4/16/2010 120W Constant Current LED Driver LEDWC120 series FEATURES 3/4Ultra High Efficiency (Up to 91%) 3/4Active Power Factor Correction (Up to 0.99) 3/4Waterproof (IP67) 3/4Dimming Function 3/4Lightning Protection 3/4Over Voltage, Over Temp. & Short Circuit Protection 3/4Comply with UL8750 & EN61347 Safety Regulations 3/4Very High MTBF & Life Time SPECIFICATION Model Rated Current (1) Current Range (Min - Max) mA Output Rated Power LEDWC( )120S035ST LEDWC( )120S045ST LEDWC( )120S070ST LEDWC( )120S105ST LEDWC( )120S140ST LEDWC( )120S175ST 350mA 450mA 700mA 1050mA 1400mA 1750 mA 2100 mA 332 - 368 427 - 473 665 - 735 997 - 1102 1330 - 1470 1662 -1837 1995 - 2205 120W 120W 120W 120W 120W 120W 120W 3% V Pk -Pk Ripple & Noise (max.) (2) Max. Voltage Voltage Range (Min - Max) 343 Vdc 266 Vdc 171 Vdc 114 Vdc 86 Vdc 68 Vdc 57 Vdc 206V - 343V 160V - 266V 103V - 171V 68V - 114V 52V - 86V 41V - 68V 34V - 57V 90.5% 90.5% 90.5% 1% Line Regulation Load Regulation 3% Setup, Rise Time 0.6 S 90V ~ 305VAC Voltage Range 47Hz / 63Hz Frequency Range 0.99 @ 100VAC and 0.96 @ 220 VAC Input Power Factor Correction Efficiency (Typ.) at 230Vac 91% 91% 91% 90.5% 65A @ 230VAC Input and 25C Inrush Current 1 mA max. at 277 Vac 50Hz input Leakage Current 1.5 A / 100VAC AC Current (Typ.) ( yp ) Protections LEDWC( )120S210ST 0.75A / 220VAC Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C Latch mode. The power supply shall return to normal operation only after the power is turn-on again. Over Temperature Protection 446V 346V 222V 148V 112V 88V 74V Over Voltage (Typ.) Safety & EMC Environmental Protection type : latch-off mode, Power supply must turn off and on again Storage - 40 ~ +85C Operational 10 ~ 100% RH Humidity 5 ~100% R.H Storage Safety Standards UL8750 compliance to UL1310 Class 2 UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) Withstand Voltage I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute EMI Conduction & Radiation Harmonic Current EMS Immunity MTBF (3) Others - 35C ~ 65C Operational Temperature Range Life Time (3) Dimension (L*W*H) EN55015 with 6db margin EN61000-3-2 , EN61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 320K HRS Compliance: MIL-HDBK-217F @ 25C ambient temp. 80,000 hours @ 45C ambient temp. 194*67.5*37.0 (mm) -7.64*2.66*1.46 (inch) 1000 g Weight Autec Power Systems 667 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777 4/16/2010 Model Rated Current (1) Current Range (Min - Max) mA Rated Power LEDWC( )120S245ST LEDWC( )120S280ST LEDWC( )120S315ST LEDWC( )120S350ST LEDWC( )120S420ST 2450mA 2800mA 3150mA 3500mA 4200mA 4900mA 2327 - 2572 2660 - 2940 2992 - 3307 3325 - 3675 3990 - 4410 4655 - 5145 120W 120W 120W 120W 120W 120W 49 Vdc 43 Vdc 38 Vdc 34 Vdc 28 Vdc 24 Vdc 29V - 49V 26V - 43V 23V - 38V 20V - 34V 17V - 28V 14V - 24V 90% 89% 3% V Pk -Pk Output Ripple & Noise (max.) (2) Max. Voltage Voltage Range (Min - Max) 1% Line Regulation Load Regulation 3% Setup, Rise Time 3S 10% When Power On or Off Output Overshoot / Undershoot 90V ~ 305VAC Voltage Range 47Hz / 63Hz Frequency Range 0.99 @ 100VAC and 0.96 @ 220 VAC Input Power Factor Correction Efficiency (Typ.) at 230Vac 90.5% 90.5% 90.5% 90% 65A @ 230VAC Input and 25C Inrush Current 1 mA max. at 277 Vac 50Hz input Leakage Current 1.5 A / 100VAC AC Current (Typ.) Protections LEDWC( )120S490ST 0.75A / 220VAC Protection type : Hiccup mode, recovers automatically after fault condition is removed Short Circuit Protection 110C Latch mode. The power supply shall return to normal operation only after the power is turn-on again. Over Temperature Protection 64V 56V 49V 44V 36V 31V Over Voltage (Typ.) Safety & EMC Env vironmental Protection type : latch-off mode, Power supply must turn off and on again Temperature Range Storage - 40 ~ +85C Operational p 10 ~ 100% RH Humidity 5 ~100% R.H Storage Safety Standards UL8750 compliance to UL1310 Class 2 UL1012 UL935, CSA-C22.2 (No. 0, No 107.1, No. 250.0) Withstand Voltage I/P - O/P: 3KVAC (4242 DC) I/P - FG: 1.5KVAC (2121 DC) O/P-FG: 0.5KVAC (707 DC), 1 minute EMI Conduction & Radiation Harmonic Current EMS Immunity MTBF (3) Others - 35C ~ 65C Operational EN55015 with 6db margin EN61000-3-2 , EN61000-3-3 EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, EN 61547 320K HRS Compliance: MIL-HDBK-217F @ 25C ambient temp. Life Time (4+B148) 80,000 hours @ 45C ambient temp. Dimension (L*W*H) 194*67.5*37.0 (mm) -7.64*2.66*1.46 (inch) Weight Autec Power Systems 667 E Cochran St, Simi Valley, CA93065 1000 g www.autec.com Tel: (805)522-0888 Fax: (805)522-8777 4/16/2010 Mechanical Specification BLACK (ACL) DIMMING CONTROL WIRE (3*AWG #22) WHITE (ACN) GREEN (GND) YELLOW (10V) PURPLE (0~10V) AC IN (3*AWG #18) GREEN (GND) RED (V+) BLACK (V-) DC OUT (2*AWG #18) None Dimming model will not have the yellow, green and purple wires Model LEDWC( )120S035ST LEDWC( )120S045ST LEDWC( )120S070ST LEDWC( )120S105ST LEDWC( )120S140ST LEDWC( )120S175ST LEDWC( )120S210ST Efficiency @ Full Load and 115VAC (min) 88.0% 88.0% 88.0% 87.5% 87.5% 87.5% 87.5% Efficiency @ Full Load and 115VAC (typ) 89.0% 89.0% 89.0% 88.5% 88.5% 88.5% 88.5% Efficiency @ Full Load and 230VAC (min) 90.0% 90.0% 90.0% 89.5% 89.5% 89.5% 89.5% Efficiency @ Full Load and 230VAC (typ) 91.0% 91.0% 91.0% 90.5% 90.5% 90.5% 90.5% LEDWC( )120S490ST Model LEDWC( )120S245ST LEDWC( )120S280ST LEDWC( )120S315ST LEDWC( )120S350ST LEDWC( )120S420ST Efficiency @ Full Load Load and 115VAC 115VAC (min) (min) 87 5% 87.5% 87 5% 87.5% 87 0% 87.0% 87 0% 87.0% 87 0% 87.0% 87 0% 87.0% Efficiency @ Full Load and 115VAC (typ) 88.5% 88.5% 88.0% 88.0% 88.0% 88.0% Efficiency @ Full Load and 230VAC (min) 89.5% 89.5% 90.0% 90.0% 90.0% 90.0% Efficiency @ Full Load and 230VAC (typ) 90.5% 90.5% 91.0% 91.0% 91.0% 91.0% NOTES: 1. Measured at full load, 220VAC input and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth oscilloscope and the output paralleled a 0.1uf ceramic capacitor & 10 uf electrolytic capacitor. 3. For 2800mA output model, measured at 110VAC input, 80%load and 25 of ambient temperature. 4. For 2800mA output model, measured at 220VAC input, 80%load and 45 of ambient temperature. 5. All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25 of ambient temperature. 6. Specifications are subject to change without notice. AUTEC cannot be held liable for errors or omissions or the consequences thereof. 7. A suffix -XXXX may be added to denote variation or modifications to the base product, were X can be any alphanumeric character or blank Autec Power Systems 667 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777 4/16/2010 Dimming Control (On secondary side) Parameter Min. Typ. Max. 9.8V 10V 10.2V 10V output source current Absolute maximum voltage on the 1~10V input pin -10 mA - 10 mA 0V - 12V Source current on 1~10V input pin 0 mA - 1 mA 10V output voltage The dimmer control may be operated from either a potentiometer or from an input signal of 1 - 10 Vdc. Four recommended implementations are provided below. Io/Ir Vs Potentiometer 100% Io/Ir 80% LEDWCD120SxxxST 60% Io/Ir 40% 20% Implementation 1: Potentiometer control 0% 0 2 4 6 8 10 Vdim(V) Io/Ir Vs Vdim 100% 80% Io/Ir LEDWCD120SxxxST 60% Io/Ir 40% 20% Implementation 2: DC input 0% 0 2 4 6 8 10 Vdim(V) Io/Ir Vs Rx 100% Io/Ir 80% LEDWCD120SxxxST 60% Io/Ir 40% 20% Implementation 3: External resistor 0% 0 1.2k 2.4k 4.3k 6.8k 10k 15k 24k 39k 91k Rx Io/Ir Vs Vdim (at difference Rx) 100. 00% 80. 00% Io/Ir LEDWCD120SxxxST Rx=0R Rx=1.2k Rx=2.4K Rx=4.3K Rx=6.8K Rx=10k Rx=15k 60. 00% 40. 00% Implementation 4: External resistor and DC input 20. 00% 0. 00% 1 2 3 4 5 6 Vdim 7 8 9 10 Dimming notes: 1. If the dimming function is not used, please short 10V output pin (yellow) and 1-10 input pin (purple). 2. Io is actual output current and Ir is rated current without dimming control. 3. For the driver to operate properly, the load voltage must be maintained above the minimum voltage threshold (approx. 50% of the max. output voltage for any given model). 4. If the output voltage is maintained above 50% of the maximum output voltage, the dimming control may be operated over the entire 1-10V range with output current varying from 100% down to practically 10%. 5. The dimming signal is allowed to be less than 1V, however, when it for 0-1V, the output current cannot guarantee a good linearity. 6. The Rp, which stands for the potentiometer in the Implementation 1, is recommended between 10K~100K. 7. Do not connect the GND of dimming to the output; otherwise, the LED driver can not work normally. Autec Power Systems 667 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777 4/16/2010 Part Number Scheme LEDWC( )120SXXXST LED = LED driver T= Standard 3 Pin, UL W = wide range 90 305 VAC S = Standard Metal case with potting C = Constant Current XXX = Output current S = Single output ( ) = D for Dimming for none Dimming 120 = 120 Watt Derating Curve Derating Curve 100 Load(%) 80 60 40 20 0 -35 -20 -5 10 25 40 55 70 Ambient Temperature(C) Derating Curve 100 Load(%) 80 60 40 20 0 90 120 150 180 210 240 270 300 330 Input Voltage(V) Autec Power Systems 667 E Cochran St, Simi Valley, CA93065 www.autec.com Tel: (805)522-0888 Fax: (805)522-8777