MS1402
Advanced Power Technology reserves the right to change, without notice, the specifications and information contained herein
Visit our website at WWW.ADVANCEDPOWER.COM or contact our factory direct.
ELECTRICAL SPECIFICATIONS (Tcase = 25ELECTRICAL SPECIFICATIONS (Tcase = 25°°C)C)
STATIC Value
Symbol Test Conditions Min. Typ. Max. Units
BVCES IC = 5 mA VBE = 0 V 36 V
BVCEO IC = 25 mA IB = 0 mA 16 V
BVEBO IE = 1 mA IC = 0 mA 4.0 V
ICBO VCB =15 V IE = 0 mA 1.0 mA
hFE VCE = 5 V IC = 100 mA 20 100
DYNAMIC Value
Symbol Test Conditions Min. Typ. Max. Units
POUT f = 470 MHz PIN = 0.20 W VCC = 12.5 V 2.0 W
GP f = 470 MHz PIN = 0.20 W VCC = 12.5 V 10 dB
COB f = 1 MHz VCB = 12 V 10 pF
IMPEDANCE DATAIMPEDANCE DATA
Freq. ZIN (ΩΩ) ZCL (ΩΩ)
450 MHz 2.7 – j 0.9 11.5 + j 15.0
470 MHz 2.6 – j 1.3 12.2 + j 13.5
512 MHz 2.2 – j 1.7 12.7 + j 13.0