DC/DC Converter
URA_ZP-6WR3 & URB_ZP-6WR3 Series
2019.10.15-A/5 Page 1 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
6W isolated DC-DC converter in DIP package
Ultra-wide input voltage and regulated dual/single
output
CB Patent Protection RoHS
FEATURES
Ultra-wide 4:1 range input voltage
High efficiency up to 88%
No-load power consumption as low as 0.12W
I/O test isolation voltage : 1.5k VDC
Operating ambient temperature range: -40to
+85
Input under-voltage protection, output
over-voltage, short circuit, over-current protection
Meet CISPR32/EN55032 CLASS A, without extra
components
Industry standard pin-out
UL60950, EN60950, IEC60950 approved
URA_ZP-6WR3 & URB_ZP-6WR3 series of isolated 6W DC-DC converter products with an ultra-wide range of voltage input of 9-36VDC,
18-75VDC, input to output isolation is tested with 1500VDC, output over-voltage protection and output short circuit protection. They meet
CLASS A of CISPR32/EN55032 EMI standards without external components and they are widely used in fields such as industrial control,
electric power, instruments and communication.
Selection Guide
Certification
Part No.
Input Voltage (VDC)
Output
Full Load Efficiency
(%) Min./Typ.
Nominal
(Range)
Max.
Voltage
VDC
Current (mA)
Max./Min.
UL/CE/CB
URA2405ZP-6WR3
24
(9-36)
40
±5
±600/0
81/83
URA2409ZP-6WR3
±9
±333/0
84/86
URA2412ZP-6WR3
±12
±250/0
85/87
URA2415ZP-6WR3
±15
±200/0
86/88
URA2424ZP-6WR3
±24
±125/0
85/87
URB2403ZP-6WR3
3.3
1500/0
77/79
URB2405ZP-6WR3
5
1200/0
81/83
URB2409ZP-6WR3
9
667/0
82/84
URB2412ZP-6WR3
12
500/0
85/87
URB2415ZP-6WR3
15
400/0
86/88
URB2424ZP-6WR3
24
250/0
85/87
URA4805ZP-6WR3
48
(18-75)
80
±5
±600/0
81/83
URA4812ZP-6WR3
±12
±250/0
85/87
URA4815ZP-6WR3
±15
±200/0
86/88
URB4803ZP-6WR3
3.3
1500/0
78/80
URB4805ZP-6WR3
5
1200/0
82/84
--
URB4809ZP-6WR3
9
667/0
83/85
UL/CE/CB
URB4812ZP-6WR3
12
500/0
85/87
URB4815ZP-6WR3
15
400/0
86/88
URB4824ZP-6WR3
24
250/0
85/87
Notes
1Exceeding the maximum input voltage may cause permanent damage;
2Efficiency is measured at nominal input voltage and rated output load;
3The specified maximum capacitive load value for Vo1 and Vo2 output is identical.
Input Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Input Current (full load /
no-load)
24VDC input
--
301/5
309/12
mA
48VDC input
--
148/4
154/8
Reflected Ripple Current
--
20
--
DC/DC Converter
URA_ZP-6WR3 & URB_ZP-6WR3 Series
2019.10.15-A/5 Page 2 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Surge Voltage (1sec. max.)
24VDC input
-0.7
--
50
VDC
48VDC input
-0.7
--
100
Start-up Voltage
24VDC input
--
--
9
VDC
48VDC input
--
--
18
Under-voltage turn-off
24VDC input
5.5
6.5
--
VDC
48VDC input
12
15.5
--
Input Filter
Pi filter
Hot Plug
Unavailable
Output Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Voltage Accuracy
Vo1
--
±1
±3
%
Vo2
Balance of Output Voltage
Dual output, balanced load
--
±0.5
±1.5
Linear Regulation
Input voltage variation from low to
high at full load
Vo1
--
±0.2
±0.5
Vo2
--
±0.5
±1
Load Regulation
5%-100% load
Vo1
--
±0.5
±1
Vo2
--
±0.5
±1.5
Cross Regulation
Dual outputs, Vo1 load at 50%, Vo2 load at range of
10%-100%
--
--
±5
Transient Recovery Time
25% load step change
--
300
500
µs
Transient Response Deviation
3.3V, 5V, ±5V
output
--
±5
±8
%
Others
--
±3
±5
Temperature Coefficient
Full load
--
--
±0.03
%/
Ripple&Noise
20MHz bandwidth
--
--
85
mV p-p
Over-voltage Protection
Input voltage range
110
--
160
%Vo
Over-current Protection
110
140
190
%Io
Short-circuit Protection
Continuous, self-recovery
Note: Output voltage accuracy of ±5VDC/±9VDC output converter for 0%-5% load is ±5% max;
Load regulation for 0%-100% load is ±5%;
The “parallel cable” method is used for ripple and noise test, please refer to
DC-DC Converter Application Notes
for specific information.
General Specifications
Item
Operating Conditions
Min.
Typ.
Max.
Unit
Isolation
Input-output Electric Strength Test for 1 minute with a
leakage current of 1mA max.
1500
--
--
VDC
Insulation Resistance
Input-output resistance at 500VDC
1000
--
--
MΩ
Isolation Capacitance
Input-output capacitance at 100KHz/0.1V
--
1000
--
pF
Operating Temperature
Derating if the temperature is 71°C (see Fig. 1)
-40
--
85
Storage Temperature
-55
--
125
Storage Humidity
Non-condensing
5
--
95
%RH
Pin Soldering Resistance
Temperature
Soldering spot is 1.5mm away from case for 10
seconds
--
--
300
Vibration
10-55Hz, 2G, 30 Min. along X, Y and Z
Switching Frequency *
PWM mode
--
300
--
KHz
MTBF
MIL-HDBK-217F@25
1000
--
--
K hours
Note*Switching frequency is measured at full load. The module reduces the switching frequency for light load (below 50%) efficiency improvement.
DC/DC Converter
URA_ZP-6WR3 & URB_ZP-6WR3 Series
2019.10.15-A/5 Page 3 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Mechanical Specifications
Case Material
Aluminum alloy
Dimensions
32.00 × 20.00 × 10.80mm
Weight
12.0g(Typ.)
Cooling Method
Free air convection
Electromagnetic Compatibility (EMC)
Emissions
CE
CISPR32/EN55032 CLASS A (without extra components)/ CLASS B (see Fig.3-for
recommended circuit)
RE
CISPR32/EN55032 CLASS A (without extra components)/ CLASS B (see Fig.3-for
recommended circuit)
Immunity
ESD
IEC/EN61000-4-2 Contact ±4KV
perf. Criteria B
RS
IEC/EN61000-4-3 10V/m
perf. Criteria A
EFT
IEC/EN61000-4-4 ±2KV (see Fig.3-for recommended circuit)
perf. Criteria B
Surge
IEC/EN61000-4-5 ±2KV (see Fig.3-for recommended circuit)
perf. Criteria B
CS
IEC/EN61000-4-6 3 Vr.m.s
perf. Criteria A
Immunities of voltage dip,
drop and short interruption
IEC/EN61000-4-29 0-70%
perf. Criteria B
Product Characteristic Curve
Operating Temperat ure( )
Temperature Derating Curve
Output Power Percentage(%)
Safe Operating Area
-40 0 40 71 8 5 120
80
60
100
120
40
20
0
Fig. 1
DC/DC Converter
URA_ZP-6WR3 & URB_ZP-6WR3 Series
2019.10.15-A/5 Page 4 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Design Reference
1. Typical application
All the DC/DC converters of this series are tested before delivery using the recommended circuit shown in Fig. 2.
Input and/or output ripple can be further reduced by appropriately increasing the input & output capacitor values Cin and Cout and/or by
selecting capacitors with a low ESR (equivalent series resistance). Also make sure that the capacitance is not exceeding the specified max.
capacitive load value of the product.
DC DC
Vin
GND
+Vo
0V
Cin
Cout
Vin
GND
+Vo
0V
Cin
Cout
DC DC
-Vo
Cout
Dual
Single
Fig. 2
Vin(VDC)
Cin
Cout
24
100µF
10µF
48
10µF ~47µF
10µF
2. EMC compliance circuit
Dual output:
Single output:
Fig. 3
Notes: For EMC tests we use Part in Fig. 3 for immunity and part
for emissions test. Selecting based on needs.
Parameter description:
Model
Vin:24V
Vin:48V
FUSE
Choose according to actual input current
C0, C3
330µF/50V
330µF/100V
C1
1µF/50V
1µF/100V
C2
Refer to the Cout in Fig.2
LDM1
4.7µH
CY1, CY2
1nF/2KV
3. The products do not support parallel connection of their output
4. For additional information please refer to DC-DC converter application notes on
www.mornsun-power.com
DC/DC Converter
URA_ZP-6WR3 & URB_ZP-6WR3 Series
2019.10.15-A/5 Page 5 of 5
MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
Dimensions and Recommended Layout
NC: No Connection
Dual
Single
2223
2 3 11
16 14
1.00 [
0.039]
2223
2 3 11
16 14
9
Note:Grid 2.54*2.54mm
Pin Single
2,3 GND
No Pin
NC
+Vo
0V
Vin
9
11
14
16
22,23
Dual
GND
+Vo
0V
Vin
Pin-Out
0V
-Vo
1102001602-B0
THIRD ANGLE PROJECTION
Bottom View
Front View
23 22 1416
9 1132
2.54 [0.100]
32.00 [1.260]
20.00 [0.787]
15.24 [0.600]
5.08 [0.200]
22.86 [0.900]
0.50[0.020]
4.10 [0.161]
10.80 [0.425]
Note:
Unit :mm[inch]
Pin diameter tolerances :±0.10[±0.004]
General tolerances:±0.50[±0.020]
Notes:
1. For additional information on Product Packaging please refer to www.mornsun-power.com. Packaging bag number: 58210008;
2. It is recommended that the load imbalance of the dual output is ±5%. If it exceeds ±5%, the performance of the product cannot be
guaranteed to meet as datasheet marked. For details, please contact our technical staff;
3. The max. capacitive load should be tested within the input voltage range and under full load conditions;
4. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25, humidity<75%RH when inputting
nominal voltage and outputting rated load;
5. All index testing methods in this datasheet are based on our company corporate standards;
6. The performance indexes of the product models listed in this datasheet are as above, but some indexes of non-standard model
products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information;
7. We can provide product customization service;
8. Products are related to laws and regulations: see "Features" and "EMC";
9. Our products shall be classified according to ISO14001 and related environmental laws and regulations, and shall be handled by
qualified units.
Mornsun Guangzhou Science & Technology Co., Ltd.
Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Huangpu District, Guangzhou, P. R. China
Tel: 86-20-38601850 Fax: 86-20-38601272 E-mail:info@mornsun.cn www.mornsun-power.com