TUBE FITTINGS M U LT I -C O N N E C T O R 4-55 M U LT I -C O N N E C T O R S E R I E S DM* The use of a multi-connector enables connection of the panel with o t h e r a p p a r a t u s a n d c a n p ro v i d e t h e re l i a b i l i t y o f o n e - t o u c h i n s t a l l a t i o n a n d re m o v a l o f m u l t i - t u b e s ( n y l o n , p o l y u re t h a n e ) . A s a re s u l t , s e p a r a t e t r a n s p o r t a t i o n o f p a n e l a n d m a c h i n e r y e q u i p m e n t a n d b a c k u p u n i t e x c h a n g e a re m a d e p o s s i b l e . O n e - t o u c h i n s t a l l a t i o n a n d re m o v a l E m p l o y s t h e u n i q u e b u i l t - i n k e y i n g m e c h a n i s m w h i c h p ro v i d e s o n e - t o u c h i n s t a l l a t i o n a n d re m o v a l c a p a b i l i t y e v e n i n h a rd t o s e e l o c a t i o n s . I n a d d i t i o n i t p re v e n t s i n s t a l l a t i o n m i s t a k e s w h e n re - c o n n e c t i n g . I n s t a l l a t i o n p ro c e s s e s a re re d u c e d c o n s i d e r a b l y A s c o m p a re d w i t h t h e u s e o f m a n y b u l k h e a d u n i o n s , t h i s i n s t a l l a t i o n i s v e r y e a s y a n d i n s t a l l a t i o n t i m e i s re d u c e d c o n s i d e r a b l y. Fittings & Tubing R e l i a b l e t u b e re t a i n i n g f o rc e This construction mechanism enables clamping and unclamping e v e r y t u b e i n u s e b y o n e o p e r a t i o n a n d c a n p ro v i d e a re l i a b l e t u b e re t a i n i n g f o rc e . Number of connecting tubes 2 types-6 tubes & 12 tubes. DIMENSIONS D M 6 M U LT I C O N N E C T O R (* Patent pending) TECHNICAL SPECIFICATIONS Air Fluid Max operating pressure 10 Bar Ambient and fluid temperature Applicable tube* 0~60C Soft nylon, Polyurethane *SMC types TS, TU or others to dimensions BS5409 part 1 HOW TO O R D E R M U LT I C O N N E C T O R DIMENSIONS D M 1 2 M U LT I C O N N E C T O R DM NUMBER OF TUBES 6 ......6 12 ...12 MODEL Nil ...Multi-Connector P ......Plug side only S ......Socket side only NU COVER C1 ...Cover one side C2 ...Cover both sides Nil ...No cover TUBE O.D. 04 ...4mm 06 ...6mm STOCKED PRODUCTS F OR A LIST OF S TOCKED P RODUCTS , PLEASE SEE THE CURRENT SMC PRICE LIST Dimensions in mm Model Barb ID(d) DM6-04NU DM12-04NU 1.6 DM6-06NU DM12-06NU 3 A B 6 31 HOW TO USE SEE NEXT PAGE V O OR RD DE ER R LL II N NE E SS SEE INSIDE FRONT COVER FOR D E T A I L S O F Y OFax: U R L O01-502710 CAL SALES OFFICE 01-501822 Castle Hill NSW.............Tel: (02) 680 3222.....Fax: (02) 894 5719 Tel: FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOGUE REFERENCE E501 4-56 TUBE FITTINGS M U LT I -C O N N E C T O R H O W T O U S E T H E M U LT I -C O N N E C T O R PRECAUTIONS B e s u re t o i n s e r t t h e t u b e s l o w l y s o t h a t y o u f e e l i t move smoothly and can feel it touch the end. 1 REMOVING Loosen clamp ring , and separate the multi-connector into two parts, socket side and plug side Fittings & Tubing 2 INSERTION AND REMOVAL OF TUBE 1 Tu r n t h e c l a m p b o l t t o t h e l e f t w i t h a s c re w - d r i v e r, l o o s e n u n t i l t h e stopper touches the case , and barb cassette will be pulled out in the d i re c t i o n A , t h e n c l a m p p o r t i o n B , c o n s i s t i n g o f b a r b a n d c a s e , w i l l b e f re e d . T h e n i n s e r t o r re m o v e t h e t u b e . 2 The same number curved on every port indicates that socket and plug side can be connected. 3 I f i t i s h a rd t o i n s e r t t h e t u b e , e n l a r g e t h e m u l t i - c o n n e c t o r w i t h t h e h e a d o f s t o p p e r, e x p a n d e r C , b e f o r e i n s e r t i n g t u b e , t o s u c h a n e x t e n t t h a t i t accommodates the number of tubes you intend to use. 4 I n s e r t t u b e u n t i l i t c l e a r s t h e m o u n t a i n o f b a r b c o m p l e t e l y. 3 CLAMPING OF TUBE 1 A f t e r i n s e r t i n g t u b e , t i g h t e n c l a m p b o l t w i t h a s c re w d r i v e r. 2 B a r b c a s s e t t e c re e p s i n t o t h e d i re c t i o n D a n d t h e t u b e w i l l b e c l a m p e d a t the clamp portion B consisting of barb and case 4 CONNECTING 1 P u s h t o g e t h e r a n d ro t a t e b o t h o f t h e c a s e s , a n d t h e p l u g s i d e w i l l s l i d e i n t o t h e s o c k e t s i d e a t t h e p ro p e r p o s i t i o n . 2 The ring E, male and female, of the plug side and socket side will interlock each other at the proper position by pushing together and ro t a t i n g . 3 F i n a l p ro c e s s o f c o n n e c t i o n i s t o s c re w i n t h e c l a m p r i n g . 5 COVER MOUNTING 1 Cover is mountable on both sides, plug side and socket side. 2 E n l a r g e c o v e r a n d m o u n t c o v e r o n t o m o u n t i n g a re a . FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOGUE REFERENCE E501 In case the number of tubes to be used is 6 (DM6) and 12 (DM12) or less, the positioning of the tube s h o u l d b e s y m m e t r i c a l t o t h e c e n t re . 0nce the tube has been properly inserted, pull it b a c k g e n t l y, a n d i f i t d o e s n o t c o m e o u t , i t i s t h e sign of complete insertion. TUBE FITTINGS R E C TA N G U L A R M U LT I -C O N N E C T O R 4-57 R E C TA N G U L A R M U LT I -C O N N E C T O R S E R I E S KDM Substantial reduction in mounting space In comparison with a model requiring many union joints for panels and partitions, this model needs only a small space O n e - t o u c h c o n n e c t i o n / d i s c o n n e c t i o n w i t h o u t c o n n e c t i o n e r ro r s S u i t a b l e f o r u s e w i t h p o s i t i v e p re s s u re a n d v a c u u m P o s s i b l e t o c re a t e m u l t i - c o n n e c t o r w i t h m i x e d t u b e s i z e s H O W T O USE SEE NEXT PAGE TECHNICAL SPECIFICATIONS Fluid Fittings & Tubing DIMENSIONS KDM10 Air Max. operating pressure 10 Bar (1.0 mPa) Operating vacuum pressure 10torr~ Proof pressure 15 Bar (1.5 MPa) Ambient and fluid temperature Applicable tube 0 ~ 60C Nylon, Soft Nylon, Polyurethane MIXED SIZES OF PLUG CONNECTORS AND SOCKET CONNECTORS T h e re c t a n g u l a r m u l t i - c o n n e c t o r p e r m i t s c o n n e c t o r e x c h a n g e i n a n y d e s i r e d p o s i t i o n , t h u s a l l o w i n g u s e o f d i f f e re n t s i z e s o f t u b e s . HOW TO O R D E R KDM PARTS DIMENSIONS KDM20 Connector Plug Connector Socket connector (with packing) T O C R E AT E M I X E D T U B E S I Z E U N I T S Tube O.D. Model O4 KDMP-04 O6 KDMP-06 O3.2 KDMS-23 O4 KDMs-04 O6 KDMS-06 1 L o o s e n t h e c r o s s - re c e s s e d h e a d m a c h i n e s c r e w u s i n g a P h i l l i p s t y p e s c r e w d r i v e r t o re m o v e t h e p l a t e f r o m t h e c a s e . 2 After exchanging connectors in desired places, fix the plate with a Phillips type screwdriver to the case. HOW TO O R D E R K D M M U LT I - C O N N E C T O R Number of Tube O. D. (mm) connecting tubes 10 20 STOCKED PRODUCTS Model O4 KDM10-04 O6 KDM10-06 O4 KDM20-04 O6 KDM20-06 V F OR A LIST OF S TOCKED P RODUCTS , PLEASE SEE THE CURRENT SMC PRICE LIST O OR RD DE ER R LL II N NE E SS SEE INSIDE FRONT COVER FOR D E T A I L S O F Y OFax: U R L O01-502710 CAL SALES OFFICE 01-501822 Castle Hill NSW.............Tel: (02) 680 3222.....Fax: (02) 894 5719 Tel: FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOGUE REFERENCE E501 4-58 TUBE FITTINGS R E C TA N G U L A R M U LT I -C O N N E C T O R HOW TO USE Separation Loosen the clamp bolt to separate the plug side from the socket side. Fittings & Tubing Connection P u t t o g e t h e r t h e i r re g u l a r f a c e s f o r e n g a g e m e n t a n d c o n n e c t t h e p l u g c a s e t o the socket. After tightening the clamp bolt by hand, tighten it fur ther with hexagon bar wrench (nominal width across flats:4). Panel Mounting 1 Loosen (4) screws for bracket on the socket side using a Phillips type s c re w d r i v e r ( J I S n o m i n a l N o 2 ) u n t i l t h e b r a c k e t t o u c h e s t h e s t o p r i n g . 2 Shift the panel mounting bracket to the inside (move the screw for bracket in the longitudinal direction of the slot) and put the connector in the panel mounting hole. (Panel mounting hole: See dimensions). 3 After shifting the bolt for bracket to the outside, tighten the bolt with a Phillips type screwdriver to fix the socket case. 4 Loosen the screw for bracket until the bracket touches the stop ring and shift the bracket to the inside to remove the connector from the panel. FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT REQUEST CATALOGUE REFERENCE E501