Ti400, Ti300 and Ti200 Advanced Performance Infrared Cameras Technical Data Now compatible with Fluke Connect TM Mobile App This trio of new Fluke infrared cameras is equipped with LaserSharp(R) Auto Focus. Yes, there are other auto focus systems on the market but Fluke took it one step further so you get consistently in-focus images, Every. Single. Time. Every infrared camera user knows that focus is the single most important aspect to ensure when conducting an infrared inspection. Without an in-focus image temperature measurements may not be accurate and it's much easier to miss a problem. LaserSharp(R) Auto Focus tells you exactly where you are focusing. It uses a laser to calculate the distance to your target before it focuses. Place the red laser dot on the object you are inspecting, then pull and release the trigger for a perfect in-focus image. * Only Fluke ConnectTM gives you instant access to critical data--unlike any other camera on the market to keep your facility up and running - Send measurements directly from the inspection site to your boss or client and get answers and approvals instantly * Detect and communicate issues faster with patented Fluke IR-Fusion technology with AutoBlend mode * Faster communication with wireless image transfer directly to your PC, Apple iPhone or iPad * One-handed, easy-to-use user interface * Ruggedized high resolution 640x480 capacitive touch screen for quick menu navigation * Capture additional digital images to show location or additional site details with IR-PhotoNotes Annotation System * Standard and radiometric video recording* * Streaming video (USB and HDMI) * Text* and voice recording and annotation gets additional details saved with the image file * Optional interchangeable lenses for greater flexibility in additional applications * High-temperature measurement (up to 1200 C on the Ti400) * Included SmartView and SmartView Mobile App Analysis and Reporting Software Ti400 Ti300 Ti200 Built with TM (R) (R) (R) (R) TM See it. Save it. Share it. All the facts, right in the field. Fluke Connect with ShareLiveTM video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is available for AndroidTM and iOS and works with over 20 different Fluke products--the largest suite of connected test tools in the world. And more is on the way. Go to the Fluke website to find out more. Make the best decisions faster than ever before by viewing all temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity. Download the app at: (R) * Firmware updates for these features are not available yet in all countries. Users notified via SmartView software when available. Smart phone not included with purchase. Detailed specifications Ti400 Temperature Temperature measurement range (not calibrated below -10 C) Temperature measurement accuracy On-screen emissivity correction On-screen reflected background temperature compensation On-screen transmission correction Imaging performance Image capture frequency Detector type Thermal sensitivity (NETD) Ti300 -20 C to +1200 C (-4 F to +2192 F) -20 C to +650 C (-4 F to +1202 F) 2 C or 2 % (at 25 C nominal, whichever is greater) Yes (by number and table) Yes Yes 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation Focal Plane Array, uncooled Focal Plane Array, uncooled Focal Plane Array, uncooled microbolometer, 320 x 240 pixels microbolometer, 240 X 180 pixels microbolometer, 200 X 150 pixels 0.05 C at 30 C target temp (50 mK) 0.075 C at 30 C target temp (75 mK) Total pixels 76,800 Infrared spectral band Visual (visible light) camera Standard infrared lens type Field of view Spatial resolution (IFOV) 1.31 mRad Minimum focus distance Optional telephoto infrared lens type, available soon Field of view Spatial resolution (IFOV) 0.65 mRad Minimum focus distance Optional wide-angle infrared lens type, available soon Field of view Spatial resolution (IFOV) 2.62 mRad Minimum focus distance Focus mechanism 43,200 7.5 m to 14 m (long wave) Industrial performance 5.0 megapixel 30,000 24 x 17 1.75 mRad 15 cm (approx. 6 in) 2.09 mRad 12 x 9 0.87 mRad 45 cm (approx. 18 in) 1.05 mRad 46 x 34 3.49 mRad 15 cm (approx. 6 in) 4.19 mRad Yes LaserSharp(R) Auto Focus System Advanced Manual Focus Image presentation Palettes Standard Ultra ContrastTM Yes Level and span Fast auto toggle between manual and auto modes Fast auto-rescale in manual mode Minimum span (in manual mode) Minimum span (in auto mode) IR-Fusion(R) information Picture-In-Picture (PIP) Full screen infrared AutoBlendTM mode Color alarms (temperature alarms) Image capture and data storage Image capture, review, save mechanism Storage medium File formats Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Smooth auto-scaling and manual scaling of level and span Yes Yes 2.0 C (3.6 F) 3.0 C (5.4 F) Yes Yes Yes High-temperature , low-temperature, and isotherm (user-selectable) One-handed image capture, review, and save capability Micro SD Memory Card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Video*: non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3) No analysis software required for non-radiometric (.bmp, .jpg and .avi*) files Export file formats w/SmartView software Memory review Other time-saving and productivity features Voice annotation IR-PhotoNotesTM Wi-Fi connectivity Text annotation* Video recording* Streaming Video CNXTM Wireless System* Fluke Connect compatible Auto capture (temperature and interval)* Remote control and operation (for special and advanced applications) (R) BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF Thumbnail view navigation and review selection 60 seconds maximum recording time per image; reviewable playback on imager Yes Yes, to PC, iPhone , iPad and WiFi to LAN* Yes (R) Yes (R) Standard and Radiometric Via USB to PC and HDMI to HDMI compatible screen Yes* Yes Yes* No * Firmware updates for these features are not available yet in all countries.. Users notified via SmartView software when available. 2 Fluke Corporation Ti200 Ti400, Ti300, and Ti200 Industrial Thermal Imagers No General specifications Operating temperature Storage temperature Relative humidity Ruggedized Touchscreen Display (Capacitive) Controls and adjustments -10 C to +50 C (14 F to 122 F) -20 C to +50 C (-4 F to 122 F) without batteries 10 % to 95 % non-condensing 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight AC operation Power saving Safety standards Electromagnetic compatibility User selectable temperature scale (C/F) Language selection Time/Date set Emissivity selection Reflected background temperature compensation Transmission correction User selectable hot spot and cold spot, and center point on the image Expandable-contractable Measurement Box with MIN-AVG-MAX temp Color alarms User selectable backlight setting Graphical information display preference SmartView and SmartView Mobile App - full analysis and reporting software Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level, all models Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage) 2.5 hours to full charge Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter. All models AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. User selectable sleep and power off modes UL 61010-1:2012 CAN/CSA-C22.2 No.61010-1-12 IEC 61010-1 3rd Edition (2010) EN 61326-1:2006 IEC 61326-1:2005 C Tick US FCC Vibration IEC/EN 61326-1 CFR 47, Part 15 Subpart B Class B 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 Shock Drop Size (H x W x L) Weight (battery included) Enclosure rating Warranty Recommended calibration cycle Supported Languages 25 g, IEC 68-2-29 Engineered to withstand 2 meter (6.5 feet) with standard lens 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) 1.04 Kg (2.3 lb) IP54 (protected against dust, limited ingress; protection against water spray from all directions) Two-years (standard), extended warranties are available. Two-years (assumes normal operation and normal aging) Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish Software Batteries Battery life Battery charge time AC battery charging (R) Get the SmartView Mobile app (R) Bring your office to your inspection site with the SmartView Mobile App. Create an inspection report on site and communicate directly to your client or manager via your Apple iPhone or iPad . (R) (R) (R) Optimize: Adjust the image to present problems in the most effective way. Analyze: Use markers and other tools to quantify the severity of problems. Communicate: Share inspection results by emailing images or reports. Fluke SmartView Mobile will increase the return on your infrared camera investment. It's not just about working faster--it's about working smarter. Ordering information FLK-Ti400 FLK-Ti400 FLK-Ti300 FLK-Ti300 FLK-Ti200 FLK-Ti200 9 Hz Thermal Imager, 9 Hz 60 Hz Thermal Imager, 60 Hz 9 Hz Thermal Imager, 9 Hz 60 Hz Thermal Imager, 60 Hz 9 Hz Thermal Imager, 9 Hz 60 Hz Thermal Imager, 60 Hz Included Thermal imager with standard infrared lens; ac power supply and battery pack charger (including mains adapters); two, rugged lithium ion smart battery packs; USB cable; HDMI video cable; SmartView software available via free download; rugged, hard carrying case; soft transport bag; adjustable hand strap; warranty registration card. (R) Optional accessories FLK-LENS/TELE2 Telephoto infrared lens (2X magnification) FLK-LENS/WIDE2 Wide-angle infrared lens TI-CAR-CHARGER Thermal imager vehicle charger FLK-TI-VISOR3 Thermal imager visor BOOK-ITP Introduction to Thermography Principles book TI-TRIPOD3 Tripod mounting base accessory FLK-Ti-SBP3 Additional smart battery FLK-TI-SBC3 Additional Smart Battery Charger Kits FLK-TI400 FLK-TI300 FLK-TI200 FLK-TI400 FLK-TI400 FLK-TI300 FLK-TI200 FLK-TI400 60HZ/FCA* Thermal Imager, 3000 FC DMM, a3001FC iFlex Module 60HZ/FCA* Thermal Imager, 3000 FC DMM, a3001FC iFlex Module 60HZ/FCA* Thermal Imager, 3000 FC DMM, a3001FC iFlex Module 60HZ/FCC* Thermal Imager, 3-a3001FC iFlex Modules, 805 Vibration Tester, WiFi SD Card 9HZ/FCA Thermal Imager, 3000 FC DMM, a3001FC iFlex Module 9HZ/FCA Thermal Imager, 3000 FC DMM, a3001FC iFlex Module 9HZ/FCA Thermal Imager, 3000 FC DMM, a3001FC iFlex Module 9HZ/FCC Thermal Imager, 3-a3001FC iFlex Modules, 805 Vibration Tester, WiFi SD Card Visit the Fluke website to get complete details on these products or kits or ask your local Fluke sales representative. *Only available in certain countries. Fluke Corporation PO Box 9090, Everett, WA 98206 U.S.A. Fluke Europe B.V. PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com (c)2013-2014 Fluke Corporation. All trademarks are the property of their respective owners. Specifications subject to change without notice. Printed in U.S.A. 2/2014 4347232F_EN Modification of this document is not permitted without written permission from Fluke Corporation. 4 Fluke Corporation Ti400, Ti300, and Ti200 Industrial Thermal Imagers Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Fluke: FLK-TI400 60HZ/FCA FLK-TI400 60HZ/FCC FLK-TI200 60HZ/FCA FLK-TI300 60HZ/FCA