30 ALPHA-NUMERIC LISTINGS OF ALL DIODES AND SCRs. - FUNCTION CODE HEADING TO USE Signal: Rectify:| SIG: REC: _| es Ca @ Switch: wave. Sw: Mic. {| Vr If | Ive | Is | Ve |Itmin S 2 | Min Max.| ber Ir Tunnel, Vari-c & | TUN 2 itive di a| Ve | Ie |} Ct | AC] Ve | fe |ae| Ip {I Vp | W Wsensitte codes. vc < + S58 7 Py DRG. MANUFACTURERS egulators an z x emp. ws z No. (See Sect. 2 for full Reference diodes. zt Ve | Imax| Ive Co-ef. VF | Ptot : = [nom] tol Iz | Rz Refer t names and addresses) t xo efer to SCRs. SCR ; dy, < |Gate(orVsw) 3-4 Layer diodes. ] 34p| 2]W-ort| If | ton | Loffy VF Var] Sx A | y_| Lh {off |Sect. 8 TYPE NUMBER| 2 {3 ] 4 5 6 7 8 9 10 | 11 | 12 | 13 | 14 15 16 C122M1 ScR 600 8 1.8 200 100 {25m 1.5 30m 500n [XS b3 C122M2 SCR 600 8 1.8 200 100 |25m 1.5 30m 500u [X19 b3 |GES C122M3 SCR 600 8 1.8 200 100 |25m 1.5 30m 5004 ]X32 b3 | GES C122M4 SCR 600 8 1.8 100 [25m 1.5 30m 500% |X23 b3 |GES C122M5 SCR 600 8 1.8 200 100 [25m 1.5 30m 500u |X37 63 | GES C122M6 SCR 600 8 1.8 200 100 [25m 1.5 30m 500n/xX12 b3 |GES C123A SCR 100 8.0 1.4. 200 100 |25m 1.5 30m 5004 |X5 63 GES C1i23A1 SCR 100 8.0 1.4 200 100 [25m 1.5 30m 500u]Xx5 b3 GES C123A2 SCR 100 8.0 1.4 200 100 ]25m 1.5 30m 50y |X19 b3 | GES C123A3 SCR 100 8.0 1.4 200 100 [25m 1.5 30m 500u [x32 53 |GES C123A4 SCR 100 8.0 1.4 200 100 |25m 1.5 30m 500y |x23 63 |GES C123A5 SCR 100 8.0 1.4. 200 100 |25m 1.5 30m 500y |X37 63 | GES C123A6 SCR 100 8.0 1.4 200 100-}25m 1.5 30m 500y {X12 63 |GES 123B SCR 200 8.0 1.4 200 100 [25m 1.5 30m 500K |x5 63 GES 123B1 SCR 200 8.0 1.4 200 100 [25m 1.5 30m 500u]X5 b3 GES 12382 SCR 200 8.0 1.4 200 100 {25m 1.5 30m 500u4 1x19 b3 |GES C12383 SCR 00 8.0 1.4 200 100 |25m 1.5 30m 500y 1x32 b3 |GES 012384 SCR 200 8.0 1.4 200 100 | 25m 1.5 30m 500u | X23 b3 GES C123B5 SCR 200 8.0 1.4 200 100 | 25m 1.5 30m 500u |X37 63 GES C123B6 SCR 200 8.0 1.4 20 100 [25m 1.6 30m 500u |X12 63 |GES c123 SCR 300 8 1.4 200 100 [25m 1.5 30m 5004 ]X5 b3 GES 123C1 SCR 300 8 1.4 200 100 [25m 1.5 30m 500u |X5 63 GES 123C2 SCR 300 5 2 120 | 40m 2 60m 4.m |S60 b6 {GES 1233 SCR 300 8 1.4 200 100 | 25m 1.5 30m = =500n [X32 b3 GES 12304 SCR 300 8 1.4 200 100 {| 25m 1.5 30m 500u |X23 b3 GES C123G5 SCR 300 8 1.4 200 100 | 25m 1.5 30m = =5004 [X37 b3 GES C1236 SCR 300 8 1.4 200 100 | 25m 1.5 30m 500pn [X12 b3 GES C1230 SCR 400 8 1.4 200 100 |25m 1.5 30m 500u|X5 b3 GES 12301 SCR 400 8 1.4 200 100 }25m 1.5 30m 500n 1X5 53 GES 123D2 SCR 400 8 1.4 200 100 {25m 1.5 30m 500y ]X19 b3 |GES C12303 SCR 400 8 1.4 200 100 | 25m 1.5 30m 500% [X32 b3 GES C12304 Scr 400 8 1.4 200 100 | 25m 1.5 30m 500u [X23 b3 GES C12305 SCR 400 8 1.4 200 100 | 25m 1.5 30m 500n [X37 b3 GES 12306 SCR 400 8 1.4 200 100 |25m 1.5 30m 500u /X23 b3 |GES C123 SCR 500 8.0 1.4 200 100 |25m 1 30m 500K |X5 b3 GES C123E1 SCR 500 8.0 1.4 200 100 | 25m 1 30m 500m |/X5 b3 GES C123E2 SCR 500 8.0 1.4 200 100 |25m 1 30m 500m |X19 b3 | GES C1233 SCR 500 8.0 1.4 200 100 [25m 1 30m 504% 4X32 63 GES C123E4 SCR 500 8.0 1.4 200 100 [25m 1 30m 500m [X23 b3 | GES C123E4 SCR 500 8.0 1.4 200 100 | 25m 1 30m 500m [23 b3 GES C1236 SCR 500 8.0 1.4 200 100 [25m 1.5 30m 500p |12 b3 GES C123F SCR 50 7 1.5 200 120 |25m 1.5 30m .5m [x5 b3 GES C123F1 SCR 50 2 1.54} 30, 1.1 25 130 |10m 3 5m Im {TS b4 GES C123F2 SCR 50 7 1.5 200 100 |25m 1.1 35m .5m |X19 b3 |GES C123F3 SCR 50 7 1.5 200 120 | 25m 1.5 35m 5m |X32 b3 GES C123F4 SCR 50 8 1.5 200 120 | 25m 1.5 25m 5m |X23 b3 GES C12365 scR 50 8 1.5 200 120 |25m 1.5 30m 5m 1X37 63 GES C123F6 SCR 50 8 1.5 200 120 |25m 1.5 30m .5m 4X12 03 |GES C123M SCR 600 8 1.4 200 100 |25m 1.6 30m 600n /x5 b3 GES C123M1 SCR 600 8 1.4 200 100 | 25m 1.5 30m 500n |X5 b3 GES C123M2 SCR 600 8 1.4 200 100 | 25m 1.5 30m = =500u 1X19 b3 GES C123M3 SCR 600 8 1.4 206 100 |25m, 1.5 30m 5004 [X32 b3 GES C123M4 scr 600 8 1.4 200 100 | 25m 1.5 30m = 5004 |X23 53 GES C123M5 scr 600 8 1.4 200 100 | 25m 1.5 30m 5004 |X37 b3 GES C123M6 SCR GA |0 5m 1.5 30m = =500u 11 b3 GES C135A scR 100-35 30, 2.3 200 120 j80m 2.5 100m 3m {7148 b6 |NAE C1358 SCR 200 35 25u 2 200 120 2 100m 3m |T48 be {NAE C135C SCR 300 35 304% 2.3 200 120 |80m 2.5 100m 3.m |T48 66 NAE C1350 SCR 400 35 30n 2.3 200 120 [80m 2.5 100m 3m T48 b6 NAE C135E SCR 500 35 30p 82.3 200 120 |80m 2 100m 3.0m }T48 b6 NAE C135M SCR 600 35 30h 2.3 200 120 |80m 2 100m 3 T48 b6 NAE C135N SCR 800 35 5.04] 304 2.3 200 120 |80m 2 100m 3.0m /T48 b6 NAE C1358 scr 700 35 30n 2.3 200 120 |80m 2 100m 3 T48 b6 NAE C137E SCR 500 35 30u 2.3 100 120 |80m 2 100m 3.0m |/T4B b6 GES NAE C137M SCR 60 35 30n 82.3 100 120 {80m 2 100m 3.0m |T48 b6 GES NAE C137N SCR 80 35 30. 2.3 100 120 |80m 2 100m 3.0m ]T48 b6 GES NAE C137P SCR 1K 35 30h 2.3 100 120 |80m 2. 100m 2m T48 b6 GES NAE C137PA 11K 35 30n 2.3 100 80m 2.5 100m 20m /{T48 b6 NAE C137PB SCR 1.2K 35 30, 2.3 100 Bom 2. 100m 2.0m |T48 b6 |GES NAE C1375 SCR 700 35 30np 2.3 100 120 [80m 2 100m 3.0m |T48 b6 NAE C137T SCR 900 35 304 2.3 100 120 |80m 2.5 100m 3m T48 b6 NAE C138E10E SCR 50 20 10u 4.0 200 120 18m 3 150m 4.0m [T48 b6 GES C138E20E scr 50 20 20n 4.0 2 120 |180m 3 150m 4.0m |T48 b6 GES C138M10M SCR 600 20 10, 4 200 120 [180m 3 150m 4." |[T48 b6 GES C138M20M SCR 600 20 20n 4 200 120 {180m 3 150m 4.m {1748 66 GES C138N10M sca 800 20 10, 4.0 200 120 [180m 3 165i we [TAA bE GES C138N20M SCR 800 20 20yu 200 80m 3 150m 4.0 |T48 v6 GES C138S10M SCR 700 20 10u 4.0 200 120 180m 3 150m 4.0m [T48 b6 GES C138S20M SCR 700 20 20n 4.0 200 120 180m 3 150m 4.0m |T48 b6 GES C139E10E SCR 500 20 10n 4.0 200 120 180m 3 150m 4.0m |T48 b6 GES . age Copyright Semi Ind Limited. Section 1 for abbreviations and symbols. Copyright Semicon Indexes Limite Section 2 for manufacturers addresses. Section 8 for terminations and leads