C
M
E3
.
3
V6
A
/
5
V
8
A
5
3.3
Output voltage
( V )
- 48
Input voltage
( V )
- 36
~ -
60
Input voltage range
( V )
- 53
Conduction noise
(dBm)
+ 5%
- 5%
+ 5%
- 5%
Output voltage range
8
6
Output Current
( A )
0
~
8
0
~
6
Output current range
( A )
12
9
Over current pr
otection
( A )
6
4.2
Over voltage protection
( V )
100
Output ripple noise
( mVp-p )
87.5 %
Efficiency
Ta
=
0
~70
°
C
Operating temparature
69.5
×
65.6
×
8.5
Mechanical dimension
( mm )
AC
500, DC
707 (applied for 1minute)
Isolated voltage
( V )
Parallel operation
Forced air cooling (1.5m
/sec)
Cooling method
4.5
2.5
Low voltage protection
( V )
C
M
E3
.
3
V6
A
/
5
V
8
A
Function
Symbol
Pin No.
Not connected*
T T2
1
Not connected*
T T1
2
Local off contr
ol signal pin
LO
3
Remote off contr
ol signal pin
RO
4
Alarm pin
P
5
Input voltage pin
-IN
6
Input ground pin
+IN
7
Not connected*
NC
8
Output voltage pin
+
3.3 V
9
10
Output ground pin
-
11
12
-
5 V
13
14
Output voltage pin
+
15
16
17
*NC may be used for testing by the manufacturer and shall not be connected by the customer
.
Outline diagram
Pin arrangement
17
9
2.5MIN
8.5MAX
φ
1.0
8
1
59.69
±
0.5
69.0
±
0.5
65.1
±
0.5
4
×
5.08=20.32
3
×
5.08=15.24
8
×
5.08=
40.64
* Dimentions are in millimeters.
Suppliers Inquiry
Previous
Next
Link
Name *
Reason for Contact
General Inquiry
Place Order
Report Issue
Target Price (Option)
Email Address *
Message *
BOM / Attach Files (Option)