MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 1 of 7
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
FEATURES
ITE (2nd) and Medical 3rd ed. 1MOPP (primary-
secondary) safety approved
120W compact high density
2" x 4" standard footprint
High effi ciency up to 91%
Universal AC input with active PFC
Low profi le - 1U package
Convection-cooled operation up to 75W
RoHS compliant
UL Class I and II approved (for IT equipment)
DESCRIPTION
The MVAB120 series switching power supplies
utilize advanced component and circuit
technologies to deliver high effi ciency. Designed
for Medical, Telecom, and Industrial applications
to satisfy 1U height design considerations, the
MVAB120 Series measures only 2.0" x 4.0"
x 1.35". All models offer universal AC input
with active power factor correction (PFC) and
compliance to worldwide safety and EMC
standards.
ORDERING GUIDE
Model Number Medical Approval1Natural Convection Cooling Forced Air Cooling Main Output
(V1)
MVAB120-12 No
75W 120W @ 250LFM
12V
MVAB120-12-01 Yes
MVAB120-24 No 24V
MVAB120-24-01 Yes
MVAB120-28 No 28V
MVAB120-28-01 Yes
MVAB120-48 No 48V
MVAB120-48-01 Yes
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Input Voltage Operating Range Single phase 90 120/230 264 Vac
DC1120 300 Vdc
Input Frequency 47 50/60 63 Hz
Turn-on Input Voltage Input rising at 75W 76 85 Vac
Turn-off Input Voltage Input falling at 75W 50
Input Current 90Vac input, full load 1.9 A
Inrush Current At 264Vac, at 25°C cold
start 75 Apk
OUTPUT CHARACTERISTICS
Model Number Main Output
Voltage (V1) Load Current Load Capacitance Line, Load, Cross
Regulation
Typical Effi ciency
@230Vac full load
MVAB120-12 12V 0 to 10.0A 0 to 3300μF ± 2% 88%
MVAB120-12-01
MVAB120-24 24V 0 to 5.0A 0 to 1000μF ± 2% 90%
MVAB120-24-01
MVAB120-28 28V 0 to 4.29A 0 to 1000μF ± 2% 90%
MVAB120-28-01
MVAB120-48 48V 0 to 2.5A 0 to 1000μF ± 2% 91%
MVAB120-48-01
MAIN OUTPUT CHARACTERISTICS (ALL MODELS)
Parameter Conditions Min. Max. Units
Transient Response 50% load step, 1A/μsec slew rate ± 5 %
Settling Time to 1% of Nominal MVAB120-12 750 μsec
MVAB120-24, MVAB120-28, MVAB120-48 500 μsec
Turn On Delay After application of input power 1 sec
Output Voltage Rise Monotonic, 0 to 75W 50 msec
Setpoint Accuracy 120Vac, 75W, 25°C ± 0.5 %
Output Holdup Full load 14 msec
Temperature Coeffi cient 0.02 %/°C
Ripple Voltage & Noise21%
1 Medical versions not designed for DC input voltage.
2 Ripple and noise are measured with 0.1 μF of ceramic capacitance and 47 μF of electrolytic capacitance on each
of the power supply outputs. The output noise requirements apply over a 0 Hz to 20 MHz bandwidth. A short
coaxial cable with 50Ω scope termination is used.
3 Unless otherwise specifi ed, all readings are taken at 120Vac input and 25°C ambient temperature.
CB
Test Certi cate
and Test Report
Available now at
www.murata-ps.com/en/3d/acdc.html
*LAST TIME BUY: 2/28/2019. CLICK HERE FOR DISCONINUANCE NOTICES.*LAST TIME BUY: 2/28/2019. CLICK HERE FOR DISCONINUANCE NOTICES.
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 2 of 7
www.murata-ps.com/support
ENVIRONMENTAL CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Storage Temperature Range -40 85
°C
Operating Temperature Range
Full load -10 50
50% load -10 70
Start up -20
Operating Humidity Non-condensing 10 95 %
Operating Altitude Without derating -200 3000 m
MTBF Telcordia SR-332 M1C3 25°C 1M Hours
Shock
Operating, IEC60068-2-27, half-sine 5G, 6ms, 3 times per face,
6 faces Complies
Non-operating, IEC60068-2-27, half-sine, 30G, 18ms, 3 times
per face, 6 faces Complies
Vibration
Operating, IEC60068-2-6, 1.0G, 10-150Hz, 10minutes per axis,
on all 3 axes Complies
Non-operating, IEC60068-2-6, 2.0G, 10-150Hz, 10minutes per
axis, on all 3 axes Complies
Safety
IEC60950-1:2005 (2nd Edition); Am1:2009
UL60950-1 2nd Edition,2011-12-19, CSA C22.2 No. 60950-1-07, 2nd Edition,2011-12
EN60950-1:2006 + A11:2009 + A1:2010 + A12:2011
IEC60601-1:2005 + CORR.1(2006) + CORR.2(2007)
ANSI/AAMI ES60601-1 (2005+C1:09 + A2:10), CSA-C22.2 No. 60601-1(2008), MOPP
CE Marking per LVD
Warranty 2 years
Outside Dimensions 2.0" x 4.0" x 1.35" (50.8mm x 101.6mm x 34.3mm); 2.0" x 4.0" x 1.41" (50.8mm x 101.6mm x 35.8mm) for medical version
Weight MVAB120-12/-01 0.34lbs (155g) typical
MVAB120-24/-01, MVAB120-28/-01, MVAB120-48/-01 0.36lbs (162g) typical
PROTECTION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Overvoltage Protection Latching 110 160 %V1
Overcurrent Protection Hiccup mode 105 150 %Amax
Overtemperature Protection Auto recovery Complies
ISOLATION CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Isolation
Primary to Earth Ground (1MOOP) 1500 Vac
Primary to Secondary (2MOOP or 1 MOPP) 3000
Secondary to Earth Ground 500 Vdc
Leakage Current (under normal conditions) 264Vac, 60Hz, 25°C 500 μA
EMISSIONS AND IMMUNITY
Characteristic Standard Compliance
Input Current Harmonics IEC/EN 61000-3-2 Class A
Voltage Fluctuation and Flicker IEC/EN 61000-3-3 Complies
Conducted Emissions EN 55022 Class B, Class A (at class II equipment)
FCC Part 15 Class B, Class A (at class II equipment)
ESD Immunity IEC/EN 61000-4-2 Level 4, Criterion A
Radiated Field Immunity IEC/EN 61000-4-3 Level 2, Criterion A
Electrical Fast Transient Immunity IEC/EN 61000-4-4 Level 3, Criterion A
Surge Immunity IEC/EN 61000-4-5 Level 3, Criterion A
RF Conducted Immunity IEC/EN 61000-4-6 Level 2, Criterion A
Magnetic Field Immunity IEC/EN 61000-4-8 Level 1, Criterion A
Voltage dips,interruptions IEC/EN 61000-4-11 Level 3, Criterion B
PERFORMANCE DATA
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 3 of 7
www.murata-ps.com/support
70
75
80
85
90
95
012345678910
MVAB120-12 Eĸciency (%)
Output Current (A)
90Vac 120Vac 230Vac 264Vac
012345678
Output Current (A)
90Vac 120Vac 230Vac 264Vac
MVAB120 15 Eĸciency (%)-
70
75
80
85
90
95
00.511.522.533.544.55
Output Current (A)
90Vac 120Vac 230Vac 264Vac
MVAB120 24 Eĸciency (%)-
70
75
80
85
90
95
01234
Output Current (A)
90Vac 120Vac 230Vac 264Vac
MVAB120 28 Eĸciency (%)-
70
75
80
85
90
95
0 0.5 1 1.5 2 2.5
Output Current (A)
90Vac 120Vac 230Vac 264Vac
MVAB120 48 Eĸciency (%)-
70
75
80
85
90
95
0
10
20
30
40
50
60
70
80
90
100
110
120
130
        
Output power [W]
Ambient temperature [°C]
MVAB120-12, MVAB120-15, MVAB120-24, and MVAB120-28 dŚĞƌŵĂůĞƌĂƟŶŐ
ConvecƟon cooling
DirecƟon1-5
Forced air cooling (250LFM)
DirecƟon1-5
Forced air cooling (350LFM)
DirecƟon1-5
0
10
20
30
40
50
60
70
80
90
100
110
120
130
        
Output power [W]
Ambient temperature [°C]
MVAB120- 48 Thermal DeraƟng
ConvecƟon cooling
DirecƟon1-5
Forced air cooling (200LFM)
DirecƟon1-5
Inrush waveform
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 4 of 7
www.murata-ps.com/support
MECHANICAL DIMENSIONS – MVAB120-12
Dimensions: 2.0" x 4.0" x 1.35" (50.8mm x 101.6mm x 34.3mm)
EMI CONSIDERATIONS
For optimum EMI performance, the power supply should be mounted to a metal plate grounded to all 4 mounting holes of the power supply. To comply with
safety standards, this plate must be properly grounded to protective earth (see mechanical dimension notes). Pre-compliance testing has shown the stand-
alone power supply to comply with EN55022 class A radiated emissions. Radiated emission results vary with system enclosure and cable routing paths.
SAFETY CONSIDERATIONS
1. This power supply is a component level power supply intended for use in class I or class II applications. Secondary ground traces need to be suit-
ably isolated from primary ground traces when used in class II applications.
2. When the power supply is used in class II equipment, all ground traces and components connected to the primary side are considered primary for
spacing and insulation considerations.
3. Double pole/neutral fusing (-01 medical versions only).
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 5 of 7
www.murata-ps.com/support
MECHANICAL DIMENSIONS – MVAB120-12-01 (MEDICAL VERSION)
Dimensions: 2.0" x 4.0" x 1.41" (50.8mm x 101.6mm x 35.8mm)
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 6 of 7
www.murata-ps.com/support
MECHANICAL DIMENSIONS – MVAB120-24, MVAB120-28, and MVAB120-48
Dimensions: 2.0" x 4.0" x 1.35" (50.8mm x 101.6mm x 34.3mm)
MVAB120 Series
120W 2" x 4" AC-DC Power Supply Converter
MVAB120.A13 Page 7 of 7
www.murata-ps.com/support
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfi eld, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating require-
ments and the Life and Safety Critical Application Sales
Policy. Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. (“Murata”) makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the
granting of licenses to make, use, or sell equipment constructed in accordance therewith. Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards that anticipate dangerous consequences of failures, monitor failures and their consequences, lessen
the likelihood of failures that might cause harm, and take appropriate remedial actions. Buyer will fully indemnify Murata, its affi liated companies, and its representatives against any damages arising out of the use of any Murata products in safety-critical applications. Specifi cations are subject
to change without notice. © 2014 Murata Power Solutions, Inc.
MECHANICAL DIMENSIONS – MVAB120-24-01, MVAB120-28-01, and MVAB120-48-01 (MEDICAL VERSION)
Dimensions: 2.0” x 4.0” x 1.41” (50.8mm x 101.6mm x 35.8mm)
INPUT/OUTPUT CONNECTOR AND SIGNAL SPECIFICATION AND MATING CONNECTORS
PIN Description Mating Housing Crimp terminal/pins
Input Connector CN1 : Molex 26-62-4030
Molex 09-50-8031 with locking ramp Molex 6838 Series
1 AC Neutral
3 AC Line
Spade Connector: #250
GND Earth Ground
Output Connector CN2 : Molex 26-60-4060
Molex 09-50-8061 with locking ramp Molex 6838 Series
1, 2, 3 DC Return
4, 5, 6 V1