Subminiature Load Cell
Model 13
DESCRIPTION
Model 13 (compression only) subminiature load cell is designed
to measure load ranges from 150 g to 1000 lb. With subminiature
dimensions, including diameters from 0.38 in to 0.75 in and
heights of 0.13 in to 0.25 in, these units are easily incorporated
into systems having limited space. Model 13 combines high
frequency response and low deflection to achieve a combined
non-linearity and hysteresis of 0.25 % to 0.5 % full scale. A
balance module is included in the load cell’s lead wire cable for
temperature compensation and should not be removed.
FEATURES
• 150gto1000lb
• 0.7%accuracy
• mV/Voutput
• Subminiaturedesign
• Singlediaphragmconstruction
2Honeywell•SensingandControl
Model 13
PERFORMANCE SPECIFICATIONS
Characteristic Measure
Load ranges6150 g, 250 g, 500 g, 1000 g, 5 lb,
10 lb, 25 lb, 50 lb, 100 lb, 250 lb, 500 lb,
1000 lb
Linearity ±0.5 % full scale
Hysteresis ±0.5 % full scale
Non-repeatability ±0.1 % full scale
Tolerance on output
150 g to 500 g 15mV/V(nominal)
Tolerance on output 1000 g 1.5mV/V(nominal)
Tolerance on output
5 lb to 1000 lb 2mV/V(nominal)
Operation Compressiononly
Resolution Infinite
RANGE CODES
Range codes Range
AL 150 g
AN 250 g
AP 500 g
AR 1000 g
AT 5 lb
AV 10 lb
BL 25 lb
BN 50 lb
BR 100 lb
CN 250 lb
CR 500 lb
CV 1000 lb
ELECTRICAL SPECIFICATIONS
Characteristic Measure
Straingagetype
150 g to 500 g
Semiconductor
Straingagetype
1000 g to 1000 lb
Bonded foil
Excitation (calibration) 5Vdc
Insulation resistance 5000mOhm@50Vdc
Bridge resistance (toler-
ance)150 g to 500 g
500 ohm (nominal)
Bridge resistance (toler-
ance)1000 g to 1000 lb
350 ohm (nominal)
Zero balance (tolerance) ±3 % of full scale (nominal)
Shuntcalibrationdata Included
Electrical termination (std) 1,83 m [5 ft] integral cable with balance
board3
MECHANICAL SPECIFICATIONS
Characteristic Measure
Maximum allowable load Seetable
Weight Seetable
Material Stainlesssteel
Deflection @ full scale Seetable
WIRING CODES
Cable Unamplied
Red (+) excitation
Black (-) excitation
Green (-) output
White (+) output
DEFLECTIONS AND RINGING FREQUENCIES
Capac-
ity (lb)
Deec-
tion at
full scale
(10-3 in)
Weight Weight with
cable
Max. al-
lowable
load1 (%
FS)
150 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500
250 g 0.06 1 g [0.002 lb] 9 g [0.019 lb] 500
500 g 0.08 1 g [0.002 lb] 9 g [0.019 lb] 500
1000 g 0.05 1 g [0.002 lb] 9 g [0.019 lb] 150
5 lb 0.5 1 g [0.002 lb] 9 g [0.019 lb] 150
10 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150
25 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150
50 lb 0.4 1 g [0.002 lb] 9 g [0.019 lb] 150
100 lb 0.4 3 g [0.006 lb] 11 g [0.024 lb] 150
250 lb 0.5 3 g [0.006 lb] 11 g [0.024 lb] 150
500 lb 0.5 10 g [0.022 lb] 18 g [0.039 lb] 150
1000 lb 0.6 10 g [0.022 lb] 18 g [0.039 lb] 150
ENVIRONMENTAL SPECIFICATIONS
Characteristic Measure
Temperature, operating -54°Cto121°C[-65°Fto250°F]
Temperature, compensated 15°Cto71°C[60°Fto160°F]
Temperature effect, zero 0.01%fullscale/°F
Temperature effect, span 0.02%reading/°F
Honeywell•SensingandControl3
Subminiature Load Cell
MOUNTING DIMENSIONS
Ranges D1 D2 H B SR
150, 250, 500,
1000 g; 5, 10, 25, 50 lb
2,29 mm [0.09 in] 9,65 mm [0.38 in] 3,3 mm [0.13 in] 0,69 mm [0.027 in] 6,35 mm [0.25 in]
100, 250 lb 3,05 mm [0.12] 12,7 mm [0.50 in] 3,81 mm [0.15 in] 0,51 mm [0.020 in] 12,7 mm [0.50 in]
500 lb, 1000 lb 6,35 mm [0.25 in] 19,05 mm [0.75] 6,35 mm [0.25 in] 0,64 mm [0.025 in] 12,7 mm [0.50 in]
OPTION CODES
Many range/option combinations are available in
our quick-ship and fast-track manufacture pro-
grams. Please see http://sensing.honeywell.com/
TMsensor-ship for updated listings.
Load range 150, 250, 500 g,
1000 g; 5, 10, 25, 50, 100, 250, 500, 1000 lb
Temperature
compensa-
tion
1a.60°Fto160°F
1b.30°Fto130°F
1c.0°Fto185°F
1d.-20°Fto200°F
1e.-20°Fto200°F
1j.0°Cto50°C
1k.-20°Cto85°C
1m.-25°to110°C
Internal
ampliers
2u.Unamplied,mV/Voutput
Overload
stops
4a. Overload stops
Electrical
termination
5 ft integral cable with balance board3
6v. Phoenix connector on end of cable
15d.Connectoronendofcable
Special
calibration
9a.10point(5up/5down)20%increments@68°F
9b.20point(10up/10down)10%increments@68
°F
Shock and
vibration
44a.Shockandvibrationresistance
TYPICAL SYSTEM DIAGRAM
008641-2-EN IL50 GLO
April 2009
Copyright © 2009 Honeywell International Inc. All rights reserved.
Model 13 Subminiature Load Cell
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
NOTES
1. Allowable maximum loads – maximum load to be applied without
damage.2 Loads described allow for 100 % full scale axial loading
with the bending loads specified. Torque loading maximum is with-
outaxialorotherload.Foranyothercombination,consultfactory.
2. Without damage - loading to this level will not cause excessive zero
shift or performance degradation. The user must consider fatigue
life for long term use and structural integrity. All structurally critical
applications (overhead loading, etc.) should always be designed
with safety redundant load paths.
3. A small, 2 in circuit board is included in the cable, 2 ft from the load
cell. Do not remove this board.
4. Only for ranges greater-than-or-equal-to 1000 g.
5. Specicationsmayvarywiththisoption.
6. This unit calibrated to Imperial (non-Metric) units.
Warranty. Honeywell warrants goods of its manufacture as
being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed
to otherwise by Honeywell in writing; please refer to your
order acknowledgement or consult your local sales office for
specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair
or replace, at its option, without charge those items it finds
defective. The foregoing is buyer’s sole remedy and is in lieu
of all warranties, expressed or implied, including those of
merchantability and tness for a particular purpose. In no
event shall Honeywell be liable for consequential, special, or
indirect damages.
While we provide application assistance personally, through our
literature and the Honeywell web site, it is up to the customer to
determine the suitability of the product in the application.
WARNING
PERSONAL INJURY
•DONOTUSEtheseproductsassafetyoremergency
stop devices or in any other application where failure of
the product could result in personal injury.
Failure to comply with these instructions could result in
death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
•Theinformationpresentedinthisdatasheetisfor
referenceonly.DONOTUSEthisdocumentasproduct
installation information.
•Completeinstallation,operationandmaintenance
information is provided in the instructions supplied with
each product.
Failure to comply with these instructions could result in
death or serious injury.
Find out more
Honeywell serves its customers
through a worldwide network of
sales offices, representatives
anddistributors.Forapplication
assistance, current specifica-
tions, pricing or name of the
nearest Authorized Distributor,
contact your local sales office.
To learn more about Honeywell’s
test and measurement products,
call +1-614-850-5000, visit
www.honeywell.com/sensotec,
or e-mail inquiries to
info.tm@honeywell.com
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Honeywell:
060-2444-03 060-2443-08 060-2445-04 060-2443-02 060-2443-07 060-2444-06 060-2443-06