221 WEST INDUSTRY COURT
DEER PARK, NY 11729-4681
PHONE (631) 586-7600
FAX (631) 242-9798
World Wide Web - http://www.sensitron.com
E-Mail - sales@sensitron.com
SENSITRON
SEMICONDUCTOR
TECHNICAL DATA
DATA SHEET 4088, REV. -
HERMETIC POWER SCHOTTKY RECTIFIER
Ultra Low Reverse Leakage
DESCRIPTION: A 100 VOLT, 15 AMP, POWER SCHOTTKY RECTIFIER IN A HERMETIC LCC-5 PACKAGE.
MAXIMUM RATINGS ALL RATINGS ARE @ TC = 25
C UNLESS OTHERWISE SPECIFIED.
RATING SYMBOL MAX. UNITS
PEAK INVERSE VOLTAGE PIV 100 Volts
MAXIMUM DC OUTPUT CURRENT (@ TC=100 OC) IO15 Amps
MAXIMUM NONREPETITIVE FORWARD SURGE CURRENT
(t = 8.3ms, Sine) IFSM 250 Amps
MAXIMUM JUNCTION CAPACITANCE (Vr = 5V, TJ, = 25C,
fSIG = 1MHz, VSIG = 50mV P-P)) CT500 pF
MAXIMUM THERMAL RESISTANCE (Junction to Case) R
JC 1.21 C/W
Weight (typical) --- 1 g
MAXIMUM OPERATING TEMPERATURE RANGE Top -65 to
+ 200
C
MAXIMUM STORAGE TEMPERATURE RANGE Tstg -65 to
+ 175
C
ELECTRICAL CHARACTERISTICS
CHARACTERISTIC SYMBOL MAX. UNITS
MAXIMUM FORWARD VOLTAGE DROP, Pulsed (If = 15 Amps)
TJ = 25 C
TJ = 125 C
Vf0.93
0.77
Volts
MAXIMUM REVERSE CURRENT (Ir @ 100 V PIV)
TJ = 25 C
TJ = 125 C
Ir0.1
1.0
mA
15LJQ100
221 WEST INDUSTRY COURT
DEER PARK, NY 11729-4681
PHONE (631) 586-7600
FAX (631) 242-9798
World Wide Web - http://www.sensitron.com
E-Mail - sales@sensitron.com
TECHNICAL DATA
DATA SHEET 4088, REV. -
MECHANICAL DIMENSIONS: IN Inches / mm
PINOUT TABLE
DEVICE TYPE PIN 1 PIN 2 PIN 3
SINGLE RECTIFIER CATHODE ANODE ANODE
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Forward Voltage Drop - V
F (V)
10-2
10-1
100
101
Instantaneous Forward Current - I
F
(A)
Typical Forward Characteristics
125 °C
200 °C
175 °C
25 °C
0 20 40 60 80 100 120
Reverse Voltage - VR (V)
10-4
10-3
10-2
10-1
100
101
Instantaneous Reverse Current - I
R
(mA)
Typical Reverse Characteristics
25 °C
50 °C
75 °C
100 °C
125 °C
150 °C
200 °C
175 °C
0 20 40 60 80 100 120
Reverse Voltage - VR (V)
100
200
300
400
Junction Capacitance - C
T
(pF)
Typical Junction Capacitance
Note: VF Curves are shown for die only.
15LJQ100
LCC-5
SINGLE
1 2 3
221 West Industry Court Deer Park, NY 11729-4681 (631) 586-7600 FAX (631) 242-9798
World Wide Web - http://www.sensitron.com E-Mail Address - sales@sensitron.com
SENSITRON
SEMICONDUCTOR
TECHNICAL DATA
DISCLAIMER:
1- The information given herein, including the specifications and dimensions, is subject to change without prior notice to improve product
characteristics. Before ordering, purchasers are advised to contact the Sensitron Semiconductor sales department for the latest version
of the datasheet(s).
2- In cases where extremely high reliability is required (such as use in nuclear power control, aerospace and aviation, traffic equipment,
medical equipment, and safety equipment), safety should be ensured by using semiconductor devices that feature assured safety or by
means of users’ fail-safe precautions or other arrangement.
3- In no event shall Sensitron Semiconductor be liable for any damages that may result from an accident or any other cause during
operation of the user’s units according to the datasheet(s). Sensitron Semiconductor assumes no responsibility for any intellectual
property claims or any other problems that ma y result from applications of information, products or circuits described in the datasheets.
4- In no event shall Sensitron Semiconductor be liable for any failure in a semiconductor device or any secondary damage resulting from
use at a value exceeding the absolute maximum rating.
5- No license is granted by the datasheet(s) under any patents or other rights of any third party or Sensitron Semiconductor.
6- The datasheet(s) may not be reproduced or duplicated, in any form, in whole or part, without the expressed written permission of
Sensitron Semiconductor.
7- The products (technologies) described in the datasheet(s) are not to be provided to any party whose purpose in their application will
hinder maintenance of international peace and safety nor are they to be applied to that purpose by their direct purchasers or any third
party. When exporting these products (technologies), the necessary procedures are to be taken in accordance with related laws and
regulations.