REVISIONS REV A B C D DESCRIPTION ISSUE 1 REVISIED OPERATING TEMP ON PAGE 4. OVP FOR 48V ON PAGE 2. REMOTE ON/OFF ON PAGE 2. CHANGED CN4 ON PAGE 5 CHANGED D (MODELS - H & J ON PAGE 4 REVISED NOTE D. FOR -H &J: SWITCHED WITH & WITHOUT COVER TEMPS FILE NAME: CAD1:MSWORD:PA211242.DOC SCALE: NONE TITLE: DOCUMENT NUMBER: OVS-U (UNIVERSAL INPUT) SERIES SPECIFICATION 43352 BUSINESS PARK DRIVE * TEMECULA * CA * 92590 TEL: (951) 699-1270 * FAX: 9516769482 REV: DATE ISSUED BY 07/02/02 / RJ 07/12/02 11/20/03 06/26/06 RJ JC YS D SH 1 OF 7 P-A2-11242 PREPARED BY: K. BRENNAN 06/26/06 ENGINEERING: M. PITCHAI 06/26/06 Y. SEKIGUCHI 06/26/06 APPROVED: PROPRIETARY NOTICE: THIS DRAWING PRINT OR DOCUMENT AND SUBJECT MATTER DISCLOSED HEREIN ARE PROPRIETARY ITEMS TO WHICH TAMURA RETAINS THE EXCLUSIVE RIGHT OF DISSEMINATION, REPRODUCTION, MANUFACTURE AND SALE. THIS DRAWING, PRINT OR DOCUMENT IS SUBMITTED IN CONFIDENCE FOR CONSIDERATION BY THE RECIPIENT ALONE UNLESS PERMISSION FOR FURTHER DISCLOSURE IS EXPRESSLY GRANTED IN WRITING. A. Electrical Specifications (1) AC Input Voltage Rating DC Input Voltage Range AC100 - 230V, 50/60Hz (47 - 63Hz) AC90 - 264V ------E Series AC90 - 132VAC / AC180 - 264V ------F to J Series (Automatic voltage selection) DC115 - 372V ------E Series DC230 - 372V ------F to J Series with JW1 open (2) Input Surge Current 35A MAX for E Series at nominal line (115/230V) cold start 30A MAX for F to J Series at nominal line (115/230V) cold start (3) DC Output Adjustment Range 10% MIN 24V output: 22.8V to 29.2V (4) Line Regulation 0.5% MAX under specified input range (5) Load Regulation 0.5% MAX from no load to full rated load (6) Output Ripple and Noise 3/5 - 15V output 75mVp-p MAX 24V output 120mVp-p MAX 28, 48V output 240mVp-p MAX DC to 20MHz BW (7) Hold-up Time 20msec MIN under nominal line and rated load (8) Output Transient Response 1msec MAX over 2% of rated voltage under 50 - 100% load change (9) Output Voltage Rise Time 100msec MAX, from 10% to 90% of rated output voltage (10) Efficiency 70% MIN at nominal line and rated load (11) Overload Protection 120% TYP of rated load, fold-back limiting type (12) OverVoltage Protection 3V output 5V output 12V output 15V output 24/28V output 48V output (13) Leakage Current 0.75mA rms MAX (14) Overshoot No overshoot during turn ON/OFF (15) Output Voltage Stability 0.1% MAX for 8 hours after 20 minute warm-up (16) Temperature Coefficient 0.03% per deg. C MAX (17) Remote/Local Sensing Built-in (18) Remote ON/OFF Control Built-in F, G, H and J Series, 300uA MIN < 1V for inhibit, > 4.5V (or open) for ON FILE NAME: CAD1:MSWORD:PA211242.DOC SCALE: NONE 3.8 - 4.6V 5.7 - 6.7V 14.25 - 15.75V 17.25 - 18.75V 31.0 - 34.5V 54.0 - 62.0V REV: D DATE:06/26/06 TITLE: OVS-U (UNIVERSAL INPUT) SERIES 43352 BUSINESS PARK DRIVE * TEMECULA * CA * 92590 TEL: (951) 699-1270 * FAX: 9516769482 DOCUMENT NUMBER: P-A2-11242 SH 2 OF 7 19) AC Power Fail Signal Built-in on 5V output models only, other voltages optional Power Good Logic "0" Power Fail Logic "1", 5msec MIN pulse width, output 4.5V 5% 20) Current Sharing Current sharing capability available by using CS terminal and external circuit 21) Surge Voltage Test Meets IEEE587 C62.41 test method with no damage to power supply 22) Withstand Voltage AC 3KV (Input - Output), AC 1.5KV (Input - Chassis ground) 23) Insulation Resistance 50Mohm MIN DC500V (Input - Output) 24) Part Number Description OVS - - U Model No. Series Name U: No cover (Standard) UC: With cover (Option) Output voltage Case size CASE SIZE E F MODEL OVS-5E-UC OVS-12E-UC OVS-15E-UC OVS-24E-UC OVS-48E-UC OVS-5F-UC OVS-12F-UC OVS-15F-UC OVS-24F-UC OVS-48F-UC OVS-5G-UC G OVS-12G-UC OVS-15G-UC OVS-24G-UC OVS-48G-UC OVS-5H-UC H OVS-12H-UC OVS-15H-UC OVS-24H-UC OVS-48H-UC OVS-5J-UC J OVS-12J-UC OVS-15J-UC OVS-24J-UC OVS-48J-UC * INDICATES A DUAL RATING FILE NAME: CAD1:MSWORD:PA211242.DOC VOLTS AMPS 5 12 15 24 48 3.2 * 5* 12 15 24 * 28 * 48 3.2 * 5* 12 15 24 * 28 * 48 3.2 * 5* 12 15 24 * 28 * 48 3.2 * 5* 12 15 24 * 28 * 48 0-10 0-5 0-4 0-2.5 0-1.2 2-20 * 0-20 * 0-10 0-8 0-5 * 0-3.8 * 0-2.3 3-30 * 0-30 * 0-15 0-12 0-8 * 0-6 * 0-3.7 4.5-45 * 0-45 * 0-22 0-18 0-12 * 0-9.2 * 0-5.5 6-60 * 0-60 * 0-30 0-25 0-16 * 0-12.2 * 0-7.3 SCALE: NONE REV: D DATE:06/26/06 TITLE: OVS-U (UNIVERSAL INPUT) SERIES 43352 BUSINESS PARK DRIVE * TEMECULA * CA * 92590 TEL: (951) 699-1270 * FAX: 9516769482 DOCUMENT NUMBER: P-A2-11242 SH 3 OF 7 Note 1. Output ripple and noise to be measured with a 4.7uF +0.1 uF film or ceramic capacitor measured at points A as shown below. Note 2. Output voltage to be measured at output terminals, Points B as shown below. Note 3. OVS-5*-U has a dual rating of 3.2V and 5V. The unit is shipped from the factory set to 5V. To obtain 3.2V, the unit must be modified according to the instructions. Note 4. OVS-24*-U has a dual rating of 24V and 28V. The unit is shipped from the factory set to 24V. To obtain 28V, customer must readjust the output voltage potentiometer. POINT B OUTPUT POINT A Measuring Points + POWER SUPPLY + 0.1 uF LOAD 4.7uF OUTPUT POINT B A: Output Ripple and Noise B: Output Voltage Capacitors 4.7uF: Low ESR Electrolytic 0.1uF: Polyester film or ceramic POINT A 150mm +/-10mm (5.9" +/-0.4") B. Safety Meets UL1950, C22.2 No. 234, EN60950, VDE0805 C. EMI Meets FCC20780 Part 15J Class B E, F Series Class A G, H, J Series VDE 0871 Class B E, F Series Class A G, H, J Series VCC1 Class 2 E, F Series Class 1 G, H, J Series Note 1. Models OVS-48E-UC and -48F-UC meet Class A for FCC and VDE and meet Class 1 with VCC1 D. Environmental (1) Operating Temperature MODELS -E, F & G: 0 to +40 deg. C with cover, 0 to +50 deg. C without cover* In either case, the temperature at the center portion on the side of the chassis should be +60 deg. C MAX. For operation above +40 with cover (+50 deg. C without cover) derate linearly to 50% load at +55 deg. C with cover (+65 deg. C without cover). In either case, the temperature at the center portion on the side of the chassis should be +70 deg. C MAX. * Ambient temperature to be measured at 1" above the main transformer. MODELS -H & J: 0 to +40 deg. C with cover, 0 to +50 deg. C without cover* In either case, the temperature at the center portion on the side of the chassis should be +60 deg. C MAX. For operation above +40 deg. C without cover (+50 deg. C with cover) derate linearly to 50% load at +55 deg. C without cover (+65 deg. C with cover). In either case, the temperature at the center portion on the side of the chassis should be +70 deg. C MAX. *Ambient temperature to be measured at 1" above the main transformer (2) Storage Temperature -20 to +85 deg. C FILE NAME: CAD1:MSWORD:PA211242.DOC SCALE: NONE REV: D DATE: 06/26/06 TITLE: OVS-U (UNIVERSAL OUTPUT) SERIES 43352 BUSINESS PARK DRIVE * TEMECULA * CA * 92590 TEL: (951) 699-1270 y FAX: 9516769482 DOCUMENT NUMBER: P-A2-11242 SH 4 OF 7 (3) Operating Humidity 10 - 90% RH, non condensing (4) Storage Humidity 10 - 95%, non condensing (5) Vibration 10 - 55Hz, 2G (All axis, 1 hour) (6) Shock 20msec, 20G (All axis, 3X ea.) E. Power Factor Correction Use Tamura Part Number PFC-500 as an external active filter power supply for OVS-E through J Series F. Input and Output terminals Input Output *I/O Terminal Screws: M4 CN1 (Remote sense) Pin Assignment #1 pin +Sense #2 pin -Sense CN2 (Input / Output Signal) Pin Assignment #1 pin CS (Current sharing, external circuit required) #2 pin AC Power Fail signal output (+5V only, other voltages optional) #3 pin SG (Signal Ground) #4 pin Remote ON/OFF (not available on E Series) CN3, CN4 Jumper Tip Position CN3 +OUT CN4 -OUT #1 Front side of Power Supply Short for Remote Sensing (Use CN1) Short for Local Sensing (CN1 not used) CN1 Part No: Mating Part No: 5273-02A/Molex 5195-02 or 5239-02/Molex FILE NAME: CAD1:MSWORD:PA2112421.DOC SCALE: NONE REV: D DATE: 06/26/06 SH 5 OF 7 TITLE: OVS-U (UNIVERSAL OUTPUT) SERIES SPECIFICATION 43352 BUSINESS PARK DRIVE y TEMECULA y CA y 92590 TEL: (951) 699-1270 y FAX: 9516769482 DOCUMENT NUMBER: P-A2-11242 CN2 Part No: 5045-03A/Molex ----E Series 5045-04A/Molex ----F through J Series 5102-03 or 5051-03/Molex ---- E Series 5012-04 or 5051-04/Molex ----F through J Series 5548-03A/Molex 90059-0013/Molex Mating Part No: CN3, 4 Part No: Tip Part No: G. Mechanical Specifications dimensions shown in mm (inches). See sheet 7 for drawing representations MODEL OVS-E OVS-F OVS-G OVS-H OVS-J TOLERANCES A B C D E F G H R S 117.3 12.7 76.29 12.7 104.6 124 25.4 50.8 12.7 76.2 (4.62) (0.50) (3.00) (0.50) (4.12) (4.88) (1.00) (2.00) (0.50) (3.00) 180.3 38.1 114.3 12.7 104.6 124 30.2 60.2 38.1 114.3 (7.10) (1.50) (4.50) (0.50) (4.12) (4.88) (1.19) (2.37) (1.50) (4.50) 218.4 12.7 177.8 12.7 104.6 124 30.2 60.2 12.7 177.8 (8.60) (0.50) (7.00) (0.50) (4.12) (4.88) (1.19) (2.37) (0.50) (7.00) 269.2 12.7 228.6 12.7 104.6 124 33.3 66.0 12.7 228.6 (10.60) (0.50) (9.00) (0.50) (4.12) (4.88) (1.31) (2.60) (0.50) (9.00) 304.8 12.7 254 12.7 104.6 124 34.8 69.9 12.7 279.4 (12.00) (0.50) (10.00) (0.50) (4.12) (4.88) (1.37) (2.75) (0.50) (11.00) 1.016 0.508 0.254 0.508 0.254 1.016 0.508 1.016 0.508 0.254 (0.04) (0.02) (0.01) (0.02) (0.01) (0.04) (0.02) (0.04) (0.02) (0.01) T 2.00 (0.079) 2.00 (0.079) 2.00 (0.079) 3.00 (0.116) 3.00 (0.118) N/A Material List ITEM # PART NAME QTY MATERIAL 1 CHASSIS 1 ALUMINUM SHEET 2 COVER 1 ALUMINUM SHEET 3 LABEL 1 PAPER 4 LABEL 1 PAPER FILE NAME: CAD1:MSWORD:PA211242.DOC SCALE: NONE REV: D DATE:06/26/06 TITLE: OVS-U (UNIVERSAL OUTPUT) SERIES 43352 BUSINESS PARK DRIVE y TEMECULA y CA y 92590 TEL: (951) 699-1270 y FAX: 9516769482 DOCUMENT NUMBER: P-A2-11242 SH 6 OF 7 FILE NAME: CAD1:MSWORD:PA211242.DOC SCALE: NONE REV: D DATE:06/26/06 SH 7 OF 7 TITLE: OVS-U (UNIVERSAL OUTPUT) SERIES SPECIFICATION 43352 BUSINESS PARK DRIVE y TEMECULA y CA y 92590 TEL: (951) 699-1270 y FAX: 9516769482 DOCUMENT NUMBER: P-A2-11242