. H7,62
13,1max.
14 8
7
1
H = 7,5max.; G125 Standard
G 125
Pin Connections
Pin
Pin
Pin
Pin
1
7
8
14
N.C.
GND, Case
RF-Output
Supply voltage (VS)
±0,1
15,24
22,7max.
15,1max.
1,8
13,2
H
±0,1
±0,1
18,5max.
±0,2
10,9max.
S
0,1 S
Auflage
14 8
7
1
G 175
H = 9,4; G175 Standard
fläche
Pin 1 corner
all units in mm
Ordering Code Code I Code II Option I Option II
Model Adjustment
tolerance Frequency
Stability Screening Case Frequency
Example: TQDILC 05. 14. A4M0000
Order: TQDILC
Note
1Typical values @ 4 MHz
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage,
frequency control voltage, load, temperature (25°C)