4
1
2
4
5
6
7
8
9
10
2
1
4
5
6
7
8
9
10
4
Light curtain type XUSLBQ6Apppp
XUSLDMQ6Apppp
0.55 in. (14 mm)
XUSLBR5Apppp
1.18 in. (30 mm)
XUS LDMY5Appppp
1.18 in. (30 mm)
Environment characteristics
Conformity to standards ANSI/RIA R15.06, ANSI B11:19-1990, OSHA 1910.217(C), OSHA 1910.212,
EN/IEC 61496-1 and EN/IEC 61496-2 and IEC 61508-1, 2 (Type 4 ESPE)
Certications e, TUV, UL, CSA
European directives Machinery directive 98/37/EC, Work equipment directive 89/655/EEC and
EMC directive 89/336 EEC
ROHS directive 2002/95/EC
Ambient air temperature Operating °F (°C) 14…+ 131 (- 10…+ 55)
For storage °F (°C) - 13…+ 167 (- 25…+ 75)
Relative humidity 95% maximum, without condensation
Degree of protection IP 65
Shock and vibration
resistance
Conforming to IEC 61496-1 Shock resistance: 10 gn, impulse 16 ms
Vibration resistance: 10…55 Hz, amplitude: 0.35 ± 0.05 mm
Materials Casing: aluminium with electrostatically applied red (RAL 3000) polyester paint nish;
end caps: 20% berglass impregnated polycarbonate.
Mounting End brackets (included)
Optical characteristics
Minimum detection capacity (MOS) 0.55 in. (14 mm) (nger) 1.18 in. (30 mm) (hand)
Nominal sensing distance (Sn) ft (m) 1…23 (0.3…7) or
9.8 (3) with PDM (1)
1…26.2 (0.3…8) or
65.6 (20) with PDM (1)
1…65.6 (0.3…20) or
26.2 (8) with PDM (1)
Protected height in
(mm)
11…53.5 (280…1360) 12.6…83.5 (320…2120)
Effective aperture angle (EAA) 2.5° at 9.8ft. (3 m) (3° when used with IP 67 protection tube)
Light source GaAIAs LED, 880 nm
Immunity to ambient light Conforming to IEC/EN 61496-2
Electrical characteristics
Response time ms 23…41 23…32
Power supply c 24 V ± 20% 2 A conforming to EN/IEC 61496 and EN/IEC 60204-1
Transmitter mA 285
Receiver A1.8 (with maximum load)
Maximum current
consumption (no-load)
Transmitter mA 285
Receiver mA 450
Immunity to interference Conforming to EN 61496-1
Safety outputs OSSD (Output Signal Switching Devices) 2 solid-state PNP (N/O) outputs y 625 mA, c 24 V (Short-circuit protected)
Auxiliary output 1 solid-state output 100 mA, c 24 V, PNP or NPN (depending on model)
Monitoring activation of output switching devices
(MPCE/EDM)
50 mA, c 24 V and start/restart 10 mA
Signalling Transmitter 1 LED (power supply)
Receiver 4 LEDs (stop, run, interlock, ECS/B Blanking or FB Floating Blanking)
Connections (2)
Light curtains Transmitter M12, 5-pin, female connector
Receiver M12, 8-pin, female connector
Segments XUSLDS Transmitter/Receiver M12, 4-pin, female connector on ying lead
XPSLCM1 Receiver M12, 4-pin, female connector
Pre-wired connectors c.s.a. Transmitter/Receiver 22 AWG (0.32 mm2) conductors with M12, 5-pin, male connector
Receiver 22 AWG (0.32 mm2) conductors with M12, 8-pin, male connector
Jumper cables c.s.a. Transmitter/receiver 22 AWG (0.32 mm2) conductors with M12, 4-pin, male/female connectors
Cable resistance of pre-wired
connectors
Transmitter/receiver W0.1686 per ft. (0.05531 per m)
Cable lengths Pre-wired connectors with cable lengths of 16.4, 32.8, 49.2, and 98.4 ft (5, 10, 15 and
30 m) are available separately. The maximum cable length is 196.9 ft (60 m),
depending on the load current and power supply.
(1) PDM: Programming and Diagnostic Module, available as option, see page 10.
(2) Pre-wired connectors to be ordered separately, see page 10.
General:
page 2
Characteristics:
page 4
References:
page 6
Dimensions:
page 12
Wiring Diagrams:
page 14
Characteristics
Safety detection solutions
Safety light curtains, type 4
Light curtains Optimum XUSLB and