CURRENT SENSORS
Fluxgate system / Voltage-output type
F01P***S05 SERIES rev A / May 2013
ABSOLUTE MAXIMUM RATINGS
Supply voltage Vcc V
Primary conductor temperature
Îp A
ESD(HBM: Human Body Model) kV
ISOLATION CHARACTERISTICS
lnsulation voltage Vd
lnsulation Resistance RIS
Clearance distance dCi
Creepage distance dCp
Case material
Comparative Tracking Index; (CTI) CTI V
Application example
ENVIRONMENTAL AND MECHANICAL CHARACTERISTICS
Ambient operating temperature Ta
Ambient storage temperature TS
Mass g
Parameters
Symbol
Unit
Value
Comment
7
110
Non repetitive primary current pulse(20μS),in powered or unpowered state.
20 × If
4
C=100pF,R=1.5kΩ
Parameters
Symbol
Unit
Value
Comment
AC4200V,for 1minute(Sensing current 0.5mA) 
Primary ⇔ Secondary
≧ 500MΩ(at DC500V)
Primary ⇔ Secondary
7.7mm(TYP)
Primary ⇔ Secondary
7.7mm(TYP)
Primary ⇔ Secondary
UL94 V-0
600
300V,CAT Ⅲ,PD2
Reinforced isolation,non
uniform field according to
EN50178,EN61010
600V,CAT Ⅲ,PD2
Simple isolation,non
uniform field according to
EN50178,EN61010
Parameters
Symbol
Unit
Value
Comment
MIN
TYP
MAX
-40
+105
-40
+105
12
            CURRENT SENSORS
SPECIFICATIONS Ta=+25℃,RL=10kΩ,Vcc=+5V
Rated Current F01P006S05 If A
F01P015S05
F01P025S05
F01P050S05
Maximum current(at Vcc=+5V,Ta=+105℃) F01P006S05 Ipmax A
F01P015S05
F01P025S05
F01P050S05
Supply Voltage Vcc V
Number of primary turns Np T
Number of secondary turns F01P006S05 Ns T
F01P015S05
F01P025S05
F01P050S05
Consumption current (at If) F01P006S05 Icc mA Icc=15+Ip(mA)/Ns
F01P015S05
F01P025S05
F01P050S05
Output voltage Vo V
Output voltage(at Ip=0A) Vo V
Electrical offset voltage F01P006S05 Voe mV
F01P015S05
F01P025S05
F01P050S05
Electrical offset current reffered to primary F01P006S05 Ioe A
F01P015S05
F01P025S05
F01P050S05
Temperature coefficient of Output voltage(at Ip=0A) F01P006S05 TCVo ppm/K
F01P015S05
F01P025S05
F01P050S05
Sensitivity(Theoretical value) F01P006S05 Gth mV/A
F01P015S05
F01P025S05
F01P050S05
Sensitivity error εG%
TCG ppm/K
Output Linearity εL%
Magnetic offset current reffered to primary(at 10×If) IOM A
Output current noise reffered to primary(at 100Hz~100kHz) F01P006S05 Ino μA/(Hz)1/2
F01P015S05
F01P025S05
F01P050S05
  Offset voltage value is after removal of core hysteresis.
Parameters
Symbol
Unit
Value
Comment
MIN
TYP
MAX
6
15
25
50
-20
20
-51
51
-85
85
-150
150
4.75
5.00
5.25
1,2,3
1816
1737
1764
1600
25
30
35
55
0.375
4.625
2.5
-10.40
10.40
-7.10
7.10
-6.25
6.25
-5.80
5.80
-0.10
0.10
-0.17
0.17
-0.25
0.25
-0.46
0.46
±10.0
±80.0
ppm/K of 2.5V
±7.5
±70.0
(-40℃~+105℃)
±6.5
±60.0
±6.0
±60.0
104.2
625mV/If
41.67
25
12.5
-0.7
0.7
Temperature coefficient of Sensitivity(at Ta=-40℃~+105℃)
±40
-0.1
0.1
-0.1
0.1
36
RL=1kΩ
90
150
300
             CURRENT SENSORS
SPECIFICATIONS Ta=+25℃,RL=10kΩ,Vcc=+5V
Peak to peak output ripple at oscillator freqency(f typ=450kHz) F01P006S05 mV
F01P015S05
F01P025S05
F01P050S05
Reaction time(at 10% of If ) F01P006S05 tra μs
F01P015S05
F01P025S05
F01P050S05
Response time 1 (at 90% of If ) F01P006S05 tr μs
F01P015S05
F01P025S05
F01P050S05
Response time 2 (at 10% of If to 90% of Vo ) tr μs
Frequency bandwidth(±1dB) BW kHz
Frequency bandwidth(±3dB) BW kHz
Output Voltage Accuracy(Overall) F01P006S05 XG%
F01P015S05
F01P025S05
F01P050S05
STANDARDS
      ※Please refer to the another sheet about conditions of UL Recognition.
Characteristic curve(TYP)
                  Figure 1:Linearity curve
Figure 2:Frequency response curve
     ex)F01P025S05
Measurement condition Ta=+25℃,RL=1kΩ,Ip=3A,Vcc=+5V
Parameters
Symbol
Unit
Value
Comment
MIN
TYP
MAX
40
160
RL=1kΩ
15
60
10
40
5
20
0.3
RL=1kΩ,di/dt=18A/μs
0.3
RL=1kΩ,di/dt=44A/μs
0.3
RL=1kΩ,di/dt=68A/μs
0.3
RL=1kΩ,di/dt=100A/μs
0.3
RL=1kΩ,di/dt=18A/μs
0.3
RL=1kΩ,di/dt=44A/μs
0.3
RL=1kΩ,di/dt=68A/μs
0.3
RL=1kΩ,di/dt=100A/μs
0.6
RL=1kΩ,di/dt=If/μs
200
RL=1kΩ
300
RL=1kΩ
2.5
XG=(100×Voe/625)+εGL
1.9
1.8
1.7
Ip
2.5
(4.625)
5
0If
-If
-Ipmax
(≒-If×3
Ipmax
(≒If×3
(0.375)
Output Voltage
VoV
Primary
current
IpA
             CURRENT SENSORS
SUPPORT DOCUMENTATION
Maximum continuous DC primary current
         Figure 3Ip vs Ta for
F01P006S05
Figure 4:Ip vs Ta for F01P015S05
        Figure 5Ip vs Ta for F01P025S05 Figure 6:Ip vs Ta for F01P050S05
According to which the following conditions are true the maximum continuous DC primary current plot shows the boundary of the area.
  ①Ip < Ipmax
  ②Junction temperature Tj < 125℃
  ③Primary conductor temperature < 110℃
Frequency derating
   Figure 7Maximum RMS AC primary current/maximum DC primary current vs frequency
Ip(A)
Ip(A)
Ip(A)
Ip(A)
            CURRENT SENSORS
CONNECTION
DIMENSIONS(mm)
RECOMMENDED HOLE DIAMETER(mm)
If/3
123
10 9 8
IN
OUT
123
10 9 8
IN
OUT
123
10 9 8
IN
OUT
If/2
If
Int REF
40kΩ
40kΩ
10kΩ
10kΩ
Rm 11
12
13
1Ω
10pF
1,2,3
8,9,10
Ip
IN
OUT
Vo
GND
Vcc
+
-
OUT