AT25DL161 16-Mbit, 1.65V Minimum SPI Serial Flash Memory with Dual-I/O Support DATASHEET Features Single 1.65V - 1.95V supply Serial Peripheral Interface (SPI) compatible Supports SPI Modes 0 and 3 Supports RapidSTM operation Supports Dual-Input Program and Dual-Output Read Very high operating frequencies 100MHz for RapidS 85MHz for SPI Clock-to-output time (tV) of 5ns maximum Flexible, optimized erase architecture for code + data storage applications Uniform 4KB, 32KB, and 64KB Block Erase Full Chip Erase Individual sector protection with Global Protect/Unprotect feature 32 sectors of 64KB each Hardware controlled locking of protected sectors via WP pin Sector Lockdown with permanent freeze option Make any combination of 64KB sectors permanently read-only 128-byte, One-Time Programmable (OTP) Security Register 64 bytes factory preprogrammed, 64 bytes user programmable Flexible programming Byte/Page Program (1 to 256 bytes) Fast program and erase times 1.0ms typical Page Program (256 bytes) time 50ms typical 4KB Block Erase time 250ms typical 32KB Block Erase time 550ms typical 64KB Block Erase time Program and Erase Suspend/Resume Automatic checking and reporting of erase/program failures Software controlled reset JEDEC Standard Manufacturer and Device ID Read Methodology Low power dissipation 10mA Active Read current (typical at 20MHz) 8A Deep Power-Down current (typical) Endurance: 100,000 program/erase cycles Data retention: 20 years Complies with full industrial temperature range Industry standard green (Pb/halide-free/RoHS-compliant) package options 8-lead SOIC (0.150" wide) 8-pad Ultra-thin DFN (5 x 6 x 0.6mm) 8795H-DFLASH-11/2017 1. Description The AT25DL161 is a serial interface Flash memory device designed for use in a wide variety of high-volume, consumerbased applications in which program code is shadowed from Flash memory into embedded or external RAM for execution. The flexible erase architecture of the AT25DL161, with its erase granularity as small as 4KB, makes it ideal for data storage as well, eliminating the need for additional data storage EEPROM devices. The physical sectoring and the erase block sizes of the AT25DL161 have been optimized to meet the needs of today's code and data storage applications. By optimizing the size of the physical sectors and erase blocks, the memory space can be used much more efficiently. Because certain code modules and data storage segments must reside by themselves in their own protected sectors, the wasted and unused memory space that occurs with large sectored and large Block Erase Flash memory devices can be greatly reduced. This increased memory space efficiency allows additional code routines and data storage segments to be added, while still maintaining the same overall device density. The AT25DL161 also offers a sophisticated method for protecting individual sectors against erroneous or malicious program and erase operations. By providing the ability to individually protect and unprotect sectors, a system can unprotect a specific sector to modify its contents while keeping the remaining sectors of the memory array securely protected. This is useful in applications where program code is patched, updated on a subroutine or module basis, or in applications where data storage segments need to be modified without running the risk of errant modifications to the program code segments. In addition to individual sector protection capabilities, the AT25DL161 incorporates Global Protect and Global Unprotect features that allow the entire memory array to be either protected or unprotected all at once. This reduces overhead during the manufacturing process because sectors do not have to be unprotected one by one prior to initial programming. To take code and data protection to the next level, the AT25DL161 incorporates a sector lockdown mechanism that allows any combination of individual 64KB sectors to be locked down and become permanently read-only. This addresses the need of certain secure applications that require portions of the Flash memory array to be permanently protected against malicious attempts at altering program code, data modules, security information or encryption/decryption algorithms, keys, and routines. The device also contains a specialized, OTP (One-Time Programmable) security register, which can be used for unique device serialization, system-level Electronic Serial Number (ESN) storage, locked key storage, or other purposes. Specifically designed for use in 1.8V systems, the AT25DL161 supports read, program, and erase operations with a supply voltage range of 1.65V to 1.95V. No separate voltage is required for programming and erasing. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 2 2. Pin Descriptions and Pinouts Table 2-1. Symbol CS SCK Pin Descriptions Name and Function Chip Select: Asserting the CS pin selects the device. When the CS pin is deasserted, the device will be deselected and normally be placed in standby mode (not deep Power-Down mode) and the SO pin will be in a high-impedance state. When the device is deselected, data will not be accepted on the SI pin. A high-to-low transition on the CS pin is required to start an operation and a low-to-high transition is required to end an operation. When ending an internally self-timed operation, such as a program or erase cycle, the device will not enter the standby mode until the completion of the operation. Serial Clock: This pin is used to provide a clock to the device and is used to control the flow of data to and from the device. Command, address, and input data present on the SI pin is always latched in on the rising edge of SCK, while output data on the SO pin is always clocked out on the falling edge of SCK. Asserted State Type Low Input -- Input -- Input/Output -- Input/Output Low Input Serial Input (Serial Input/Output): The SI pin is used to shift data into the device. The SI pin is used for all data input including command and address sequences. Data on the SI pin is always latched in on the rising edge of SCK. SI (SIO) With the Dual-Output Read Array command, the SI pin becomes an output pin (SIO) to allow two bits (on the SO and SIO pins) of data to be clocked out on every falling edge of SCK. To maintain consistency with SPI nomenclature, the SIO pin will be referenced as SI throughout this document except for those sections dealing with the Dual-Output Read Array command, in which it will be referenced as SIO. Data present on the SI pin will be ignored whenever the device is deselected (CS is deasserted). Serial Output (Serial Output/Input): The SO pin is used to shift data out from the device. Data on the SO pin is always clocked out on the falling edge of SCK. SO (SOI) With the Dual-Input Byte/Page Program command, the SO pin becomes an input pin (SOI) to allow two bits (on the SOI and SI pins) of data to be clocked in on every rising edge of SCK. To maintain consistency with nomenclature, the SOI pin will be referenced as SO throughout this document except for those sections dealing with the Dual-Input Byte/Page Program command in which it will be referenced as SOI. The SO pin will be in a high-impedance state whenever the device is deselected (CS is deasserted). WP Write Protect: The WP pin controls the hardware locking feature of the device. See "Protection Commands and Features" on page 21 for more details on protection features and the WP pin. The WP pin is internally pulled-high and may be left floating if hardware controlled protection will not be used. However, it is recommended that the WP pin also be externally connected to VCC whenever possible. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 3 Table 2-1. Symbol Pin Descriptions (Continued) Name and Function Asserted State Type Low Input -- Power -- Power Hold: The HOLD pin is used to temporarily pause serial communication without deselecting or resetting the device. While the HOLD pin is asserted, transitions on the SCK pin and data on the SI pin will be ignored and the SO pin will be in a high-impedance state. HOLD The CS pin must be asserted and the SCK pin must be in the low state in order for a Hold condition to start. A Hold condition pauses serial communication only and does not have an affect on internally self-timed operations, such as a program or erase cycle. See "Hold" on page 46 for additional details on the Hold operation. The HOLD pin is internally pulled-high and may be left floating if the Hold function will not be used. However, it is recommended that the HOLD pin also be externally connected to the VCC whenever possible. VCC GND Device Power Supply: The VCC pin is used to supply the source voltage to the device. Operations at invalid VCC voltages may produce spurious results and should not be attempted. Ground: The ground reference for the power supply. GND should be connected to the system ground. Figure 2-1. 8-lead SOIC CS SO (SOI) WP GND 1 2 3 4 Top View Figure 2-2. 8-pad UDFN 8 7 6 5 VCC HOLD SCK SI (SIO) CS 1 8 VCC SO (SOI) 2 7 HOLD 3 6 SCK GND 4 5 SI (SIO) WP Top View AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 4 Block Diagram Figure 3-1. Block Diagram Control and Protection Logic CS SCK SI (SIO) SO (SOI) WP HOLD Note: I/O Buffers and Latches SRAM Data Buffer Interface Control and Logic Y-Decoder Address Latch 3. X-Decoder Y-Gating Flash Memory Array SIO and SOI pin naming convention is used for Dual-I/O commands. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 5 4. Memory Array To provide the greatest flexibility, the AT25DL161 memory array can be erased in four levels of granularity, including a full Chip Erase. In addition, the array has been divided into physical sectors of uniform size, which can be individually protected from program and erase operations. The size of the physical sectors is optimized for both code and data storage applications, allowing both code and data segments to reside in their own isolated regions. The memory architecture diagram illustrates the breakdown of each erase level, as well as the breakdown of each physical sector. Figure 4-1. Memory Architecture Diagram 1-256 byte Page Program (02h Command) 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes 256 bytes AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 6 5. Device Operation The AT25DL161 is controlled by a set of instructions that are sent from a host controller, commonly referred to as the SPI master. The SPI master communicates with the AT25DL161 via the SPI bus, which is comprised of four signal lines: Chip Select (CS), Serial Clock (SCK), Serial Input (SI), and Serial Output (SO). The SPI protocol defines a total of four modes of operation (Mode 0, 1, 2, or 3), with each mode differing in respect to the SCK polarity and phase and how the polarity and phase control the flow of data on the SPI bus. The AT25DL161 supports the two most common modes, SPI Modes 0 and 3. The only difference between SPI Modes 0 and 3 is the polarity of the SCK signal when in the inactive state (when the SPI master is in standby mode and not transferring any data). With SPI Modes 0 and 3, data is always latched in on the rising edge of SCK and always output on the falling edge of SCK. Figure 5-1. SPI Mode 0 and 3 CS SCK SI MSB SO 5.1 LSB MSB LSB Dual-I/O Operation The AT25DL161 features a Dual-Input Program mode and a Dual-Output Read mode that allow two bits of data to be clocked into or out of the device every clock cycle to improve throughput. To accomplish this, both the SI and SO pins are utilized as inputs/outputs for the transfer of data bytes. With the Dual-Input Byte/page Program command, the SO pin becomes an input along with the SI pin. Alternatively, with the Dual-Output Read Array command, the SI pin becomes an output along with the SO pin. For both Dual-I/O commands, the SO pin will be referred to as the SOI (Serial Output/Input) pin and the SI pin will be referred to as the SIO (Serial Input/Output) pin. 6. Commands and Addressing A valid instruction or operation must always be started by first asserting the CS pin. After the CS pin has been asserted, the host controller must then clock out a valid 8-bit opcode on the SPI bus. Following the opcode, instruction-dependent information, such as address and data bytes, would then be clocked out by the host controller. All opcode, address, and data bytes are transferred with the Most-Significant Bit (MSB) first. An operation is ended by deasserting the CS pin. Opcodes not supported by the AT25DL161 will be ignored by the device and no operation will be started. The device will continue to ignore any data presented on the SI pin until the start of the next operation (CS pin being deasserted and then reasserted). In addition, if the CS pin is deasserted before complete opcode and address information is sent to the device, then no operation will be performed, and the device will simply return to the idle state and wait for the next operation. Addressing of the device requires a total of three bytes of information to be sent, representing address bits A23-A0. Since the upper address limit of the AT25DL161 memory array is 1FFFFFh, address bits A23-A21 are always ignored by the device. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 7 Table 6-1. Command Listing Command Clock Frequency Address Bytes Dummy Bytes Data Bytes Read Commands 1Bh 0001 1011 Up to 100MHz 3 2 1+ 0Bh 0000 1011 Up to 85MHz 3 1 1+ 03h 0000 0011 Up to 40MHz 3 0 1+ 3Bh 0011 1011 Up to 66MHz 3 1 1+ Block Erase (4KB) 20h 0010 0000 Up to 100MHz 3 0 0 Block Erase (32KB) 52h 0101 0010 Up to 100MHz 3 0 0 Block Erase (64KB) D8h 1101 1000 Up to 100MHz 3 0 0 60h 0110 0000 Up to 100MHz 0 0 0 C7h 1100 0111 Up to 100MHz 0 0 0 Byte/Page Program (1 to 256 bytes) 02h 0000 0010 Up to 100MHz 3 0 1+ Dual-Input Byte/Page Program (1 to 256 bytes) A2h 1010 0010 Up to 100MHz 3 0 1+ Program/Erase Suspend B0h 1011 0000 Up to 100MHz 0 0 0 Program/Erase Resume D0h 1101 0000 Up to 100MHz 0 0 0 Write Enable 06h 0000 0110 Up to 100MHz 0 0 0 Write Disable 04h 0000 0100 Up to 100MHz 0 0 0 Protect Sector 36h 0011 0110 Up to 100MHz 3 0 0 Unprotect Sector 39h 0011 1001 Up to 100MHz 3 0 0 Read Array Dual-Output Read Array Program and Erase Commands Chip Erase Protection Commands Global Protect/Unprotect Read Sector Protection Registers Use Write Status Register Byte 1 Command 3Ch 0011 1100 Up to 100MHz 3 0 1+ Sector Lockdown 33h 0011 0011 Up to 100MHz 3 0 1 Freeze Sector Lockdown State 34h 0011 0100 Up to 100MHz 3 0 1 Read Sector Lockdown Registers 35h 0011 0101 Up to 100MHz 3 0 1+ Program OTP Security Register 9Bh 1001 1011 Up to 100MHz 3 0 1+ Read OTP Security Register 77h 0111 0111 Up to 100MHz 3 2 1+ Read Status Register 05h 0000 0101 Up to 100MHz 0 0 1+ Write Status Register Byte 1 01h 0000 0001 Up to 100MHz 0 0 1 Write Status Register Byte 2 31h 0011 0001 Up to 100MHz 0 0 1 Reset F0h 1111 0000 Up to 100MHz 0 0 1 Read Manufacturer and Device ID 9Fh 1001 1111 Up to 85MHz 0 0 1 to 5 Deep Power-Down B9h 1011 1001 Up to 100MHz 0 0 0 Resume from Deep Power-Down ABh 1010 1011 Up to 100MHz 0 0 0 Security Commands Status Register Commands Miscellaneous Commands AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 8 7. Read Commands 7.1 Read Array The Read Array command can be used to sequentially read a continuous stream of data from the device by simply providing the clock signal once the initial starting address has been specified. The device incorporates an internal address counter that automatically increments on every clock cycle. Three opcodes (1Bh, 0Bh, and 03h) can be used for the Read Array command. The use of each opcode depends on the maximum clock frequency that will be used to read data from the device. The 0Bh opcode can be used at any clock frequency up to the maximum specified by fCLK, and the 03h opcode can be used for lower frequency read operations, up to the maximum specified by fRDLF. The 1Bh opcode allows the highest read performance possible and can be used at any clock frequency up to the maximum specified by fMAX; however, use of the 1Bh opcode at clock frequencies above fCLK should be reserved for systems employing the RapidS protocol. To perform the Read Array operation, the CS pin must first be asserted and then the appropriate opcode (1Bh, 0Bh, or 03h) must be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to specify the location of the first byte to read within the memory array. Following the three address bytes, additional dummy bytes may need to be clocked into the device, depending on which opcode is used for the Read Array operation. If the 1Bh opcode is used, then two dummy bytes must be clocked into the device after the three address bytes. If the 0Bh opcode is used, then a single dummy byte must be clocked in after the address bytes. After the three address bytes (and any dummy bytes) have been clocked in, additional clock cycles will result in data being output on the SO pin. The data is always output with the MSB of a byte first. When the last byte (1FFFFFh) of the memory array has been read, the device will continue reading from the beginning of the array (000000h). No delays will be incurred when wrapping around from the end of the array to the beginning of the array. Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 9 Figure 7-1. Read Array - 1Bh Opcode CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 SCK Opcode SI 0 0 0 1 1 Address Bits A23-A0 0 1 A 1 MSB A A A A A A MSB Don't Care A A X X X X X Don't Care X X X MSB X X X X X X X X MSB Data Byte 1 SO High-impedance D D D D D D D MSB D D D MSB Figure 7-2. Read Array - 0Bh Opcode CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SCK Opcode SI 0 0 0 0 1 Address Bits A23-A0 0 1 1 MSB A A A A A A A Don't Care A A MSB X X X X X X X X MSB Data Byte 1 SO High-impedance D D MSB D D D D D D D D MSB Figure 7-3. Read Array - 03h Opcode CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 SCK Opcode SI 0 0 0 0 0 MSB Address Bits A23-A0 0 1 1 A A A A A A A A A MSB Data Byte 1 SO High-impedance D MSB D D D D D D D D D MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 10 7.2 Dual-Output Read Array The Dual-Output Read Array command is similar to the standard Read Array command and can be used to sequentially read a continuous stream of data from the device by simply providing the clock signal once the initial starting address has been specified. Unlike the standard Read Array command, however, the Dual-Output Read Array command allows two bits of data to be clocked out of the device on every clock cycle, rather than just one. The Dual-Output Read Array command can be used at any clock frequency, up to the maximum specified by fRDDO. To perform the Dual-Output Read Array operation, the CS pin must first be asserted and then the opcode 3Bh must be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to specify the location of the first byte to read within the memory array. Following the three address bytes, a single dummy byte must also be clocked into the device. After the three address bytes and the dummy byte have been clocked in, additional clock cycles will result in data being output on both the SO and SIO pins. The data is always output with the MSB of a byte first and the MSB is always output on the SO pin. During the first clock cycle, bit 7 of the first data byte is output on the SO pin, while bit 6 of the same data byte is output on the SIO pin. During the next clock cycle, bits 5 and 4 of the first data byte are output on the SO and SIO pins, respectively. The sequence continues with each byte of data being output after every four clock cycles. When the last byte (1FFFFFh) of the memory array has been read, the device will continue reading from the beginning of the array (000000h). No delays will be incurred when wrapping around from the end of the array to the beginning of the array. Deasserting the CS pin will terminate the read operation and put the SO and SIO pins into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 7-4. Dual-Output Read Array CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SCK Opcode SI (SIO) 0 0 1 1 1 MSB SO (SOI) High-impedance Address Bits A23-A0 0 1 1 A MSB A A A A A A Output Data Byte 1 Don't Care A A X X X X X X X X Output Data Byte 2 D6 D4 D2 D0 D6 D4 D2 D0 D6 D4 MSB D7 D5 D3 D1 D7 D5 D3 D1 D7 D5 MSB MSB MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 11 8. Program and Erase Commands 8.1 Byte/Page Program The Byte/Page program command allows anywhere from a single byte of data to 256 bytes of data to be programmed into previously erased memory locations. An erased memory location is one that has all eight bits set to the Logical 1 state (a byte value of FFh). Before a byte/page program command can be started, the Write Enable command must have been previously issued to the device (see "Write Enable" on page 21) to set the Write Enable Latch (WEL) bit of the Status Register to a Logical 1 state. To perform a Byte/Page Program command, a 02h opcode must be clocked into the device followed by the three address bytes denoting the first location of the memory array to begin programming at. After the address bytes have been clocked in, data can then be clocked into the device and be stored in an internal buffer. If the starting memory address denoted by A23-A0 does not fall on an even 256-byte page boundary (A7-A0 are not all 0), then special circumstances regarding which memory locations are to be programmed will apply. In this situation, any data that are sent to the device that go beyond the end of the page will wrap around to the beginning of the same page. In addition, if more than 256 bytes of data are sent to the device, then only the last 256 bytes sent will be latched into the internal buffer. Example: If the starting address denoted by A23-A0 is 0000FEh and three bytes of data are sent to the device, then the first two bytes of data will be programmed at addresses 0000FEh and 0000FFh, while the last byte of data will be programmed at address 000000h. The remaining bytes in the page (addresses 000001h through 0000FDh) will not be programmed and will remain in the erased state (FFh). When the CS pin is deasserted, the device will program the data stored in the internal buffer into the appropriate memory array locations based on the starting address specified by A23-A0 and the number of data bytes sent to the device. If fewer than 256 bytes of data are sent to the device, then the remaining bytes within the page will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is internally self-timed and should take place in a time of tPP or tBP if only programming a single byte. The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation and no data will be programmed into the memory array. In addition, if the address specified by A23-A0 points to a memory location within a sector that is in the protected state (see "Protect Sector" on page 23) or locked down (see "Sector Lockdown" on page 29), then the Byte/Page Program command will not be executed and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the Logical 0 state if the program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or because the memory location to be programmed is protected or locked down. While the device is programming, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tBP or tPP time to determine if the data bytes have finished programming. At some point before the program cycle completes, the WEL bit in the Status Register will be reset back to the Logical 0 state. The device also incorporates an intelligent programming algorithm that can detect when a byte location fails to program properly. If a programming error arises, it will be indicated by the EPE bit in the Status Register. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 12 Figure 8-1. Byte Program CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 SCK Opcode SI 0 0 0 0 0 Address Bits A23-A0 0 1 0 MSB SO A A A A A A A Data In A A MSB D D D D D D D D MSB High-impedance Figure 8-2. Page Program CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK Opcode SI 0 0 0 0 0 MSB SO Address Bits A23-A0 0 1 0 A MSB A A A A Data In Byte 1 A D MSB D D D D D Data In Byte n D D D D D D D D D D MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 13 8.2 Dual-Input Byte/Page Program The Dual-Input Byte/Page Program command is similar to the standard Byte/Page Program command and can be used to program anywhere from a single byte of data up to 256 bytes of data into previously erased memory locations. Unlike the standard byte/page program command, however, the Dual-Input Byte/Page Program command allows two bits of data to be clocked into the device on every clock cycle rather than just one. Before the Dual-Input Byte/Page Program command can be started, the Write Enable command must have been previously issued to the device (see "Write Enable" on page 21) to set the Write Enable Latch (WEL) bit of the Status Register to a Logical 1 state. To perform a Dual-Input Byte/Page Program command, an A2h opcode must be clocked into the device followed by the three address bytes denoting the first location of the memory array to begin programming at. After the address bytes have been clocked in, data can then be clocked into the device two bits at a time on both the SOI and SI pins. The data is always input with the MSB of a byte first, and the MSB is always input on the SOI pin. During the first clock cycle, bit 7 of the first data byte is input on the SOI pin while bit 6 of the same data byte is input on the SI pin. During the next clock cycle, bits 5 and 4 of the first data byte are input on the SOI and SI pins, respectively. The sequence continues with each byte of data being input after every four clock cycles. Like the standard Byte/Page Program command, all data clocked into the device are stored in an internal buffer. If the starting memory address denoted by A23-A0 does not fall on an even 256-byte page boundary (A7-A0 are not all 0), then special circumstances regarding which memory locations are to be programmed will apply. In this situation, any data that are sent to the device that go beyond the end of the page will wrap around to the beginning of the same page. In addition, if more than 256 bytes of data are sent to the device, then only the last 256 bytes sent will be latched into the internal buffer. Example: If the starting address denoted by A23-A0 is 0000FEh and three bytes of data are sent to the device, then the first two bytes of data will be programmed at addresses 0000FEh and 0000FFh, while the last byte of data will be programmed at address 000000h. The remaining bytes in the page (addresses 000001h through 0000FDh) will not be programmed and will remain in the erased state (FFh). When the CS pin is deasserted, the device will program the data stored in the internal buffer into the appropriate memory array locations based on the starting address specified by A23-A0 and the number of data bytes sent to the device. If fewer than 256 bytes of data are sent to the device, then the remaining bytes within the page will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is internally self-timed and should take place in a time of tPP or tBP if only programming a single byte. The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation and no data will be programmed into the memory array. In addition, if the address specified by A23-A0 points to a memory location within a sector that is in the protected state (see "Protect Sector" on page 23) or locked down (see "Sector Lockdown" on page 29), then the Byte/Page Program command will not be executed, and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the Logical 0 state if the program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or because the memory location to be programmed is protected or locked down. While the device is programming, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tBP or tPP time to determine if the data bytes have finished programming. At some point before the program cycle completes, the WEL bit in the Status Register will be reset back to the Logical 0 state. The device also incorporates an intelligent programming algorithm that can detect when a byte location fails to program properly. If a programming error arises, it will be indicated by the EPE bit in the Status Register. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 14 Figure 8-3. Dual-Input Byte Program CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 SCK Opcode SI (SIO) 1 0 1 0 0 0 1 0 A MSB SO (SOI) Input Data Byte Address Bits A23-A0 A A A A A A A A D6 D4 D2 D0 MSB High-impedance D7 D5 D3 D1 MSB Figure 8-4. Dual-Input Page Program CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 SCK Opcode SI (SIO) 1 0 1 0 0 MSB SO (SOI) High-impedance Input Data Byte 1 Address Bits A23-A0 0 1 0 A A A A A A A A A Input Data Byte 2 D6 D4 D2 D0 D6 D4 D2 D0 Input Data Byte n D6 D4 D2 D0 MSB D7 D5 D3 D1 D7 D5 D3 D1 MSB MSB D7 D5 D3 D1 MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 15 8.3 Block Erase A block of 4, 32, or 64KB can be erased (all bits set to the Logical 1 state) in a single operation by using one of three different opcodes for the Block Erase command. An opcode of 20h is used for a 4KB erase, an opcode of 52h is used for a 32KB erase, and an opcode of D8h is used for a 64KB erase. Before a Block Erase command can be started, the Write Enable command must have been previously issued to the device to set the WEL bit of the Status Register to a Logical 1 state. To perform a Block Erase, the CS pin must first be asserted and then the appropriate opcode (20h, 52h, or D8h) must be clocked into the device. After the opcode has been clocked in, three address bytes specifying the address within the 4, 32, or 64KB block to be erased must be clocked in. Any additional data clocked into the device will be ignored. When the CS pin is deasserted, the device will erase the appropriate block. The erasing of the block is internally self-timed and should take place in a time of tBLKE. Since the Block Erase command erases a region of bytes, the lower order address bits do not need to be decoded by the device. Therefore, for a 4KB erase, address bits A11-A0 will be ignored by the device and their values can be either a Logical 1 or 0. For a 32KB erase, address bits A14-A0 will be ignored and for a 64KB erase, address bits A15-A0 will be ignored. Despite the lower order address bits not being decoded by the device, the three complete address bytes must still be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and no Erase operation will be performed. If the address specified by A23-A0 points to a memory location within a sector that is in the protected or locked down state, then the Block Erase command will not be executed and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the Logical 0 state if the erase cycle aborts due to an incomplete address being sent, the CS pin being deasserted on uneven byte boundaries, or because a memory location within the region to be erased is protected or locked down. While the device is executing a successful erase cycle, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tBLKE time to determine if the device has finished erasing. At some point before the erase cycle completes, the WEL bit in the Status Register will be reset back to the Logical 0 state. The device also incorporates an intelligent erase algorithm that can detect when a byte location fails to erase properly. If an erase error occurs, it will be indicated by the EPE bit in the Status Register. Figure 8-5. Block Erase CS 0 1 2 3 4 5 6 7 8 9 10 11 12 26 27 28 29 30 31 SCK Opcode SI C C C C C MSB SO Address Bits A23-A0 C C C A A A A A A A A A A A A MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 16 8.4 Chip Erase The entire memory array can be erased in a single operation by using the Chip Erase command. Before a Chip Erase command can be started, the Write Enable command must have been previously issued to the device to set the WEL bit of the Status Register to a Logical 1 state. Two opcodes, 60h and C7h, can be used for the Chip Erase command. There is no difference in device functionality when utilizing the two opcodes, so they can be used interchangeably. To perform a Chip Erase, one of the two opcodes (60h or C7h) must be clocked into the device. Since the entire memory array is to be erased, no address bytes need to be clocked into the device and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the device will erase the entire memory array. The erasing of the device is internally self-timed and should take place in a time of tCHPE. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no erase will be performed. In addition, if any sector of the memory array is in the protected or locked down state, then the Chip Erase command will not be executed and the device will return to the idle state once the CS pin has been deasserted. The WEL bit in the Status Register will be reset back to the Logical 0 state if the CS pin is deasserted on uneven byte boundaries or if a sector is in the protected or locked down state. While the device is executing a successful erase cycle, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tCHPE time to determine if the device has finished erasing. At some point before the erase cycle completes, the WEL bit in the Status Register will be reset back to the Logical 0 state. The device also incorporates an intelligent erase algorithm that can detect when a byte location fails to erase properly. If an erase error occurs, it will be indicated by the EPE bit in the Status Register. Figure 8-6. Chip Erase CS 0 1 2 3 4 5 6 7 SCK Opcode SI C C C C C C C C MSB SO High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 17 8.5 Program/Erase Suspend In some code-plus-data storage applications, it is often necessary to process certain high-level system interrupts that require relatively immediate reading of code or data from the Flash memory. In such an instance, it may not be possible for the system to wait the microseconds or milliseconds required for the Flash memory to complete a program or erase cycle. The Program/Erase Suspend command allows a program or erase operation in progress on a particular 64KB sector of the Flash memory array to be suspended so that other device operations can be performed. By suspending an erase operation on a particular sector, the system can perform a program or read operation within another 64KB sector of the device. Other device operations, such as a Read Status Register, can also be performed while a program or erase operation is suspended. Table 8-1 outlines the operations that are allowed and not allowed while a program or erase operation is suspended. Since the need to suspend a program or erase operation is immediate, the Write Enable command does not need to be issued prior to the Program/Erase Suspend command being issued. Therefore, the Program/Erase Suspend command operates independently of the state of the WEL bit in the Status Register. To perform a Program/Erase Suspend, the CS pin must first be asserted and then the opcode B0h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the program or erase operation currently in progress will be suspended within a time of tSUSP. The Program Suspend (PS) bit or the Erase Suspend (ES) bit in the Status Register will then be set to the Logical 1 state to indicate that the program or erase operation has been suspended. In addition, the RDY/BSY bit in the Status Register will indicate that the device is ready for another operation. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no suspend operation will be performed. Read operations are not allowed to a 64KB sector that has had its program or erase operation suspended. If a read is attempted to a suspended sector, then the device will output undefined data. Therefore, if performing a Read Array operation on an unsuspended sector, and if the device's internal address counter increments and crosses the sector boundary to a suspended sector, the device will then start outputting undefined data continuously until the address counter increments and crosses a sector boundary to an unsuspended sector. A program operation is not allowed on a sector that has been erase suspended. If a program operation is attempted on an erase suspended sector, then the program operation will abort and the WEL bit in the Status Register will be reset back to the Logical 0 state. Likewise, an erase operation is not allowed on a sector that has been program suspended. If attempted, the erase operation will abort and the WEL bit in the Status Register will be reset to a Logical 0 state. During an Erase Suspend, a program operation to a different 64KB sector can be started and subsequently suspended. This results in a simultaneous Erase Suspend/Program Suspend condition, which will be indicated by the ES and PS bits in the Status Register being set to the Logical 1 state. If a Reset operation (see "Reset" on page 41) is performed while a sector is erase suspended, the suspend operation will abort and the contents of the block in the suspended sector will be left in an undefined state. However, if a Reset is performed while a sector is program suspended, the suspend operation will abort, but only the contents of the page that was being programmed and subsequently suspended will be undefined. The remaining pages in the 64KB sector will retain their previous contents. If an attempt is made to perform an operation that is not allowed while a program or erase operation is suspended, such as a Protect Sector command, then the device will simply ignore the opcode and no operation will be performed. The state of the WEL bit in the Status Register, as well as the SPRL (Sector Protection Registers Locked) and SLE (Sector Lockdown Enabled) bits, will not be affected. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 18 . Table 8-1. Operations Allowed and Not Allowed During a Program/Erase Suspend Operation During Program Suspend Operation During Erase Suspend Allowed Allowed Block Erase Not Allowed Not Allowed Chip Erase Not Allowed Not Allowed Byte/Page Program (All Opcodes) Not Allowed Allowed Program/Erase Suspend Not Allowed Allowed Program/Erase Resume Allowed Allowed Write Enable Not Allowed Allowed Write Disable Not Allowed Allowed Protect Sector Not Allowed Not Allowed Unprotect Sector Not Allowed Not Allowed Global Protect/Unprotect Not Allowed Not Allowed Allowed Allowed Sector Lockdown Not Allowed Not Allowed Freeze Sector Lockdown State Not Allowed Not Allowed Allowed Allowed Not Allowed Not Allowed Allowed Allowed Allowed Allowed Not Allowed Not Allowed Reset Allowed Allowed Read Manufacturer and Device ID Allowed Allowed Deep Power-Down Not Allowed Not Allowed Resume from Deep Power-Down Not Allowed Not Allowed Command Read Commands Read Array (All Opcodes) Program and Erase Commands Protection Commands Read Sector Protection Registers Security Commands Read Sector Lockdown Registers Program OTP Security Register Read OTP Security Register Status Commands Read Status Register Write Status Register (All Opcodes) Miscellaneous Commands Figure 8-7. Program/Erase Suspend CS 0 1 2 3 4 5 6 7 SCK Opcode SI 1 0 1 1 0 0 0 0 MSB SO High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 19 8.6 Program/Erase Resume The Program/Erase Resume command allows a suspended program or erase operation to be resumed and continue programming a Flash page or erasing a Flash memory block from where it left off. As with the Program/Erase Suspend command, the Write Enable command does not need to be issued prior to the Program/Erase Resume command being issued. Therefore, the Program/Erase Resume command operates independently of the state of the WEL bit in the Status Register. To perform a Program/Erase Resume, the CS pin must first be asserted and then the opcode D0h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the program or erase operation currently suspended will be resumed within a time of tRES. The PS bit or the ES bit in the Status Register will then be reset back to the Logical 0 state to indicate that the program or erase operation is no longer suspended. In addition, the RDY/BSY bit in the Status Register will indicate that the device is busy performing a program or erase operation. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no resume operation will be performed. During a simultaneous Erase Suspend/Program Suspend condition, issuing the Program/Erase Resume command will result in the program operation resuming first. After the program operation has been completed, the Program/Erase Resume command must be issued again in order for the erase operation to be resumed. While the device is busy resuming a program or erase operation, any attempts at issuing the Program/Erase Suspend command will be ignored. Therefore, if a resumed program or erase operation needs to be subsequently suspended again, the system must either wait the entire tRES time before issuing the Program/Erase Suspend command, or it must check the status of the RDY/BSY bit or the appropriate PS or ES bit in the Status Register to determine if the previously suspended program or erase operation has resumed. Figure 8-8. Program/Erase Resume CS 0 1 2 3 4 5 6 7 SCK Opcode SI 1 1 0 1 0 0 0 0 MSB SO High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 20 9. Protection Commands and Features 9.1 Write Enable The Write Enable command is used to set the Write Enable Latch (WEL) bit in the Status Register to a Logical 1 state. The WEL bit must be set before a Byte/Page Program, Erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, Write Status Register, or Write Configuration Register command can be executed. This makes the issuance of these commands a two-step process, thereby reducing the chances of a command being accidentally or erroneously executed. If the WEL bit in the Status Register is not set prior to the issuance of one of these commands, then the command will not be executed. To issue the Write Enable command, the CS pin must first be asserted and then the opcode 06h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be set to a Logical 1. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the state of the WEL bit will not change. Figure 9-1. Write Enable CS 0 1 2 3 4 5 6 7 SCK Opcode SI 0 0 0 0 0 1 1 0 MSB SO High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 21 9.2 Write Disable The Write Disable command is used to reset the Write Enable Latch (WEL) bit in the Status Register to the Logical 0 state. With the WEL bit reset, all Byte/Page Program, Erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, Write Status Register, and Write Configuration Register commands will not be executed. Other conditions can also cause the WEL bit to be reset. For more details, refer to the WEL bit section of the Status Register description. To issue the Write Disable command, the CS pin must first be asserted and then the opcode 04h must be clocked into the device. No address bytes need to be clocked into the device, and any data clocked in after the opcode will be ignored. When the CS pin is deasserted, the WEL bit in the Status Register will be reset to a Logical 0. The complete opcode must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and the state of the WEL bit will not change. Figure 9-2. Write Disable CS 0 1 2 3 4 5 6 7 SCK Opcode SI 0 0 0 0 0 1 0 0 MSB SO High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 22 9.3 Protect Sector Every physical 64KB sector of the device has a corresponding single-bit Sector Protection Register that is used to control the software protection of a sector. Upon device power-up, each Sector Protection Register will default to the Logical 1 state indicating that all sectors are protected and cannot be programmed or erased. Issuing the Protect Sector command to a particular sector address will set the corresponding Sector Protection Register to the Logical 1 state. The following table outlines the two states of the Sector Protection Registers. Table 9-1. Value Sector Protection Register Values Sector Protection Status 0 Sector is unprotected and can be programmed and erased. 1 Sector is protected and cannot be programmed or erased (the default state). Before the Protect Sector command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. To issue the Protect Sector command, the CS pin must first be asserted, and then the opcode 36h must be clocked into the device followed by three address bytes designating any address within the sector to be protected. Any additional data clocked into the device will be ignored. When the CS pin is deasserted, the Sector Protection Register corresponding to the physical sector addressed by A23-A0 will be set to the Logical 1 state and the sector itself will then be protected from program and erase operations. In addition, the WEL bit in the Status Register will be reset back to the Logical 0 state. The three complete address bytes must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation. When the device aborts the Protect Sector operation, the state of the Sector Protection Register will be unchanged, and the WEL bit in the Status Register will be reset to a Logical 0. As a safeguard against accidental or erroneous protecting or unprotecting of sectors, the Sector Protection Registers can themselves be locked from updates by using the SPRL (Sector Protection Registers Locked) bit of the Status Register (please refer to the Status Register description for more details). If the Sector Protection Registers are locked, then any attempts to issue the Protect Sector command will be ignored, and the device will reset the WEL bit in the Status Register back to a Logical 0 and return to the idle state once the CS pin has been deasserted. Figure 9-3. Protect Sector CS 0 1 2 3 4 5 6 7 8 9 10 11 12 26 27 28 29 30 31 SCK Opcode SI (SIO) 0 0 1 1 0 MSB SO (SOI) Address Bits A23-A0 1 1 0 A A A A A A A A A A A A MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 23 9.4 Unprotect Sector Issuing the Unprotect Sector command to a particular sector address will reset the corresponding Sector Protection Register to the Logical 0 state (see Table 9-1 for Sector Protection Register values). Every physical sector of the device has a corresponding single-bit Sector Protection Register that is used to control the software protection of a sector. Before the Unprotect Sector command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. To issue the Unprotect Sector command, the CS pin must first be asserted and then the opcode 39h must be clocked into the device. After the opcode has been clocked in, the three address bytes designating any address within the sector to be unprotected must be clocked in. Any additional data clocked into the device after the address bytes will be ignored. When the CS pin is deasserted, the Sector Protection Register corresponding to the sector addressed by A23-A0 will be reset to the Logical 0 state and the sector itself will be unprotected. In addition, the WEL bit in the Status Register will be reset back to the Logical 0 state. The three complete address bytes must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation, the state of the Sector Protection Register will be unchanged, and the WEL bit in the Status Register will be reset to a Logical 0. As a safeguard against accidental or erroneous locking or unlocking of sectors, the Sector Protection Registers can themselves be locked from updates by using the SPRL (Sector Protection Registers Locked) bit of the Status Register (please refer to the Status Register description for more details). If the Sector Protection Registers are locked, then any attempts to issue the Unprotect Sector command will be ignored, and the device will reset the WEL bit in the Status Register back to a Logical 0 and return to the idle state once the CS pin has been deasserted. Figure 9-4. Unprotect Sector CS 0 1 2 3 4 5 6 7 8 9 10 11 12 26 27 28 29 30 31 SCK Opcode SI (SIO) 0 0 1 1 1 MSB SO (SOI) Address Bits A23-A0 0 0 1 A A A A A A A A A A A A MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 24 9.5 Global Protect/Unprotect The Global Protect and Global Unprotect features can work in conjunction with the Protect Sector and Unprotect Sector functions. Example: A system can globally protect the entire memory array and then use the Unprotect Sector command to individually unprotect certain sectors and individually reprotect them later by using the Protect Sector command. Likewise, a system can globally unprotect the entire memory array and then individually protect certain sectors as needed. Performing a Global Protect or Global Unprotect is accomplished by writing a certain combination of data to the Status Register using the Write Status Register Byte 1 command (see "Write Status Register Byte 1" on page 39 for command execution details). The Write Status Register command is also used to modify the SPRL (Sector Protection Registers Locked) bit to control hardware and software locking. To perform a Global Protect, the appropriate WP pin and SPRL conditions must be met, and the system must write a Logical 1 to bits 5, 4, 3, and 2 of the first byte of the Status Register. Conversely, to perform a Global Unprotect, the same WP and SPRL conditions must be met, but the system must write a Logical 0 to bits 5, 4, 3, and 2 of the first byte of the Status Register. Table 9-2 details the conditions necessary for a Global Protect or Global Unprotect to be performed. Sectors that have been erase or program suspended must remain in the unprotected state. If a Global Protect operation is attempted while a Sector is Erase or program suspended, the Protection operation will abort, the protection states of all sectors in the Flash memory array will not change, and the WEL bit in the Status Register will be reset back to a Logical 0. Essentially, if the SPRL bit of the Status Register is in the Logical 0 state (Sector Protection Registers are not locked), then writing a 00h to the first byte of the Status Register will perform a Global Unprotect without changing the state of the SPRL bit. Similarly, writing a 7Fh to the first byte of the Status Register will perform a Global Protect and keep the SPRL bit in the Logical 0 state. The SPRL bit can, of course, be changed to a Logical 1 by writing an FFh if software-locking or hardware-locking is desired along with the Global Protect. If the desire is to only change the SPRL bit without performing a Global Protect or Global Unprotect, then the system can simply write a 0Fh to the first byte of the Status Register to change the SPRL bit from a Logical 1 to a Logical 0, provided the WP pin is deasserted. Likewise, the system can write an F0h to change the SPRL bit from a Logical 0 to a Logical 1 without affecting the current sector protection status (no changes will be made to the Sector Protection Registers). When writing to the first byte of the Status Register, bits 5, 4, 3, and 2 will not actually be modified, but will be decoded by the device for the purposes of the Global Protect and Global Unprotect functions. Only bit 7, the SPRL bit, will actually be modified. Therefore, when reading the first byte of the Status Register, bits 5, 4, 3, and 2 will not reflect the values written to them, but will instead indicate the status of the WP pin and the sector protection status. Please refer to "Read Status Register" on page 35 and Table 11-1 on page 35 for details on the Status Register format and what values can be read for bits 5, 4, 3, and 2. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 25 Table 9-2. WP State 0 Valid SPRL and Global Protect/Unprotect Conditions Current SPRL Value New Write Status Register Byte 1 data New SPRL Value Bit 76543210 Protection Operation 0x0000xx 0x0001xx 0x1110xx 0x1111xx Global Unprotect - all Sector Protection Registers reset to 0 No change to current protection No change to current protection No change to current protection Global Protect - all Sector Protection Registers set to 1 0 0 0 0 0 1x0000xx 1x0001xx 1x1110xx 1x1111xx Global Unprotect - all Sector Protection Registers reset to 0 No change to current protection No change to current protection No change to current protection Global Protect - all Sector Protection Registers set to 1 1 1 1 1 1 0 No change to the current protection level. All sectors currently protected will remain protected and all sectors currently unprotected will remain unprotected. 0 1 1 xxxxxxxx The Sector Protection Registers are hard-locked and cannot be changed when the WP pin is low and the current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur. In addition, the SPRL bit cannot be changed (the WP pin must be high in order to change SPRL back to a 0). 0x0000xx 0x0001xx 0x1110xx 0x1111xx Global Unprotect - all Sector Protection Registers reset to 0 No change to current protection No change to current protection No change to current protection Global Protect - all Sector Protection Registers set to 1 0 0 0 0 0 1x0000xx 1x0001xx 1x1110xx 1x1111xx Global Unprotect - all Sector Protection Registers reset to 0 No change to current protection No change to current protection No change to current protection Global Protect - all Sector Protection Registers set to 1 1 1 1 1 1 0 0x0000xx 0x0001xx 0x1110xx 0x1111xx 1 1 1x0000xx 1x0001xx 1x1110xx 1x1111xx No change to the current protection level. All sectors currently protected will remain protected and all sectors currently unprotected will remain unprotected. The Sector Protection Registers are soft-locked and cannot be changed when the current state of SPRL is 1. Therefore, a Global Protect/Unprotect will not occur. However, the SPRL bit can be changed back to a 0 from a 1 since the WP pin is high. To perform a Global Protect/Unprotect, the Write Status Register command must be issued again after the SPRL bit has been changed from 1 to 0. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 0 0 0 0 0 1 1 1 1 1 26 9.6 Read Sector Protection Registers The Sector Protection Registers can be read to determine the current software protection status of each sector. Reading the Sector Protection Registers, however, will not determine the status of the WP pin. To read the Sector Protection Register for a particular sector, the CS pin must first be asserted and then the opcode 3Ch must be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the sector must be clocked in. After the last address byte has been clocked in, the device will begin outputting data on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of the appropriate Sector Protection Register. At clock frequencies above fCLK, the first byte of data output will not be valid. Therefore, if operating at clock frequencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the correct status of the appropriate Sector Protection Register. Table 9-3. Read Sector Protection Register - Output Data Output Data Sector Protection Register Value 00h Sector Protection Register value is 0 (sector is unprotected). FFh Sector Protection Register value is 1 (sector is protected). Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. In addition to reading the individual Sector Protection Registers, the Software Protection Status (SWP) bits in the Status Register can be read to determine if all, some, or none of the sectors are software protected (refer to "Read Status Register" on page 35 for more details). Figure 9-5. Read Sector Protection Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 SCK Opcode SI 0 0 1 1 1 MSB Address Bits A23-A0 1 0 0 A A A A A A A A A MSB Data Byte SO High-impedance D MSB D D D D D D D D D MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 27 9.7 Protected States and the Write Protect (WP) Pin The WP pin is not linked to the memory array itself and has no direct effect on the protection status or lockdown status of the memory array. Instead, the WP pin, in conjunction with the SPRL (Sector Protection Registers Locked) bit in the Status Register, is used to control the hardware locking mechanism of the device. For hardware locking to be active, two conditions must be met: the WP pin must be asserted and the SPRL bit must be in the Logical 1 state. When hardware locking is active, the Sector Protection Registers are locked and the SPRL bit itself is also locked. Therefore, sectors that are protected will be locked in the protected state and sectors that are unprotected will be locked in the unprotected state. These states cannot be changed as long as hardware locking is active, so the Protect Sector, Unprotect Sector, and Write Status Register commands will be ignored. In order to modify the protection status of a sector, the WP pin must first be deasserted, and the SPRL bit in the Status Register must be reset back to the Logical 0 state using the Write Status Register command. When resetting the SPRL bit back to a Logical 0, it is not possible to perform a Global Protect or Global Unprotect at the same time because the Sector Protection Registers remain soft-locked until after the Write Status Register command has been executed. If the WP pin is permanently connected to GND, then once the SPRL bit is set to a Logical 1, the only way to reset the bit back to the Logical 0 state is to power-cycle the device. This allows a system to power up with all sectors software protected but not hardware locked. Therefore, sectors can be unprotected and protected as needed and then hardware locked at a later time by simply setting the SPRL bit in the Status Register. When the WP pin is deasserted, or if the WP pin is permanently connected to VCC, the SPRL bit in the Status Register can still be set to a Logical 1 to lock the Sector Protection Registers. This provides a software locking ability to prevent erroneous Protect Sector or Unprotect Sector commands from being processed. When changing the SPRL bit to a Logical 1 from a Logical 0, it is also possible to perform a Global Protect or Global Unprotect at the same time by writing the appropriate values into bits 5, 4, 3, and 2 of the first byte of the Status Register. Tables 9-4 and 9-5 detail the various protection and locking states of the device . Table 9-4. Note: Sector Protection Register States WP Sector Protection Register n(1) Sector n(1) X 0 Unprotected (Don't Care) 1 Protected 1. Table 9-5. "n" represents a sector number. Hardware and Software Locking WP SPRL 0 0 0 1 1 0 1 1 Locking Hardware locked Software locked SPRL Change Allowed Sector Protection Registers Can be modified from 0 to 1 Unlocked and modifiable using the Protect and Unprotect Sector commands. Global Protect and Unprotect can also be performed. Locked Locked in current state. Protect and Unprotect Sector commands will be ignored. Global Protect and Unprotect cannot be performed. Can be modified from 0 to 1 Unlocked and modifiable using the Protect and Unprotect Sector commands. Global Protect and Unprotect can also be performed. Can be modified from 1 to 0 Locked in current state. Protect and Unprotect Sector commands will be ignored. Global Protect and Unprotect cannot be performed. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 28 10. Security Commands 10.1 Sector Lockdown Certain applications require that portions of the Flash memory array be permanently protected against malicious attempts at altering program code, data modules, security information or encryption/decryption algorithms, keys, and routines. To address these applications, the device incorporates a sector lockdown mechanism that allows any combination of individual 64KB sectors to be permanently locked so that they become read-only. Once a sector is locked down, it can never be erased or programmed again, and it can never be unlocked from the locked-down state. Each 64KB physical sector has a corresponding single-bit Sector Lockdown Register that is used to control the lockdown status of that sector. These registers are nonvolatile and will retain their state even after a device power cycle or Reset operation. The following table outlines the two states of the Sector Lockdown Registers. Table 10-1. Sector Lockdown Register Values Value Sector Lockdown Status 0 Sector is not locked down and can be programmed and erased (the default state). 1 Sector is permanently locked down and can never be programmed or erased again. Issuing the Sector Lockdown command to a particular sector address will set the corresponding Sector Lockdown Register to the Logical 1 state. Each Sector Lockdown Register can only be set once; therefore, once set to the Logical 1 state, a Sector Lockdown Register cannot be reset back to the Logical 0 state. Before the Sector Lockdown command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. In addition, the Sector Lockdown Enabled (SLE) bit in the Status Register must have also been previously set to the Logical 1 state by using the Write Status Register Byte 2 command (see "Write Status Register Byte 2" on page 40). To issue the Sector Lockdown command, the CS pin must first be asserted and then the opcode 33h must be clocked into the device followed by three address bytes designating any address within the 64KB sector to be locked down. After the three address bytes have been clocked in, a confirmation byte of D0h must also be clocked in immediately following the three address bytes. Any additional data clocked into the device after the first byte of data will be ignored. When the CS pin is deasserted, the Sector Lockdown Register corresponding to the sector addressed by A23-A0 will be set to the Logical 1 state, and the sector itself will then be permanently locked down from program and erase operations within a time of tLOCK. In addition, the WEL bit in the Status Register will be reset back to the Logical 0 state. The three complete address bytes and the correct confirmation byte value of D0h must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation. When the device aborts the Sector Lockdown operation, the state of the corresponding Sector Lockdown Register, as well as the SLE bit in the Status Register, will be unchanged; however, the WEL bit in the Status Register will be reset to a Logical 0. As a safeguard against accidental or erroneous locking down of sectors, the Sector Lockdown command can be enabled and disabled as needed by using the SLE bit in the Status Register. In addition, the current sector lockdown state can be frozen so that no further modifications to the Sector Lockdown Registers can be made (see "Freeze Sector Lockdown State" ). If the Sector Lockdown command is disabled, or if the sector lockdown state is frozen, then any attempts to issue the Sector Lockdown command will be ignored and the device will reset the WEL bit in the Status Register back to a Logical 0 and return to the idle state once the CS pin has been deasserted. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 29 Figure 10-1. Sector Lockdown CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK Opcode SI 0 0 1 1 0 Address Bits A23-A0 0 1 1 A MSB SO 10.2 A A A A Confirmation Byte In A MSB 1 1 0 1 0 0 0 0 MSB High-impedance Freeze Sector Lockdown State The current sector lockdown state can be permanently frozen so that no further modifications to the Sector Lockdown Registers can be made; therefore, the Sector Lockdown command will be permanently disabled and no additional sectors can be locked down aside from those already locked down. Any attempts to issue the Sector Lockdown command after the sector lockdown state has been frozen will be ignored. Before the Freeze Sector Lockdown State command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. In addition, the Sector Lockdown Enabled (SLE) bit in the Status Register must have also been previously set to the Logical 1 state. To issue the Freeze Sector Lockdown State command, the CS pin must first be asserted and then the opcode 34h must be clocked into the device, followed by three command-specific address bytes of 55AA40h. After the three address bytes have been clocked in, a confirmation byte of D0h must be clocked in immediately following the three address bytes. Any additional data clocked into the device will be ignored. When the CS pin is deasserted, the current sector lockdown state will be permanently frozen within a time of tLOCK. In addition, the WEL bit in the Status Register will be reset back to the Logical 0 state, and the SLE bit will be permanently reset to a Logical 0 to indicate that the Sector Lockdown command is permanently disabled. The three complete and correct address bytes and the confirmation byte must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation. When the device aborts the Freeze Sector Lockdown State operation, the WEL bit in the Status Register will be reset to a Logical 0; however, the state of the SLE bit will be unchanged. Figure 10-2. Freeze Sector Lockdown State CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK Opcode SI 0 0 1 1 0 MSB SO Address Bits A23-A0 1 0 0 0 MSB 1 0 0 0 Confirmation Byte In 0 1 1 0 1 0 0 0 0 MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 30 10.3 Read Sector Lockdown Registers The Sector Lockdown Registers can be read to determine the current lockdown status of each physical 64KB sector. To read the Sector Lockdown Register for a particular 64KB sector, the CS pin must first be asserted and then the opcode 35h must be clocked in. Once the opcode has been clocked in, three address bytes designating any address within the 64KB sector must be clocked in. After the address bytes have been clocked in, data will be output on the SO pin during every subsequent clock cycle. The data being output will be a repeating byte of either FFh or 00h to denote the value of the appropriate Sector Lockdown Register. At clock frequencies above fCLK, the first byte of data output will not be valid. Therefore, if operating at clock frequencies above fCLK, at least two bytes of data must be clocked out from the device in order to determine the correct status of the appropriate Sector Lockdown Register. Table 10-2. Read Sector Lockdown Register - Output Data Output Data Sector Lockdown Register Value 00h Sector Lockdown Register value is 0 (sector is not locked down). FFh Sector Lockdown Register value is 1 (sector is permanently locked down). Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 10-3. Read Sector Lockdown Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 SCK Opcode SI 0 0 1 1 0 MSB Address Bits A23-A0 1 0 1 A MSB A A A A A A Don't Care A A X X X X X X X X MSB Data Byte SO High-impedance D MSB D D D D D D D D D MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 31 10.4 Program OTP Security Register The device contains a specialized OTP (One-Time Programmable) Security Register that can be used for purposes such as unique device serialization, system-level Electronic Serial Number (ESN) storage, locked key storage, etc. The OTP Security Register is independent of the main Flash memory array and is comprised of a total of 128 bytes of memory divided into two portions. The first 64 bytes (byte locations 0 through 63) of the OTP Security Register are allocated as a one-time user-programmable space. Once these 64 bytes have been programmed, they cannot be erased or reprogrammed. The remaining 64 bytes of the OTP Security Register (byte locations 64 through 127) are factory programmed by Adesto(R) and will contain a unique value for each device. The factory programmed data is fixed and cannot be changed. Table 10-3. OTP Security Register Security Register Byte Number 0 1 ... 62 One-Time User Programmable 63 64 65 ... 126 127 Adesto Factory Programmed The user-programmable portion of the OTP Security Register does not need to be erased before it is programmed. In addition, the Program OTP Security Register command operates on the entire 64-byte, user-programmable portion of the OTP Security Register at one time. Once the user-programmable space has been programmed with any number of bytes, the user-programmable space cannot be programmed again. Therefore, it is not possible to program only the first two bytes of the register and then program the remaining 62 bytes at a later time. Before the Program OTP Security Register command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. To program the OTP Security Register, the CS pin must first be asserted and then the opcode 9Bh must be clocked into the device, followed by the three address bytes denoting the location of the first byte of the OTP Security Register to begin programming at. Since the size of the user-programmable portion of the OTP Security Register is 64 bytes, the upper order address bits do not need to be decoded by the device. Therefore, address bits A23-A6 will be ignored by the device and their values can be either a Logical 1 or 0. After the address bytes have been clocked in, data can then be clocked into the device and stored in the internal buffer. If the starting memory address denoted by A23-A0 does not start at the beginning of the OTP Security Register memory space (A5-A0 are not all 0), then special circumstances regarding which OTP Security Register locations are to be programmed will apply. In this situation, any data sent to the device that goes beyond the end of the 64-byte userprogrammable space will wrap around back to the beginning of the OTP Security Register. In addition, if more than 64 bytes of data are sent to the device, then only the last 64 bytes sent will be latched into the internal buffer. Example: If the starting address denoted by A23-A0 is 00003Eh, and three bytes of data are sent to the device, then the first two bytes of data will be programmed at OTP Security Register addresses 00003Eh and 00003Fh while the last byte of data will be programmed at address 000000h. The remaining bytes in the OTP Security Register (addresses 000001h through 00003Dh) will not be programmed and will remain in the erased state (FFh). When the CS pin is deasserted, the device will take the data stored in the internal buffer and program it into the appropriate OTP Security Register locations based on the starting address specified by A23-A0 and the number of data bytes sent to the device. If fewer than 64 bytes of data are sent to the device, then the remaining bytes within the OTP Security Register will not be programmed and will remain in the erased state (FFh). The programming of the data bytes is internally self-timed should take place in a time of tOTPP. It is not possible to suspend the programming of the OTP Security Register. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 32 The three address bytes and at least one complete byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation and the user-programmable portion of the OTP Security Register will not be programmed. The WEL bit in the Status Register will be reset back to the Logical 0 state if the OTP Security Register program cycle aborts due to an incomplete address being sent, an incomplete byte of data being sent, the CS pin being deasserted on uneven byte boundaries, or because the user-programmable portion of the OTP Security Register was previously programmed. While the device is programming the OTP Security Register, the Status Register can be read and will indicate that the device is busy. For faster throughput, it is recommended that the Status Register be polled rather than waiting the tOTPP time to determine if the data bytes have finished programming. At some point before the OTP Security Register programming completes, the WEL bit in the Status Register will be reset back to the Logical 0 state. If the device is powered down during the OTP Security Register program cycle, then the contents of the 64-byte, user-programmable portion of the OTP Security Register cannot be guaranteed and cannot be programmed again. The Program OTP Security Register command utilizes the 256-byte internal buffer for processing. Therefore, the contents of the buffer will be altered from its previous state when this command is issued. Figure 10-4. Program OTP Security Register CS 0 1 2 3 4 5 6 7 8 9 29 30 31 32 33 34 35 36 37 38 39 SCK Opcode SI 1 0 0 1 1 MSB SO Address Bits A23-A0 0 1 1 A MSB A A A A Data In Byte 1 A D MSB D D D D D Data In Byte n D D D D D D D D D D MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 33 10.5 Read OTP Security Register The OTP Security Register can be sequentially read in a similar fashion to the Read Array operation up to the maximum clock frequency specified by fMAX. To read the OTP Security Register, the CS pin must first be asserted and then the opcode 77h must be clocked into the device. After the opcode has been clocked in, the three address bytes must be clocked in to specify the starting address location of the first byte to read within the OTP Security Register. Following the three address bytes, two dummy bytes must be clocked into the device before data can be output. After the three address bytes and the dummy bytes have been clocked in, additional clock cycles will result in OTP Security Register data being output on the SO pin. When the last byte (00007Fh) of the OTP Security Register has been read, the device will continue reading from the beginning of the register (000000h). No delays will be incurred when wrapping around from the end of the register to the beginning of the register. Deasserting the CS pin will terminate the read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Figure 10-5. Read OTP Security Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 29 30 31 32 33 34 35 36 SCK Opcode SI 0 1 1 1 0 MSB Address Bits A23-A0 1 1 1 A MSB A A A A A A Don't Care A A X X X X X X X X X MSB Data Byte 1 SO High-impedance D MSB D D D D D D D D D MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 34 11. Status Register Commands 11.1 Read Status Register The two-byte Status Register can be read to determine the device's ready/busy status, as well as the status of many other functions such as hardware locking and software protection. The Status Register can be read at any time, including during an internally self-timed program or erase operation. To read the Status Register, the CS pin must first be asserted and then the opcode 05h must be clocked into the device. After the opcode has been clocked in, the device will begin outputting Status Register data on the SO pin during every subsequent clock cycle. After the second byte of the Status Register has been clocked out, the sequence will repeat itself, starting again with the first byte of the Status Register, as long as the CS pin remains asserted and the clock pin is being pulsed. The data in the Status Register is constantly being updated, so each repeating sequence may output new data. The RDY/BSY status is available for both bytes of the Status Register and is updated for each byte. At clock frequencies above fCLK, the first two bytes of data output from the Status Register will not be valid. Therefore, if operating at clock frequencies above fCLK, at least four bytes of data must be clocked out from the device in order to read the correct values of both bytes of the Status Register. Deasserting the CS pin will terminate the Read Status Register operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Table 11-1. Status Register Format - Byte 1 Bit(1) Name Type(2) 7 SPRL Sector Protection Registers Locked 6 RES Reserved for future use R 5 EPE Erase/Program Error R 4 WPP Write Protect (WP) Pin Status R 3:2 SWP 1 WEL 0 RDY/BSY Notes: 1. 2. Software Protection Status R/W R Write Enable Latch Status R Ready/Busy Status R Description 0 Sector Protection Registers are unlocked (default) 1 Sector Protection Registers are locked 0 Reserved for future use 0 Erase or program operation was successful 1 Erase or program error detected 0 WP is asserted 1 WP is deasserted 00 All sectors are software unprotected (all Sector Protection Registers are 0) 01 Some sectors are software protected. Read individual Sector Protection Registers to determine which sectors are protected. 10 Reserved for future use 11 All sectors are software protected (all Sector Protection Registers are 1 - default) 0 Device is not Write Enabled (default) 1 Device is Write Enabled 0 Device is ready 1 Device is busy with an internal operation Only bit 7 of Status Register Byte 1 will be modified when using the Write Status Register Byte 1 command. R/W = Readable and Writeable R = Readable only AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 35 Table 11-2. Status Register Format - Byte 2 Bit(1) Name Type(2) Description 7 RES Reserved for future use R 0 Reserved for future use 6 RES Reserved for future use R 0 Reserved for future use 5 RES Reserved for future use R 0 Reserved for future use 4 RSTE 0 Reset command is disabled (default) 1 Reset command is enabled 0 Sector Lockdown and Freeze Sector Lockdown State commands are disabled (default) 1 Sector Lockdown and Freeze Sector Lockdown State commands are enabled 0 No sectors are program suspended (default) 1 A sector is program suspended 0 No sectors are erase suspended (default) 1 A sector is erase suspended 0 Device is ready 1 Device is busy with an internal operation 3 SLE Reset Enabled Sector Lockdown Enabled R/W R/W 2 PS Program Suspend Status R 1 ES Erase Suspend Status R 0 RDY/BSY Ready/Busy Status R Notes: 1. 2. Only bits 4 and 3 of Status Register Byte 2 will be modified when using the Write Status Register Byte 2 command. R/W = Readable and Writeable R = Readable only 11.1.1 SPRL Bit The SPRL bit is used to control whether the Sector Protection Registers can be modified or not. When the SPRL bit is in the Logical 1 state, all Sector Protection Registers are locked and cannot be modified with the Protect Sector and Unprotect Sector commands (the device will ignore these commands). In addition, the Global Protect and Global Unprotect features cannot be performed. Any sectors that are presently protected will remain protected and any sectors that are presently unprotected will remain unprotected. When the SPRL bit is in the Logical 0 state, all Sector Protection Registers are unlocked and can be modified (the Protect Sector and Unprotect Sector commands, as well as the Global Protect and Global Unprotect features, will be processed as normal). The SPRL bit defaults to the Logical 0 state after device power-up. The Reset command has no effect on the SPRL bit. The SPRL bit can be modified freely whenever the WP pin is deasserted. However, if the WP pin is asserted, then the SPRL bit may only be changed from a Logical 0 (Sector Protection Registers are unlocked) to a Logical 1 (Sector Protection Registers are locked). In order to reset the SPRL bit back to a Logical 0 using the Write Status Register Byte 1 command, the WP pin has to first be deasserted. The SPRL bit is the only bit of Status Register Byte 1 that can be user modified via the Write Status Register Byte 1 command. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 36 11.1.2 EPE Bit The EPE bit indicates whether the last erase or program operation completed successfully or not. If at least one byte during the erase or program operation did not erase or program properly, then the EPE bit will be set to the Logical 1 state. The EPE bit will not be set if an erase or program operation aborts for any reason such as an attempt to erase or program a protected region or a locked down sector, an attempt to erase or program a suspended sector, or if the WEL bit is not set prior to an erase or program operation. The EPE bit is updated after every erase and program operation. 11.1.3 WPP Bit The WPP bit can be read to determine if the WP pin has been asserted or not. 11.1.4 SWP Bits The SWP bits provide feedback on the software protection status for the device. There are three possible combinations of the SWP bits that indicate whether none, some, or all of the sectors have been protected using the Protect Sector command or the Global Protect feature. If the SWP bits indicate that some of the sectors have been protected, then the individual Sector Protection Registers can be read with the Read Sector Protection Registers command to determine which sectors are in fact protected. 11.1.5 WEL Bit The WEL bit indicates the current status of the internal Write Enable Latch. When the WEL bit is in the Logical 0 state, the device will not accept any Byte/Page Program, Erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, Write Status Register, or Write Configuration Register commands. The WEL bit defaults to the Logical 0 state after a device Power-up or Reset operation. In addition, the WEL bit will be reset to the Logical 0 state automatically under the following conditions: Write Disable operation completes successfully Write Status Register operation completes successfully or aborts Write Configuration Register operation completes successfully or aborts Protect Sector operation completes successfully or aborts Unprotect Sector operation completes successfully or aborts Sector Lockdown operation completes successfully or aborts Freeze Sector Lockdown State operation completes successfully or aborts Program OTP Security Register operation completes successfully or aborts Byte/Page Program operation completes successfully or aborts Block Erase operation completes successfully or aborts Chip Erase operation completes successfully or aborts Hold condition aborts If the WEL bit is in the Logical 1 state, it will not be reset to a Logical 0 if an operation aborts due to an incomplete or unrecognized opcode being clocked into the device before the CS pin is deasserted. In order for the WEL bit to be reset when an operation aborts prematurely, the entire opcode for a Byte/Page Program, Erase, Protect Sector, Unprotect Sector, Sector Lockdown, Freeze Sector Lockdown State, Program OTP Security Register, Write Status Register, or Write Configuration Register command must have been clocked into the device. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 37 11.1.6 RSTE Bit The RSTE bit is used to enable or disable the Reset command. When the RSTE bit is in the Logical 0 state (the default state after power-up), the Reset command is disabled and any attempts to reset the device using the Reset command will be ignored. When the RSTE bit is in the Logical 1 state, the Reset command is enabled. The RSTE bit will retain its state as long as power is applied to the device. Once set to the Logical 1 state, the RSTE bit will remain in that state until it is modified using the Write Status Register Byte 2 command or until the device has been power cycled. The Reset command itself will not change the state of the RSTE bit. 11.1.7 SLE Bit The SLE bit is used to enable and disable the Sector Lockdown and Freeze Sector Lockdown State commands. When the SLE bit is in the Logical 0 state (the default state after power-up), the Sector Lockdown and Freeze Sector Lockdown commands are disabled. If the Sector Lockdown and Freeze Sector Lockdown commands are disabled, then any attempts to issue the commands will be ignored. This provides a safeguard for these commands against accidental or erroneous execution. When the SLE bit is in the Logical 1 state, the Sector Lockdown and Freeze Sector Lockdown State commands are enabled. Unlike the WEL bit, the SLE bit does not automatically reset after certain device operations. Therefore, once set, the SLE bit will remain in the Logical 1 state until it is modified using the Write Status Register Byte 2 command or until the device has been power cycled. The Reset command has no effect on the SLE bit. If the Freeze Sector Lockdown State command has been issued, then the SLE bit will be permanently reset in the Logical 0 state to indicate that the Sector Lockdown command has been disabled. 11.1.8 PS Bit The PS bit indicates whether or not a sector is in the Program Suspend state. 11.1.9 ES Bit The ES bit indicates whether or not a sector is in the Erase Suspend state. 11.1.10 RDY/BSY Bit The RDY/BSY bit is used to determine whether or not an internal operation, such as a program or erase, is in progress. To poll the RDY/BSY bit to detect the completion of a program or erase cycle, new Status Register data must be continually clocked out of the device until the state of the RDY/BSY bit changes from a Logical 1 to a Logical 0. Figure 11-1. Read Status Register CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 SCK Opcode SI 0 0 0 0 0 1 0 1 MSB SO High-impedance Status Register Byte 1 D MSB D D D D D Status Register Byte 2 D D D MSB D D D D D Status Register Byte 1 D D D D D D D D D D MSB AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 38 11.2 Write Status Register Byte 1 The Write Status Register Byte 1 command is used to modify the SPRL bit of the Status Register and/or to perform a Global Protect or Global Unprotect operation. Before the Write Status Register Byte 1 command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. To issue the Write Status Register Byte 1 command, the CS pin must first be asserted and then the opcode 01h must be clocked into the device followed by one byte of data. The one byte of data consists of the SPRL bit value, a don't-care bit, four data bits to denote whether a Global Protect or Unprotect should be performed, and two additional don't-care bits (see Table 11-3). Any additional data bytes that are sent to the device will be ignored. When the CS pin is deasserted, the SPRL bit in the Status Register will be modified, and the WEL bit in the Status Register will be reset back to a Logical 0. The values of bits 5, 4, 3, and 2 and the state of the SPRL bit before the Write Status Register Byte 1 command was executed (the prior state of the SPRL bit) will determine whether or not a Global Protect or Global Unprotect will be performed. Please refer to "Global Protect/Unprotect" on page 25 for more details. The complete one byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation, the state of the SPRL bit will not change, no potential Global Protect or Unprotect will be performed, and the WEL bit in the Status Register will be reset back to the Logical 0 state. If the WP pin is asserted, then the SPRL bit can only be set to a Logical 1. If an attempt is made to reset the SPRL bit to a Logical 0 while the WP pin is asserted, then the Write Status Register Byte 1 command will be ignored, and the WEL bit in the Status Register will be reset back to the Logical 0 state. In order to reset the SPRL bit to a Logical 0, the WP pin must be deasserted. Table 11-3. Write Status Register Byte 1 Format Bit 7 Bit 6 SPRL X Bit 5 Bit 4 Bit 3 Global Protect/Unprotect Bit 2 Bit 1 Bit 0 X X Figure 11-2. Write Status Register Byte 1 CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCK Status Register In Byte 1 Opcode SI 0 0 0 0 0 MSB SO 0 0 1 D X D D D D X X MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 39 11.3 Write Status Register Byte 2 The Write Status Register Byte 2 command is used to modify the RSTE and SLE bits of the Status Register. Using the Write Status Register Byte 2 command is the only way to modify the RSTE and SLE bits in the Status Register during normal device operation, and the SLE bit can only be modified if the sector lockdown state has not been frozen. Before the Write Status Register Byte 2 command can be issued, the Write Enable command must have been previously issued to set the WEL bit in the Status Register to a Logical 1. To issue the Write Status Register Byte 2 command, the CS pin must first be asserted, and then the opcode 31h must be clocked into the device followed by one byte of data. The one byte of data consists of three don't-care bits, the RSTE bit value, the SLE bit value, and three additional don't-care bits (see Table 11-4). Any additional data bytes sent to the device will be ignored. When the CS pin is deasserted, the RSTE and SLE bits in the Status Register will be modified, and the WEL bit in the Status Register will be reset back to a Logical 0. The SLE bit will only be modified if the Freeze Sector Lockdown State command has not been previously issued. The complete one byte of data must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on even byte boundaries (multiples of eight bits); otherwise, the device will abort the operation, the state of the RSTE and SLE bits will not change, and the WEL bit in the Status Register will be reset back to the Logical 0 state. Table 11-4. Write Status Register Byte 2 Format Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X X X RSTE SLE X X X Figure 11-3. Write Status Register Byte 2 CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCK Status Register In Byte 2 Opcode SI 0 0 1 1 0 MSB SO 0 0 1 X X X D D X X X MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 40 12. Other Commands and Functions 12.1 Reset In some applications, it may be necessary to prematurely terminate a program or erase cycle rather than wait the hundreds of microseconds or milliseconds necessary for the program or erase operation to complete normally. The Reset command allows a program or erase operation in progress to be ended abruptly and returns the device to an idle state. Since the need to reset the device is immediate, the Write Enable command does not need to be issued prior to the Reset command. Therefore, the Reset command operates independently of the state of the WEL bit in the Status Register. The Reset command can be executed only if the command has been enabled by setting the Reset Enabled (RSTE) bit in the Status Register to a Logical 1. If the Reset command has not been enabled (the RSTE bit is in the Logical 0 state), then any attempts at executing the Reset command will be ignored. To perform a Reset, the CS pin must first be asserted, and then the opcode F0h must be clocked into the device. No address bytes need to be clocked in, but a confirmation byte of D0h must be clocked into the device immediately after the opcode. Any additional data clocked into the device after the confirmation byte will be ignored. When the CS pin is deasserted, the program or erase operation currently in progress will be terminated within a time of tRST. Since the program or erase operation may not complete before the device is reset, the contents of the page being programmed or the block being erased cannot be guaranteed to be valid. The Reset command has no effect on the states of the Sector Protection Registers, the Sector Lockdown Registers, the Configuration Register, or the SPRL, RSTE, and SLE bits in the Status Register. The WEL, PS, and ES bits of the Status Register, however, will be reset back to their default states. If a Reset operation is performed while a sector is erase suspended, the suspend operation will abort, and the contents of the block being erased in the suspended sector will be left in an undefined state. If a Reset is performed while a sector is program suspended, the suspend operation will abort, and the contents of the page that was being programmed and subsequently suspended will be undefined. The remaining pages in the 64KB sector will retain their previous contents. The complete opcode and confirmation byte must be clocked into the device before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, no Reset operation will be performed. Figure 12-1. Reset CS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 SCK Opcode SI 1 1 1 1 0 MSB SO Confirmation Byte In 0 0 0 1 1 0 1 0 0 0 0 MSB High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 41 12.2 Read Manufacturer and Device ID Identification information can be read from the device to enable systems to electronically query and identify the device while it is in the system. The identification method and the command opcode comply with the JEDEC standard for "Manufacturer and Device ID Read Methodology for SPI Compatible Serial Interface Memory Devices". The type of information that can be read from the device includes the JEDEC-defined Manufacturer ID, the vendor-specific Device ID, and the vendor-specific Extended Device Information. The Read Manufacturer and Device ID command is limited to a maximum clock frequency of fCLK. Since not all Flash devices are capable of operating at very high clock frequencies, applications should be designed to read the identification information from the devices at a reasonably low clock frequency to ensure that all devices to be used in the application can be identified properly. Once the identification process is complete, the application can then increase the clock frequency to accommodate specific Flash devices that are capable of operating at the higher clock frequencies. To read the identification information, the CS pin must first be asserted and then the opcode 9Fh must be clocked into the device. After the opcode has been clocked in, the device will begin outputting the identification data on the SO pin during the subsequent clock cycles. The first byte to be output will be the Manufacturer ID, followed by two bytes of Device ID information. The fourth byte output will be the Extended Device Information (EDI) String Length, which will be 01h indicating that one byte of EDI data follows. After the one byte of EDI data is output, the SO pin will go into a high-impedance state; therefore, additional clock cycles will have no affect on the SO pin and no data will be output. As indicated in the JEDEC standard, reading the EDI String Length and any subsequent data is optional. Deasserting the CS pin will terminate the Manufacturer and Device ID Read operation and put the SO pin into a high-impedance state. The CS pin can be deasserted at any time and does not require that a full byte of data be read. Table 12-1. Manufacturer and Device ID Information Byte No. Data Type Value 1 Manufacturer ID 1Fh 2 Device ID (Byte 1) 46h 3 Device ID (Byte 2) 03h 4 [Optional to Read] Extended Device Information (EDI) String Length 01h 5 [Optional to Read] EDI Byte 1 00h Table 12-2. Manufacturer and Device ID Details Data Type Manufacturer ID Device ID (Byte 1) Device ID (Byte 2) Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 1 1 1 0 1 1 JEDEC Assigned Code 0 0 0 1 1 1 Family Code 0 1 Density Code 0 0 0 Sub Code 0 0 1 Product Variant 0 0 0 0 Hex Value Details 1Fh JEDEC code: 0001 1111 (1Fh for Adesto) 46h Family code: Density code: 010 (SPI or Dual-I/O) 00110 (16-Mbit) 03h Sub code: 000 (Standard Series) Product variant: 00011 Table 12-3. EDI Data Byte Number 1 Bit 7 Bit 6 Bit 5 Bit 4 RFU 0 0 Bit 3 Bit 2 Bit 1 Bit 0 Device Revision 0 0 0 0 0 0 Hex Value 00h Details RFU: Device revision: Reserved for future use 00000 (Initial version) AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 42 Figure 12-2. Read Manufacturer and Device ID CS 0 6 7 8 14 15 16 22 23 24 30 31 32 38 39 40 46 SCK Opcode SI SO 9Fh High-impedance Note: Each transition 1Fh 46h 03h 01h 00h Manufacturer ID Device ID Byte 1 Device ID Byte 2 EDI String Length EDI Data Byte 1 shown for SI and SO represents one byte (8 bits). AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 43 12.3 Deep Power-Down During normal operation, the device will be placed in the standby mode to consume less power as long as the CS pin remains deasserted and no internal operation is in progress. The Deep Power-Down command offers the ability to place the device into an even lower power consumption state called the Deep Power-Down mode. When the device is in the Deep Power-Down mode, all commands including the Read Status Register command will be ignored with the exception of the Resume from Deep Power-Down command. Since all commands will be ignored, the mode can be used as an extra protection mechanism against program and erase operations. Entering the Deep Power-Down mode is accomplished by simply asserting the CS pin, clocking in the opcode B9h, and then deasserting the CS pin. Any additional data clocked into the device after the opcode will be ignored. When the CS pin is deasserted, the device will enter the Deep Power-Down mode within the maximum time of tEDPD. The complete opcode must be clocked in before the CS pin is deasserted, and the CS pin must be deasserted on an even byte boundary (multiples of eight bits); otherwise, the device will abort the operation and return to the standby mode once the CS pin is deasserted. In addition, the device will default to the standby mode after a power cycle. The Deep Power-Down command will be ignored if an internally self-timed operation such as a program or erase cycle is in progress. The Deep Power-Down command must be reissued after the internally self-timed operation has been completed in order for the device to enter the Deep Power-Down mode. Figure 12-3. Deep Power-Down CS tEDPD 0 1 2 3 4 5 6 7 SCK Opcode SI 1 0 1 1 1 0 0 1 MSB SO High-impedance Active Current ICC Standby Mode Current Deep Power-Down Mode Current AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 44 12.4 Resume from Deep Power-Down In order to exit the Deep Power-Down mode and resume normal device operation, the Resume from Deep Power-Down command must be issued. The Resume from Deep Power-Down command is the only command that the device will recognize while in the Deep Power-Down mode. To resume from the Deep Power-Down mode, the CS pin must first be asserted and then the opcode ABh must be clocked into the device. Any additional data clocked into the device after the opcode will be ignored. When the CS pin is deasserted, the device will exit the Deep Power-Down mode and return to the standby mode within the maximum time of tRDPD. After the device has returned to the standby mode, normal command operations such as Read Array can be resumed. If the complete opcode is not clocked in before the CS pin is deasserted, or if the CS pin is not deasserted on an even byte boundary (multiples of eight bits), then the device will abort the operation and return to the Deep Power-Down mode. Figure 12-4. Resume from Deep Power-Down CS tRDPD 0 1 2 3 4 5 6 7 SCK Opcode SI 1 0 1 0 1 0 1 1 MSB SO High-impedance Active Current ICC Deep Power-Down Mode Current Standby Mode Current AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 45 12.5 Hold The HOLD pin is used to pause the serial communication with the device without having to stop or reset the clock sequence. The Hold mode, however, does not have an affect on any internally self-timed operations such as a program or erase cycle. Therefore, if an erase cycle is in progress, asserting the HOLD pin will not pause the operation and the erase cycle will continue until it is finished. The Hold mode can only be entered while the CS pin is asserted. The Hold mode is activated simply by asserting the HOLD pin during the SCK low pulse. If the HOLD pin is asserted during the SCK high pulse, then the Hold mode won't be started until the beginning of the next SCK low pulse. The device will remain in the Hold mode as long as the HOLD pin and CS pin are asserted. While in the Hold mode, the SO pin will be in a high-impedance state. In addition, both the SI pin and the SCK pin will be ignored. The WP pin, however, can still be asserted or deasserted while in the Hold mode. To end the Hold mode and resume serial communication, the HOLD pin must be deasserted during the SCK low pulse. If the HOLD pin is deasserted during the SCK high pulse, then the Hold mode won't end until the beginning of the next SCK low pulse. If the CS pin is deasserted while the HOLD pin is still asserted, then any operation that may have been started will be aborted and the device will reset the WEL bit in the Status Register back to the Logical 0 state. Figure 12-5. Hold Mode CS SCK HOLD Hold Hold Hold AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 46 13. RapidS Implementation To implement RapidS and operate at clock frequencies higher than what can be achieved in a viable SPI implementation, a full clock cycle can be used to transmit data back and forth across the serial bus. The AT25DL161 is designed to always clock its data out on the falling edge of the SCK signal and clock data in on the rising edge of SCK. For full clock cycle operation to be achieved, when the AT25DL161 is clocking data out on the falling edge of SCK, the host controller should wait until the next falling edge of SCK to latch the data in. Similarly, the host controller should clock its data out on the rising edge of SCK in order to give the AT25DL161 a full clock cycle to latch the incoming data in on the next rising edge of SCK. Implementing RapidS allows a system to run at higher clock frequencies since a full clock cycle is used to accommodate a device's clock-to-output time, input setup time, and associated rise/fall times. Example: If the system clock frequency is 100MHz (10ns cycle time) with a 50% duty cycle, and the host controller has an input setup time of 2ns, then a standard SPI implementation would require that the slave device be capable of outputting its data in less than 3ns to meet the 2ns host controller setup time [(10ns x 50%) - 2ns] not accounting for rise/fall times. In an SPI Mode 0 or 3 implementation, the SPI Master is designed to clock in data on the next immediate rising edge of SCK after the SPI slave has clocked its data out on the preceding falling edge. This essentially makes SPI a half-clock cycle protocol and requires extremely fast clock-to-output times and input setup times in order to run at high clock frequencies. With a RapidS implementation of this example, however, the full 10ns cycle time is available which gives the slave device up to 8ns, not accounting for rise/fall times, to clock its data out. Likewise, with RapidS, the host controller has more time available to output its data to the slave since the slave device would be clocking that data in a full clock cycle later. Figure 13-1. RapidS Operation Slave CS 1 8 2 3 4 5 6 1 8 7 2 3 4 5 6 1 7 SCK B A MOSI C tV E D MSB LSB BYTE A H G I F MISO MSB LSB BYTE B MOSI = Master Out, Slave In MISO = Master In, Slave Out The Master is the ASIC/MCU and the Slave is the memory device. The Master always clocks data out on the rising edge of SCK and always clocks data in on the falling edge of SCK. The Slave always clocks data out on the falling edge of SCK and always clocks data in on the rising edge of SCK. A. B. C. D. E. F. G. H. I. Master clocks out first bit of BYTE A on the rising edge of SCK. Slave clocks in first bit of BYTE A on the next rising edge of SCK. Master clocks out second bit of BYTE A on the same rising edge of SCK. Last bit of BYTE A is clocked out from the Master. Last bit of BYTE A is clocked into the slave. Slave clocks out first bit of BYTE B. Master clocks in first bit of BYTE B. Slave clocks out second bit of BYTE B. Master clocks in last bit of BYTE B. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 47 14. Electrical Specifications 14.1 Absolute Maximum Ratings* Temperature under Bias . . . . . . . . . . -55C to +125C *Notice: Storage Temperature. . . . . . . . . . . . . -65C to +150C All input voltages (including NC pins) with respect to ground . . . . . . . . . . . . . . -0.6V to +4.1V All output voltages with respect to ground . . . . . . . . . .-0.6V to VCC + 0.5V 14.2 Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. Functional operation of the device at these ratings or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Voltage extremes referenced in the "Absolute Maximum Ratings" are intended to accommodate short duration undershoot/overshoot conditions, and does not imply or guarantee functional device operation at these levels for any extended period of time. DC and AC Operating Range AT25DL161 Operating Temperature (case) Ind. -40C to 85C VCC Power Supply 14.3 1.65V to 1.95V DC Characteristics Symbol Parameter ISB Standby Current IDPD Deep Power-Down Current Condition Min CS, WP, HOLD = VCC, all inputs at CMOS levels CS, WP, HOLD = VCC, all inputs at CMOS levels f = 100MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 85MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 66MHz; IOUT = 0mA; ICC1 Active Current, Read Operation CS = VIL, VCC = Max Typ Max Units 25 35 A 8 10 A 14 20 14 20 13 18 13 17 12 16 10 15 mA f = 50MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 33MHz; IOUT = 0mA; CS = VIL, VCC = Max f = 20MHz; IOUT = 0mA; CS = VIL, VCC = Max ICC2 Active Current, Program Operation CS = VCC, VCC = Max 17 22 mA ICC3 Active Current, Erase Operation CS = VCC, VCC = Max 14 22 mA ILI Input Leakage Current VIN = CMOS levels 1 A ILO Output Leakage Current VOUT = CMOS levels 1 A VIL Input Low Voltage 0.2 x VCC V VIH Input High Voltage VOL Output Low Voltage IOL = 1.6mA; VCC = Min VOH Output High Voltage IOH = -100A; VCC = Min 0.8 x VCC V 0.2 VCC - 0.2V V V AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 48 14.4 AC Characteristics - Maximum Clock Frequencies Symbol Parameter Min Max Units RapidS and SPI Operation 14.5 fMAX Maximum clock frequency for all operations - RapidS operation only (excluding 03h, 0Bh, 3Bh, and 9Fh opcodes) 100 MHz fCLK Maximum clock frequency for all operations (excluding 03h opcode) 85 MHz fRDLF Maximum clock frequency for 03h opcode (Read Array - Low Frequency) 40 MHz fRDDO Maximum clock frequency for 3Bh opcode (Dual-Output Read) 66 MHz Max Units AC Characteristics - All Other Parameters Symbol Parameter Min tCLKH Clock High Time 4.3 ns Clock Low Time 4.3 ns tCLKL tCLKR (1) Clock Rise Time, Peak-to-peak (Slew Rate) 0.1 V/ns tCLKF(1) Clock Fall Time, Peak-to-peak (Slew Rate) 0.1 V/ns tCSH Chip Select High Time 30 ns tCSLS Chip Select Low Setup Time (Relative to Clock) 5 ns tCSLH Chip Select Low Hold Time (Relative to Clock) 5 ns tCSHS Chip Select High Setup Time (Relative to Clock) 5 ns tCSHH Chip Select High Hold Time (Relative to Clock) 5 ns tDS Data in Setup Time 2 ns tDH Data in Hold Time 1 ns tDIS(1) Output Disable Time tV(2) Output Valid Time tOH Output Hold Time 2 ns tHLS HOLD Low Setup Time (Relative to Clock) 5 ns tHLH HOLD Low Hold Time (Relative to Clock) 5 ns tHHS HOLD High Setup Time (Relative to Clock) 5 ns tHHH HOLD High Hold Time (Relative to Clock) 5 ns tHLQZ(1) HOLD Low to Output High-Z tHHQX(1) HOLD High to Output Low-Z tWPS(1)(3) Write Protect Setup Time 20 ns Write Protect Hold Time 100 ns tWPH (1)(3) tSECP(1) 5 ns 5 ns 5 ns 5 ns Sector Protect Time (from Chip Select High) 20 ns tSECUP Sector Unprotect Time (from Chip Select High) 20 ns tLOCK(1) Sector Lockdown and Freeze Sector Lockdown State Time (from Chip Select High) 200 s (1) tEDPD (1) Chip Select High to Deep Power-Down 3 s tRDPD(1) Chip Select High to Standby Mode 35 s tRST Reset Time 30 s Notes: 1. Not 100% tested (value guaranteed by design and characterization). 2. 15pF load at frequencies above 70MHz, 30pF otherwise. 3. Only applicable as a constraint for the Write Status Register Byte 1 command when SPRL = 1. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 49 14.6 Program and Erase Characteristics Symbol Parameter tPP(1) Page Program Time (256 bytes) tBP Byte Program Time tBLKE(1) tCHPE(1)(2) Chip Erase Time tSUSP Suspend Time tRES Resume Time tOTPP(1) OTP Security Register Program Time tWRSR(2) Write Status Register Time 2. 14.8 Typ Max Units 1.0 3.0 ms 8 Block Erase Time Notes: 1. 14.7 Min s 4KB 50 200 32KB 250 600 64KB 550 950 16 28 Program 10 20 Erase 25 40 Program 10 20 Erase 12 20 200 500 s 200 ns Max Units ms sec s s Maximum values indicate worst-case performance after 100,000 erase/program cycles. Not 100% tested (value guaranteed by design and characterization). Power-up Conditions Symbol Parameter Min tVCSL Minimum VCC to Chip Select Low Time 70 tPUW Power-up Device Delay Before Program or Erase Allowed VPOR Power-on Reset Voltage 1.2 s 10 ms 1.55 V Input Test Waveforms and Measurement Levels AC Driving Levels 0.9VCC VCC/2 0.1VCC AC Measurement Level tR, tF < 2ns (10% to 90%) 14.9 Output Test Load Device Under Test 15pF (frequencies above 70MHz) or 30pF AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 50 15. AC Waveforms Figure 15-1. Serial Input Timing tCSH CS tCSLH tCLKL tCSLS tCLKH tCSHH tCSHS SCK tDS tDH SI SO MSB LSB MSB High-impedance Figure 15-2. Serial Output Timing CS tCLKH tCLKL tDIS SCK SI tOH tV tV SO Figure 15-3. WP Timing for Write Status Register Byte 1 Command When SPRL = 1 CS tWPH tWPS WP SCK SI 0 MSB of Write Status Register Byte 1 Opcode SO 0 0 X MSB LSB of Write Status Register Data Byte MSB of Next Opcode High-impedance AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 51 Figure 15-4. HOLD Timing - Serial Input CS SCK tHHH tHLS tHLH tHHS tHLH tHHS HOLD SI SO High-impedance Figure 15-5. HOLD Timing - Serial Output CS SCK tHHH tHLS HOLD SI tHLQZ tHHQX SO AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 52 16. Ordering Information 16.1 Ordering Code Detail AT 2 5DL 1 6 1 - SSH N -B Designator Shipping Carrier Option B = Bulk (tubes) Y = Bulk (trays) T = Tape and reel Product Family Operating Voltage N = 1.65V minimum (1.65V to 1.95V) Device Density Device Grade 16 = 16-megabit H = Green, NiPdAu lead finish, Industrial temperature range (-40C to +85C) U = Green, Matte Sn or Sn alloy, Industrial temperature range (-40C to +85C) Interface 1 = Serial Package Option SS = 8-lead, 0.150" wide SOIC M = 8-pad, 5 x 6 x 0.6mm UDFN 16.2 Green Package Options (Pb/halide-free/RoHS-compliant) Adesto Ordering Codes AT25DL161-SSHN-B Operating Voltage Max. Freq. (MHz) NiPdAu 1.65V to 1.95V 100 8S1 (1) AT25DL161-MHN-T(1) Notes: 1. Lead (Pad) Finish Operation Range (1) AT25DL161-SSHN-T(1) AT25DL161-MHN-Y Package 8MA1 Industrial (-40C to +85C) The shipping carrier option code is not marked on the devices. Package Type 8S1 8-lead 0.150"-wide, Plastic, Gull Wing, Small Outline (JEDEC SOIC) 8MA1 8-pad (5 x 6 x 0.6mm body), Thermally Enhanced Plastic Ultra Thin Dual Flat No-lead (UDFN) AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 53 17. Packaging Information 17.1 8S1 -- 8-lead JEDEC SOIC C 1 E E1 L N O TOP VIEW END VIEW e b COMMON DIMENSIONS (Unit of Measure = mm) A A1 D SIDE VIEW Notes: This drawing is for general information only. Refer to JEDEC Drawing MS-012, Variation AA for proper dimensions, tolerances, datums, etc. SYMBOL MIN A 1.35 NOM MAX - 1.75 A1 0.10 - 0.25 b 0.31 - 0.51 C 0.17 - 0.25 D 4.80 - 5.05 E1 3.81 - 3.99 E 5.79 - 6.20 e NOTE 1.27 BSC L 0.40 - 1.27 O 0 - 8 6/22/11 Package Drawing Contact: contact@adestotech.com TITLE 8S1, 8-lead (0.150" Wide Body), Plastic Gull Wing Small Outline (JEDEC SOIC) GPC SWB DRAWING NO. REV. 8S1 G AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 54 17.2 8MA1 -- 8-pad UDFN E C Pin 1 ID SIDE VIEW D y TOP VIEW A1 A K E2 0.45 8 Option A Pin #1 Chamfer (C 0.35) 1 Pin #1 Notch (0.20 R) (Option B) 7 2 e D2 6 3 COMMON DIMENSIONS (Unit of Measure = mm) SYMBOL MIN NOM MAX A 0.45 0.55 0.60 A1 0.00 0.02 0.05 b 0.35 0.40 0.48 C 5 b L BOTTOM VIEW 0.152 REF D 4 NOTE 4.90 5.00 5.10 D2 3.80 4.00 4.20 E 5.90 6.00 6.10 E2 3.20 3.40 3.60 e 1.27 L 0.50 0.60 0.75 y 0.00 - 0.08 K 0.20 - - 4/15/08 GPC TITLE Package Drawing Contact: contact@adestotech.com 8MA1, 8-pad (5 x 6 x 0.6 mm Body), Thermally Enhanced Plastic Ultra Thin Dual Flat No Lead Package (UDFN) YFG DRAWING NO. 8MA1 AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 REV. D 55 18. Revision History Doc. Rev. Date Comments 8795H 11/2017 Added patent information. 8795G 5/2017 Removed WLCSP package. 8795F 1/2013 Remove die size from dBGA package outline diagram 8795E 12/2012 Add labels to pins in dBGA package 8795D 12/2012 Update to Adesto. Removed preliminary status. 8795C 09/2012 Add WLCSP package drawing. Updated template and Adesto logo. Decreased IDPD maximum from 14A to 10A. 8795B 05/2012 Decreased FRDDO maximum from 85A to 66A. Various typopgraphical edits throughout document. 8795A 03/2012 Initial document release. AT25DL161 [DATASHEET] 8795H-DFLASH-11/2017 56 Corporate Office California | USA Adesto Headquarters 3600 Peterson Way Sanat Clara, CA 95054 Phone: (+1) 408.400.0578 Email: contact@adestotech.com (c) 2017 Adesto Technologies. All rights reserved. / Rev.: 8795H-DFLASH-11/2017 Adesto(R), the Adesto logo, CBRAM(R), and DataFlash(R) are registered trademarks or trademarks of Adesto Technologies. All other marks are the property of their respective owners. Adesto products in this datasheet are covered by certain Adesto patents registered in the United States and potentially other countries. Please refer to http://www.adestotech.com/patents for details. Disclaimer: Adesto Technologies Corporation makes no warranty for the use of its products, other than those expressly contained in the Company's standard warranty which is detailed in Adesto's Terms and Conditions located on the Company's web site. The Company assumes no responsibility for any errors which may appear in this document, reserves the right to change devices or specifications detailed herein at any time without notice, and does not make any commitment to update the information contained herein. No licenses to patents or other intellectual property of Adesto are granted by the Company in connection with the sale of Adesto products, expressly or by implication. Adesto's products are not authorized for use as critical components in life support devices or systems. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Adesto Technologies: AT25DL161-SSHN-B AT25DL161-SSHN-T AT25DL161-MHN-T AT25DL161-MHN-Y AT25DL161-UUN-T